Abstract:
PURPOSE:To evaluate the diagnostic performance of gray-scale ultrasonography (US) and elastography in differentiating benign and malignant thyroid nodules. MATERIALS AND METHODS:This was an institutional review board-approved retrospective study with waiver of informed consent. A total of 703 solid thyroid nodules in 676 patients (mean age, 49.7 years; range, 18-79 years) were included; there were 556 women (mean age, 49.5 years; range, 20-74 years) and 120 men (mean age, 50.7 years; range, 18-79 years). Nodules with marked hypoechogenicity, poorly defined margins, microcalcifications, and a taller-than-wide shape were classified as suspicious at grayscale US. Findings at elastography were classified according to the Rago criteria and the Asteria criteria. The diagnostic performances of gray-scale US and elastography were compared. For comparison between the diagnostic performances of gray-scale US and the combination of gray-scale US and elastography, three sets of criteria were assigned: criteria set 1, nodules with any suspicious grayscale US feature were assessed as suspicious; criteria set 2, Rago criteria were added as suspicious features to criteria set 1; and criteria set 3, Asteria criteria were added as suspicious features to criteria set 1. The diagnostic performances of gray-scale US, elastography with Rago criteria, and elastography with Asteria criteria, and odds ratios (ORs) with 95% confidence intervals for predicting thyroid malignancy were compared using generalized estimating equation analysis. RESULTS:Of 703 nodules, 217 were malignant and 486 were benign. Sensitivity, negative predictive value (NPV), and OR of gray-scale US for the 703 nodules were 91.7%, 94.7%, and 22.1, respectively, and these values were higher than the 15.7% and 65.4% sensitivity, 71.7% and 79.1% NPV, and 3.7 and 2.6 ORs found for elastography with Rago and Asteria criteria, respectively. Specificity, positive predictive value, and accuracy for criteria set 1 were significantly higher than those for criteria sets 2 and 3 for most of the nodule subgroups that were considered. CONCLUSION:Elastography alone, as well as the combination of elastography and gray-scale US, showed inferior performance in the differentiation of malignant and benign thyroid nodules compared with gray-scale US features; elastography was not a useful tool in recommending fine-needle aspiration biopsy.
journal_name
Radiologyjournal_title
Radiologyauthors
Moon HJ,Sung JM,Kim EK,Yoon JH,Youk JH,Kwak JYdoi
10.1148/radiol.11110839subject
Has Abstractpub_date
2012-03-01 00:00:00pages
1002-13issue
3eissn
0033-8419issn
1527-1315pii
262/3/1002journal_volume
262pub_type
杂志文章相关文献
RADIOLOGY文献大全abstract::Pleural disease is an unusual manifestation of childhood leukemia. Three cases are presented which illustrate a definite association between leukemia and pleural thickening. In two patients, there was bilateral diffuse pleural thickening and, in the other, there were unilateral pleural-based masses. Pleural disease ma...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.138.2.6935700
更新日期:1981-02-01 00:00:00
abstract::Digital subtraction angiography (DSA) was used to study the cardiovascular system in more than 400 patients and was specifically compared with conventional angiography of the aorta and renal arteries in 30 patients. For the renal arteries, the overall accuracy of DSA was 71% (50/70). Excluding 11 cases of inadequate v...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.139.2.7012920
更新日期:1981-05-01 00:00:00
abstract::Several examples of a peculiar deforming process about the ankle joint resulting in a tibiotalar deformity are reported. When found in black patients, further examination for sickle cell disease should be done. No previous mention of this deformity in connection with sickle cell anemia has been found. ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/117.3.551
更新日期:1975-12-01 00:00:00
abstract:PURPOSE:To determine whether the carpal lunotriquetral ligament (LTL) can be consistently seen and to establish the normal range of LTL appearances at magnetic resonance (MR) imaging as a basis for comparison with LTL tears. MATERIALS AND METHODS:MR imaging was used to identify and characterize the LTL in 75 wrists wi...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.191.1.8134570
更新日期:1994-04-01 00:00:00
abstract::Purpose To compare the diagnostic performance of minimally invasive autopsy with that of conventional autopsy. Materials and Methods For this prospective, single-center, cross-sectional study in an academic hospital, 295 of 2197 adult cadavers (mean age: 65 years [range, 18-99 years]; age range of male cadavers: 18-99...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2018180924
更新日期:2018-12-01 00:00:00
abstract::High fecal impaction resulted in complete bowel obstruction in 2 children following renal transplantation and in one adult on chemotherapy and narcotics. The usual methods of relief failed, and water-soluble contrast enemas with a high osmolality were employed. Fluoroscopic control assured placement of the enema fluid...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/115.1.9
更新日期:1975-04-01 00:00:00
abstract:PURPOSE:To evaluate the potential use of technetium 99m (99mTc) (V) dimercaptosuccinic acid (DMSA) scintigraphy in the detection and localization of intestinal inflammation. MATERIALS AND METHODS:In a prospective study, 62 patients who were suspected of having intestinal inflammation and 30 control subjects were enrol...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.220.2.r01au30381
更新日期:2001-08-01 00:00:00
abstract:PURPOSE:To evaluate independent double reading in mammography screening and, specifically, the effect on breast cancer detection. MATERIALS AND METHODS:Mammographic studies of 11,343 women, aged 41-75 years, who participated in a population-based screening program were independently screened by two experienced radiolo...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.191.1.8134580
更新日期:1994-04-01 00:00:00
abstract:PURPOSE:To evaluate the feasibility of positron emission tomography (PET) with 2-[fluorine-18]-fluoro-2-deoxy-D-glucose (FDG) in patients with germ cell tumor (GCT) to monitor treatment and differentiate residual masses after chemotherapy. MATERIALS AND METHODS:Twenty-six FDG PET studies were performed in 21 patients ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.211.1.r99ap16249
更新日期:1999-04-01 00:00:00
abstract::Renal failure induced by intravenous iodinated contrast media is a frequent medical problem. While such cases are generally reported first by the clinician, the phenomenon can be seen even earlier by the radiologist. An abnormally persistent nephrogram is a sign of abnormal clearance, which in turn should alert the ph...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/131.2.553
更新日期:1979-05-01 00:00:00
abstract::Sixteen patients with biliary atresia and 11 patients with neonatal hepatitis were studied preoperatively with either Tc-99m-diethyl-IDA or TC-99m-diisopropyl-IDA. Two parameters were evaluated: hepatocyte clearance and time to appearance of radioactivity in the intestine. Two observers, using a visual grading system ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.146.2.6681570
更新日期:1983-02-01 00:00:00
abstract::Severe peripheral vasoconstriction of the legs due to hypersensitivity to small doses of ergotamine tartrate developed in a patient with migraine headaches. The vasospasm was successfully treated with continuous intra-arterial and intravenous infusion of sodium nitroprusside. The contribution of angiography in the dia...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/124.1.73
更新日期:1977-07-01 00:00:00
abstract::Treatment of complex intracranial aneurysms by means of interventional neurovascular techniques is now being performed with a newly developed silicone detachable-microballoon device. The balloon is composed of unique silicone elastomers that are extremely soft and malleable. It therefore conforms to the blood vessel l...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.174.3.2305050
更新日期:1990-03-01 00:00:00
abstract::Significant structural and mechanical differences exist between the titanium and stainless steel versions of the Greenfield filter (GF). The titanium GF has a longer leg length (49 mm vs 43 mm), a greater span (38.5 mm vs 28.0 mm), and a larger hook angle (41 degrees vs 23.5 degrees). In vitro tests demonstrated appro...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.173.3.2813790
更新日期:1989-12-01 00:00:00
abstract::Gadolinium chelates, intended as intravenous contrast media for magnetic resonance imaging, have been regarded as nonnephrotoxic and recommended to replace iodinated contrast media in patients with azotemia who are undergoing digital subtraction angiography (DSA). High intraarterial doses (up to 220 mmol of gadodiamid...
journal_title:Radiology
pub_type: 杂志文章,评审
doi:10.1148/radiol.2232010221
更新日期:2002-05-01 00:00:00
abstract::Self-expanding metallic stents of a modified Gianturco design were used to treat benign strictures of the biliary tree in 17 patients. Thirteen patients had undergone several unsuccessful surgical repairs, and four had not undergone surgery because of their clinical status. All patients had already undergone multiple ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.175.3.2343110
更新日期:1990-06-01 00:00:00
abstract::Pulmonary arteriography is an invasive but relatively safe diagnostic procedure. It is generally believed that the presence of pulmonary hypertension is one risk factor that increases the likelihood of a major complication. To assess the magnitude of risk, the reports on 1,434 patients who underwent pulmonary arteriog...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.162.1.3786760
更新日期:1987-01-01 00:00:00
abstract::Clinical, angiographic, scintigraphic and pathologic observations in myocardial contusion were correlated. Radionuclide imaging of the injured heart with 99mTc-Sn-polyphosphate provides an accurate diagnosis in acute, even mild, myocardial contusion. The study can be carried out without danger to the critically ill pa...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/116.3.679
更新日期:1975-09-01 00:00:00
abstract:PURPOSE:To retrospectively evaluate whether magnetic resonance (MR) imaging findings can be used to differentiate necrotizing infectious fasciitis (NIF) from nonnecrotizing infectious fasciitis (non-NIF). MATERIALS AND METHODS:Institutional review board approval was obtained, but patient consent was not required for t...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.11101164
更新日期:2011-06-01 00:00:00
abstract::Involvement of the terminal ileum in cases of cecal carcinoma usually results from direct extension through the cecal wall and ileocecal valve. Extensive lymphatic metastasis from cecal carcinoma can result in deranged lymphatic flow and apparently cause metastatic involvement of the ileum and its mesentery in the abs...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.135.1.7360980
更新日期:1980-04-01 00:00:00
abstract::Although intravascular foreign bodies are routinely removed with percutaneous extraction, surgical retrieval is performed of most nonvascular foreign bodies. The authors describe six cases in which percutaneous extraction was performed for removal of nonvascular foreign bodies. These foreign bodies included an intraab...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.187.3.8497610
更新日期:1993-06-01 00:00:00
abstract::Management of advanced or recurrent primary tracheal neoplasms has been restricted to palliative external beam irradiation. A patient with recurrent adenoid cystic carcinoma of the trachea was recently treated again by combined external irradiation and endotracheal brachytherapy with iridium 192 sources; the results w...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/128.1.209
更新日期:1978-07-01 00:00:00
abstract:PURPOSE:To optimize detection and diagnosis of breast lesions with contrast-enhanced magnetic resonance (MR) imaging. MATERIALS AND METHODS:A three-dimensional fast low-angle shot pulse sequence was used for a group comparison consisting of 76 high-dose (0.16 mmol gadopentetate dimeglumine per kilogram of body weight)...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.191.3.8184040
更新日期:1994-06-01 00:00:00
abstract:PURPOSE:To investigate the implications of mistaking the medial surface of the cerebral hemisphere for the medial wall of the lateral ventricle at antenatal ultrasonography (US) and to identify US clues that might help avoid this interpretive error. MATERIALS AND METHODS:In 50 second- and third-trimester fetuses, a di...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.205.3.9393540
更新日期:1997-12-01 00:00:00
abstract:PURPOSE:To determine factors associated with research productivity among all university radiology departments in the United States. MATERIALS AND METHODS:As an observational study, this was exempt from institutional review board approval. All 47,299 radiology articles from 1996 through 2003 that were indexed in the Na...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2373041508
更新日期:2005-12-01 00:00:00
abstract:PURPOSE:To assess the usefulness of intraarterial computed tomographic (CT) angiography in conjunction with digital subtraction angiography (DSA) by using a combined CT and angiographic unit in the preoperative evaluation of intracranial aneurysms. MATERIALS AND METHODS:Prospectively, 22 patients with or without subar...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.220.2.r01au20499
更新日期:2001-08-01 00:00:00
abstract::The authors retrospectively evaluated 12 patients with congenital (neonatal) neuroblastoma to assess the utility of newer imaging modalities. Findings at prenatal ultrasound (US), performed in four patients, were nonspecific (hydramnios and hydrops fetalis) in two and consistent with a suprarenal mass (one solid, one ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.175.2.2183280
更新日期:1990-05-01 00:00:00
abstract:PURPOSE:To present our experience with helical computed tomographic (CT) arteriography as the initial diagnostic examination in patients suspected to have focal arterial injuries of the proximal extremities. MATERIALS AND METHODS:During 19 months, 142 arterial segments in the proximal portions of the extremities of 13...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.218.1.r01ja13188
更新日期:2001-01-01 00:00:00
abstract:PURPOSE:To assess the frequency of splenic vein thrombosis (SVT) after splenectomy and its consequences on patient treatment. MATERIALS AND METHODS:A group of 183 consecutive patients who underwent splenectomy were evaluated. Of these patients, 119 underwent postoperative ultrasound (US) or computed tomography. RESUL...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.190.1.8259430
更新日期:1994-01-01 00:00:00
abstract::Percutaneous transhepatic removal of common bile duct stones was performed 54 times in 50 patients with a success rate of 93%. In all patients, a modified Dormia basket was inserted through a percutaneous transhepatic catheter, and the stones or fragments were advanced into the duodenum. All patients had contraindicat...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.170.3.2916070
更新日期:1989-03-01 00:00:00