Abstract:
:A new percutaneous inferior venacaval filter was used in 15 patients. The filter is constructed of stainless steel wires formed into a helical basket and anchoring legs. It can be inserted through a 10F catheter in an antegrade or retrograde fashion and can also be retrieved percutaneously. In a follow-up period of up to 13 months, the filter was well tolerated. One patient died of recurrent embolism despite filter protection. Local thrombogenicity was noted in 2 patients, but no other side effects were observed. Short-term heparinization following filter insertion is advisable. Heparin coating of the filter is under evaluation.
journal_name
Cardiovasc Intervent Radioljournal_title
Cardiovascular and interventional radiologyauthors
Günther RW,Schild H,Hollman JP,Vorwerk Ddoi
10.1007/BF02577978subject
Has Abstractpub_date
1987-01-01 00:00:00pages
104-8issue
2eissn
0174-1551issn
1432-086Xjournal_volume
10pub_type
杂志文章abstract:PURPOSE:To present a series of cases of non-cirrhotic patients with symptomatic massive portal thrombosis treated by percutaneous techniques. All patients underwent a TIPS procedure in order to maintain the patency of the portal vein by facilitating the outflow. METHODS:A total of six patients were treated for thrombo...
journal_title:Cardiovascular and interventional radiology
pub_type: 杂志文章
doi:10.1007/s00270-004-0241-z
更新日期:2004-09-01 00:00:00
abstract::Phantom limb pain is a frequent consequence of the amputation; currently available treatments are far from satisfactory. The present report describes a case in which transcatheter arterial microembolization had a remarkable curative effect on phantom limb pain persisting for 17 years. The patient began feeling phantom...
journal_title:Cardiovascular and interventional radiology
pub_type: 杂志文章
doi:10.1007/s00270-018-2109-7
更新日期:2019-03-01 00:00:00
abstract:PURPOSE:The hepatic vein access during transjugular intrahepatic portosystemic shunt (TIPS) can be challenging in liver transplant recipient patients, especially when piggyback anastomosis was performed. We described a modified technique and reviewed the clinical outcomes of TIPS in transplanted patients. MATERIALS AN...
journal_title:Cardiovascular and interventional radiology
pub_type: 杂志文章
doi:10.1007/s00270-018-1886-3
更新日期:2018-05-01 00:00:00
abstract::The current study retrospectively evaluated whether endovascular revascularization of chronically thrombosed and long-discarded vascular access sites for hemodialysis was feasible. Technical and clinical success rates, postintervention primary and secondary patency rates, and complications were reported. During a 1-ye...
journal_title:Cardiovascular and interventional radiology
pub_type: 杂志文章
doi:10.1007/s00270-010-9926-7
更新日期:2011-04-01 00:00:00
abstract::In a radiologic search for embolized leaflets of Edwards-Duromedics bileaflet valves in 2 patients, the embolized fragments were localized in the iliac vessels using computed tomography. Sonography was successful in one case and standard X-ray films of the abdomen were negative in both cases. In vitro investigations w...
journal_title:Cardiovascular and interventional radiology
pub_type: 杂志文章
doi:10.1007/BF02577118
更新日期:1989-01-01 00:00:00
abstract:PURPOSE:The aim of this study is to evaluate the feasibility of percutaneous lung tumor biopsy under cone beam-computed tomography (CBCT) with PET-CT imaging fusion. MATERIALS AND METHODS:Eleven patients (four women and seven men) underwent C-arm CBCT lung biopsy with PET-CT fusion imaging. A preprocedural PET-CT scan...
journal_title:Cardiovascular and interventional radiology
pub_type: 杂志文章
doi:10.1007/s00270-019-02270-1
更新日期:2019-11-01 00:00:00
abstract::Congenital anomalies of the inferior vena cava (IVC) are increasingly recognized with CT and venography techniques. Although many patients with IVC anomalies are asymptomatic, recent studies have suggested an association with venous thromboembolism. We report the case of a 62-year-old woman with extensive venous clot ...
journal_title:Cardiovascular and interventional radiology
pub_type: 杂志文章
doi:10.1007/s00270-013-0559-5
更新日期:2013-12-01 00:00:00
abstract::Renal arteriovenous fistula (AVF) is rare. Renal AVF complicated by aneurysm of the feeding artery presents a technical challenge for endovascular treatment. We report a case managed by covered stenting of the renal artery aneurysm, coil embolization of the fistula, and bare stenting of the aorta. ...
journal_title:Cardiovascular and interventional radiology
pub_type: 杂志文章
doi:10.1007/s00270-006-0184-7
更新日期:2008-03-01 00:00:00
abstract:OBJECTIVE:To evaluate the mid-term feasibility, efficacy, and durability of descending thoracic aortic aneurysm (DTAA) exclusion using the EndoFit device (LeMaitre Vascular). METHODS:Twenty-three (23) men (mean age 66 years) with a DTAA were admitted to our department for endovascular repair (21 were ASA III+ and 2 re...
journal_title:Cardiovascular and interventional radiology
pub_type: 杂志文章
doi:10.1007/s00270-006-0168-7
更新日期:2007-03-01 00:00:00
abstract:PURPOSE:To assess the efficacy and safety of a newly developed fully covered irradiation stent (FCIS) compared with a partially covered irradiation stent (PCIS) in patients with unresectable malignant dysphagia. MATERIALS AND METHODS:Data of 195 patients [158 (81.0%) males, median age of 75 years (range 49-89 years)] ...
journal_title:Cardiovascular and interventional radiology
pub_type: 杂志文章
doi:10.1007/s00270-019-02252-3
更新日期:2019-08-01 00:00:00
abstract:BACKGROUND:Most epidermal growth factor receptor (EGFR)-mutant non-small cell lung cancer (NSCLC) patients treated with tyrosine kinase inhibitors (TKIs) experience oligoprogressive disease. Local ablation for isolated resistant sites continued with the original EGFR-TKI showed good efficacy in these patients. We condu...
journal_title:Cardiovascular and interventional radiology
pub_type: 杂志文章,多中心研究
doi:10.1007/s00270-018-02153-x
更新日期:2019-05-01 00:00:00
abstract:PURPOSE:To evaluate the technical feasibility and clinical efficacy of placement of a newly designed Y-shaped branched covered stent for palliative treatment of malignant hilar biliary obstruction. METHODS:From June 2011 to September 2014, 34 consecutive patients with malignant hilar biliary obstruction underwent perc...
journal_title:Cardiovascular and interventional radiology
pub_type: 杂志文章
doi:10.1007/s00270-015-1205-1
更新日期:2016-04-01 00:00:00
abstract::An unusual case of unintentional release of an embolization coil into the proximal internal carotid artery is reported. The coil migrated and lodged distally in the petrous portion of the internal carotid artery during initial removal attempts using a regular nitinol loop snare. The coil was retrieved with the Amplatz...
journal_title:Cardiovascular and interventional radiology
pub_type: 杂志文章
doi:10.1007/BF00239425
更新日期:1995-07-01 00:00:00
abstract::We implanted stents in three patients who had traumatic abdominal aortic dissections, complicated by right limb ischemia in one case. The circulating false channel extended to the left iliac artery in one case and to both iliac arteries in the last case. Diagnosis and radiological follow-up included ultrasound, comput...
journal_title:Cardiovascular and interventional radiology
pub_type: 杂志文章
doi:10.1007/s002709900197
更新日期:1997-11-01 00:00:00
abstract::We report about a patient presenting with back pain 4 months after an uneventful endovascular implantation of an aortic stent graft. Computed tomography scan revealed a migration of the stent with consecutive endoleakage, kink formation, and movement of the stent toward the spine, which caused destruction of the aorti...
journal_title:Cardiovascular and interventional radiology
pub_type: 杂志文章
doi:10.1007/s00270-013-0695-y
更新日期:2013-12-01 00:00:00
abstract::We report an avulsion of a transplant upper pole renal artery following apparently successful percutaneous transluminal angioplasty (PTA) of a stenosis involving main, upper, and lower pole renal arteries. We believe that the use of a high pressure balloon was the causative factor. If the branches at the bifurcation c...
journal_title:Cardiovascular and interventional radiology
pub_type: 杂志文章
doi:10.1007/BF02577068
更新日期:1988-04-01 00:00:00
abstract:PURPOSE:This study was designed to evaluate the accuracy and safety of electromagnetic needle tracking for sonographically guided percutaneous liver biopsies. METHODS:We performed 23 consecutive ultrasound-guided liver biopsies for liver nodules with an electromagnetic tracking of the needle. A sensor placed at the ti...
journal_title:Cardiovascular and interventional radiology
pub_type: 杂志文章
doi:10.1007/s00270-011-0278-8
更新日期:2012-08-01 00:00:00
abstract::A method is described for protecting a nonstenotic anomalous artery to the left-lower pole of a horseshoe kidney that originated from a stenotic left common iliac artery. Using a triple catheter technique, injury to this anomalous renal artery was prevented while using "kissing balloons" to dilate bilateral proximal c...
journal_title:Cardiovascular and interventional radiology
pub_type: 杂志文章
doi:10.1007/BF02575433
更新日期:1989-11-01 00:00:00
abstract:INTRODUCTION:The drop-off risk for patients awaiting liver transplantation for hepatocellular carcinoma (HCC) is 22%. Transplant liver availability is expected to worsen, resulting in longer waiting times and increased drop-off rates. Our aim was to determine whether chemoembolization can decrease this risk. PATIENTS ...
journal_title:Cardiovascular and interventional radiology
pub_type: 杂志文章
doi:10.1007/s00270-010-0077-7
更新日期:2011-12-01 00:00:00
abstract::A 66-year-old man presented with bilateral subclavian steal syndrome (SSS) due to proximal subclavian artery occlusions. He was treated by percutaneous transluminal balloon angioplasty (PTA) and stent implantation in the left subclavian artery and by PTA alone in the right subclavian artery. We could demonstrate that ...
journal_title:Cardiovascular and interventional radiology
pub_type: 杂志文章
doi:10.1007/BF00203952
更新日期:1994-11-01 00:00:00
abstract:OBJECTIVE:For evaluation of primary aldosteronism, international guidelines recommend a 4-6 week withdrawal of spironolactone, eplerenone, and amiloride prior to adrenal vein sampling (AVS). It is not always feasible to withdraw these drugs in patients with severe hypertension and hypokalemia. We present our experience...
journal_title:Cardiovascular and interventional radiology
pub_type: 杂志文章
doi:10.1007/s00270-017-1637-x
更新日期:2017-09-01 00:00:00
abstract::A technique is described that allowed percutaneous retrieval of an endoscopically placed, obstructed biliary stent using loop snare capture of an angled hydrophilic wire which was wrapped around the stent initially. ...
journal_title:Cardiovascular and interventional radiology
pub_type: 杂志文章
doi:10.1007/BF02577656
更新日期:1996-07-01 00:00:00
abstract::Nanotechnology can be defined as the design, creation, and manipulation of structures on the nanometer scale. This two-part review is intended to acquaint the interventionalist with the field of nanotechnology, and provide an overview of potential applications, while highlighting advances relevant to interventional ra...
journal_title:Cardiovascular and interventional radiology
pub_type: 杂志文章,评审
doi:10.1007/s00270-010-9967-y
更新日期:2011-08-01 00:00:00
abstract::The purpose of this study was to evaluate the fibroid morphology in a cohort of women achieving pregnancy following treatment with uterine artery embolization (UAE) for symptomatic uterine fibroids. A retrospective review of magnetic resonance imaging (MRI) of the uterus was performed to assess pre-embolization fibroi...
journal_title:Cardiovascular and interventional radiology
pub_type: 杂志文章
doi:10.1007/s00270-007-9118-2
更新日期:2007-09-01 00:00:00
abstract::Substantial improvements have been made in the systemic treatment of colorectal cancer over the last two decades. Median overall survival (OS) of patients with metastatic colorectal cancer (mCRC) has been constantly increased and the most recent first-line studies exceeded the 30-month median overall survival. The sta...
journal_title:Cardiovascular and interventional radiology
pub_type: 杂志文章,评审
doi:10.1007/s00270-019-02278-7
更新日期:2019-09-01 00:00:00
abstract:PURPOSE:To prospectively analyze the effectiveness of computed tomography-guided percutaneous lumbar sympathectomy (CTLS) in patients with peripheral arterial occlusive disease in relation to angiographic findings and vascular risk factors. METHODS:Eighty-three patients were treated by CTLS. After clinical evaluation ...
journal_title:Cardiovascular and interventional radiology
pub_type: 临床试验,杂志文章
doi:10.1007/s002709900268
更新日期:1998-07-01 00:00:00
abstract:PURPOSE:Comparison of the biocompatibility of self-expanding polyethylene terephthalate (PET) stents with self-expanding metallic stents (Wallstents). METHODS:Diameter- and length-matched PET stents and Wallstents were symmetrically implanted in the paired iliac arteries of 13 crossbred domestic swine. Stent deploymen...
journal_title:Cardiovascular and interventional radiology
pub_type: 杂志文章
doi:10.1007/BF02577615
更新日期:1996-05-01 00:00:00
abstract:BACKGROUND AND AIMS:Until now, no study has focused exclusively on low-flow retrobulbar intraconal venous malformations (RIVMs) which may require treatment due to cosmetic defect, pain, and visual dysfunction. The treatment for RIVMs which surround the optic nerve remains challenging. This case series aimed to evaluate...
journal_title:Cardiovascular and interventional radiology
pub_type: 杂志文章
doi:10.1007/s00270-017-1822-y
更新日期:2018-03-01 00:00:00
abstract:PURPOSE:To compare pulse-spray to continuous-infusion thrombolysis with high-dose urokinase in thrombosed dialysis access grafts. METHODS:A prospective randomized controlled trial was performed. From August 1992 to September 1993, 30 thrombosed polytetrafluoroethylene (PTFE) grafts in 24 patients were included, 15 gra...
journal_title:Cardiovascular and interventional radiology
pub_type: 临床试验,杂志文章,随机对照试验
doi:10.1007/s002709900229
更新日期:1998-03-01 00:00:00
abstract::A three-dimensional model was constructed from helical CT images for abdominal aortic aneurysm (AAA) and thoracic aortic aneurysm (TAA). A stent-graft was designed and positioned endoluminally on the computer. One hundred and nine stent-grafts for 101 patients were designed by this method and deployed well in all pati...
journal_title:Cardiovascular and interventional radiology
pub_type: 杂志文章
doi:10.1007/s00270-001-0383-8
更新日期:2001-07-01 00:00:00