First clinical results with a new caval filter.

Abstract:

:A new percutaneous inferior venacaval filter was used in 15 patients. The filter is constructed of stainless steel wires formed into a helical basket and anchoring legs. It can be inserted through a 10F catheter in an antegrade or retrograde fashion and can also be retrieved percutaneously. In a follow-up period of up to 13 months, the filter was well tolerated. One patient died of recurrent embolism despite filter protection. Local thrombogenicity was noted in 2 patients, but no other side effects were observed. Short-term heparinization following filter insertion is advisable. Heparin coating of the filter is under evaluation.

authors

Günther RW,Schild H,Hollman JP,Vorwerk D

doi

10.1007/BF02577978

subject

Has Abstract

pub_date

1987-01-01 00:00:00

pages

104-8

issue

2

eissn

0174-1551

issn

1432-086X

journal_volume

10

pub_type

杂志文章
  • Transjugular intrahepatic portosystemic shunt (TIPS) in the treatment of venous symptomatic chronic portal thrombosis in non-cirrhotic patients.

    abstract:PURPOSE:To present a series of cases of non-cirrhotic patients with symptomatic massive portal thrombosis treated by percutaneous techniques. All patients underwent a TIPS procedure in order to maintain the patency of the portal vein by facilitating the outflow. METHODS:A total of six patients were treated for thrombo...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-004-0241-z

    authors: Bilbao JI,Elorz M,Vivas I,Martínez-Cuesta A,Bastarrika G,Benito A

    更新日期:2004-09-01 00:00:00

  • Effect of Transcatheter Arterial Microembolization on Phantom Limb Pain Persisting for 17 Years.

    abstract::Phantom limb pain is a frequent consequence of the amputation; currently available treatments are far from satisfactory. The present report describes a case in which transcatheter arterial microembolization had a remarkable curative effect on phantom limb pain persisting for 17 years. The patient began feeling phantom...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-018-2109-7

    authors: Shibuya M,Yamamoto M,Okuno Y

    更新日期:2019-03-01 00:00:00

  • Challenging TIPS in Liver Transplant Recipients: The Pull-Through Technique to Address Piggyback Anastomosis.

    abstract:PURPOSE:The hepatic vein access during transjugular intrahepatic portosystemic shunt (TIPS) can be challenging in liver transplant recipient patients, especially when piggyback anastomosis was performed. We described a modified technique and reviewed the clinical outcomes of TIPS in transplanted patients. MATERIALS AN...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-018-1886-3

    authors: Schembri V,Cassinotto C,Panaro F,Delicque J,Pierredon MA,Piron L,Herrero A,Escal L,Ursic-Bedoya J,Guiu B

    更新日期:2018-05-01 00:00:00

  • Endovascular revascularization of chronically thrombosed arteriovenous fistulas and grafts for hemodialysis: a retrospective study in 15 patients with 18 access sites.

    abstract::The current study retrospectively evaluated whether endovascular revascularization of chronically thrombosed and long-discarded vascular access sites for hemodialysis was feasible. Technical and clinical success rates, postintervention primary and secondary patency rates, and complications were reported. During a 1-ye...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-010-9926-7

    authors: Weng MJ,Chen MC,Chi WC,Liu YC,Liang HL,Pan HB

    更新日期:2011-04-01 00:00:00

  • Radiologic search for embolized leaflets of prosthetic heart valves: a report of two cases.

    abstract::In a radiologic search for embolized leaflets of Edwards-Duromedics bileaflet valves in 2 patients, the embolized fragments were localized in the iliac vessels using computed tomography. Sonography was successful in one case and standard X-ray films of the abdomen were negative in both cases. In vitro investigations w...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/BF02577118

    authors: Schurawitzki H,Hajek PC,Kramer J,Grabenwöger F,Klepetko W,Moritz A

    更新日期:1989-01-01 00:00:00

  • Percutaneous Lung Tumor Biopsy Under CBCT Guidance with PET-CT Fusion Imaging: Preliminary Experience.

    abstract:PURPOSE:The aim of this study is to evaluate the feasibility of percutaneous lung tumor biopsy under cone beam-computed tomography (CBCT) with PET-CT imaging fusion. MATERIALS AND METHODS:Eleven patients (four women and seven men) underwent C-arm CBCT lung biopsy with PET-CT fusion imaging. A preprocedural PET-CT scan...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-019-02270-1

    authors: Floridi C,Carnevale A,Fumarola EM,Schampaert S,Fontana F,De Palma D,Del Sole A,Giganti M,Carrafiello G

    更新日期:2019-11-01 00:00:00

  • Use of a Trellis device for endovascular treatment of venous thrombosis involving a duplicated inferior vena cava.

    abstract::Congenital anomalies of the inferior vena cava (IVC) are increasingly recognized with CT and venography techniques. Although many patients with IVC anomalies are asymptomatic, recent studies have suggested an association with venous thromboembolism. We report the case of a 62-year-old woman with extensive venous clot ...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-013-0559-5

    authors: Saettele MR,Morelli JN,Chesis P,Wible BC

    更新日期:2013-12-01 00:00:00

  • Transcatheter embolization of a renal arteriovenous fistula complicated by an aneurysm of the feeding renal artery.

    abstract::Renal arteriovenous fistula (AVF) is rare. Renal AVF complicated by aneurysm of the feeding artery presents a technical challenge for endovascular treatment. We report a case managed by covered stenting of the renal artery aneurysm, coil embolization of the fistula, and bare stenting of the aorta. ...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-006-0184-7

    authors: Kensella D,Kakani N,Pocock R,Thompson J,Cowan A,Watkinson A

    更新日期:2008-03-01 00:00:00

  • Endovascular treatment of descending thoracic aortic aneurysms with the EndoFit stent-graft.

    abstract:OBJECTIVE:To evaluate the mid-term feasibility, efficacy, and durability of descending thoracic aortic aneurysm (DTAA) exclusion using the EndoFit device (LeMaitre Vascular). METHODS:Twenty-three (23) men (mean age 66 years) with a DTAA were admitted to our department for endovascular repair (21 were ASA III+ and 2 re...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-006-0168-7

    authors: Saratzis N,Saratzis A,Melas N,Ginis G,Lioupis A,Lykopoulos D,Lazaridis J,Kiskinis D

    更新日期:2007-03-01 00:00:00

  • A New Fully Covered Irradiation Stent Versus a Partially Covered Irradiation Stent for Unresectable Malignant Dysphagia: A Single-Center Experience.

    abstract:PURPOSE:To assess the efficacy and safety of a newly developed fully covered irradiation stent (FCIS) compared with a partially covered irradiation stent (PCIS) in patients with unresectable malignant dysphagia. MATERIALS AND METHODS:Data of 195 patients [158 (81.0%) males, median age of 75 years (range 49-89 years)] ...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-019-02252-3

    authors: Wang C,Lu J,Wang Y,Zhu GY,Chen L,Li JC,Li TK,Chen L,Guo JH

    更新日期:2019-08-01 00:00:00

  • Local Thermal Ablation with Continuous EGFR Tyrosine Kinase Inhibitors for EGFR-Mutant Non-small Cell Lung Cancers that Developed Extra-Central Nervous System (CNS) Oligoprogressive Disease.

    abstract:BACKGROUND:Most epidermal growth factor receptor (EGFR)-mutant non-small cell lung cancer (NSCLC) patients treated with tyrosine kinase inhibitors (TKIs) experience oligoprogressive disease. Local ablation for isolated resistant sites continued with the original EGFR-TKI showed good efficacy in these patients. We condu...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章,多中心研究

    doi:10.1007/s00270-018-02153-x

    authors: Ni Y,Liu B,Ye X,Fan W,Bi J,Yang X,Huang G,Li W,Wang J,Han X,Wei Z,Meng M

    更新日期:2019-05-01 00:00:00

  • Malignant Hilar Biliary Obstruction: Treatment by Means of Placement of a Newly Designed Y-Shaped Branched Covered Stent.

    abstract:PURPOSE:To evaluate the technical feasibility and clinical efficacy of placement of a newly designed Y-shaped branched covered stent for palliative treatment of malignant hilar biliary obstruction. METHODS:From June 2011 to September 2014, 34 consecutive patients with malignant hilar biliary obstruction underwent perc...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-015-1205-1

    authors: Yun JH,Jung GS,Park JG,Kang BC,Shin DH,Yun BC,Lee SU

    更新日期:2016-04-01 00:00:00

  • Retrieval of an embolization coil from the internal carotid artery using the Amplatz microsnare retrieval system.

    abstract::An unusual case of unintentional release of an embolization coil into the proximal internal carotid artery is reported. The coil migrated and lodged distally in the petrous portion of the internal carotid artery during initial removal attempts using a regular nitinol loop snare. The coil was retrieved with the Amplatz...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/BF00239425

    authors: Cekirge S,Saatci I,Firat MM,Balkanci F

    更新日期:1995-07-01 00:00:00

  • Dissection of the abdominal aorta in blunt trauma: management by percutaneous stent placement.

    abstract::We implanted stents in three patients who had traumatic abdominal aortic dissections, complicated by right limb ischemia in one case. The circulating false channel extended to the left iliac artery in one case and to both iliac arteries in the last case. Diagnosis and radiological follow-up included ultrasound, comput...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s002709900197

    authors: Vernhet H,Marty-Ané CH,Lesnik A,Chircop R,Serres-Cousiné O,Picard E,Mary H,Senac JP

    更新日期:1997-11-01 00:00:00

  • A migrated aortic stent graft causing erosive spondylopathy.

    abstract::We report about a patient presenting with back pain 4 months after an uneventful endovascular implantation of an aortic stent graft. Computed tomography scan revealed a migration of the stent with consecutive endoleakage, kink formation, and movement of the stent toward the spine, which caused destruction of the aorti...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-013-0695-y

    authors: Gestrich C,Probst C,Wilhelm K,Schiller W

    更新日期:2013-12-01 00:00:00

  • Unusual transplant renal angioplasty complication: case report.

    abstract::We report an avulsion of a transplant upper pole renal artery following apparently successful percutaneous transluminal angioplasty (PTA) of a stenosis involving main, upper, and lower pole renal arteries. We believe that the use of a high pressure balloon was the causative factor. If the branches at the bifurcation c...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/BF02577068

    authors: Weisman ID,Ney AL,Andrisevic JH,Stanchfield W Jr,Odland MD,Andersen RC

    更新日期:1988-04-01 00:00:00

  • Electromagnetic-tracked biopsy under ultrasound guidance: preliminary results.

    abstract:PURPOSE:This study was designed to evaluate the accuracy and safety of electromagnetic needle tracking for sonographically guided percutaneous liver biopsies. METHODS:We performed 23 consecutive ultrasound-guided liver biopsies for liver nodules with an electromagnetic tracking of the needle. A sensor placed at the ti...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-011-0278-8

    authors: Hakime A,Deschamps F,De Carvalho EG,Barah A,Auperin A,De Baere T

    更新日期:2012-08-01 00:00:00

  • Triple catheter aortoiliac angioplasty in a patient with a horseshoe kidney: technical note.

    abstract::A method is described for protecting a nonstenotic anomalous artery to the left-lower pole of a horseshoe kidney that originated from a stenotic left common iliac artery. Using a triple catheter technique, injury to this anomalous renal artery was prevented while using "kissing balloons" to dilate bilateral proximal c...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/BF02575433

    authors: Matsumoto AH,Baum PA,Barth KH,Teitelbaum GP

    更新日期:1989-11-01 00:00:00

  • Chemoembolization decreases drop-off risk of hepatocellular carcinoma patients on the liver transplant list.

    abstract:INTRODUCTION:The drop-off risk for patients awaiting liver transplantation for hepatocellular carcinoma (HCC) is 22%. Transplant liver availability is expected to worsen, resulting in longer waiting times and increased drop-off rates. Our aim was to determine whether chemoembolization can decrease this risk. PATIENTS ...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-010-0077-7

    authors: Frangakis C,Geschwind JF,Kim D,Chen Y,Koteish A,Hong K,Liapi E,Georgiades CS

    更新日期:2011-12-01 00:00:00

  • Bilateral subclavian steal syndrome: treatment with percutaneous transluminal angioplasty and stent placement.

    abstract::A 66-year-old man presented with bilateral subclavian steal syndrome (SSS) due to proximal subclavian artery occlusions. He was treated by percutaneous transluminal balloon angioplasty (PTA) and stent implantation in the left subclavian artery and by PTA alone in the right subclavian artery. We could demonstrate that ...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/BF00203952

    authors: Jaeger HJ,Mathias KD,Kempkes U

    更新日期:1994-11-01 00:00:00

  • Adrenal Vein Sampling for Primary Aldosteronism: A 2-Week Protocol for Withdrawal of Renin-Stimulating Antihypertensives.

    abstract:OBJECTIVE:For evaluation of primary aldosteronism, international guidelines recommend a 4-6 week withdrawal of spironolactone, eplerenone, and amiloride prior to adrenal vein sampling (AVS). It is not always feasible to withdraw these drugs in patients with severe hypertension and hypokalemia. We present our experience...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-017-1637-x

    authors: Ching KC,Cohen DL,Fraker DL,Trerotola SO

    更新日期:2017-09-01 00:00:00

  • In situ formation of a loop snare for retrieval of a foreign body without a free end.

    abstract::A technique is described that allowed percutaneous retrieval of an endoscopically placed, obstructed biliary stent using loop snare capture of an angled hydrophilic wire which was wrapped around the stent initially. ...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/BF02577656

    authors: Savader SJ,Brodkin J,Osterman FA Jr

    更新日期:1996-07-01 00:00:00

  • Nanotechnology and its relationship to interventional radiology. Part II: Drug Delivery, Thermotherapy, and Vascular Intervention.

    abstract::Nanotechnology can be defined as the design, creation, and manipulation of structures on the nanometer scale. This two-part review is intended to acquaint the interventionalist with the field of nanotechnology, and provide an overview of potential applications, while highlighting advances relevant to interventional ra...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00270-010-9967-y

    authors: Power S,Slattery MM,Lee MJ

    更新日期:2011-08-01 00:00:00

  • Magnetic resonance imaging (MRI) analysis of fibroid location in women achieving pregnancy after uterine artery embolization.

    abstract::The purpose of this study was to evaluate the fibroid morphology in a cohort of women achieving pregnancy following treatment with uterine artery embolization (UAE) for symptomatic uterine fibroids. A retrospective review of magnetic resonance imaging (MRI) of the uterus was performed to assess pre-embolization fibroi...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-007-9118-2

    authors: Walker WJ,Bratby MJ

    更新日期:2007-09-01 00:00:00

  • Chemotherapy, Still an Option in the Twenty-First Century in Metastatic Colorectal Cancer?

    abstract::Substantial improvements have been made in the systemic treatment of colorectal cancer over the last two decades. Median overall survival (OS) of patients with metastatic colorectal cancer (mCRC) has been constantly increased and the most recent first-line studies exceeded the 30-month median overall survival. The sta...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00270-019-02278-7

    authors: Eisterer W,Prager G

    更新日期:2019-09-01 00:00:00

  • CT-guided lumbar sympathectomy: results and analysis of factors influencing the outcome.

    abstract:PURPOSE:To prospectively analyze the effectiveness of computed tomography-guided percutaneous lumbar sympathectomy (CTLS) in patients with peripheral arterial occlusive disease in relation to angiographic findings and vascular risk factors. METHODS:Eighty-three patients were treated by CTLS. After clinical evaluation ...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 临床试验,杂志文章

    doi:10.1007/s002709900268

    authors: Heindel W,Ernst S,Manshausen G,Gawenda M,Siemens P,Krahe T,Walter M,Lackner K

    更新日期:1998-07-01 00:00:00

  • Comparison of self-expanding polyethylene terephthalate and metallic stents implanted in porcine iliac arteries.

    abstract:PURPOSE:Comparison of the biocompatibility of self-expanding polyethylene terephthalate (PET) stents with self-expanding metallic stents (Wallstents). METHODS:Diameter- and length-matched PET stents and Wallstents were symmetrically implanted in the paired iliac arteries of 13 crossbred domestic swine. Stent deploymen...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/BF02577615

    authors: Wilczek K,Scheerder ID,Wang K,Verbeken E,Piessens J

    更新日期:1996-05-01 00:00:00

  • CT-Guided Percutaneous Sclerotherapy for Low-Flow Retrobulbar Intraconal Venous Malformations.

    abstract:BACKGROUND AND AIMS:Until now, no study has focused exclusively on low-flow retrobulbar intraconal venous malformations (RIVMs) which may require treatment due to cosmetic defect, pain, and visual dysfunction. The treatment for RIVMs which surround the optic nerve remains challenging. This case series aimed to evaluate...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-017-1822-y

    authors: Yang B,Zhao J,Gao L,Li CL,Liu XR,Jiao H,Liao ZY,Yi C

    更新日期:2018-03-01 00:00:00

  • Dialysis access graft thrombolysis: randomized study of pulse-spray versus continuous urokinase infusion.

    abstract:PURPOSE:To compare pulse-spray to continuous-infusion thrombolysis with high-dose urokinase in thrombosed dialysis access grafts. METHODS:A prospective randomized controlled trial was performed. From August 1992 to September 1993, 30 thrombosed polytetrafluoroethylene (PTFE) grafts in 24 patients were included, 15 gra...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1007/s002709900229

    authors: Goodwin SC,Arora LC,Razavi MK,Sayre J,McNamara TO,Yoon C

    更新日期:1998-03-01 00:00:00

  • A system for computer-assisted design of stent-grafts for aortic aneurysms using 3-D morphological models.

    abstract::A three-dimensional model was constructed from helical CT images for abdominal aortic aneurysm (AAA) and thoracic aortic aneurysm (TAA). A stent-graft was designed and positioned endoluminally on the computer. One hundred and nine stent-grafts for 101 patients were designed by this method and deployed well in all pati...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-001-0383-8

    authors: Imai Y,Urayama S,Uyama C,Inoue K,Ueno K,Kuribayashi S,Takamiya M,Hamada S,Hirane Y

    更新日期:2001-07-01 00:00:00