Electromagnetic-tracked biopsy under ultrasound guidance: preliminary results.

Abstract:

PURPOSE:This study was designed to evaluate the accuracy and safety of electromagnetic needle tracking for sonographically guided percutaneous liver biopsies. METHODS:We performed 23 consecutive ultrasound-guided liver biopsies for liver nodules with an electromagnetic tracking of the needle. A sensor placed at the tip of a sterile stylet (18G) inserted in a coaxial guiding trocar (16G) used for biopsy was localized in real time relative to the ultrasound imaging plane, thanks to an electromagnetic transmitter and two sensors on the ultrasound probe. This allows for electronic display of the needle tip location and the future needle path overlaid on the real-time ultrasound image. Distance between needle tip position and its electronic display, number of needle punctures, number of needle pull backs for redirection, technical success (needle positioned in the target), diagnostic success (correct histopathology result), procedure time, and complication were evaluated according to lesion sizes, depth and location, operator experience, and "in-plane" or "out-of-plane" needle approach. RESULTS:Electronic display was always within 2 mm from the real position of the needle tip. The technical success rate was 100%. A single needle puncture without repuncture was used in all patients. Pull backs were necessary in six patients (26%) to obtain correct needle placement. The overall diagnostic success rate was 91%. The overall true-positive, true-negative, false-negative, and failure rates of the biopsy were 100% (19/19) 100% (2/2), 0% (0/23), and 9% (2/23). The median total procedure time from the skin puncture to the needle in the target was 30 sec (from 5-60 s). Lesion depth and localizations, operator experience, in-plane or out-of-plane approach did not affect significantly the technical, diagnostic success, or procedure time. Even when the tumor size decreased, the procedure time did not increase. CONCLUSIONS:Electromagnetic-tracked biopsy is accurate to determine needle tip position and allows fast and accurate needle placement in targeted liver nodules.

authors

Hakime A,Deschamps F,De Carvalho EG,Barah A,Auperin A,De Baere T

doi

10.1007/s00270-011-0278-8

subject

Has Abstract

pub_date

2012-08-01 00:00:00

pages

898-905

issue

4

eissn

0174-1551

issn

1432-086X

journal_volume

35

pub_type

杂志文章
  • Endovascular repair of ruptured abdominal aortic aneurysm: technical and team training in an immersive virtual reality environment.

    abstract:PURPOSE:This study evaluates a fully immersive simulated angiosuite for training and assessment of technical endovascular and human factor skills during a crisis scenario. MATERIALS AND METHODS:Virtual reality (VIST-C, Mentice) simulators were integrated into a simulated angiosuite (ORCAMP, Orzone). Teams, lead by exp...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-013-0765-1

    authors: Rudarakanchana N,Van Herzeele I,Bicknell CD,Riga CV,Rolls A,Cheshire NJ,Hamady MS

    更新日期:2014-08-01 00:00:00

  • Dialysis grafts arterial plug: retrieval using the tulip sheath device in vitro.

    abstract::The "arterial plug" is a resistant thrombus that frequently persists at the arterial anastomosis of clotted hemodialysis grafts following thrombolytic therapy. We studied the physical and morphological characteristics of the plug and determined the feasibility of transcatheter removal in vitro using the tulip compress...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s002709900126

    authors: Sharafuddin MJ,Titus JL,Gu X,Hunter DW,Amplatz K

    更新日期:1997-03-01 00:00:00

  • Complication rates and patency of radiologically guided mushroom gastrostomy, balloon gastrostomy, and gastrojejunostomy: a review of 250 procedures.

    abstract:PURPOSE:To compare complication rates and tube performance of percutaneous mushroom gastrostomy, balloon gastrostomy, and gastrojejunostomy. METHODS:Between September 9, 1999 and April 23, 2001, 203 patients underwent 250 radiologically guided percutaneous gastrostomy and gastrojejunostomy procedures. Follow-up was co...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-003-0108-8

    authors: Yip D,Vanasco M,Funaki B

    更新日期:2004-01-01 00:00:00

  • Endovascular Stroke Treatment: How Far Downstream Should We Go?

    abstract:BACKGROUND:Endovascular thrombectomy has become the de facto standard in the treatment of large vessel occlusion. Previously, a correlation between good outcome and the occlusion site, measured by the 'distance to thrombus' (DT)-as the distance from the carotid T to the beginning of the thrombus-after thrombolysis coul...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-017-1830-y

    authors: Friedrich B,Lobsien D,Wunderlich S,Maegerlein C,Pree D,Hoffmann KT,Zimmer C,Kaesmacher J

    更新日期:2018-01-01 00:00:00

  • Oscillating probe aspiration thrombectomy: comparative in vitro evaluation of two concepts.

    abstract::Aspiration thrombectomy supported by an oscillating metal probe within the catheter allows continuous aspiration of large thrombi without catheter obstruction. Thrombus aspiration assisted by an ultrasound-driven probe (frequency 26 kHz) and by an electric motor-driven probe (frequency 40 Hz) was compared in two diffe...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/BF02735577

    authors: Schmitz-Rode T,Günther RW

    更新日期:1992-05-01 00:00:00

  • Treatment of acute embolus of the superior mesenteric artery by topical infusion of streptokinase.

    abstract::Two patients with sudden onset of acute abdominal pain caused by embolic disease of the superior mesenteric artery (SMA) were evaluated angiographically. In one patient, the study was performed soon after the clinical onset of symptoms, and successful treatment with low-dose topical streptokinase infusion produced tot...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/BF02552688

    authors: Vujic I,Stanley J,Gobien RP

    更新日期:1984-01-01 00:00:00

  • A newly developed perfused umbrella electrode for radiofrequency ablation: an ex vivo evaluation study in bovine liver.

    abstract::The purpose of this study was to evaluate the effectiveness of a newly developed perfused monopolar radiofrequency (RF) probe with an umbrella-shaped array. A perfused umbrella-shaped monopolar RF probe based on a LeVeen electrode (Boston Scientific Corp., Natick, MA, USA) with a 3-cm array diameter was developed. Fiv...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-007-9125-3

    authors: Bruners P,Pfeffer J,Kazim RM,Günther RW,Schmitz-Rode T,Mahnken AH

    更新日期:2007-09-01 00:00:00

  • Stereotactic Radiofrequency Ablation for Metastatic Melanoma to the Liver.

    abstract:PURPOSE:To evaluate the outcome of patients with melanoma liver metastasis treated with stereotactic radiofrequency ablation (SRFA). MATERIAL AND METHOD:Following IRB approval, a retrospective evaluation of the treatment of 20 patients with 75 melanoma liver metastases was performed. RESULTS:A median number of 2 lesi...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-016-1336-z

    authors: Bale R,Schullian P,Schmuth M,Widmann G,Jaschke W,Weinlich G

    更新日期:2016-08-01 00:00:00

  • Efficacy and safety of a novel vascular closure device (Glubran 2 seal) after diagnostic and interventional angiography in patients with peripheral arterial occlusive disease.

    abstract:PURPOSE:To prospectively evaluate safety and efficacy of a novel vascular closure device (Glubran 2 Seal) after peripheral angiography in patients with peripheral arterial occlusive disease (PAOD). METHODS:From December 2010 to June 2011, all consecutive patients with PAOD undergoing peripheral angiography were prospe...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-012-0428-7

    authors: Del Corso A,Bargellini I,Cicorelli A,Perrone O,Leo M,Lunardi A,Alberti A,Tomei F,Cioni R,Ferrari M,Bartolozzi C

    更新日期:2013-04-01 00:00:00

  • Ultrasound-monitored laser angioplasty: preliminary clinical results.

    abstract::A novel coaxial catheter system for ultrasound (US)-guided, pulsed laser angioplasty was tested clinically in 4 patients with stenoses of the femoral and external iliac artery. The mean lesion length was 1.3 +/- 0.4 cm. The 9F multifiber laser catheter incorporated a 4.8F commercial intravascular US catheter and can b...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/BF02602985

    authors: Duda SH,Huppert PE,Kreis A,Karsch KR,Claussen CD

    更新日期:1993-03-01 00:00:00

  • Talc pleurodesis through small-bore percutaneous tubes.

    abstract::Pleurodesis using talc as the sclerosing agent is an effective procedure for preventing reaccumulation of malignant pleural effusions. Because of its thickness, the talc slurry is usually instilled through large bore (20-28 Fr), surgically placed thorocostomy tubes. However, these tubes often cause considerable patien...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s002709900422

    authors: Bloom AI,Wilson MW,Kerlan RK Jr,Gordon RL,LaBerge JM

    更新日期:1999-09-01 00:00:00

  • Microcatheter embolization of intractable idiopathic epistaxis.

    abstract:PURPOSE:To assess the efficacy and safety of microcatheter embolization in the treatment of intractable idiopathic epistaxis. METHODS:Thirty-seven patients underwent microcatheter embolization in 1991-1998. We evaluated retrospectively the technical and clinical outcome, the number of complications, the duration of em...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s002709900439

    authors: Leppänen M,Seppänen S,Laranne J,Kuoppala K

    更新日期:1999-11-01 00:00:00

  • Percutaneous radiofrequency ablation of lung tumors: difficulty withdrawing the hooks resulting in a split needle.

    abstract::We describe a most unusual problem of a split needle following a lung radiofrequency ablation (RFA) procedure. We encountered the problem when retracting the electrode hooks into the shaft at completion of the ablation. We describe the process we adopted to overcome this problem. Charring of the ablated tissue can cau...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-003-0087-9

    authors: Steinke K,King J,Glenn D,Morris DL

    更新日期:2003-11-01 00:00:00

  • Transjugular Intrahepatic Portosystemic Shunt Placement During Pregnancy: A Case Series of Five Patients.

    abstract:BACKGROUND AND AIMS:Complications of portal hypertension, such as variceal hemorrhage and ascites, are associated with significant increases in both mortality and complications during pregnancy. Transjugular intrahepatic portosystemic shunt (TIPS) is a well-established procedure for treating portal hypertension, but th...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-015-1053-z

    authors: Ingraham CR,Padia SA,Johnson GE,Easterling TR,Liou IW,Kanal KM,Valji K

    更新日期:2015-10-01 00:00:00

  • Endovascular treatment of epistaxis: indications, management, and outcome.

    abstract:OBJECTIVE:Epistaxis is a common clinical problem, and the majority of bleedings can be managed conservatively. However, due to extensive and sometimes life-threatening bleeding, further treatment, such as superselective embolization, may be required. We report our experience with endovascular treatment of life-threaten...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-011-0155-5

    authors: Strach K,Schröck A,Wilhelm K,Greschus S,Tschampa H,Möhlenbruch M,Naehle CP,Jakob M,Gerstner AO,Bootz F,Schild HH,Urbach H

    更新日期:2011-12-01 00:00:00

  • "Complete-transposition-like" coronary arterial pattern in single ventricle with inverted infundibulum and transposition of the great arteries.

    abstract::In 19 out of 28 cases of single ventricle with inverted infundibulum and 1-transposition of the great arteries the right coronary artery arose from the posterior aortic sinus, the right anterior aortic sinus being the noncoronary one. This coronary arterial pattern was described before only in association with d-trans...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/BF02552415

    authors: Schneeweiss A,Deutsch V,Blieden LC,Shem-Tov A,Neufeld HN

    更新日期:1981-01-01 00:00:00

  • Utility of covered stents for revision of aging failing synthetic hemodialysis grafts: a report of three cases.

    abstract::Three aging failing hemodialysis polytetrafluoroethylene bypass shunts, average age 44 months, previously percutaneously revised with balloon angioplasty, presented with pseudoaneurysms and recurrent thrombosis. All were treated with percutaneous covered stent placement within their affected limbs. One graft was ligat...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-003-0013-1

    authors: Silas AM,Bettmann MA

    更新日期:2003-11-01 00:00:00

  • Percutaneous drainage of 300 intraperitoneal abscesses with long-term follow-up.

    abstract::The purpose of the study was to evaluate the efficacy of percutaneous drainage of intraperitoneal abscesses with attention to recurrence and failure rates. A retrospective analysis of percutaneous treatment of 300 intraperitoneal abscesses in 255 patients (147 male, 108 female; average age: 38 years; range: 40 days to...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-004-0281-4

    authors: Akinci D,Akhan O,Ozmen MN,Karabulut N,Ozkan O,Cil BE,Karcaaltincaba M

    更新日期:2005-11-01 00:00:00

  • Thoracic Duct Embolization in Post-neck Dissection Chylous Leakage: A Case Series of Six Patients and Review of the Literature.

    abstract::Chylous leak is a serious complication of neck dissection. Patients are often managed conservatively, and failure of conservative management necessitates surgical management, which adds to their morbidity. We present a case series demonstrating the value of thoracic duct embolization (TDE) in management of patients wi...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00270-020-02475-9

    authors: Moussa AM,Maybody M,Gonzalez-Aguirre AJ,Buicko JL,Shaha AR,Santos E

    更新日期:2020-06-01 00:00:00

  • Regions of high wall stress can predict the future location of rupture of abdominal aortic aneurysm.

    abstract::Predicting the wall stress in abdominal aortic aneurysm (AAA) using computational modeling may be a useful adjunct to traditional clinical parameters that indicate the risk of rupture. Maximum diameter has been shown to have many limitations, and using current technology it is possible to provide a patient-specific co...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-014-0864-7

    authors: Doyle BJ,McGloughlin TM,Miller K,Powell JT,Norman PE

    更新日期:2014-06-01 00:00:00

  • Patient Evaluation and Preparation in Vascular and Interventional Radiology: What Every Interventional Radiologist Should Know (Part 1: Patient Assessment and Laboratory Tests).

    abstract::Performing an interventional procedure imposes a commitment on interventional radiologists to conduct the initial patient assessment, determine the best course of therapy, and provide long-term care after the procedure is completed. After patient referral, contact with the referring physician and multidisciplinary tea...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00270-015-1228-7

    authors: Taslakian B,Georges Sebaaly M,Al-Kutoubi A

    更新日期:2016-03-01 00:00:00

  • Nonsurgical fluoroscopically guided dacryocystoplasty of common canalicular obstructions.

    abstract:PURPOSE:To assess dacryocystoplasty in the treatment of epiphora due to obstructions of the common canaliculus. METHODS:Twenty patients with severe epiphora due to partial (n = 16) or complete (n = 4) obstruction of the common canaliculus underwent fluoroscopically guided dacryocystoplasty. In all cases of incomplete ...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s002709910001

    authors: Wilhelm KE,Hofer U,Textor HJ,Böker T,Strunk H,Schild HH

    更新日期:2000-01-01 00:00:00

  • A new balloon-expandable tantalum stent (Strecker-Stent) for the biliary system: preliminary experience.

    abstract::Placement of a balloon-expandable metallic stent (Strecker-Stent) for biliary drainage has been attempted in 30 patients. The stent was successfully implanted in 22 patients; in the remaining 8 patients, dilatation of the biliary stricture prior to stent placement was inadequate and delivery of the Strecker-Stent was,...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/BF02734118

    authors: Jaschke W,Klose KJ,Strecker EP

    更新日期:1992-11-01 00:00:00

  • Will X-ray Safety Glasses Become Mandatory for Radiological Vascular Interventions?

    abstract:PURPOSE:The annual permissible radiation ocular lens dose has been reduced to 20 millisieverts (mSv) in the current European directive 2013/59/Euratom. The aim of this study was to evaluate the personal radiation dose for vascular interventions with special focus on ocular lens dose. MATERIALS AND METHODS:From May 201...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-018-1960-x

    authors: Thomas RP,Grau M,Eldergash O,Kowald T,Schnabel J,Szczechowicz M,Chavan A

    更新日期:2018-07-01 00:00:00

  • Simplified Endovascular Deep Venous Arterialization for Non-option CLI Patients by Percutaneous Direct Needle Puncture of Tibial Artery and Vein Under Ultrasound Guidance (AV Spear Technique).

    abstract::The following case report describes the AV spear technique for percutaneous deep venous arterialization. After an ultrasound survey was performed to find the puncture point adjacent to the ankle joint where the posterior tibial vein (PTV) runs superficially to the posterior tibial artery (PTA), percutaneous penetratio...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-019-02388-2

    authors: Ichihashi S,Shimohara Y,Bolstad F,Iwakoshi S,Kichikawa K

    更新日期:2020-02-01 00:00:00

  • Short-term Safety and Quality of Life Outcomes Following Radioembolization in Primary and Secondary Liver Tumours: a Multi-centre Analysis of 200 Patients in France.

    abstract:PURPOSE:Radioembolization has emerged as a treatment modality for patients with primary and secondary liver tumours. This observational study CIRT-FR (CIRSE Registry for SIR-Spheres Therapy in France) aims to evaluate real-life clinical practice on all patients treated with transarterial radioembolization (TARE) using ...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-020-02643-x

    authors: Loffroy R,Ronot M,Greget M,Bouvier A,Mastier C,Sengel C,Tselikas L,Arnold D,Maleux G,Pelage JP,Pellerin O,Peynircioglu B,Sangro B,Schaefer N,Urdániz M,Kaufmann N,Bilbao JI,Helmberger T,Vilgrain V,CIRT-FR Principal I

    更新日期:2021-01-01 00:00:00

  • Transvenous Fogarty balloon catheter occlusion of an iatrogenic innominate artery to innominate vein fistula.

    abstract::Transvenous embolization therapy is reported in a patient who developed a fistula from the innominate artery to the innominate vein as a complication of permanent cardiac pacemaker insertion. A transarterial approach at occlusion was unfavorable due to previous difficult catheterizations, and the patient's poor clinic...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/BF02629165

    authors: Patterson RD,Tomsick TA,Wilson JH,Frey RT,Deak A,Schreiber T

    更新日期:1993-09-01 00:00:00

  • Acute Thrombus Burden on Coated Flow Diverters Assessed by High Frequency Optical Coherence Tomography.

    abstract:PURPOSE:The implantation of flow diverters requires administration of dual anti-platelet therapy, posing the potential for complications. The p48MW HPC (phenox, Bochüm, Germany) hydrophilic-coated flow diverting stent is designed to be anti-thrombotic, thus opening the potential for single anti-platelet therapy. We dep...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-020-02482-w

    authors: King RM,Langan ET,Ughi GJ,Raskett CM,Puri AS,Henkes H,Gounis MJ

    更新日期:2020-08-01 00:00:00

  • Left femoral vein approach for the percutaneous placement of the Bird's Nest Filter.

    abstract::The Bird's Nest Filter femoral catheter set has proven to be too short in some patients to permit placement in close proximity to the renal veins via the left femoral vein approach. The use of the longer, but otherwise identical Bird's Nest Filter jugular catheter set via the left femoral vein eliminates this problem....

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/BF02577893

    authors: Taylor FC,Roehm JO

    更新日期:1991-11-01 00:00:00

  • Endovascular Management of Refractory Hepatic Encephalopathy Complication of Transjugular Intrahepatic Portosystemic Shunt (TIPS): Comprehensive Review and Clinical Practice Algorithm.

    abstract::Transjugular intrahepatic portosystemic shunt (TIPS) has evolved as an effective intervention for treatment of complications of portal hypertension. The use of polytetrafluoroethylene-covered stents have improved the patency of the shunts and diminished the incidence of TIPS dysfunction. However, TIPS-related refracto...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00270-015-1197-x

    authors: Pereira K,Carrion AF,Salsamendi J,Doshi M,Baker R,Kably I

    更新日期:2016-02-01 00:00:00