Comparison of self-expanding polyethylene terephthalate and metallic stents implanted in porcine iliac arteries.

Abstract:

PURPOSE:Comparison of the biocompatibility of self-expanding polyethylene terephthalate (PET) stents with self-expanding metallic stents (Wallstents). METHODS:Diameter- and length-matched PET stents and Wallstents were symmetrically implanted in the paired iliac arteries of 13 crossbred domestic swine. Stent deployment was studied angiographically and with intravascular ultrasound immediately after stent implantation. The angiographic stented lumen diameter was measured using quantitative vessel analysis before, immediately after stenting, and at 6-week follow-up. Cross-section histopathology and area morphometry were performed. RESULTS:Immediately poststenting, intravascular ultrasound revealed proximal dislocation of 5 of the 13 PET stents, whereas all metal stents were firmly embedded at the implantation site. At 6-week follow-up, three of the remaining PET stents were totally or subtotally occluded by organized thrombus, whereas all metal stents were patent. Compared with immediately poststenting, the angiographic lumen diameter within the five remaining PET stents was reduced by 30%, and that of the metallic stents was virtually unaltered (p < 0.02). This observation was confirmed by postmortem morphometry, wherein the PET-stented vessel segments a diameter stenosis of 40% was measured vs only 9% in the metallic stents (p < 0.0001). CONCLUSION:PET-stent deployment is difficult to control due to the lack of radiopacity of this stent. PET stents seem to be more thrombogenic and lead to significantly more neointimal proliferation than metallic stents.

authors

Wilczek K,Scheerder ID,Wang K,Verbeken E,Piessens J

doi

10.1007/BF02577615

subject

Has Abstract

pub_date

1996-05-01 00:00:00

pages

176-80

issue

3

eissn

0174-1551

issn

1432-086X

journal_volume

19

pub_type

杂志文章
  • Endovascular treatment of descending thoracic aortic aneurysms with the EndoFit stent-graft.

    abstract:OBJECTIVE:To evaluate the mid-term feasibility, efficacy, and durability of descending thoracic aortic aneurysm (DTAA) exclusion using the EndoFit device (LeMaitre Vascular). METHODS:Twenty-three (23) men (mean age 66 years) with a DTAA were admitted to our department for endovascular repair (21 were ASA III+ and 2 re...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-006-0168-7

    authors: Saratzis N,Saratzis A,Melas N,Ginis G,Lioupis A,Lykopoulos D,Lazaridis J,Kiskinis D

    更新日期:2007-03-01 00:00:00

  • Utility of covered stents for revision of aging failing synthetic hemodialysis grafts: a report of three cases.

    abstract::Three aging failing hemodialysis polytetrafluoroethylene bypass shunts, average age 44 months, previously percutaneously revised with balloon angioplasty, presented with pseudoaneurysms and recurrent thrombosis. All were treated with percutaneous covered stent placement within their affected limbs. One graft was ligat...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-003-0013-1

    authors: Silas AM,Bettmann MA

    更新日期:2003-11-01 00:00:00

  • Successful treatment with a covered stent and 6-year follow-up of biliary complication after liver transplantation.

    abstract::The role of covered stent in the management of biliary complications is not yet defined in liver transplant recipients. This Case Report presents a patient with anastomotic stricture and leakage with biloma treated with a covered stent 32 months following liver transplantation. Signs of in-stent restenosis developed 5...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-009-9558-y

    authors: Doros A,Németh A,Deák AP,Hartmann E,Gerlei Z,Fazakas J,Kóbori L

    更新日期:2010-04-01 00:00:00

  • Transjugular intrahepatic portosystemic shunt (TIPS) in the treatment of venous symptomatic chronic portal thrombosis in non-cirrhotic patients.

    abstract:PURPOSE:To present a series of cases of non-cirrhotic patients with symptomatic massive portal thrombosis treated by percutaneous techniques. All patients underwent a TIPS procedure in order to maintain the patency of the portal vein by facilitating the outflow. METHODS:A total of six patients were treated for thrombo...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-004-0241-z

    authors: Bilbao JI,Elorz M,Vivas I,Martínez-Cuesta A,Bastarrika G,Benito A

    更新日期:2004-09-01 00:00:00

  • Present status of axially angled angiocardiography.

    abstract::Axial angiography visualizes anatomical details of normal and pathological hearts not previously demonstrated by conventional angiography. Progress in the diagnosis of congenital heart malformations using axial projection technique has been reconsidered, emphasizing that the anatomical details of each congenital heart...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/BF02552817

    authors: Soto B,Coghlan CH,Bargeron LM

    更新日期:1984-01-01 00:00:00

  • Magnetic resonance-guided focused ultrasound ablation in abdominal moving organs: a feasibility study in selected cases of pancreatic and liver cancer.

    abstract:PURPOSE:This study was designed to evaluate preliminarily the feasibility and safety of magnetic resonance-guided focused ultrasound (MRgFUS) for treatment of solid tumors in the upper abdomen. METHODS:We enrolled one patient with hepatocellular carcinoma and two patients with pancreatic adenocarcinoma for MRgFUS abla...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-014-0861-x

    authors: Anzidei M,Napoli A,Sandolo F,Marincola BC,Di Martino M,Berloco P,Bosco S,Bezzi M,Catalano C

    更新日期:2014-12-01 00:00:00

  • Stereotactic radiofrequency ablation (SRFA) of liver lesions: technique effectiveness, safety, and interoperator performance.

    abstract:PURPOSE:To evaluate technique effectiveness, safety, and interoperator performance of stereotactic radiofrequency ablation (SRFA) of liver lesions. METHODS:Retrospective review including 90 consecutive patients from January 2008 to January 2010 with 106 computed tomography-guided SRFA sessions using both single and mu...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-011-0200-4

    authors: Widmann G,Schullian P,Haidu M,Bale R

    更新日期:2012-06-01 00:00:00

  • A newly developed perfused umbrella electrode for radiofrequency ablation: an ex vivo evaluation study in bovine liver.

    abstract::The purpose of this study was to evaluate the effectiveness of a newly developed perfused monopolar radiofrequency (RF) probe with an umbrella-shaped array. A perfused umbrella-shaped monopolar RF probe based on a LeVeen electrode (Boston Scientific Corp., Natick, MA, USA) with a 3-cm array diameter was developed. Fiv...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-007-9125-3

    authors: Bruners P,Pfeffer J,Kazim RM,Günther RW,Schmitz-Rode T,Mahnken AH

    更新日期:2007-09-01 00:00:00

  • Contralateral loop snare removal of a ruptured and entrapped angioplasty balloon.

    abstract::We describe a technique that extracted a ruptured angioplasty balloon which had become entrapped by a calcified left common iliac artery stenosis. The balloon catheter had been advanced crossover from the right and could not be retracted directly into a sheath across the aortic bifurcation. Therefore, a guidewire was ...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/BF02577632

    authors: Braun MA,Smith SJ,Merrill TN

    更新日期:1996-11-01 00:00:00

  • Percutaneous intraluminal recanalization of long, chronic superficial femoral and popliteal occlusions using the Frontrunner XP CTO device: a single-center experience.

    abstract::The purpose of this study was to examine the safety and efficacy of the Frontrunner XP CTO (chronic total occlusion) Catheter (Cordis) for recanalization of long femoropopliteal artery occlusions. A Frontrunner catheter was used to treat 26 CTOs in SFA after guidewire failure (68.3 +/- 8.8 years). Sixty-seven percent ...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-009-9700-x

    authors: Charalambous N,Schäfer PJ,Trentmann J,Hümme TH,Stöhring C,Müller-Hülsbeck S,Heller M,Jahnke T

    更新日期:2010-02-01 00:00:00

  • Percutaneous Fluoroscopic-Guided Creation of Neoanastomosis for the Treatment of Biliary Occlusions.

    abstract:PURPOSE:Complete biliary occlusions at different anatomic locations that are not amenable to surgical, endoscopic, or routine percutaneous methods pose a challenge to physicians. Biliary ductal neoanastomosis technique can play a very important role in solving such clinical problems. MATERIALS:Between October 2004 and...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-020-02544-z

    authors: Habibollahi P,Benjamin JL,X Bai H,Dagli MS,Shlansky-Goldberg RD

    更新日期:2020-11-01 00:00:00

  • Balloon-assisted coil embolization for large-necked renal artery aneurysms.

    abstract::An aneurysm of the right renal artery was discovered in a patient suffering from cerebral arterial angiodysplasia and arterial hypertension. The aneurysm was large necked, which made selective endovascular treatment very difficult. To perform the embolization of the aneurysm, a balloon remodelling technique was used. ...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s002700010049

    authors: Mounayer C,Aymard A,Saint-Maurice JP,Chapot R,Merland JJ,Houdart E

    更新日期:2000-05-01 00:00:00

  • Endovascular management of splenic artery aneurysms and pseudoaneurysms.

    abstract::Splenic artery aneurysms and pseudoaneurysms are being diagnosed with increasing frequency by modern imaging. The question of appropriate treatment--surgical or endovascular--arises more often. We review our experience and that of others as documented in the literature. The information available suggests that endovasc...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章,评审

    doi:10.1007/BF00571531

    authors: McDermott VG,Shlansky-Goldberg R,Cope C

    更新日期:1994-07-01 00:00:00

  • The road to bioabsorbable stents: reaching clinical reality?

    abstract::This article provides an overview of the evolution of revascularization devices since Grüntzig's initial introduction of balloon angioplasty in 1977. In-stent restenosis (ISR) is the major shortcoming of conventional (permanent-implant) stent therapy; even with the innovation and promising benefits of drug-eluting ste...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00270-004-0341-9

    authors: Erne P,Schier M,Resink TJ

    更新日期:2006-01-01 00:00:00

  • Catheter-directed thrombolysis with percutaneous rheolytic thrombectomy versus thrombolysis alone in upper and lower extremity deep vein thrombosis.

    abstract:PURPOSE:To compare the efficacy of catheter-directed thrombolysis (CDT) alone versus CDT with rheolytic percutaneous mechanical thrombectomy (PMT) for upper and lower extremity deep vein thrombosis (DVT). METHODS:A retrospective cohort of consecutive patients with acute iliofemoral or brachiosubclavian DVT treated wit...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-005-0341-4

    authors: Kim HS,Patra A,Paxton BE,Khan J,Streiff MB

    更新日期:2006-11-01 00:00:00

  • Entrapment of guide wire in an inferior vena cava filter: a technique for removal.

    abstract::Entrapment of a central venous catheter (CVC) guide wire in an inferior vena cava (IVC) filter is a rare, but reported complication during CVC placement. With the increasing use of vena cava filters (VCFs), this number will most likely continue to grow. The consequences of this complication can be serious, as continue...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 信件

    doi:10.1007/s00270-012-0374-4

    authors: Abdel-Aal AK,Saddekni S,Hamed MF,Fitzpatrick F

    更新日期:2013-04-01 00:00:00

  • Use of a snare wire to perform nephrostomy access in the presence of obstructive staghorn calculi.

    abstract::We describe a technique for gaining access to the central collecting system via a chosen calyx, utilizing an alternative entry point to that calyx. An Amplatz nitinol loop snare is then used to convert this access to a traditional approach. ...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:

    authors: Nosher JL,Siegel RL,Bodner LJ

    更新日期:1996-05-01 00:00:00

  • Digital subtraction angiography in renal transplant recipients.

    abstract::The renal transplant vascularity of 72 patients was investigated by intravenous digital subtraction angiography (IV DSA). The procedure was combined with selective venous renin sampling of the transplant and native kidneys to identify the source of hypertension in these patients. Abnormalities were found on IV DSA exa...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/BF02552439

    authors: Irving JD,Khoury GA

    更新日期:1983-01-01 00:00:00

  • An unusual left ventricular outflow pseudoaneurysm: usefulness of echocardiography and multidetector computed tomography for surgical repair.

    abstract::Left ventricular outflow tract (LVOT) pseudoaneurysm is a rare but potentially lethal complication, mainly after aortic root endocarditis or surgery. Usually it originates from a dehiscence in the mitral-aortic intervalvular fibrosa and it arises posteriorly to the aortic root. Due to these anatomical features, its im...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-008-9406-5

    authors: Da Col U,Ramoni E,Di Bella I,Ragni T

    更新日期:2009-01-01 00:00:00

  • Percutaneous transluminal coronary angioplasty: analysis of unsuccessful procedures as a guide toward improved results.

    abstract::Technical success in percutaneous transluminal coronary angioplasty (PTCA) is a function of patient selection, operator experience, and the capabilities of the angioplasty equipment employed. When unsuccessful PTCA occurs, it is the result of one of several factors: (1) a failure to cross the stenosis; (2) a failure t...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/BF02552308

    authors: Baim DS

    更新日期:1982-01-01 00:00:00

  • Biocompatibility, inflammatory response, and recannalization characteristics of nonradioactive resin microspheres: histological findings.

    abstract::Intra-arterial radiotherapy with yttrium-90 microspheres (radioembolization) is a therapeutic procedure exclusively applied to the liver that allows the direct delivery of high-dose radiation to liver tumors, by means of endovascular catheters, selectively placed within the tumor vasculature. The aim of the study was ...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-009-9592-9

    authors: Bilbao JI,de Martino A,de Luis E,Díaz-Dorronsoro L,Alonso-Burgos A,Martínez de la Cuesta A,Sangro B,García de Jalón JA

    更新日期:2009-07-01 00:00:00

  • Small cystic insulinoma: value of arterial stimulation venous sampling.

    abstract::Cystic insulinomas are rare, with only three cases having been reported in the literature. It is not difficult to determine the site of such neoplasms, as cystic insulinomas are usually 4-10 cm in diameter. We report a patient with a histologically confirmed cystic insulinoma. This case is unique because of the small ...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/BF02743540

    authors: Baba Y,Miyazono N,Nakajo M,Inoue H,Nishida H,Ueno K,Sagara K,Yasuda H,Hagiwara Y,Kijima F,Imamura H,Aikou T

    更新日期:1997-07-01 00:00:00

  • Use of a reperfusion catheter after angioplasty dissection for salvage of ischemic renal allograft: case report.

    abstract::Percutaneous transluminal angioplasty was performed on a right common iliac artery stenosis presumed to be causing renovascular hypertension in a patient with a renal allograft anastomosis to the right external iliac artery. This was complicated by an obstructive dissection resulting in acute threatening renal allogra...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/BF02577725

    authors: Kim D,Porter DH,Siegel JB,Shapiro ME,Strom TB,Glotzer DJ

    更新日期:1991-05-01 00:00:00

  • Pulmonary Thermal Ablation Enables Long Chemotherapy-Free Survival in Metastatic Colorectal Cancer Patients.

    abstract:BACKGROUND:Chemotherapy (ct) is the preferred treatment option in metastatic colorectal cancer (mCRC). The objective of the study was to determine the overall survival (OS), disease-free survival (DFS) and ct-free survival (CFS) of pulmonary thermal ablation (TA) and its place in the treatment of mCRC. PATIENTS AND ME...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-018-1939-7

    authors: Fonck M,Perez JT,Catena V,Becouarn Y,Cany L,Brudieux E,Vayre L,Texereau P,Le Brun-Ly V,Verger V,Brouste V,Bechade D,Buy X,Palussière J

    更新日期:2018-11-01 00:00:00

  • Dialysis access graft thrombolysis: randomized study of pulse-spray versus continuous urokinase infusion.

    abstract:PURPOSE:To compare pulse-spray to continuous-infusion thrombolysis with high-dose urokinase in thrombosed dialysis access grafts. METHODS:A prospective randomized controlled trial was performed. From August 1992 to September 1993, 30 thrombosed polytetrafluoroethylene (PTFE) grafts in 24 patients were included, 15 gra...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1007/s002709900229

    authors: Goodwin SC,Arora LC,Razavi MK,Sayre J,McNamara TO,Yoon C

    更新日期:1998-03-01 00:00:00

  • Final results of the protected superficial femoral artery trial using the FilterWire EZ system.

    abstract::The purpose of this study was to evaluate the safety and efficacy of debris-capture for distal protection using the FilterWire EZ Embolic Protection System (Boston Scientific, Mountain View, CA) with the additional aim to further define the incidence of distal embolization during superficial femoral artery (SFA) inter...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-010-9936-5

    authors: Müller-Hülsbeck S,Hümme TH,Philipp Schäfer J,Charalambous N,Paulsen F,Heller M,Jahnke T

    更新日期:2010-12-01 00:00:00

  • Instrumentation for magnetic resonance angiography.

    abstract::Magnetic resonance angiography (MRA) places high demands on instrumentation capabilities. Magnetic gradient strength capabilities, main magnetic field strength and homogeneity, and eddy current compensation all play a role in determining the quality of the flow studies. In addition, radiofrequency coil design and use ...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/BF02733895

    authors: Saloner D,Anderson CM

    更新日期:1992-01-01 00:00:00

  • Regions of high wall stress can predict the future location of rupture of abdominal aortic aneurysm.

    abstract::Predicting the wall stress in abdominal aortic aneurysm (AAA) using computational modeling may be a useful adjunct to traditional clinical parameters that indicate the risk of rupture. Maximum diameter has been shown to have many limitations, and using current technology it is possible to provide a patient-specific co...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-014-0864-7

    authors: Doyle BJ,McGloughlin TM,Miller K,Powell JT,Norman PE

    更新日期:2014-06-01 00:00:00

  • Volumetric analysis of right ventricular cadaver models viewed in axially angled projections.

    abstract::Axial cinematography of 15 cadaver cast models of the right ventricle was performed, using 16 different real and simulated single and biplane axial oblique projections. Heart volumes were then calculated by Dodge's area-length method and Ferlinz' method. In our volumetric studies of models, the smallest positive devia...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/BF02552633

    authors: Dübel HP,Romaniuk P,Tschapek A

    更新日期:1985-01-01 00:00:00

  • A migrated aortic stent graft causing erosive spondylopathy.

    abstract::We report about a patient presenting with back pain 4 months after an uneventful endovascular implantation of an aortic stent graft. Computed tomography scan revealed a migration of the stent with consecutive endoleakage, kink formation, and movement of the stent toward the spine, which caused destruction of the aorti...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-013-0695-y

    authors: Gestrich C,Probst C,Wilhelm K,Schiller W

    更新日期:2013-12-01 00:00:00