Use of 3-dimensional stereolithographic polymer models for heterotopic ossification surgical excision.

Abstract:

:Heterotopic ossification is a known complication of traumatic injuries. To minimize iatrogenic complications during excision, an understanding of anatomic relationships is essential. Current imaging modalities, such as computed tomography and plain radiographs, are limited to providing a 2-dimensional representation of a 3-dimensional problem. This study describes the benefits of 3-dimensional stereolithography in the perioperative management of symptomatic heterotopic ossification using models were that were fabricated based on high-resolution computed tomography scans. The models facilitated heterotopic ossification excision through frequent intraoperative reference, allowing the authors to avoid iatrogenic neurovascular injuries.

journal_name

Orthopedics

journal_title

Orthopedics

authors

Fleming ME,Waterman SS,Lewandowski LR,Chi BB

doi

10.3928/01477447-20130327-06

subject

Has Abstract

pub_date

2013-04-01 00:00:00

pages

282-6

issue

4

eissn

0147-7447

issn

1938-2367

journal_volume

36

pub_type

杂志文章
  • Dynamically unstable syndesmosis injuries.

    abstract::Distal tibiofibular syndesmosis injuries are complex injuries that often result in extended loss of playing time for athletes. Unstable syndesmosis injuries are uniformly reduced and stabilized by numerous methods. Controversy arises from syndesmosis injuries that are stable on stress radiographs but functionally unst...

    journal_title:Orthopedics

    pub_type: 杂志文章

    doi:10.3928/01477447-20130222-07

    authors: Metzler AV,Johnson DL

    更新日期:2013-03-01 00:00:00

  • Complications Associated With Bone Morphogenetic Protein in the Lumbar Spine.

    abstract::Complications associated with the use of recombinant human bone morphogenetic protein in the lumbar spine include retrograde ejaculation, ectopic bone formation, vertebral osteolysis and subsidence, postoperative radiculitis, and hematoma and seroma. These complications are controversial and remain widely debated. Thi...

    journal_title:Orthopedics

    pub_type: 杂志文章,评审

    doi:10.3928/01477447-20161213-06

    authors: Kang DG,Hsu WK,Lehman RA Jr

    更新日期:2017-03-01 00:00:00

  • Biomechanical comparison of interference screw and cortical button with screw hybrid technique for distal biceps brachii tendon repair.

    abstract::Various fixation techniques have been described for ruptured distal biceps tendons. The authors hypothesized that no significant differences would be found between the mean failure strength, maximum strength, and stiffness of the interference screw and hybrid technique. Fourteen fresh-frozen human cadaveric elbows wer...

    journal_title:Orthopedics

    pub_type: 杂志文章,随机对照试验

    doi:10.3928/01477447-20131021-17

    authors: Arianjam A,Camisa W,Leasure JM,Montgomery WH

    更新日期:2013-11-01 00:00:00

  • Multivariate analysis of prognostic factors in synovial sarcoma.

    abstract::Many studies have described the diversity of synovial sarcoma in terms of its biological characteristics and clinical features. Moreover, much effort has been expended on the identification of prognostic factors because of unpredictable behaviors of synovial sarcomas. However, with the exception of tumor size, publish...

    journal_title:Orthopedics

    pub_type: 杂志文章

    doi:10.3928/01477447-20090922-12

    authors: Koh KH,Cho EY,Kim DW,Seo SW

    更新日期:2009-11-01 00:00:00

  • Cortical evoked potentials in spinal surgery.

    abstract::Few complications of surgery are as devastating as paraplegia in a patient who has been operated on for correction of a spinal abnormality. Early warning of potential damage to the spinal cord is highly desirable. This is possible with cortical evoked potentials. It measures electroencephalographic activity after peri...

    journal_title:Orthopedics

    pub_type: 社论

    doi:10.3928/0147-7447-19840101-06

    authors: Faust D,Happel LT

    更新日期:1984-01-01 00:00:00

  • Finite element analysis of 3 posterior fixation techniques in the lumbar spine.

    abstract::This study compared the biomechanics of 3 fixation techniques: bilateral pedicle screw (BPS) fixation, unilateral pedicle screw (UPS) fixation, and UPS supplemented with translaminar facet screw (UPS+TLFS) fixation. The study was conducted in an L3-L5 finite element model. Three different finite element models were cr...

    journal_title:Orthopedics

    pub_type: 杂志文章

    doi:10.3928/01477447-20140430-54

    authors: Gong Z,Chen Z,Feng Z,Cao Y,Jiang C,Jiang X

    更新日期:2014-05-01 00:00:00

  • Major injuries occurring during use of a golf cart.

    abstract::Major trauma following a mishap with a golf cart is an unreported problem. This study details injury types and the various mechanisms by which the accidents occurred. Recommendations are made regarding preventive measures that should be observed for safe operation of a golf cart. Two hundred eighty orthopedic surgeons...

    journal_title:Orthopedics

    pub_type: 杂志文章

    doi:

    authors: Kelly EG

    更新日期:1996-06-01 00:00:00

  • The use of osteotaxis as a limb salvage procedure in severe compound injuries of the upper extremity.

    abstract::Osteotaxis has been proven to offer a means for limb stabilization even in the most severe cases of upper extremity injuries, especially in cases where extensive soft tissue injuries contraindícate internal fixation or plaster cast treatment. Our policy has been to use the osteotaxis treatment only in these severe cas...

    journal_title:Orthopedics

    pub_type: 社论

    doi:10.3928/0147-7447-19840401-16

    authors: Santavirta S,Karaharju E,Korkala O

    更新日期:1984-04-01 00:00:00

  • Chronic Antiplatelet Use Associated With Increased Blood Loss in Lumbar Spinal Surgery Despite Adherence to Protocols.

    abstract::There are conflicting reports regarding postoperative bleeding risks associated with discontinuation of antiplatelet therapy at least 7 days preoperatively. Most of the studies in the spine literature are based on surveys or anecdotal evidence. The majority of surgeons discontinue therapy 7 days preoperatively, but th...

    journal_title:Orthopedics

    pub_type: 杂志文章

    doi:10.3928/01477447-20160419-04

    authors: McCunniff PT,Young ES,Ahmadinia K,Kusin DJ,Ahn UM,Ahn NU

    更新日期:2016-07-01 00:00:00

  • Comparison of ACCP and AAOS guidelines for VTE prophylaxis after total hip and total knee arthroplasty.

    abstract::Orthopedists have expressed concerns regarding the utility for and applicability to their practices of guidelines from the American College of Chest Physicians (ACCP) for thromboprophylaxis in the settings of total hip and total knee arthroplasty (THA and TKA, respectively). These concerns include the acceptance by th...

    journal_title:Orthopedics

    pub_type: 杂志文章,实务指引

    doi:10.3928/01477447-20091103-52

    authors: Lachiewicz PF

    更新日期:2009-12-01 00:00:00

  • Medical Crowdfunding for Patients Undergoing Orthopedic Surgery.

    abstract::Crowdfunding for medical expenses is growing in popularity. Through several websites, patients create public campaign profiles to which donors can contribute. Research on medical crowdfunding is limited, and there have been no studies of crowdfunding in orthopedics. Active medical crowdfunding campaigns for orthopedic...

    journal_title:Orthopedics

    pub_type: 杂志文章

    doi:10.3928/01477447-20171114-04

    authors: Durand WM,Johnson JR,Eltorai AEM,Daniels AH

    更新日期:2018-01-01 00:00:00

  • Pyogenic arthritis due to bacteroides fragilis infection.

    abstract::The second reported case of pyogenic arthritis due to Bacteroides fragilis infection is presented. Some aspects of diagnosis and management are discussed. ...

    journal_title:Orthopedics

    pub_type: 社论

    doi:10.3928/0147-7447-19800401-05

    authors: Childers JC

    更新日期:1980-04-01 00:00:00

  • Once Annealed Highly Cross-Linked Polyethylene Exhibits Low Wear at 9 to 15 Years.

    abstract::A once annealed highly cross-linked polyethylene (HXLPE) was introduced in 1998. Concerns regarding its long-term performance and oxidative resistance exist because of the presence of retained free radicals. The authors studied 48 patients with 50 hip implants having an average age of 62 years. They were followed for ...

    journal_title:Orthopedics

    pub_type: 杂志文章

    doi:10.3928/01477447-20160414-03

    authors: D'Antonio J,Capello WN,Ramakrishnan R

    更新日期:2016-05-01 00:00:00

  • Biomechanical verification that PCL reconstruction is unnecessary in the muscle-stabilized knee.

    abstract::Treatment of isolated posterior cruciate ligament (PCL) injuries is controversial. This is due in part to the discrepancy between clinical and biomechanical studies in the literature. Clinically, isolated PCL injuries are treated nonoperatively, and patients do well as long as they have adequate quadriceps function. B...

    journal_title:Orthopedics

    pub_type: 杂志文章

    doi:10.3928/01477447-20100329-12

    authors: Sohn DH,Balasubramanian S,Demetropoulos C,Yang K,Guettler J,Jurist KA

    更新日期:2010-05-12 00:00:00

  • Kinematically versus mechanically aligned total knee arthroplasty.

    abstract::The purpose of this study was to compare 2 alignment methods for total knee arthroplasty (TKA): kinematic alignment with the use of patient-specific guides and mechanical alignment with conventional instruments. A randomized, controlled trial of 41 kinematically aligned and 41 mechanically aligned patients was conduct...

    journal_title:Orthopedics

    pub_type: 杂志文章,随机对照试验

    doi:10.3928/01477447-20120123-04

    authors: Dossett HG,Swartz GJ,Estrada NA,LeFevre GW,Kwasman BG

    更新日期:2012-02-17 00:00:00

  • The Role of High School Football Coverage in Resident Education.

    abstract::Athletic team coverage experience varies widely across orthopedic surgery residency programs in the United States. There is a paucity of literature regarding whether serving as a team physician contributes to resident education and whether it can be performed within the bounds of current work-hour restrictions. Reside...

    journal_title:Orthopedics

    pub_type: 杂志文章

    doi:10.3928/01477447-20200827-08

    authors: Salzler MJ,Stoker GE,Lunardini DJ,Harner CD

    更新日期:2020-11-01 00:00:00

  • Low back pain.

    abstract::This study attempts to define the validity of radiographic imaging for the diagnosis of low back pain. ...

    journal_title:Orthopedics

    pub_type: 杂志文章

    doi:10.3928/01477447-20060301-08

    authors: Stein H,Braun Y,Volpin G

    更新日期:2006-03-01 00:00:00

  • Simulation Training Improves Surgical Proficiency and Safety During Diagnostic Shoulder Arthroscopy Performed by Residents.

    abstract::Although virtual reality simulators have established construct validity, no studies have proven transfer of skills from a simulator to improved in vivo surgical skill. The current authors hypothesized that simulation training would improve residents' basic arthroscopic performance and safety. Twenty-two orthopedic sur...

    journal_title:Orthopedics

    pub_type: 杂志文章,随机对照试验

    doi:10.3928/01477447-20160427-02

    authors: Waterman BR,Martin KD,Cameron KL,Owens BD,Belmont PJ Jr

    更新日期:2016-05-01 00:00:00

  • Long-term Functional Outcomes of Nonoperatively Treated Highly Displaced Scapular Body and Neck Fractures.

    abstract::Historically, extra-articular scapular body fractures were treated nonsurgically, but displaced fractures of the glenoid neck can lead to dysfunction. Controversy exists regarding which extra-articular scapular fractures should be treated surgically; however, nonsurgical management of severely displaced scapular body ...

    journal_title:Orthopedics

    pub_type: 杂志文章

    doi:10.3928/01477447-20200314-05

    authors: Rajfer RA,Salopek T,Mosier BA,Miller MC,Altman GT

    更新日期:2020-05-01 00:00:00

  • The use of 2% glutaraldehyde as a disinfectant for arthroscopes used in septic joints.

    abstract::The objective of this study was to determine the effectiveness of 2% glutaraldehyde as a sterilant for arthroscopes that had been used in septic joints. The first part of the experiment determined the minimum inhibitory concentration and the minimum lethal concentration of the disinfectant for five organisms frequentl...

    journal_title:Orthopedics

    pub_type: 社论

    doi:10.3928/0147-7447-19840201-09

    authors: Shoji H,Gutierrez MM,Aldridge KE

    更新日期:1984-02-01 00:00:00

  • Radiologic bone remodeling pattern around DCPD-coated, metaphyseal-loading cementless short stems in elderly patients.

    abstract::Concerns exist regarding using short stems during total hip arthroplasties performed in elderly patients. For this study, the authors assessed sequential bone remodeling findings in metaphyseal-loading short stems using serial radiography. A total of 100 consecutive primary THAs using short stems were performed in pat...

    journal_title:Orthopedics

    pub_type: 杂志文章

    doi:10.3928/01477447-20140626-57

    authors: Oh KJ,Mishra A,Yang JH

    更新日期:2014-07-01 00:00:00

  • Minimally invasive plate osteosynthesis using a helical plate for metadiaphyseal complex fractures of the proximal humerus.

    abstract::Minimally invasive plate osteosynthesis (MIPO) has been used for humeral shaft fractures, but concerns exist about soft tissue injuries. The purpose of this study was to report the surgical technique and clinical outcomes of MIPO using a helical plate for metadiaphyseal complex humeral shaft fractures. Twelve patients...

    journal_title:Orthopedics

    pub_type: 临床试验,杂志文章

    doi:10.3928/01477447-20140225-55

    authors: Moon JG,Kwon HN,Biraris S,Shon WY

    更新日期:2014-03-01 00:00:00

  • Femoral neck shortening after internal fixation of a femoral neck fracture.

    abstract::This study assesses femoral neck shortening and its effect on gait pattern and muscle strength in patients with femoral neck fractures treated with internal fixation. Seventy-six patients from a multicenter randomized controlled trial participated. Patient characteristics and Short Form 12 and Western Ontario and McMa...

    journal_title:Orthopedics

    pub_type: 杂志文章,随机对照试验

    doi:10.3928/01477447-20130624-13

    authors: Zielinski SM,Keijsers NL,Praet SF,Heetveld MJ,Bhandari M,Wilssens JP,Patka P,Van Lieshout EM,FAITH Trial Investigators.

    更新日期:2013-07-01 00:00:00

  • Osteoporotic ankle fractures: an approach to operative management.

    abstract::The incidence of osteoporosis is increasing as the elderly population grows. Because these patients remain active, fragility fractures of the ankle are becoming more common. The literature indicates a relatively high complication rate for non-operative management of ankle fractures in this patient cohort, leading surg...

    journal_title:Orthopedics

    pub_type: 杂志文章,评审

    doi:10.3928/01477447-20131120-07

    authors: McKean J,Cuellar DO,Hak D,Mauffrey C

    更新日期:2013-12-01 00:00:00

  • Spinal posterior movement after posterior cervical decompression surgery: clinical findings and factors affecting postoperative functional recovery.

    abstract::This study investigated the posterior movement of the spinal cord after posterior decompression surgery and evaluated factors affecting postoperative functional recovery in patients with cervical spondylotic myelopathy (CSM). Thirty-two patients with CSM underwent posterior decompression from C3 to C7 through laminect...

    journal_title:Orthopedics

    pub_type: 杂志文章

    doi:10.3928/01477447-20111021-03

    authors: Xia G,Tian R,Xu T,Li H,Zhang X

    更新日期:2011-12-06 00:00:00

  • Ankle arthroscopy: approaches and technique.

    abstract::ABSTRACT; Arthroscopic visualization of the ankle is outlined, with particular attention to establishment of portals. ...

    journal_title:Orthopedics

    pub_type: 社论

    doi:10.3928/0147-7447-19830901-11

    authors: Gollehon DL,Drez D

    更新日期:1983-09-01 00:00:00

  • Meniscal tear biomechanics: loads across meniscal tears in human cadaveric knees.

    abstract::This study examined the forces during motion across human meniscal tears. Longitudinal cuts were created in 6 human cadaveric knees at the red-white junction of the medial and lateral menisci into which a pressure transducer was placed. Pressure data were gathered with the knees at neutral, internal rotation, and exte...

    journal_title:Orthopedics

    pub_type: 杂志文章

    doi:10.3928/01477447-20080401-32

    authors: Richards DP,Barber FA,Herbert MA

    更新日期:2008-04-01 00:00:00

  • Allograft alternatives: bone substitutes and beyond.

    abstract::Excessive wear debris, deep infection, periprosthetic fracture, and other causes can lead to bone loss associated with total joint replacements. When performing revisions, surgeons are often preoccupied by the failed implant and the method of replacement, and neglect an opportunity to replenish lost bone. Thus, when f...

    journal_title:Orthopedics

    pub_type: 杂志文章

    doi:10.3928/01477447-20100722-31

    authors: Goodman SB

    更新日期:2010-09-07 00:00:00

  • Patient Factors Associated With Methicillin-Resistant Staphylococcus aureus Septic Arthritis in Children.

    abstract::Staphylococcus aureus is the most common causative organism in pediatric septic arthritis, with methicillin-resistant Staphylococcus aureus (MRSA) being responsible for a significant portion of these infections. Early identification and initiation of proper treatment may improve outcomes by minimizing potential morbid...

    journal_title:Orthopedics

    pub_type: 杂志文章

    doi:10.3928/01477447-20180213-04

    authors: Bernstein DT,Haruno LS,Daram S,Dawson JR,Zhang W,Rosenfeld SB

    更新日期:2018-03-01 00:00:00

  • Deep vein thrombosis prophylaxis in the outpatient setting: preventing complications following hospital discharge.

    abstract::Venous thromboembolism is an important complication in patients undergoing major orthopedic surgery. Without prophylaxis, there is a 50% to 60% incidence of deep vein thrombosis (DVT), a 10% to 30% incidence of proximal vein thrombosis, and a 1% to 2% rate of fatal pulmonary embolism after total hip replacement. The i...

    journal_title:Orthopedics

    pub_type: 杂志文章

    doi:

    authors: Turpie AG

    更新日期:1995-07-01 00:00:00