US Time-Harmonic Elastography for the Early Detection of Glomerulonephritis.

Abstract:

:Background Glomerulonephritis refers to renal diseases characterized by glomerular and tubulointerstitial fibrosis. Multifrequency US time-harmonic elastography enables the noninvasive quantification of tissue elasticity. Purpose To assess the diagnostic performance of US time-harmonic elastography for the early detection of glomerulonephritis. Materials and Methods From August 2016 through May 2017, study participants with biopsy-proven glomerulonephritis were prospectively examined with US time-harmonic elastography. Participants were subdivided according to chronic kidney disease (CKD) stage. All participants underwent elastography of both kidneys to generate full-field-of-view maps of renal shear wave speed (SWS). SWS was determined separately for the whole renal parenchyma, cortex, and medulla and was correlated with quantitative B-mode findings such as renal length and parenchymal thickness. Diagnostic performance of renal elastography was assessed with receiver operating characteristic curve analysis. Results Fifty-three participants with glomerulonephritis (mean age ± standard deviation, 49 years ± 14) and 30 healthy volunteers (mean age, 37 years ± 11) were evaluated. Age-adjusted renal SWS was lower in participants with glomerulonephritis than in healthy volunteers in the parenchyma, cortex, and medulla, with mean values of 1.55 m/sec (95% confidence interval [CI]: 1.51 m/sec, 1.59 m/sec) and 1.69 m/sec (95% CI: 1.64 m/sec, 1.74 m/sec; P < .001), respectively, in parenchyma, 1.80 m/sec (95% CI: 1.75 m/sec, 1.84 m/sec) and 2.08 m/sec (95% CI: 2.02 m/sec, 2.13 m/sec; P < .001) in cortex, and 1.25 m/sec (95% CI: 1.21 m/sec, 1.29 m/sec) and 1.33 (95% CI: 1.27 m/sec, 1.38 m/sec; P = .03) in medulla. Age-adjusted renal cortex SWS was lower in participants with glomerulonephritis and stage 1 CKD (preserved renal function) than in healthy volunteers (mean, 1.88 [95% CI: 1.81, 1.96] vs 2.08 [95% CI: 2.02, 2.13]; P < .001). In participants with CKD, renal cortex SWS values showed a positive association with estimated glomerular filtration rate (n = 39; r = 0.56; P < .001). Exploratory diagnostic performance of US time-harmonic elastography (area under the receiver operating characteristic curve [AUC], 0.89; 95% CI: 0.82, 0.97) outperformed that of B-mode parameters such as parenchymal thickness (AUC, 0.64; 95% CI: 0.51, 0.77; P < .001) and renal length (AUC, 0.55; 95% CI: 0.40, 0.68; P < .001) in identifying glomerulonephritis. Conclusion US time-harmonic elastography depicts abnormal renal stiffness in glomerulonephritis, particularly among patients with early disease and preserved renal function. Advanced chronic kidney disease is associated with further cortical softening. Time-harmonic elastography outperforms B-mode-based size quantification. © RSNA, 2019 Online supplemental material is available for this article.

journal_name

Radiology

journal_title

Radiology

authors

Grossmann M,Tzschätzsch H,Lang ST,Guo J,Bruns A,Dürr M,Hoyer BF,Grittner U,Lerchbaumer M,Nguyen Trong M,Schultz M,Hamm B,Braun J,Sack I,Marticorena Garcia SR

doi

10.1148/radiol.2019182574

subject

Has Abstract

pub_date

2019-09-01 00:00:00

pages

676-684

issue

3

eissn

0033-8419

issn

1527-1315

journal_volume

292

pub_type

杂志文章
  • Alterations in gastric physiology caused by selective embolization and vasopressin infusion of the left gastric artery.

    abstract::Alterations in gastric physiology caused by selective embolization and vasopressin infusion of the left gastric artery were evaluated in 29 dogs. Gastric acidity was not significantly altered following Gelfoam embolization but decreased sharply with vasopressin infusion. These results suggest that the segmental occlus...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/120.3.533

    authors: Chuang VP,Reuter SR,Cho KJ,Schmidt RW

    更新日期:1976-09-01 00:00:00

  • The soleal line: a cause of tibial pseudoperiostitis.

    abstract::An unusually prominent soleal line (a normal anatomic variant) may mimic periosteal reaction along the posterior margin of the proximal tibial shaft. This area of pseudoperiostitis is differentiated from hyperostoses arising from the anterior tibial tubercle and the interosseous membrane. It is always associated with ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/119.1.79

    authors: Levine AH,Pais MJ,Berinson H,Amenta PS

    更新日期:1976-04-01 00:00:00

  • Evidence of neuronal injury outside the medial temporal lobe in temporal lobe epilepsy: N-acetylaspartate concentration reductions detected with multisection proton MR spectroscopic imaging--initial experience.

    abstract:PURPOSE:To determine whether magnetic resonance (MR) spectroscopic imaging reveals metabolic changes, especially decreased N-acetylaspartate (NAA) concentrations outside the medial temporal lobe in patients with mesial temporal lobe epilepsy (TLE), consistent with neuropathologic findings of extratemporal neuronal impa...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2261011668

    authors: Vermathen P,Laxer KD,Schuff N,Matson GB,Weiner MW

    更新日期:2003-01-01 00:00:00

  • The evolution of the basic concepts underlying the practice of radiotherapy from 1949 to 1977.

    abstract::In his overview of the history and theoretical developments of radiotherapy, the author stresses the following concepts: (a) sensitivity is not linked to histology but to the volume of cancer; (b) the dose must not necessarily be homogeneous in the target volume but related to varying volumes of cancer; (c) the fact t...

    journal_title:Radiology

    pub_type: 历史文章,杂志文章,评审

    doi:10.1148/127.1.3

    authors: Fletcher GH

    更新日期:1978-04-01 00:00:00

  • Rectal cancer: comparison of accuracy of local-regional staging with two- and three-dimensional preoperative 3-T MR imaging.

    abstract:PURPOSE:To compare the local-regional staging accuracy of the conventional two-dimensional (2D) T2-weighted imaging protocol and of the three-dimensional (3D) T2-weighted imaging protocol for preoperative magnetic resonance (MR) imaging in rectal cancer patients. MATERIALS AND METHODS:This retrospective study was appr...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.09090587

    authors: Kim H,Lim JS,Choi JY,Park J,Chung YE,Kim MJ,Choi E,Kim NK,Kim KW

    更新日期:2010-02-01 00:00:00

  • Imaging and intervention in acute pancreatitis.

    abstract::An International Symposium was held in Atlanta in 1992 to present the state of the art of diagnostic evaluation and management of acute pancreatitis and to agree on an acceptable series of clinical definitions for classifying the disease and its complications. The symposium was composed of 40 internationally recognize...

    journal_title:Radiology

    pub_type: 杂志文章,评审

    doi:10.1148/radiology.193.2.7972730

    authors: Balthazar EJ,Freeny PC,vanSonnenberg E

    更新日期:1994-11-01 00:00:00

  • Amplitude-modulated continuous arterial spin-labeling 3.0-T perfusion MR imaging with a single coil: feasibility study.

    abstract::Written informed consent was obtained prior to all human studies after the institutional review board approved the protocol. A continuous arterial spin-labeling technique with an amplitude-modulated control was implemented by using a single coil at 3.0 T. Adiabatic inversion efficiency at 3.0 T, comparable to that at ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2351031663

    authors: Wang J,Zhang Y,Wolf RL,Roc AC,Alsop DC,Detre JA

    更新日期:2005-04-01 00:00:00

  • Barium enema examination using a remote controlled positive and negative contrast media inflator.

    abstract::In a series of 30 patients, barium enema examination of the colon was performed via a remote controlled air and contrast media inflator. With this apparatus, introduction and elimination of air and barium into the colon can be accomplished at a freely adjustable rate of injection by remote control. Fluoroscopy time is...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/125.2.533

    authors: Hisamichi S,Masuda Y,Shirane A,Sugawara N,Gomi T,Oshiba S

    更新日期:1977-11-01 00:00:00

  • Value of selective second-look sonography by radiologists.

    abstract:PURPOSE:To assess the usefulness of sonography performed by radiologists after a review of the sonographer's findings. MATERIALS AND METHODS:A total of 398 sonograms were obtained in 392 patients. Sonographers presented preliminary images and impressions to radiologists, who performed additional imaging and recorded t...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.199.2.8668810

    authors: Tessler FN,Tublin ME,Peters JC,Jie T,Peters TL

    更新日期:1996-05-01 00:00:00

  • Breast disease: dynamic spiral MR imaging.

    abstract:PURPOSE:To compare various subjective, empiric, and pharmacokinetic methods for interpreting findings at dynamic magnetic resonance (MR) imaging of the breast. MATERIALS AND METHODS:Dynamic spiral breast MR imaging was performed in 52 women suspected of having or with known breast disease. Gadolinium-enhanced images w...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.209.2.9807580

    authors: Daniel BL,Yen YF,Glover GH,Ikeda DM,Birdwell RL,Sawyer-Glover AM,Black JW,Plevritis SK,Jeffrey SS,Herfkens RJ

    更新日期:1998-11-01 00:00:00

  • Pelvic actinomycosis.

    abstract::A case of actinomycosis involving the pelvic cavity is reported. The patient had a pelvic mass clinically and radiographically. Barium enema examination showed a mass with extrinsic compression and fixed narrowing of the rectum with mucosal irregularity. A computed tomographic scan showed a pelvic mass displacing the ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.148.2.6867330

    authors: Maloney JJ,Cho SR

    更新日期:1983-08-01 00:00:00

  • Uterine artery embolization in sheep: comparison of acute effects with polyvinyl alcohol particles and calibrated microspheres.

    abstract:PURPOSE:To compare the effects on the myometrium of polyvinyl alcohol (PVA) particles and calibrated microspheres (MS) in embolization of the uterine arteries in sheep. MATERIALS AND METHODS:Superselective and bilateral embolization of the uterine arteries was performed with PVA particles and calibrated MS within 24 h...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2242010847

    authors: Pelage JP,Laurent A,Wassef M,Bonneau M,Germain D,Rymer R,Flaud P,Martal J,Merland JJ

    更新日期:2002-08-01 00:00:00

  • Mammography with synchrotron radiation: phase-detection techniques.

    abstract::The authors evaluated the effect on mammographic examinations of the use of synchrotron radiation to detect phase-perturbation effects, which are higher than absorption effects for soft tissue in the energy range of 15-25 keV. Detection of phase-perturbation effects was possible because of the high degree of coherence...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.215.1.r00ap10286

    authors: Arfelli F,Bonvicini V,Bravin A,Cantatore G,Castelli E,Palma LD,Michiel MD,Fabrizioli M,Longo R,Menk RH,Olivo A,Pani S,Pontoni D,Poropat P,Prest M,Rashevsky A,Ratti M,Rigon L,Tromba G,Vacchi A,Vallazza E,Zanconat

    更新日期:2000-04-01 00:00:00

  • Surface coil assembly with switchable field of view.

    abstract::The authors designed and built an overlapping surface coil assembly for magnetic resonance imaging of the spine. A small and a large coil are included, and use of one can be switched to the other without need for patient repositioning. The images are not degraded, and screening studies can immediately be followed by d...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.164.3.3615890

    authors: Arakawa M,Krasnor S,Fehn J,McCarten B,Kaufman L

    更新日期:1987-09-01 00:00:00

  • Prostatic carcinoma and benign prostatic hyperplasia: MR imaging with histopathologic correlation.

    abstract::Twenty-eight patients with prostatic carcinoma who underwent magnetic resonance (MR) imaging and subsequent radical prostatectomy were studied. The resected prostates were sectioned axially, and the whole-mount prostatic specimen was compared with the corresponding MR images. The carcinoma could be identified in 20 ca...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.173.3.2479050

    authors: Kahn T,Bürrig K,Schmitz-Dräger B,Lewin JS,Fürst G,Mödder U

    更新日期:1989-12-01 00:00:00

  • Reference values for diagnostic radiology: application and impact.

    abstract::Reference values (RVs) are recommended by the American Association of Physicists in Medicine for four radiographic projections, computed tomography, fluoroscopy, and dental radiography. RVs are used to compare radiation doses from individual pieces of radiographic equipment with doses from similar equipment assessed i...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2352020016

    authors: Gray JE,Archer BR,Butler PF,Hobbs BB,Mettler FA Jr,Pizzutiello RJ Jr,Schueler BA,Strauss KJ,Suleiman OH,Yaffe MJ

    更新日期:2005-05-01 00:00:00

  • Bladder pseudomass following cystography-related bladder trauma.

    abstract::Transient sonographic abnormalities of the urinary bladder in children can be identified immediately after performance of voiding cystourethrography. Both cystic and solid masses may be mimicked by transient hematuria induced by minor, cystography-related trauma. After the bladder has been emptied and refilled, reexam...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.159.1.3513250

    authors: Markle BM,Catena L

    更新日期:1986-04-01 00:00:00

  • Bronchial web diagnosed by bronchography.

    abstract::Bronchial webs are rare lesions which often go unrecognized. The authors describe a patient who presented with right-lower-lobe bronchiectasis and at-electasis secondary to a web in the right-lower-lobe bronchus. This is the first known instance where such a lesion has been demonstrated by bronchography. The etiology ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/121.3.526

    authors: Patronas NJ,MacMahon H,Variakojis D

    更新日期:1976-12-01 00:00:00

  • Cervical radiculopathy: value of oblique MR imaging.

    abstract::Eighteen patients with cervical radiculopathy were entered into a prospective study to compare the accuracy of surface coil magnetic resonance (MR) imaging with that of metrizamide myelography and computed tomography (CT) with metrizamide. All MR studies included tailored axial and oblique images as well as routine sa...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.163.1.3823440

    authors: Modic MT,Masaryk TJ,Ross JS,Mulopulos GP,Bundschuh CV,Bohlman H

    更新日期:1987-04-01 00:00:00

  • Acute cholecystitis at T2-weighted and manganese-enhanced T1-weighted MR cholangiography: preliminary study.

    abstract::Twelve patients with symptoms of acute cholecystitis underwent heavily T2-weighted and mangafodipir trisodium-enhanced T1-weighted magnetic resonance (MR) cholangiography and cholescintigraphy before they underwent cholecystectomy. On T2-weighted MR cholangiographic images, morphologic evidence of outflow obstruction ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2272020207

    authors: Kim KW,Park MS,Yu JS,Chung JP,Ryu YH,Lee SI,Lee KS,Yoon SW,Lee KH

    更新日期:2003-05-01 00:00:00

  • Comparative trial of local pharmacotherapy with L-arginine, r-hirudin, and molsidomine to reduce restenosis after balloon angioplasty of stenotic rabbit iliac arteries.

    abstract:PURPOSE:To determine if local application of L-arginine, r-hirudin, or molsidomine significantly reduces restenosis after balloon angioplasty in stenotic rabbit iliac arteries. MATERIALS AND METHODS:Thirty-one male cholesterol-fed New Zealand white rabbits underwent balloon dilation of both common iliac arteries to in...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.219.3.r01jn27716

    authors: Kalinowski M,Alfke H,Bergen S,Klose KJ,Barry JJ,Wagner HJ

    更新日期:2001-06-01 00:00:00

  • Potential living liver donors: evaluation with an all-in-one protocol with multi-detector row CT.

    abstract::Multi-detector row computed tomography was performed for the preharvest evaluation of 14 potential living liver donors. Both a biliary contrast agent and a conventional iodinated contrast agent were administered intravenously. This protocol included acquisition of three subsequent scans and allowed accurate assessment...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2242011340

    authors: Schroeder T,Nadalin S,Stattaus J,Debatin JF,Malagó M,Ruehm SG

    更新日期:2002-08-01 00:00:00

  • Aplasia or hypoplasia of the pancreatic uncinate process: comparison in patients with and patients without intestinal nonrotation.

    abstract:PURPOSE:To investigate whether the pancreatic uncinate process is hypoplastic in patients with intestinal nonrotation, and to evaluate the association of hypoplasia or aplasia of the uncinate process with mesenteric vascular inversion. MATERIALS AND METHODS:Computed tomographic (CT) scans of the pancreas in five patie...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.205.2.9356640

    authors: Inoue Y,Nakamura H

    更新日期:1997-11-01 00:00:00

  • Prostatic evaluation by transrectal endosonography: detection of carcinoma.

    abstract::Transrectal endosonography is one of the most sensitive techniques to evaluate prostatic disease and is far more accurate than conventional sonography. A retrospective review of sonographic characteristics of the prostate was made in an attempt to define the ability of the technique to distinguish benign from malignan...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.158.1.3510030

    authors: Rifkin MD,Friedland GW,Shortliffe L

    更新日期:1986-01-01 00:00:00

  • Practical and technical considerations in establishing an intraoperative radiation therapy program in the community practice.

    abstract::The Radiation Oncology Center in Sacramento, California, has developed a procedure for establishing an intraoperative radiation therapy facility in a community practice. The logistics pertaining to personnel, equipment, physical measurements, and quality assurance are presented. Particular emphasis is given to the mos...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.168.1.3380970

    authors: Wolkov HB,Chenery SG,Asche DR,McPeek EC,Hanks GE,Holmes TW

    更新日期:1988-07-01 00:00:00

  • 99mTc-DTPA and 131I-hippuran findings in liver transplant recipients treated with cyclosporin A.

    abstract::The effects of cyclosporin A (CyA), an immunosuppressive agent that is potentially nephrotoxic, on the kidneys of 9 liver transplant recipients were studied with serial 99mTc-DTPA and 131I-hippuran scans. In addition, renal function was determined by measuring serum creatinine levels during the second postoperative we...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.142.1.7031760

    authors: Klintmalm GB,Klingensmith WC 3rd,Iwatsuki S,Schröter GP,Starzl TE

    更新日期:1982-01-01 00:00:00

  • Brain MR imaging at ultra-low radiofrequency power.

    abstract:PURPOSE:To explore the lower limits for radiofrequency (RF) power-induced specific absorption rate (SAR) achievable at 1.5 T for brain magnetic resonance (MR) imaging without loss of tissue signal or contrast present in high-SAR clinical imaging in order to create a potentially viable MR method at ultra-low RF power to...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.11092445

    authors: Sarkar SN,Alsop DC,Madhuranthakam AJ,Busse RF,Robson PM,Rofsky NM,Hackney DB

    更新日期:2011-05-01 00:00:00

  • The computerized diagnostic radiology department: update 1982.

    abstract::The small digital computer is becoming ever more powerful, reliable, and inexpensive. Diagnostic radiology and the computer are becoming more intertwined. During the past decade, computed tomography (CT) has achieved outstanding success. CT and other digital image systems that are capable of computer manipulation, sto...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.145.2.7134470

    authors: Barnhard HJ,Lane GB

    更新日期:1982-11-01 00:00:00

  • Pulmonary sequestration: diagnosis with color Doppler sonography and a new theory of associated hydrothorax.

    abstract::The diagnosis of pulmonary sequestration has traditionally relied on angiographic demonstration of a systemic artery to the sequestered lung tissue. Rarely, extralobar sequestration can be associated with tension hydrothorax, which in the past has invariably led to fetal hydrops and death. The authors report the cases...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.180.3.1871300

    authors: Hernanz-Schulman M,Stein SM,Neblett WW,Atkinson JB,Kirchner SG,Heller RM,Merrill WH,Fleischer AC

    更新日期:1991-09-01 00:00:00

  • Orthotopic Esophageal Cancers: Intraesophageal Hyperthermia-enhanced Direct Chemotherapy in Rats.

    abstract::Purpose To determine the feasibility of using intraesophageal radiofrequency (RF) hyperthermia to enhance local chemotherapy in a rat model with orthotopic esophageal squamous cancers. Materials and Methods The animal protocol was approved by the institutional animal care and use committee and the institutional review...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2016152281

    authors: Shi Y,Zhang F,Bai Z,Wang J,Qiu L,Li Y,Meng Y,Valji K,Yang X

    更新日期:2017-01-01 00:00:00