Capsular visualization in lipohemarthrosis of the knee.

Abstract:

:A new sign for the diagnosis of lipohemarthrosis on vertical beam lateral knee radiographs depends upon visualization of the joint capsule due to the presence of fat lying both within and outside of the joint. Recognition of lipohemarthrosis on routine knee radiographs may aid in the diagnosis of subtle tibial plateau fractures.

journal_name

Radiology

journal_title

Radiology

authors

Sacks BA,Rosenthal DI,Hall FM

doi

10.1148/122.1.31

subject

Has Abstract

pub_date

1977-01-01 00:00:00

pages

31-2

issue

1

eissn

0033-8419

issn

1527-1315

journal_volume

122

pub_type

杂志文章
  • Beyond the Cuff: MR Imaging of Labroligamentous Injuries in the Athletic Shoulder.

    abstract::Shoulder disease is common in the athletic population and may arise as a consequence of a single traumatic episode or multiple repeated events. Associated labroligamentous injuries can result in substantial disability. Specific athletic and occupational activities result in predictable injury patterns. Imaging in gene...

    journal_title:Radiology

    pub_type: 杂志文章,评审

    doi:10.1148/radiol.2015150364

    authors: Roy EA,Cheyne I,Andrews GT,Forster BB

    更新日期:2016-02-01 00:00:00

  • Percutaneous biliary drainage: complications of 118 consecutive catheterizations.

    abstract::We have reviewed our experience with 118 biliary catheterization procedures in 109 patients from 1979 to 1984. Major complications (septic shock, hemorrhage, subphrenic abscess, and formation of an arteriovenous fistula) occurred in five patients (4.2%), three of whom died (2.5%). Minor complications occurred in 41 pa...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.158.1.3940380

    authors: Hamlin JA,Friedman M,Stein MG,Bray JF

    更新日期:1986-01-01 00:00:00

  • Trisomy 9p, a chromosome aberration with distinct radiologic findings.

    abstract::Radiographic analysis of 33 cases of trisomy 9p (21 familial, 12 nonfamilial) disclosed consistent abnormalities in the hands, feet, and pelvic bones, with one exception (subsequently considered a misdiagnosis). Most of the abnormalities were present only during the period of epiphyseal growth and occurred with simila...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/130.1.125

    authors: Schinzel A

    更新日期:1979-01-01 00:00:00

  • Laparoscopic and open partial nephrectomy: frequency and long-term follow-up of postoperative collections.

    abstract:PURPOSE:To compare imaging findings between laproscopic and open partial nephrectomy at 6 months after surgery and to follow the evolution of the findings over time. MATERIALS AND METHODS:This HIPAA-compliant retrospective study had institutional review board approval and consent was waived. A surgical database was cr...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.10091256

    authors: Hecht EM,Bennett GL,Brown KW,Robbins D,Hyams ES,Taneja SS,Stifelman MA

    更新日期:2010-05-01 00:00:00

  • Clinical and dosimetric considerations in the radiation treatment of breast cancer.

    abstract::Preliminary results indicate that film dosimetry is a simple and precise method of determining volume dose distributions. Calculated dose distributions using computers or estimations of surface dose using TLD dosimeters are within 5% of the measured dose. Initial attempts to find suitable alternate techniques tailored...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/120.3.725

    authors: Mansfield CM,Ayyangar K,Suntharalingam N

    更新日期:1976-09-01 00:00:00

  • Budd-Chiari syndrome: technical, hemodynamic, and clinical results of treatment with transjugular intrahepatic portosystemic shunt.

    abstract:PURPOSE:To evaluate use of the transjugular intrahepatic portosystemic shunt (TIPS) as a nonsurgical approach for the management of Budd-Chiari syndrome (BCS). MATERIALS AND METHODS:Twelve patients with fulminant (n = 2), subacute (n = 5), or chronic (n = 5) BCS underwent TIPS placement. Hepatic venous obstruction was...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.197.3.7480760

    authors: Blum U,Rössle M,Haag K,Ochs A,Blum HE,Hauenstein KH,Astinet F,Langer M

    更新日期:1995-12-01 00:00:00

  • The air-contrast stomach examination: an overview.

    abstract::An overview of current air-contrast stomach examination techniques is offered: (a) Hampton's technique which does not use distension; (b) the Japanese method which utilizes the relaxant drug Buscopan, good distension, and much patient rotation; (c) a third method in which no drugs are used but more distension is obtai...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/117.3.743

    authors: Miller RE

    更新日期:1975-12-01 00:00:00

  • Posttraumatic arterial priapism in children: management with embolization.

    abstract:PURPOSE:To evaluate selective embolization for management of posttraumatic priapism in preadolescent boys and color Doppler sonography for diagnosis of the causative lesion and for planning embolization. MATERIALS AND METHODS:Five preadolescent boys with posttraumatic priapism underwent selective angiography and embol...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.196.1.7784590

    authors: Miller SF,Chait PG,Burrows PE,Steckler RE,Khoury AE,McLorie GA,Connolly BL,Pereira JK

    更新日期:1995-07-01 00:00:00

  • Intimal fibromuscular dysplasia and Takayasu arteritis: delayed response to percutaneous transluminal renal angioplasty.

    abstract::Percutaneous transluminal renal angioplasty has been shown to be an effective technique to dilate renal artery lesions, particularly those due to fibromuscular dysplasia. However, four of 70 patients in this study experienced atypical responses to angioplasty. Their lesions initially resisted dilation and had incomple...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.157.3.2865770

    authors: Srur MF,Sos TA,Saddekni S,Cohn DJ,Rozenblit G,Wetter EB

    更新日期:1985-12-01 00:00:00

  • Biliary atresia and noncardiac polysplenic syndrome: US and surgical considerations.

    abstract::Ten percent of children with biliary atresia have an associated complex of anomalies, including polysplenia, azygous continuation of the inferior vena cava, preduodenal portal vein, hepatic arterial anomalies, and bilaterally bilobed lungs. These abnormalities will not be detected if the preoperative workup is limited...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.163.2.3550880

    authors: Abramson SJ,Berdon WE,Altman RP,Amodio JB,Levy J

    更新日期:1987-05-01 00:00:00

  • Cancer of the glottis: prognostic factors in radiation therapy.

    abstract::The authors conducted a multivariate analysis of the prognostic factors in 96 patients with early glottic cancer treated by radiation therapy. Of these, 73 had T1 and 23 had T2 tumor. The primary tumor was controlled in 82% of T1 and 74% of T2 lesions. Actuarial five-year survival rates were 87% for T1 and 74% for T2....

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.149.1.6611940

    authors: Mantravadi RV,Liebner EJ,Haas RE,Skolnik EM,Applebaum EL

    更新日期:1983-10-01 00:00:00

  • Hepatic colon cancer metastases in mice: dynamic in vivo correlation with hypoechoic rims visible at US.

    abstract:PURPOSE:To use videomicroscopy of tumor-bearing livers of live mice to depict tumors directly to determine the exact nature of rims seen on corresponding ultrasonographic (US) scans. MATERIALS AND METHODS:Seventy-six hepatic colorectal cancer metastases were studied in exteriorized livers of 18 mice by using intravita...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.215.3.r00jn16852

    authors: Kruskal JB,Thomas P,Nasser I,Cay O,Kane RA

    更新日期:2000-06-01 00:00:00

  • Electron-beam CT: use of a calibration phantom to reduce variability in calcium quantitation.

    abstract:PURPOSE:To measure scanner and patient variation in computed tomographic (CT) numbers for electron-beam CT and to determine the ability of calibration phantoms to reduce variability in calcium quantitation. MATERIALS AND METHODS:Two calibration phantoms were imaged to ensure longitudinal homogeneity and to determine t...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.196.1.7784560

    authors: McCollough CH,Kaufmann RB,Cameron BM,Katz DJ,Sheedy PF 2nd,Peyser PA

    更新日期:1995-07-01 00:00:00

  • Transfemoral catheterization: mechanical versus manual control of bleeding.

    abstract::This study compared hand-held arterial compression with compression by a mechanical clamp to achieve hemostasis following transfemoral catheterization in 3,255 patients from six different hospitals. The time spent in manual compression of the artery averaged 33.5 minutes compared with 19.9 minutes using the clamp. The...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.154.1.3880610

    authors: Semler HJ

    更新日期:1985-01-01 00:00:00

  • Quantification of the left ventricular volumes and function with cine MR imaging: comparison of geometric models with three-dimensional data.

    abstract::Acquisition and measurement of left ventricular (LV) volumes with a three-dimensional data set of cine magnetic resonance (MR) images from apex to base is a time-consuming process. Results of a study with 10 healthy volunteers and 10 patients with LV hypertrophy were prospectively evaluated. The heart was shown in the...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.188.2.8327680

    authors: Dulce MC,Mostbeck GH,Friese KK,Caputo GR,Higgins CB

    更新日期:1993-08-01 00:00:00

  • Intraarticular facet block: diagnostic test or therapeutic procedure?

    abstract::The specificity of the intraarticular facet block as a diagnostic test for facet joint disease is currently unknown. Capsular rupture with epidural and periarticular diffusion is probably responsible for many false positive findings. We found a comparatively low success rate of the procedure in 25 patients in whom max...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.151.2.6709900

    authors: Raymond J,Dumas JM

    更新日期:1984-05-01 00:00:00

  • F-18 fluorodeoxyglucose PET in vivo evaluation of pancreatic glucose metabolism for detection of pancreatic cancer.

    abstract:PURPOSE:To evaluate positron emission tomography (PET) with fluorine-18-labeled fluorodeoxyglucose (FDG) for detection of pancreatic cancer compared with computed tomography (CT) and ultrasonography (US). MATERIALS AND METHODS:Forty patients with suspected pancreatic cancer underwent static PET after intravenous injec...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.192.1.8208970

    authors: Bares R,Klever P,Hauptmann S,Hellwig D,Fass J,Cremerius U,Schumpelick V,Mittermayer C,Büll U

    更新日期:1994-07-01 00:00:00

  • Varicosity of the left renal ascending lumbar communicant vein: a pitfall in CT diagnosis.

    abstract::An anastomosis between the left renal and left ascending lumbar veins may appear as a mass on CT scans due to a varicosity where the veins separate. Intravenous injection of contrast material reveals the vascular nature of the mass. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.152.2.6739820

    authors: Lien HH,von Krogh J

    更新日期:1984-08-01 00:00:00

  • Computed tomography of spinal cord arteriovenous malformations.

    abstract::Computed tomography (CT) of the spine after intravenous contrast enhancement has been used in 4 patients with arteriovenous malformation (AVM) of the spinal cord. The enlarged, contrast-filled vessels constituting the malformation are visualized on CT scans. There was good correspondence between CT and selective angio...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/123.2.351

    authors: Di Chiro G,Doppman JL,Wener L

    更新日期:1977-05-01 00:00:00

  • Accuracy of fat-suppressed three-dimensional spoiled gradient-echo FLASH MR imaging in the detection of patellofemoral articular cartilage abnormalities.

    abstract:PURPOSE:To determine the accuracy of T1-weighted fat-suppressed (FS) three-dimensional (3D) fast low-angle shot (FLASH) magnetic resonance (MR) imaging for the detection of articular cartilage abnormalities of the patellofemoral joint. MATERIALS AND METHODS:Forty-one patients with suspected internal derangement of the...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.198.1.8539380

    authors: Recht MP,Piraino DW,Paletta GA,Schils JP,Belhobek GH

    更新日期:1996-01-01 00:00:00

  • The periportal collar: a CT sign of liver transplant rejection.

    abstract::A low-attenuation region around the peripheral portal tracts (periportal collar) was noted on 13 of 43 computed tomographic studies obtained in 17 patients who had undergone 20 orthotopic liver transplantations. This region was then correlated with acute liver transplant rejection. The periportal collar as a sign of r...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.165.1.3306790

    authors: Wechsler RJ,Munoz SJ,Needleman L,Kurtz AB,Miller CL,Yang SL,Maddrey WC,Jarrell BE

    更新日期:1987-10-01 00:00:00

  • Nerve rootlet avulsion. A complication of myelography using the Chynn needle.

    abstract::The authors report a case of traumatic removal of nerve tissue during myelography with the Chynn aspiration cannula. If such a situation occurs, the authors suggest making a second puncture at a different level. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/125.3.734

    authors: Brodey PA,London SS,Sung MA

    更新日期:1977-12-01 00:00:00

  • A data acquisition system for three-dimensional treatment planning.

    abstract::The authors describe a coordinate measuring device developed to simplify manual acquisition of the digital information required for computerized three-dimensional treatment planning. This system has been used for two years and shown to be both fast and accurate. The time needed to digitize contour data is reduced to a...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/115.1.187

    authors: Mantel J,Perry H,Weinkam JJ

    更新日期:1975-04-01 00:00:00

  • Septate versus bicornuate uteri: errors in imaging diagnosis.

    abstract::Since two müllerian defects, the septate and bicornuate uteri, are no longer repaired by means of the same operative approach, an accurate preoperative diagnosis of these anomalies is now critical. A septum can be removed by means of hysteroscopic metroplasty. However, repair of a bicornuate uterus still requires abdo...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.172.3.2528160

    authors: Reuter KL,Daly DC,Cohen SM

    更新日期:1989-09-01 00:00:00

  • Complications of arthrography.

    abstract::Arthrography is considered extremely safe since reactions to intraarticular contrast media are rare. We have only seen one severe complication in the performance of more than 2,000 arthrographic procedures. To determine the incidence of complications, a questionnaire was sent to 84 radiologists experienced in arthrogr...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.155.3.4001360

    authors: Newberg AH,Munn CS,Robbins AH

    更新日期:1985-06-01 00:00:00

  • Lymphoma: predictive value of Ga-67 scintigraphy after treatment.

    abstract::The negative predictive value (PV-) and positive predictive value (PV+) of gallium-67 scintigraphy and computed tomography (CT) were compared after treatment in 43 patients with Hodgkin disease and in 56 patients with non-Hodgkin lymphoma. The usefulness of these studies in predicting survival was also evaluated. In p...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.182.2.1732950

    authors: Front D,Ben-Haim S,Israel O,Epelbaum R,Haim N,Even-Sapir E,Kolodny GM,Robinson E

    更新日期:1992-02-01 00:00:00

  • MR hydrometry to assess exocrine function of the pancreas: initial results of noninvasive quantification of secretion.

    abstract:PURPOSE:To evaluate magnetic resonance (MR) hydrometry, a method of quantifying fluid amounts by using MR imaging, for assessing the exocrine function of the pancreas after stimulation with secretin. MATERIALS AND METHODS:Images were obtained with a single-shot turbo spin-echo sequence by using a 1.0-T magnet with a q...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.218.1.r01ja2061

    authors: Heverhagen JT,Müller D,Battmann A,Ishaque N,Boehm D,Katschinski M,Wagner HJ,Klose KJ

    更新日期:2001-01-01 00:00:00

  • Clinical and radiographic manifestations of aortoesophageal fistulas.

    abstract::Aneurysms of the thoracic aorta simulated primary esophageal disease both clinically and radiographically in 5 patients. Four had an aortoesophageal fistula at the time of presentation; endoscopic biopsy of a presumed esophageal tumor precipitated hematemesis in the fifth patient. In retrospect, the fistulas were demo...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.141.3.7302210

    authors: Baron RL,Koehler RE,Gutierrez FR,Forrest JV,Weyman PJ

    更新日期:1981-12-01 00:00:00

  • Two-view and single-view tomosynthesis versus full-field digital mammography: high-resolution X-ray imaging observer study.

    abstract:PURPOSE:To compare the diagnostic accuracy of two-dimensional (2D) full-field digital mammography with that of two-view (mediolateral and craniocaudal) and single-view (mediolateral oblique) tomosynthesis in an observer study involving two institutions. MATERIALS AND METHODS:Ethical committee approval was obtained. Al...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.11103514

    authors: Wallis MG,Moa E,Zanca F,Leifland K,Danielsson M

    更新日期:2012-03-01 00:00:00

  • In vivo high-resolution MR imaging of the skin in a whole-body system at 1.5 T.

    abstract::High-resolution magnetic resonance (MR) images of the skin were acquired with a whole-body MR system at 1.5 T by adding a specific imaging module: A saddle-shaped surface gradient coil was connected in place of one of the gradient coils of the system, and a surface radio-frequency coil with a 1.5-cm radius was placed ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.176.2.2367660

    authors: Bittoun J,Saint-Jalmes H,Querleux BG,Darrasse L,Jolivet O,Idy-Peretti I,Wartski M,Richard SB,Leveque JL

    更新日期:1990-08-01 00:00:00