Do first-generation highly crosslinked polyethylenes oxidize in vivo?

Abstract:

BACKGROUND:Highly crosslinked and thermally treated polyethylenes were clinically introduced to reduce wear and osteolysis. Although the crosslinking process improves the wear performance, it also introduces free radicals into the polymer that can subsequently oxidize. Thermal treatments have been implemented to reduce oxidation; however, the efficacy of these methods with regard to reducing in vivo oxidative degradation remains to be seen. Polyethylene oxidation is a concern because it can compromise the ultimate strength and ductility of the material. QUESTIONS/PURPOSES:We analyzed the oxidation, oxidation potential, and mechanical behavior of thermally treated highly crosslinked polyethylene retrieved acetabular liners. METHODS:Three hundred seven acetabular liners were collected from consecutive revision surgeries at six institutions over a 10-year period. Twenty-four were sterilized using nonionizing methods, 43 were sterilized in an inert environment, 80 were highly crosslinked and annealed, and 160 were highly crosslinked and remelted. Oxidation and oxidation potential were assessed by Fourier transmission infrared spectroscopy. Mechanical behavior was assessed by the small punch test. RESULTS:Oxidation and hydroperoxide (oxidation potential) indices were elevated in the annealed and gamma inert sterilized groups compared with those of the remelted liners and uncrosslinked gas sterilized controls, particularly at the rim. We also detected an increase in oxidation over time at the bearing surface of the remelted group. Ultimate strength of the polyethylene at the bearing surface was negatively correlated with implantation time for the annealed liners. CONCLUSIONS:Within the first decade of implantation, the clinical outlook for first-generation highly crosslinked polyethylene remains promising. However, ongoing research continues to be warranted for first-generation highly crosslinked polyethylene bearings to monitor the implications of elevated oxidation at the rim of annealed liners as well as to better understand the subtle changes in oxidation at the bearing surface of remelted liners that occur in vivo.

journal_name

Clin Orthop Relat Res

authors

MacDonald D,Sakona A,Ianuzzi A,Rimnac CM,Kurtz SM

doi

10.1007/s11999-010-1728-3

subject

Has Abstract

pub_date

2011-08-01 00:00:00

pages

2278-85

issue

8

eissn

0009-921X

issn

1528-1132

journal_volume

469

pub_type

杂志文章
  • Natural polyphenols enhance stability of crosslinked UHMWPE for joint implants.

    abstract:BACKGROUND:Radiation-crosslinked UHMWPE has been used for joint implants since the 1990s. Postirradiation remelting enhances oxidative stability, but with some loss in strength and toughness. Vitamin E-stabilized crosslinked UHMWPE has shown improved strength and stability as compared with irradiated and remelted UHMWP...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:10.1007/s11999-014-3850-0

    authors: Shen J,Gao G,Liu X,Fu J

    更新日期:2015-03-01 00:00:00

  • Influenza Vaccination Is Not Associated with Increased Number of Visits for Shoulder Pain.

    abstract:BACKGROUND:Shoulder injury from vaccination was approved for automatic compensation from the Vaccine Injury Compensation Program (VICP)-a federal government program started in 1988 to shield the manufacturers of childhood vaccines from liability. The approval was made on the basis of case reports rather than experiment...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:10.1097/CORR.0000000000001215

    authors: Gonzalez AI,Kortlever JTP,Moore MG,Ring DC

    更新日期:2020-10-01 00:00:00

  • A long femoral stem is not always required in hip arthroplasty for patients with proximal femur metastases.

    abstract:BACKGROUND:During hip arthroplasties for treating proximal femur metastases, a long femoral stem frequently is used, presumably protecting the entire femur against progression of the existing lesions or development of new lesions. However, it is unclear whether a long stem is really required. QUESTIONS/PURPOSES:We the...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:10.1007/s11999-013-2790-4

    authors: Xing Z,Moon BS,Satcher RL,Lin PP,Lewis VO

    更新日期:2013-05-01 00:00:00

  • Conversion of Hemiarthroplasty to THA Carries an Increased Risk of Reoperation Compared With Primary and Revision THA.

    abstract:BACKGROUND:There is limited information on the complications and costs of conversion THA after hemiarthroplasty for femoral neck fractures. Previous studies have found that patients undergoing conversion THA experience higher risk complications, but it has been difficult to quantify the risk because of small sample siz...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:10.1097/CORR.0000000000000702

    authors: Hernandez NM,Fruth KM,Larson DR,Kremers HM,Sierra RJ

    更新日期:2019-06-01 00:00:00

  • Sucrose, xylitol, and erythritol increase PMMA permeability for depot antibiotics.

    abstract::Release of antibiotics from antibiotic-loaded PMMA is dependent on its permeability. Loading PMMA with soluble particulate filler has been proposed to increase permeability and antibiotic release for beads and spacers. We therefore assessed particulate sucrose, xylitol, and erythritol as fillers to increase the permea...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:10.1097/BLO.0b013e3181123e90

    authors: McLaren AC,McLaren SG,Hickmon MK

    更新日期:2007-08-01 00:00:00

  • Imaging in bone lengthening. A review.

    abstract::Limb lengthening using callotasis needs careful preoperative planning and great care during the lengthening period. The most common method used to monitor limb lengthening is plain radiography, but the time of frame removal is still left to the judgment of the surgeon. This paper reviews some of the methods used exper...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章,评审

    doi:

    authors: Hughes TH,Maffulli N,Green V,Fixsen JA

    更新日期:1994-11-01 00:00:00

  • A minimally invasive stabilizing system for dorsal pelvic ring injuries.

    abstract:BACKGROUND:Open reduction and stabilization of dorsal pelvic ring injuries is accompanied by a high rate of soft tissue complications. Minimally invasive techniques have the potential to decrease soft tissue trauma, but the risk of iatrogenic nerve and vessel damage through the reduced surgical exposure should be consi...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:10.1007/s11999-011-1922-y

    authors: Dienstknecht T,Berner A,Lenich A,Nerlich M,Fuechtmeier B

    更新日期:2011-11-01 00:00:00

  • What factors predict improvements in outcomes scores and reoperations after the Bernese periacetabular osteotomy?

    abstract:BACKGROUND:The Bernese periacetabular osteotomy (PAO) has entered its fourth decade and is frequently used for corrective osteotomy in patients with acetabular dysplasia. Although our capacity to preserve the joint after corrective osteotomy is excellent, gaining a better understanding on how well patients function aft...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:10.1007/s11999-014-3980-4

    authors: Beaulé PE,Dowding C,Parker G,Ryu JJ

    更新日期:2015-02-01 00:00:00

  • Percutaneous fixation of pelvic ring disruptions.

    abstract::Percutaneous pelvic fixation is possible because intraoperative fluoroscopic imaging and other technologies have been refined. Anterior and posterior unstable pelvic ring disruptions are amenable to percutaneous fixation after closed manipulation or open reduction. Stable and safe fixation is achieved only after an ac...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章,评审

    doi:10.1097/00003086-200006000-00004

    authors: Routt ML Jr,Nork SE,Mills WJ

    更新日期:2000-06-01 00:00:00

  • Hydroxyapatite coated stems in younger and older patients with hip arthritis.

    abstract::A primary aim of research in total hip arthroplasty is to extend longevity through improved fixation and decreased wear and osteolysis. Age range of patients receiving hip implants is ever increasing as technology improves and average life span increases. The current report focuses on minimum 10-year results of a prox...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:10.1097/00003086-200212000-00011

    authors: Capello WN,D'Antonio JA,Feinberg JR,Manley MT

    更新日期:2002-12-01 00:00:00

  • Cervical alignment, range of motion, and instability after cervical laminoplasty.

    abstract::It has been reported that flexibility of the neck decreases after cervical laminoplasty. It also is known that kyphosis can be an unfavorable result after posterior decompression surgery of the cervical spine. To examine whether a decrease in cervical mobility resulting from contracture of the cervical spine helps pre...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:10.1097/00003086-200208000-00016

    authors: Maeda T,Arizono T,Saito T,Iwamoto Y

    更新日期:2002-08-01 00:00:00

  • Indications for surgical treatment of localized Ewing's sarcoma of bone.

    abstract::There has been considerable improvement in recent years i the prognosis for patients with localized Ewing's sarcoma of bone. This improvement largely stems from the use of radiation therapy to the primary lesion accompanied by aggressive adjuvant chemotherapy. With patients surviving longer, it has become evident that...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:

    authors: Pritchard DJ

    更新日期:1980-11-01 00:00:00

  • Type IV tibial tubercle fracture revisited: a case report.

    abstract::Tibial tubercle avulsions and proximal tibial physeal fractures are uncommon. An even more rare case was seen when an adolescent athlete presented with a combined Type III tibial tubercle avulsion and a Salter-Harris Type IV proximal tibial physeal fracture. There was no previous report in the literature of the combin...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:10.1097/00003086-200108000-00027

    authors: Curtis JF

    更新日期:2001-08-01 00:00:00

  • Analysis of survivorship after total hip arthroplasty using a ceramic head.

    abstract::To determine the clinical efficacy of an alumina ceramic head, 119 cemented total hip arthroplasties in 97 patients using an alumina head coupled with ethylene oxide gas sterilized polyethylene were reviewed. Eighty-two patients (101 hips) with greater than 10 years followup were evaluated clinically and radiographica...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:10.1097/00003086-200110000-00022

    authors: Haraguchi K,Sugano N,Nishii T,Sakai T,Yoshikawa H,Ohzono K

    更新日期:2001-10-01 00:00:00

  • Unicompartmental knee arthroplasty. Eight- to 12-year follow-up evaluation with survivorship analysis.

    abstract::One hundred consecutive unicondylar knee arthroplasties were reviewed after eight to 12 years of follow-up evaluation. Eighteen patients (19 knees) had died, four patients (four knees) were lost to follow-up evaluation, and 13 patients (13 knees) had revision. Survivorship analysis revealed 90% survivorship of the pro...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:

    authors: Scott RD,Cobb AG,McQueary FG,Thornhill TS

    更新日期:1991-10-01 00:00:00

  • Decreases in bone blood flow and bone material properties in aging Fischer-344 rats.

    abstract::The purpose of this study was to quantify precisely aging-induced changes in skeletal perfusion and bone mechanical properties in a small rodent model. Blood flow was measured in conscious juvenile (2 months old), adult (6 months old), and aged (24 months old) male Fischer-344 rats using radiolabeled microspheres. The...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:10.1097/00003086-200203000-00036

    authors: Bloomfield SA,Hogan HA,Delp MD

    更新日期:2002-03-01 00:00:00

  • A synopsis of surgery for rheumatoid arthritis (excluding the hand).

    abstract::Over the years, orthopedic surgery has become more involved in the care of the rheumatoid patient. A more active and aggressive attitude by orthopedic surgeons has thrown new light on the handling of the rheumatoid patient. Currently, the surgical treatment of rheumatoid arthritis is evaluated not only by the outcome ...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:

    authors: Goldie I

    更新日期:1984-12-01 00:00:00

  • Radiographic and morphologic studies of load-bearing porous-surfaced structured implants.

    abstract::Load-bearing porous-surfaced implants in dogs which failed were not incorporated by bone ingrowth. The implants were incorporated only by fibrous tissue ingrowth. Collagen fiber orientation within this fibrous tissue and Sharpey's fiber-like features at the interface between the fibrous tissue and a surrounding layer ...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:

    authors: Pilliar RM,Cameron HU,Welsh RP,Binnington AG

    更新日期:1981-05-01 00:00:00

  • IVC filters may prevent fatal pulmonary embolism in musculoskeletal tumor surgery.

    abstract:UNLABELLED:To determine whether inferior vena cava (IVC) filter placement protects patients with musculoskeletal tumors from fatal pulmonary embolisms (PE), we retrospectively analyzed the records of 81 patients who underwent surgery for pelvic and lower extremity malignancies. All 81 patients received an IVC filter an...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:10.1007/s11999-008-0607-7

    authors: Tuy B,Bhate C,Beebe K,Patterson F,Benevenia J

    更新日期:2009-01-01 00:00:00

  • Autoclaved autograft bone combined with vascularized bone and bone marrow.

    abstract::In this study, the authors investigated enhancing the results of autoclaved autograft bone by combining it with a vascularized bone graft and supplementing it with autogenous bone marrow for replacement of a 2-cm tibial defect in the rabbit model. The study was divided into 4 groups. Group I consisted of autoclaved au...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:

    authors: Taguchi Y,Pereira BP,Kour AK,Pho RW,Lee YS

    更新日期:1995-11-01 00:00:00

  • T1ρ Hip Cartilage Mapping in Assessing Patients With Cam Morphology: How Can We Optimize the Regions of Interest?

    abstract:BACKGROUND:T1ρ MRI has been shown feasible to detect the biochemical status of hip cartilage, but various region-of-interest strategies have been used, compromising the reproducibility and comparability between different institutions and studies. QUESTIONS/PURPOSES:The purposes of this study were (1) to determine repr...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:10.1007/s11999-016-5011-0

    authors: Anwander H,Rakhra KS,Melkus G,Beaulé PE

    更新日期:2017-04-01 00:00:00

  • Duration of symptoms and outcome of hemiresurfacing for hip osteonecrosis.

    abstract::Thirty-seven hips with Ficat Stage II, III, or early IV osteonecrosis were treated with hemiresurfacing. The purpose of this study is to analyze specifically the clinical and radiographic results of patients who had hemiresurfacing to refine the indications for the procedure and identify factors substantially affectin...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:10.1097/00003086-200104000-00018

    authors: Beaulé PE,Schmalzried TP,Campbell P,Dorey F,Amstutz HC

    更新日期:2001-04-01 00:00:00

  • Do ion levels in metal-on-metal hip resurfacing differ from those in metal-on-metal THA at long-term followup?

    abstract:BACKGROUND:Metal-on-metal hip resurfacing arthroplasty (MOM HR) has become an established alternative to traditional metal-on-metal total hip arthroplasty (MOM THA) for younger, more active patients. Nevertheless, concerns remain regarding wear and corrosion of the bearing surfaces and the resulting systemic metal ion ...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:10.1007/s11999-013-2981-z

    authors: Savarino L,Cadossi M,Chiarello E,Baldini N,Giannini S

    更新日期:2013-09-01 00:00:00

  • Unexplained fractures: child abuse or bone disease? A systematic review.

    abstract:BACKGROUND:Child abuse and neglect (CAN) is a serious problem that has major implications for the welfare of the child involved. Unexplained fractures are of particular concern to the orthopaedic surgeon, who must often consider alternative diagnoses to CAN. QUESTIONS/PURPOSES:We therefore (1) determined which bone di...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章,评审

    doi:10.1007/s11999-010-1578-z

    authors: Pandya NK,Baldwin K,Kamath AF,Wenger DR,Hosalkar HS

    更新日期:2011-03-01 00:00:00

  • Oxidative stress after muscle damage from immobilization and remobilization occurs locally and systemically.

    abstract::Higher oxidative stress reportedly plays a key role in muscle damage caused by immobilization and subsequent remobilization. However, we have no clear understanding regarding oxidative stress during immobilization and remobilization. The purpose of this study was to clarify the characteristics of oxidative stress by m...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:10.1097/01.blo.0000150464.29883.ca

    authors: Liu MJ,Li JX,Lee KM,Qin L,Chan KM

    更新日期:2005-05-01 00:00:00

  • Evaluation of the hip with pigmented villonodular synovitis. A case report.

    abstract::Pigmented villonodular synovitis (PVNS) is an uncommon disorder of the synovium that rarely involves the hip joint. The natural history of an untreated case of PVNS is presented herein. A young adult with a painful hip and destructive changes on plain roentgenograms requires further diagnostic evaluation. The relative...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:

    authors: Boyd AD Jr,Sledge CB

    更新日期:1992-02-01 00:00:00

  • A randomized comparison of all-polyethylene and metal-backed tibial components.

    abstract::Clinical failures of all-polyethylene tibial components in total knee arthroplasty generally have been failures of design, not materials. The current study was designed to compare a modern congruent all-polyethylene tibial component with a metal-backed tibial component with the same articular design and geometry. All ...

    journal_title:Clinical orthopaedics and related research

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1097/00003086-200011000-00015

    authors: Gioe TJ,Bowman KR

    更新日期:2000-11-01 00:00:00

  • Do Mesenchymal Stromal Cells Influence Microscopic Residual or Metastatic Osteosarcoma in a Murine Model?

    abstract:BACKGROUND:Mesenchymal stromal cells (MSCs) have been shown in rodent models to promote primary and pulmonary metastatic sarcoma growth when injected in the presence of gross tumor. In theory, this would limit their use in a clinical setting after limb salvage treatment for osteosarcoma. Although concerning, these mode...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:10.1007/s11999-015-4362-2

    authors: Aanstoos ME,Regan DP,Rose RJ,Chubb LS,Ehrhart NP

    更新日期:2016-03-01 00:00:00

  • Silver negative pressure dressing with vacuum-assisted closure of massive pelvic and extremity wounds.

    abstract:BACKGROUND:Massive soft tissue loss involving the pelvis and extremities from trauma, infections, and tumors remains a challenging and debilitating problem. Although vacuum-assisted closure (VAC) technology is effective in the management of soft tissue loss, the adjunct of a silver dressing in the setting of massive wo...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:10.1007/s11999-013-3123-3

    authors: Siegel HJ,Herrera DF,Gay J

    更新日期:2014-03-01 00:00:00

  • Missed or developmental dislocation of the hip.

    abstract::In 15 documented cases, subluxation or dislocation of the hip was discovered months or years after previous multiple normal physical examinations. The examiners were unique in that six were professors specializing in childrens' orthopedics, four were board-certified orthopedists, and five were pediatricians. An increa...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:

    authors: Ilfeld FW,Westin GW,Makin M

    更新日期:1986-02-01 00:00:00