Technique, complication, and long-term outcome for endovascular treatment of iliac artery occlusion.

Abstract:

:The aim of this study was to report technical details, procedure-related complications, and results of endovascular treatment in chronic iliac artery occlusion. Between 2001 and 2008, endovascular treatments of 127 chronic iliac artery occlusions in 118 patients (8 women and 110 men; mean age, 59 years) were retrospectively reviewed. The study was based on Ad Hoc Committee on Reporting Standards (Society for Vascular Surgery/International Society for Cardiovascular Surgery Standards). All occlusions were treated with stent placement with or without preliminary balloon angioplasty. Kaplan-Meier estimators were used to determine patency rates. Univariate and multivariate analyses were performed to determine variables affecting successful recanalization, major complications, early stent thrombosis (

authors

Ozkan U,Oguzkurt L,Tercan F

doi

10.1007/s00270-009-9691-7

subject

Has Abstract

pub_date

2010-02-01 00:00:00

pages

18-24

issue

1

eissn

0174-1551

issn

1432-086X

journal_volume

33

pub_type

杂志文章
  • A rare case of iatrogenic pseudoaneurysm of the left brachiocephalic vein after central venous catheterization treated with thrombin injection.

    abstract::Rupture of the central veins with venous pseudoaneurysm formation is an unusual complication of central venous catheterization. Only seven cases of brachiocephalic venous pseudoaneurysm have been reported in the literature (among these only one was secondary to central venous catheterization). Plain radiographic exami...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-013-0729-5

    authors: Elsaadany AM,Alaeddin FH,Alsuhaibani HA

    更新日期:2014-08-01 00:00:00

  • Systemic pulsatile pressure in type II endoleaks after stent grafting of experimental abdominal aortic aneurysms.

    abstract:PURPOSE:To investigate pressure and maximum rate of rise of systolic pressure (peak dP/dt) in completely excluded aneurysms and endoleaks to determine the hemodynamic impact of endoleaks. METHODS:In mongrel dogs (n = 36) experimental aneurysms were created by insertion of a patch (portion of rectus abdominis muscle sh...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-003-2689-7

    authors: Pitton MB,Schmenger P,Düber C,Neufang A,Thelen M

    更新日期:2003-05-01 00:00:00

  • Use of Accessory Hepatic Vein Intervention in the Treatment of Budd-Chiari Syndrome.

    abstract:PURPOSE:To evaluate the clinical value of accessory hepatic vein (AHV) intervention in the treatment of Budd-Chiari syndrome (BCS). PATIENTS AND METHODS:From August 2008 to July 2014, consecutive patients with BCS caused by obstruction of three hepatic veins (HVs) with or without obstruction of inferior vena cava (IVC...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-015-1105-4

    authors: Fu YF,Wei N,Wu Q,Zhang QQ,Cui YF,Xu H

    更新日期:2015-12-01 00:00:00

  • Impact of Genomic Mutation and Timing of Y90 Radioembolization in Colorectal Liver Metastases.

    abstract:PURPOSE:To investigate timing of Yttrium-90 radioembolization (Y90) during treatment course, genomics, and other clinical factors as predictors of overall survival (OS) in colorectal liver metastasis (CRLM) that have progressed on at least one line of chemotherapy. MATERIALS AND METHODS:This was a retrospective study ...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章,多中心研究

    doi:10.1007/s00270-020-02463-z

    authors: Dabrowiecki A,Sankhla T,Shinn K,Bercu ZL,Ermentrout M,Shaib W,Cardona K,Newsome J,Kokabi N

    更新日期:2020-07-01 00:00:00

  • Perigraft Plug Embolization of the Internal Iliac Artery and Implantation of a Bifurcated Stentgraft: One Treatment Option for Insufficient Tubular Stentgraft Repair of a Common Iliac Artery Aneurysm.

    abstract::We report an endovascular technique for the treatment of type Ia endoleak after a plain tubular stentgraft had been implanted for a large common iliac artery aneurysm with an insufficient proximal landing zone and without occlusion of the hypogastric in another hospital. CT follow-up showed an endoleak with continuous...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-015-1161-9

    authors: Goltz JP,Loesaus J,Frydrychowicz A,Barkhausen J,Wiedner M

    更新日期:2016-02-01 00:00:00

  • Effort thrombosis: role of interventional therapy.

    abstract::Effort thrombosis, a form of axillary-subclavian vein occlusion in young people, was identified in patients referred over a 5-year period. Eleven of 120 patients (9%) with venous occlusion from many causes had effort thrombosis. They were treated acutely with heparin and then by thrombolysis, angioplasty, surgical byp...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/BF02578635

    authors: Grassi CJ,Bettmann MA

    更新日期:1990-10-01 00:00:00

  • Embolization of the left gastric artery in the absence of angiographic extravasation.

    abstract::Nine high-risk patients with endoscopic evidence of bleeding from the left gastric artery territory without angiographic extravasation were embolized to prevent rebleeding. Three were embolized with Gelfoam particles, 1 with Gianturco coils, and 5 with Gelfoam plus coils. Three patients rebled; 2 were embolized with G...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/BF02577940

    authors: Morris DC,Nichols DM,Connell DG,Burhenne HJ

    更新日期:1986-01-01 00:00:00

  • Usefulness of Amplatzer Vascular Plug for Preoperative Embolization Before Distal Pancreatectomy with En Bloc Celiac Axis Resection.

    abstract:PURPOSE:We evaluated the usefulness of the Amplatzer vascular plug (AVP) for preoperative embolization before distal pancreatectomy with en bloc celiac axis resection (DP-CAR). MATERIALS AND METHODS:Between April 2010 and September 2017, 19 patients with locally advanced pancreatic body cancer underwent preoperative e...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-019-02233-6

    authors: Fuji T,Yamagami T,Fukumoto W,Baba Y,Chosa K,Ishikawa M,Iida M,Naito A,Murakami Y,Uemura K,Kondo N,Awai K

    更新日期:2019-09-01 00:00:00

  • Renal stenting from the radial artery: a novel approach.

    abstract:PURPOSE:To describe the technique and feasibility of renal artery angioplasty and stenting from the radial artery. METHODS:A series of 19 patients were evaluated for transradial renal artery intervention. Procedures were performed using carbon dioxide gas (CO2) as the preferred angiographic contrast agent. Interventio...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-001-0114-7

    authors: Kessel DO,Robertson I,Taylor EJ,Patel JV

    更新日期:2003-03-01 00:00:00

  • Abscopal Effects and Yttrium-90 Radioembolization.

    abstract::We present the case of an 80-year-old male with squamous cell carcinoma with bilobar hepatic metastases who underwent targeted Yttrium-90 radioembolization of the right hepatic lobe lesion. Subsequently, there was complete regression of the nontargeted, left hepatic lobe lesion. This may represent the first ever repor...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-015-1259-0

    authors: Ghodadra A,Bhatt S,Camacho JC,Kim HS

    更新日期:2016-07-01 00:00:00

  • Correction To: Where is the Origin of the Last Normal Branch from Feeding Artery of Pulmonary Arteriovenous Malformations?

    abstract::On page 1852, the first sentence of the second paragraph "In all PAVMs, the mean diameter of the feeding artery was 7.24 ± 0.015 mm, and the mean maximum diameter of the sac was 19.10 ± 0.585 mm" should be corrected to read as follows. ...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 已发布勘误

    doi:10.1007/s00270-019-02281-y

    authors: Maruno M,Kiyosue H,Hongo N,Matsumoto S,Mori H

    更新日期:2019-10-01 00:00:00

  • Endovascular revascularization of chronically thrombosed arteriovenous fistulas and grafts for hemodialysis: a retrospective study in 15 patients with 18 access sites.

    abstract::The current study retrospectively evaluated whether endovascular revascularization of chronically thrombosed and long-discarded vascular access sites for hemodialysis was feasible. Technical and clinical success rates, postintervention primary and secondary patency rates, and complications were reported. During a 1-ye...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-010-9926-7

    authors: Weng MJ,Chen MC,Chi WC,Liu YC,Liang HL,Pan HB

    更新日期:2011-04-01 00:00:00

  • Radiation Doses to Operators in Hepatobiliary Interventional Procedures.

    abstract:PURPOSE:The primary aim of this study is to provide a summary of operators' radiation doses during hepatobiliary fluoroscopic guided procedures. In addition, patient dose in these procedures was also documented. MATERIALS AND METHODS:A total of 283 transarterial chemoembolisation (TACE) and 302 biliary procedures, inc...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-017-1870-3

    authors: Degiorgio S,Gerasia R,Liotta F,Maruzzelli L,Cortis K,Miraglia R,Luca A

    更新日期:2018-05-01 00:00:00

  • High-Flow Vascular Malformation in the Sigmoid Mesentery Successfully Treated with a Combination of Transarterial and Transvenous Embolization.

    abstract::Mesenteric high-flow vascular malformation can cause various clinical symptoms and demand specific therapeutic interventions owing to its peculiar hemodynamics. We report a case of high-flow vascular malformation in the sigmoid mesentery which presented with ischemic colitis. The main trunk of the inferior mesenteric ...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-016-1431-1

    authors: Kamo M,Yagihashi K,Okamoto T,Nakamura K,Fujita Y,Kurihara Y

    更新日期:2016-12-01 00:00:00

  • Transcatheter Arterial Embolization for Postpartum Hemorrhage: Indications, Technique, Results, and Complications.

    abstract::Postpartum hemorrhage (PPH) is a potentially life-threatening condition, which needs multidisciplinary management. Uterine atony represents up to 80 % of all causes of PPH. Transcatheter arterial embolization (TAE) has now a well-established role in the management of severe PPH. TAE allows stopping the bleeding in 90 ...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00270-015-1054-y

    authors: Soyer P,Dohan A,Dautry R,Guerrache Y,Ricbourg A,Gayat E,Boudiaf M,Sirol M,Ledref O

    更新日期:2015-10-01 00:00:00

  • Successful Balloon-Assisted Hepatic Tract Embolization Using the Pull-Through Technique to Remove a Malpositioned Chest Tube Penetrating the Liver and into the Right Ventricle.

    abstract::Intra-abdominal injury is an uncommon complication of chest tube insertion. A 66-year-old man had empyema and underwent chest tube insertion for drainage. Massive hemorrhage occurred; the postprocedural radiograph showed the malpositioned chest tube in the mediastinum. Computed tomography scan showed that the tube's t...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-018-1974-4

    authors: Hamanaka K,Hirokawa Y,Itoh T,Yamasaki M,Hayashi K,Sawai S,Nishiyama K

    更新日期:2018-09-01 00:00:00

  • Diameters of pulmonary veins in normal children--an angiocardiographic study.

    abstract::The diameters of the pulmonary veins at their atrial junction were measured from cineangiocardiographic films in 27 children (mean height 128.5 cm) without heart disease. Right upper pulmonary veins and right lower pulmonary veins were measured in all 27 films. The left upper pulmonary veins could be measured in 23 ch...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/BF02575426

    authors: Robida A

    更新日期:1989-11-01 00:00:00

  • Successful embolization of a spontaneous mesocaval shunt using the Amplatzer Vascular Plug II.

    abstract::A 48-year-old man with alcoholic liver cirrhosis and hepatic encephalopathy was found to have a large, spontaneous mesocaval shunt. The shunt was successfully occluded with the use of an Amplatzer Vascular Plug. To our knowledge, this is the first report of the use of this device to embolize a mesocaval shunt involvin...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-009-9739-8

    authors: Boixadera H,Tomasello A,Quiroga S,Cordoba J,Perez M,Segarra A

    更新日期:2010-10-01 00:00:00

  • Transcatheter embolization of a renal arteriovenous fistula complicated by an aneurysm of the feeding renal artery.

    abstract::Renal arteriovenous fistula (AVF) is rare. Renal AVF complicated by aneurysm of the feeding artery presents a technical challenge for endovascular treatment. We report a case managed by covered stenting of the renal artery aneurysm, coil embolization of the fistula, and bare stenting of the aorta. ...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-006-0184-7

    authors: Kensella D,Kakani N,Pocock R,Thompson J,Cowan A,Watkinson A

    更新日期:2008-03-01 00:00:00

  • Development of a new coaxial balloon catheter system for balloon-occluded retrograde transvenous obliteration (B-RTO).

    abstract:PURPOSE:To develop a new coaxial balloon catheter system and evaluate its clinical feasibility for balloon-occluded retrograde transvenous obliteration (B-RTO). METHODS:A coaxial balloon catheter system was constructed with 9 Fr guiding balloon catheter and 5 Fr balloon catheter. A 5 Fr catheter has a high flexibility...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-005-0039-7

    authors: Tanoue S,Kiyosue H,Matsumoto S,Hori Y,Okahara M,Kashiwagi J,Mori H

    更新日期:2006-11-01 00:00:00

  • Validation of the Risk Prediction Models STATE-Score and START-Strategy to Guide TACE Treatment in Patients with Hepatocellular Carcinoma.

    abstract:PURPOSE:Several scoring systems that guide patients' treatment regimen for transarterial chemoembolization (TACE) of hepatocellular carcinoma (HCC) have been introduced, but none have gained widespread acceptance in clinical practice. The purpose of this study is to externally validate the Selection for TrAnsarterial c...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-017-1606-4

    authors: Mähringer-Kunz A,Kloeckner R,Pitton MB,Düber C,Schmidtmann I,Galle PR,Koch S,Weinmann A

    更新日期:2017-07-01 00:00:00

  • First clinical results with a new caval filter.

    abstract::A new percutaneous inferior venacaval filter was used in 15 patients. The filter is constructed of stainless steel wires formed into a helical basket and anchoring legs. It can be inserted through a 10F catheter in an antegrade or retrograde fashion and can also be retrieved percutaneously. In a follow-up period of up...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/BF02577978

    authors: Günther RW,Schild H,Hollman JP,Vorwerk D

    更新日期:1987-01-01 00:00:00

  • Arteriographic study of variant arterial anatomy of the upper extremities.

    abstract::Anatomic variations in the major arteries of the upper extremities have been reported in 11-24.4% of individuals. In a review of 100 upper extremity arteriograms, we found an overall incidence of 9%. High origin of the radial artery from the brachial artery was the most frequently encountered anomaly occurring in 7% o...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/BF02577379

    authors: Uglietta JP,Kadir S

    更新日期:1989-05-01 00:00:00

  • Electromagnetic-tracked biopsy under ultrasound guidance: preliminary results.

    abstract:PURPOSE:This study was designed to evaluate the accuracy and safety of electromagnetic needle tracking for sonographically guided percutaneous liver biopsies. METHODS:We performed 23 consecutive ultrasound-guided liver biopsies for liver nodules with an electromagnetic tracking of the needle. A sensor placed at the ti...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-011-0278-8

    authors: Hakime A,Deschamps F,De Carvalho EG,Barah A,Auperin A,De Baere T

    更新日期:2012-08-01 00:00:00

  • Use of a New Hybrid Heparin-Bonded Nitinol Ring Stent in the Popliteal Artery: Procedural and Mid-term Clinical and Anatomical Outcomes.

    abstract:PURPOSE:To report the immediate and mid-term clinical and anatomical outcomes of a novel, hybrid, heparin-bonded, nitinol ring stent (TIGRIS; Gore Medical) when used for the treatment of lesions located in the popliteal artery. MATERIALS AND METHODS:This was a prospective single-centre registry. Patients eligible for ...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-015-1113-4

    authors: Parthipun A,Diamantopoulos A,Kitrou P,Padayachee S,Karunanithy N,Ahmed I,Zayed H,Katsanos K

    更新日期:2015-08-01 00:00:00

  • Endovascular treatment of in-stent occlusion: new technique for recanalization of long superficial femoral artery occlusion (direct stent puncture technique).

    abstract::In-stent reocclusion is a frequent complication of endovascular treatment and stenting, especially in the superficial femoral artery. Neointimal hyperplasia is the main cause of this problem, but in many cases, it occurs as a result of the presence of stent strut fractures. The two treatment options are endovascular a...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-011-0260-5

    authors: Palena LM,Cester G,Manzi M

    更新日期:2012-04-01 00:00:00

  • Emergency endovascular treatment of abdominal aortic aneurysms: feasibility and results.

    abstract:PURPOSE:To assess the feasibility and effectiveness of emergency endovascular treatment of abdominal aortic aneurysms (AAAs). METHODS:During 36 months we treated, on an emergency basis, 30 AAAs with endovascular exclusion. In 21 hemodynamically stable patients preoperative CT angiography (CTA) was performed to confirm...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-005-0080-6

    authors: Laganà D,Carrafiello G,Mangini M,Fontana F,Caronno R,Castelli P,Cuffari S,Fugazzola C

    更新日期:2006-03-01 00:00:00

  • Transcatheter Arterial Embolization for Gastrointestinal Bleeding Secondary to Gastrointestinal Lymphoma.

    abstract:PURPOSE:To evaluate the effectiveness of transcatheter arterial embolization (TAE) for gastrointestinal (GI) bleeding caused by GI lymphoma. MATERIALS AND METHODS:The medical records of 11 patients who underwent TAE for GI bleeding caused by GI lymphoma between 2001 and 2015 were reviewed retrospectively. RESULTS:A t...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-016-1422-2

    authors: Zheng L,Shin JH,Han K,Tsauo J,Yoon HK,Ko GY,Shin JS,Sung KB

    更新日期:2016-11-01 00:00:00

  • Stereotactic Radiofrequency Ablation for Metastatic Melanoma to the Liver.

    abstract:PURPOSE:To evaluate the outcome of patients with melanoma liver metastasis treated with stereotactic radiofrequency ablation (SRFA). MATERIAL AND METHOD:Following IRB approval, a retrospective evaluation of the treatment of 20 patients with 75 melanoma liver metastases was performed. RESULTS:A median number of 2 lesi...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-016-1336-z

    authors: Bale R,Schullian P,Schmuth M,Widmann G,Jaschke W,Weinlich G

    更新日期:2016-08-01 00:00:00

  • Comparison of computed tomography and cineangiography in the demonstration of central pulmonary arteries in cyanotic congenital heart disease.

    abstract:PURPOSE:To assess the diagnostic accuracy of contrast-enhanced computed tomography (CT) for central pulmonary artery pathology in patients with cyanotic congenital heart disease (CCHD) and right ventricular outflow obstruction. METHODS:We compared contrast-enhanced CT and cine pulmonary arteriography in 24 patients in...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 临床试验,杂志文章

    doi:10.1007/BF02563901

    authors: Taneja K,Sharma S,Kumar K,Rajani M

    更新日期:1996-03-01 00:00:00