Biocompatibility, inflammatory response, and recannalization characteristics of nonradioactive resin microspheres: histological findings.

Abstract:

:Intra-arterial radiotherapy with yttrium-90 microspheres (radioembolization) is a therapeutic procedure exclusively applied to the liver that allows the direct delivery of high-dose radiation to liver tumors, by means of endovascular catheters, selectively placed within the tumor vasculature. The aim of the study was to describe the distribution of spheres within the precapillaries, inflammatory response, and recannalization characteristics after embolization with nonradioactive resin microspheres in the kidney and liver. We performed a partial embolization of the liver and kidney vessels in nine white pigs. The left renal and left hepatic arteries were catheterized and filled with nonradioactive resin microspheres. Embolization was defined as the initiation of near-stasis of blood flow, rather than total occlusion of the vessels. The hepatic circulation was not isolated so that the effects of reflux of microspheres into stomach could be observed. Animals were sacrificed at 48 h, 4 weeks, and 8 weeks, and tissue samples from the kidney, liver, lung, and stomach evaluated. Microscopic evaluation revealed clusters of 10-30 microspheres (15-30 microm in diameter) in the small vessels of the kidney (the arciform arteries, vasa recti, and glomerular afferent vessels) and liver. Aggregates were associated with focal ischemia and mild vascular wall damage. Occlusion of the small vessels was associated with a mild perivascular inflammatory reaction. After filling of the left hepatic artery with microspheres, there was some evidence of arteriovenous shunting into the lungs, and one case of cholecystitis and one case of marked gastritis and ulceration at the site of arterial occlusion due to the presence of clusters of microspheres. Beyond 48 h, microspheres were progressively integrated into the vascular wall by phagocytosis and the lumen recannalized. Eight-week evaluation found that the perivascular inflammatory reaction was mild. Liver cell damage, bile duct injury, and portal space fibrosis were not observed. In conclusion, resin microspheres (15-30 microm diameter) trigger virtually no inflammatory response in target tissues (liver and kidney). Clusters rather than individual microspheres were associated with a mild to moderate perivascular inflammatory reaction. There was no evidence of either a prolonged inflammatory reaction or fibrosis in the liver parenchyma following recannalization.

authors

Bilbao JI,de Martino A,de Luis E,Díaz-Dorronsoro L,Alonso-Burgos A,Martínez de la Cuesta A,Sangro B,García de Jalón JA

doi

10.1007/s00270-009-9592-9

subject

Has Abstract

pub_date

2009-07-01 00:00:00

pages

727-36

issue

4

eissn

0174-1551

issn

1432-086X

journal_volume

32

pub_type

杂志文章
  • Detachable balloon embolization of an arterioportal fistula following liver biopsy in a liver transplant recipient: a case report and review of literature.

    abstract::We report a case of an intrahepatic arterioportal fistula in a 61-year-old female liver transplant recipient. The patient presented with massive ascites 7 months after a percutaneous liver biopsy. A large fistula between the right hepatic artery and the right portal vein was diagnosed on color Doppler ultrasound and c...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-004-0193-3

    authors: Botelberge T,Van Vlierberghe H,Voet D,Defreyne L

    更新日期:2005-11-01 00:00:00

  • Challenging TIPS in Liver Transplant Recipients: The Pull-Through Technique to Address Piggyback Anastomosis.

    abstract:PURPOSE:The hepatic vein access during transjugular intrahepatic portosystemic shunt (TIPS) can be challenging in liver transplant recipient patients, especially when piggyback anastomosis was performed. We described a modified technique and reviewed the clinical outcomes of TIPS in transplanted patients. MATERIALS AN...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-018-1886-3

    authors: Schembri V,Cassinotto C,Panaro F,Delicque J,Pierredon MA,Piron L,Herrero A,Escal L,Ursic-Bedoya J,Guiu B

    更新日期:2018-05-01 00:00:00

  • Necrosis and apoptosis in hepatocellular carcinoma following low-dose versus high-dose preoperative chemoembolization.

    abstract::Our purpose was to study necrosis and apoptosis of hepatocellular carcinoma (HCC) cells after preoperative transcatheter arterial chemoembolization (TACE) with use of low-dose and high-dose anticancer drugs in HCCs. Fifty-four patients with advanced but surgically resectable HCC were studied. Thirty-four patients who ...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章,随机对照试验

    doi:10.1007/s00270-008-9379-4

    authors: Lu W,Li YH,He XF,Zhao JB,Chen Y,Mei QL

    更新日期:2008-11-01 00:00:00

  • Effect of Transcatheter Arterial Microembolization on Phantom Limb Pain Persisting for 17 Years.

    abstract::Phantom limb pain is a frequent consequence of the amputation; currently available treatments are far from satisfactory. The present report describes a case in which transcatheter arterial microembolization had a remarkable curative effect on phantom limb pain persisting for 17 years. The patient began feeling phantom...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-018-2109-7

    authors: Shibuya M,Yamamoto M,Okuno Y

    更新日期:2019-03-01 00:00:00

  • Interventional treatment of a symptomatic neonatal hepatic cavernous hemangioma using the Amplatzer vascular plug.

    abstract::Percutaneous intervention is one treatment option for symptomatic hepatic hemangioma in infants. We report the case of a newborn (birth weight 4060 g) with a large hepatic cavernous hemangioma, which presented early with high cardiac output failure due to arteriovenous shunting and signs of incipient Kasabach-Merritt ...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-006-0123-7

    authors: Kretschmar O,Knirsch W,Bernet V

    更新日期:2008-03-01 00:00:00

  • Freehand two-step CT-guided brain tumor biopsy: a fast and effective interventional procedure in selected patients.

    abstract:PURPOSE:To evaluate the efficacy and safety of CT-guided needle biopsy of brain lesions without a stereotactic device, and to determine the best possible indications for this technique. METHODS:From February 2001 to February 2004, 20 patients (12 men, 8 women; age 61-82 years) underwent CT-guided brain lesion biopsy. ...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-005-0015-2

    authors: Thanos L,Mylona S,Galani P,Kalioras V,Pomoni M,Batakis N

    更新日期:2006-03-01 00:00:00

  • Does Technical Success of Angioplasty in Dysfunctional Hemodialysis Accesses Correlate with Access Patency?

    abstract:PURPOSE:To study if <30 % residual stenosis post angioplasty (PTA) correlates with primary access circuit patency, and if any variables predict technical success. MATERIALS AND METHODS:A prospective observational study was performed between January 2009 and December 2012, wherein 76 patients underwent 154 PTA events i...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-016-1401-7

    authors: Sidhu A,Tan KT,Noel-Lamy M,Simons ME,Rajan DK

    更新日期:2016-10-01 00:00:00

  • Safety and Efficacy of Uterine Artery Embolization in Ectopic Pregnancies Refractory to Systemic Methotrexate Treatment: A Single-Center Study.

    abstract:BACKGROUND:To investigate the use of uterine artery embolization (UAE) to manage ectopic pregnancies that are refractory to systemic methotrexate (MTX) therapy and plagued by persistently high serum β-human chorionic gonadotrophin (hCG) levels and vaginal bleeding. The safety and efficacy of UAE were addressed. MATERI...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-017-1664-7

    authors: Kwon JH,Kim GM,Han K,Kim MD,Won JY,Lee DY

    更新日期:2017-09-01 00:00:00

  • Acute Thrombus Burden on Coated Flow Diverters Assessed by High Frequency Optical Coherence Tomography.

    abstract:PURPOSE:The implantation of flow diverters requires administration of dual anti-platelet therapy, posing the potential for complications. The p48MW HPC (phenox, Bochüm, Germany) hydrophilic-coated flow diverting stent is designed to be anti-thrombotic, thus opening the potential for single anti-platelet therapy. We dep...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-020-02482-w

    authors: King RM,Langan ET,Ughi GJ,Raskett CM,Puri AS,Henkes H,Gounis MJ

    更新日期:2020-08-01 00:00:00

  • Transarterial chemoembolization for hepatocellular carcinoma with drug-eluting microspheres: preliminary results from an Italian multicentre study.

    abstract::The purpose of this article is to present the early results of a multicentre trial using HepaSphere microspheres loaded with chemotherapeutic agents for transarterial chemoembolization (TACE) in patients with unresectable hepatocellular carcinoma. From December 2005 to March 2007, 50 patients (36 male and 14 female, m...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章,多中心研究

    doi:10.1007/s00270-008-9409-2

    authors: Grosso M,Vignali C,Quaretti P,Nicolini A,Melchiorre F,Gallarato G,Bargellini I,Petruzzi P,Massa Saluzzo C,Crespi S,Sarti I

    更新日期:2008-11-01 00:00:00

  • Saline as the sole contrast agent for successful MRI-guided epidural injections.

    abstract:PURPOSE:To assess the performance of sterile saline solution as the sole contrast agent for percutaneous magnetic resonance imaging (MRI)-guided epidural injections at 1.5 T. METHODS:A retrospective analysis of two different techniques of MRI-guided epidural injections was performed with either gadolinium-enhanced sal...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-012-0489-7

    authors: Deli M,Fritz J,Mateiescu S,Busch M,Carrino JA,Becker J,Garmer M,Grönemeyer D

    更新日期:2013-06-01 00:00:00

  • Transcardiac retrograde transvenous embolization of proximally occluded pulmonary arteriovenous malformation.

    abstract:PURPOSE:To report a novel transcardiac retrograde transvenous coil embolization of inadequately proximally occluded pulmonary arteriovenous malformation (AVM). METHODS:Pulmonary AVM in the right A4 segment in an 8-year-old boy with hereditary hemorrhagic telangiectasia was initially treated by proximal occlusion of th...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-013-0755-3

    authors: Komiyama M,Ishiguro T,Umaba R,Suzuki T

    更新日期:2014-06-01 00:00:00

  • Angioplasty after laser perforation.

    abstract::Perforation is the most important complication of laser angioplasty and leads to a decrease in success because the procedure has to be discontinued. In 3 patients we continued despite perforation and were able to stop extravasation with percutaneous transluminal angioplasty (PTA) and to finish the procedure with a goo...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/BF02577707

    authors: Reekers JA,Sprangers RL,van de Kley AJ

    更新日期:1991-03-01 00:00:00

  • Percutaneous drainage of postappendectomy abscesses complicated by enteric communication.

    abstract::Four patients with postappendectomy abscesses complicated by enteric fistulae were treated by percutaneous drainage. Sinograms, obtained at the time of the initial drainage, demonstrated communication to the cecum in 3 patients and to the small bowel in 1 patient. Complete cure was attained in 3 patients by percutaneo...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/BF02577705

    authors: Peer A,Strauss S

    更新日期:1991-03-01 00:00:00

  • Percutaneous angioplasty for atherosclerotic renal artery disease: effect on renal function in azotemic patients.

    abstract:PURPOSE:We studied the effect of percutaneous transluminal renal angioplasty (PTRA) on renal function in azotemic patients with atherosclerotic renal artery stenosis. METHODS:The results of PTRA were analyzed retrospectively in 40 patients. There were 61 stenoses, 54 of which received balloon angioplasty; 7 had stent ...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/BF00195507

    authors: Pattynama PM,Becker GJ,Brown J,Zemel G,Benenati JF,Katzen BT

    更新日期:1994-05-01 00:00:00

  • Percutaneous Intraductal Microwave Ablation and Self-expandable Metallic Stenting: A New Treatment Method for Malignant Extrahepatic Biliary Obstruction.

    abstract:PURPOSE:To evaluate the patency and clinical efficacy of percutaneous intraductal microwave ablation (PIMWA) and uncovered self-expandable metallic stents (USEMs) in inoperable malignant extrahepatic biliary obstruction. MATERIALS AND METHODS:The procedures to be performed on patients with malignant inoperable extrahe...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-020-02684-2

    authors: Pekçevik R,Ballı Ö

    更新日期:2021-01-01 00:00:00

  • Comparison of local control in transcatheter arterial chemoembolization of hepatocellular carcinoma ≤6 cm with or without intraprocedural monitoring of the embolized area using cone-beam computed tomography.

    abstract:PURPOSE:This study was designed to compare technical success and local recurrence rates of transcatheter arterial chemoembolization (TACE) for hepatocellular carcinoma (HCC) with/without monitoring of embolized areas using cone-beam computed tomography (CBCT). METHODS:A total of 207 HCCs ≤6 cm were treated with supers...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-013-0667-2

    authors: Miyayama S,Yamashiro M,Hashimoto M,Hashimoto N,Ikuno M,Okumura K,Yoshida M,Matsui O

    更新日期:2014-04-01 00:00:00

  • Vascular Closure Devices in Interventional Radiology Practice.

    abstract::Manual compression (MC) is a well-established technique for haemostasis following percutaneous arterial intervention. However, MC is labour and time intensive with potential limitations, particularly for patients who are coagulopathic, unable to comply with bed rest or obese and when large sheaths or anti-coagulants a...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00270-015-1116-1

    authors: Patel R,Muller-Hulsbeck S,Morgan R,Uberoi R

    更新日期:2015-08-01 00:00:00

  • Diagnosis and management of Budd Chiari syndrome: an update.

    abstract::Imaging plays a crucial role in the early detection and assessment of the extent of disease in Budd Chiari syndrome (BCS). Early diagnosis and intervention to mitigate hepatic congestion is vital to restoring hepatic function and alleviating portal hypertension. Interventional radiology serves a key role in the manage...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00270-014-0919-9

    authors: Copelan A,Remer EM,Sands M,Nghiem H,Kapoor B

    更新日期:2015-02-01 00:00:00

  • Isolation of the left innominate artery in an elderly patient without congenital heart disease.

    abstract::We report a rare anomaly consisting of a right aortic arch with an isolated left innominate artery in an elderly man without congenital heart disease. ...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s002709910011

    authors: Boren EL Jr,Matchett WJ,Gagne PJ,McFarland DR

    更新日期:2000-01-01 00:00:00

  • Total anomalous pulmonary venous connection to the portal vein.

    abstract::Anomalous pulmonary venous return represents a rare congenital anomaly with wide anatomic and physiologic variability. We report a case of the newborn with a rare form of total infracardiac anomalous pulmonary venous connection (TAPVC). The pulmonary veins draining both lungs formed two vertical veins, which joined to...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/BF02563905

    authors: Wyttenbach M,Carrel T,Schüpbach P,Tschäppeler H,Triller J

    更新日期:1996-03-01 00:00:00

  • Oscillating probe aspiration thrombectomy: comparative in vitro evaluation of two concepts.

    abstract::Aspiration thrombectomy supported by an oscillating metal probe within the catheter allows continuous aspiration of large thrombi without catheter obstruction. Thrombus aspiration assisted by an ultrasound-driven probe (frequency 26 kHz) and by an electric motor-driven probe (frequency 40 Hz) was compared in two diffe...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/BF02735577

    authors: Schmitz-Rode T,Günther RW

    更新日期:1992-05-01 00:00:00

  • Treatment of hepatocellular carcinoma: a single-center experience.

    abstract:PURPOSE:The comparative efficacy of transcatheter arterial chemoembolization (TACE) and percutaneous ethanol injection (PEI) in the treatment of hepatocellular carcinoma (HCC) was investigated. METHODS:Two hundred and sixty consecutive patients were retrospectively analyzed: 156 had received between one and six chemoe...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s002709900104

    authors: Florio F,Nardella M,Balzano S,Caturelli E,Siena D,Cammisa M

    更新日期:1997-01-01 00:00:00

  • Balloon-assisted coil embolization for large-necked renal artery aneurysms.

    abstract::An aneurysm of the right renal artery was discovered in a patient suffering from cerebral arterial angiodysplasia and arterial hypertension. The aneurysm was large necked, which made selective endovascular treatment very difficult. To perform the embolization of the aneurysm, a balloon remodelling technique was used. ...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s002700010049

    authors: Mounayer C,Aymard A,Saint-Maurice JP,Chapot R,Merland JJ,Houdart E

    更新日期:2000-05-01 00:00:00

  • The Randomized Freeway Stent Study: Drug-Eluting Balloons Outperform Standard Balloon Angioplasty for Postdilatation of Nitinol Stents in the SFA and PI Segment.

    abstract:PURPOSE:The prospective randomized multicenter Freeway study evaluated the possible hemodynamic and clinical benefits of primary stent insertion followed by percutaneous transluminal angioplasty (PTA) with drug-eluting balloons (DEB) over post-stent insertion PTA with standard balloons in the treatment of symptomatic f...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章,多中心研究,随机对照试验

    doi:10.1007/s00270-019-02309-3

    authors: Tacke J,Müller-Hülsbeck S,Schröder H,Lammer J,Schürmann K,Gross-Fengels W,Fischbach R,Textor J,Boguth L,Loewe C,Häuser H,Gschwendtner M,Tepe G,von Strandmann RP,Stahnke S,Dambach J,Hausegger K

    更新日期:2019-11-01 00:00:00

  • Deriving the intrahepatic arteriovenous shunt rate from CT images and biochemical data instead of from arterial perfusion scintigraphy in hepatic arterial infusion chemotherapy.

    abstract::The purpose of the present study was to elucidate a method for predicting the intrahepatic arteriovenous shunt rate from computed tomography (CT) images and biochemical data, instead of from arterial perfusion scintigraphy, because adverse exacerbated systemic effects may be induced in cases where a high shunt rate ex...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-009-9603-x

    authors: Ozaki T,Seki H,Shiina M

    更新日期:2009-09-01 00:00:00

  • Multiple fine-needle biopsies using a coaxial technique: efficacy and a comparison of three methods.

    abstract:PURPOSE:Compare the success of three coaxial fine-needle biopsy techniques in obtaining multiple cytologic specimens of high quality. METHODS:For each of three different biopsy needle and technique combinations (aspiration: 22-gauge Chiba; capillary: 22-gauge Chiba; 22-gauge Autovac aspiration biopsy gun), 30 sites (1...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/BF00203681

    authors: Hopper KD,Abendroth CS,TenHave TR,Hartzel J,Savage CA

    更新日期:1995-09-01 00:00:00

  • Long-Term Evaluation of Percutaneous Groin Access for EVAR.

    abstract:BACKGROUND:Percutaneous endovascular aneurysm repair (PEVAR) has been shown to have high success rates, shorter operating times and length of stay compared to open access. However, there exists a lack of long-term follow-up data on these patients, and questions remain regarding longer-term outcomes. This study aims to ...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-018-2072-3

    authors: Dwivedi K,Regi JM,Cleveland TJ,Turner D,Kusuma D,Thomas SM,Goode SD

    更新日期:2019-01-01 00:00:00

  • Selective internal radiation therapy with SIR-spheres for the treatment of unresectable colorectal hepatic metastases.

    abstract::The purpose of this study was to evaluate the effectiveness of colorectal cancer (CRC) liver metastasis radioembolization with yttrium-90 (Y90), assessing toxicity and survival rates in patients with no response to chemotherapy through our 3-year experience. From February 2005 to January 2008, we treated 41 patients a...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-009-9658-8

    authors: Cianni R,Urigo C,Notarianni E,Saltarelli A,Salvatori R,Pasqualini V,Dornbusch T,Cortesi E

    更新日期:2009-11-01 00:00:00

  • Respiratory displacement of the thoracic aorta: physiological phenomenon with potential implications for thoracic endovascular repair.

    abstract::The purpose of this study was to assess the magnitude and direction of respiratory displacement of the ascending and descending thoracic aorta during breathing maneuvers. In 11 healthy nonsmokers, dynamic magnetic resonance imaging was performed in transverse orientation at the tracheal bifurcation during maximum expi...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-009-9553-3

    authors: Weber TF,Tetzlaff R,Rengier F,Geisbüsch P,Kopp-Schneider A,Böckler D,Eichinger M,Kauczor HU,von Tengg-Kobligk H

    更新日期:2009-07-01 00:00:00