Covered metallic stent placement in the treatment of postoperative fistula resistant to conservative management after Billroth I operation.

Abstract:

:A 55-year-old man presented with a case of postoperative enterocutaneous fistula with anastomotic stenosis after a Billroth I operation that was resistant to conservative treatment. This fistula was successfully treated with the placement of a covered metallic stent under fluoroscopic guidance. To our knowledge, this is the first report of postoperative enterocutaneous fistula that was successfully treated with a covered metallic stent.

authors

Kang YJ,Oh JH,Yoon Y,Kim EJ,Ryu KN,Lim JW,Kim DY,Kang HS

doi

10.1007/s00270-004-0103-8

subject

Has Abstract

pub_date

2005-01-01 00:00:00

pages

90-2

issue

1

eissn

0174-1551

issn

1432-086X

journal_volume

28

pub_type

杂志文章
  • Diuretic agent and normal saline infusion technique for ultrasound-guided percutaneous nephrostomies in nondilated pelvicaliceal systems.

    abstract:PURPOSE:Percutaneous nephrostomy (PCN) in a nondilated pelvicaliceal system is technically challenging. We describe an effective method to achieve transient dilatation of the pelvicaliceal system via induction of diuresis using infusion of a diuretic agent in normal saline, therefore allowing easier access to the pelvi...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-012-0461-6

    authors: Yagci C,Ustuner E,Atman ED,Baltaci S,Uzun C,Akyar S

    更新日期:2013-04-01 00:00:00

  • Percutaneous Long Bone Cementoplasty for Palliation of Malignant Lesions of the Limbs: A Systematic Review.

    abstract:PURPOSE:Percutaneous cementoplasty (PC) is rarely applied to long bone tumours, since cement is not considered to be sufficiently resistant to torsional forces. We reviewed the literature to understand the effects of percutaneous long bone cementoplasty (PLBC) in terms of analgesia, limb function and complications. MA...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00270-015-1082-7

    authors: Cazzato RL,Palussière J,Buy X,Denaro V,Santini D,Tonini G,Grasso RF,Zobel BB,Poretti D,Pedicini V,Balzarini L,Lanza E

    更新日期:2015-12-01 00:00:00

  • MR-guided freehand biopsy of liver lesions with fast continuous imaging using a 1.0-T open MRI scanner: experience in 50 patients.

    abstract::The purpose of this study was to assess a new open system with a field-strength of 1.0 T for the feasibility of liver biopsy using the freehand technique with fast continuous imaging. Fifty patients with focal liver lesions measuring 5 to 30 mm in diameter were included in the study. Guidance and monitoring was perfor...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-010-9836-8

    authors: Fischbach F,Bunke J,Thormann M,Gaffke G,Jungnickel K,Smink J,Ricke J

    更新日期:2011-02-01 00:00:00

  • Survival Benefit of Radiofrequency Ablation with Intratumoral Cisplatin Administration in a Rabbit VX2 Lung Tumor Model.

    abstract:PURPOSE:This study evaluated the survival benefit of a combination therapy with radiofrequency ablation (RFA) and intratumoral cisplatin (ITC) administration for lung tumors by using a rabbit VX2 tumor model. MATERIALS AND METHODS:Experiments were approved by the institutional animal care committee. VX2 tumor suspensi...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-020-02686-0

    authors: Murai K,Hamamoto S,Okuma T,Kageyama K,Yamamoto A,Ogawa S,Nota T,Sohgawa E,Jogo A,Miki Y

    更新日期:2020-11-09 00:00:00

  • Inadvertant atrial fixation of a Swan-Ganz catheter by suture and a method for its percutaneous removal.

    abstract::A patient with type I dissection of the thoracic aorta inadvertently had a Swan-Ganz catheter sutured to the right atrium during surgical repair of the dissection. A method for its removal using percutaneous passage of a No. 15 scalpel blade is described. The hazards of Swan-Ganz catheters are explored, and the changi...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/BF02577996

    authors: Wholey MH,Zikria EA,Boyle B

    更新日期:1987-01-01 00:00:00

  • Successful Recanalization of a Complete Lobar Bronchial Stenosis in a Lung Transplant Patient Using a Combined Percutaneous and Bronchoscopic Approach.

    abstract::Airway stenosis is a major complication after lung transplantation that is usually managed with a combination of interventional endoscopic techniques, including endobronchial debridement, balloon dilation, and stent lacement. Herein, we report a successful case of recanalization of a complete stenosis of the right mid...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-015-1219-8

    authors: Miraglia R,Vitulo P,Maruzzelli L,Burgio G,Caruso S,Bertani A,Callari A,Luca A

    更新日期:2016-03-01 00:00:00

  • Long-Term Outcomes of Balloon-Occluded Retrograde Transvenous Obliteration for the Treatment of Gastric Varices: A Comparison of Ethanolamine Oleate and Sodium Tetradecyl Sulfate.

    abstract:PURPOSE:This study was performed to compare the long-term outcomes of balloon-occluded retrograde transvenous obliteration (BRTO) for gastric varices using ethanolamine oleate (EO) and sodium tetradecyl sulfate (STS). METHODS:From January 2002 to June 2015, 142 patients underwent BRTO for the treatment of gastric vari...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-017-1869-9

    authors: Chu HH,Kim M,Kim HC,Lee JH,Jae HJ,Chung JW

    更新日期:2018-04-01 00:00:00

  • Endovascular repair of a ruptured mycotic aneurysm of the common iliac artery.

    abstract::This report describes the case of a ruptured mycotic aneurysm of the left common iliac artery, successfully treated with endovascular stent-grafting. A 64-year-old woman underwent diagnostic coronary angiography complicated by an infected hematoma of the left groin. Seven days later, she developed methicillin-resistan...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-007-9025-6

    authors: Mofidi R,Bhat R,Nagy J,Griffiths GD,Chakraverty S,East of Scotland Vascular Network.

    更新日期:2007-09-01 00:00:00

  • Percutaneous removal of a biliary stent after acute spontaneous duodenal perforation.

    abstract::A 38-year-old woman was treated for malignant stricture by the endoscopic placement of a biliary endoprosthesis. She developed a large retroperitoneal biloma secondary to acute duodenal perforation by the stent. We describe the successful percutaneous retrieval of the biliary stent through a retroperitoneal approach w...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/BF00204152

    authors: Bui BT,Oliva VL,Ghattas G,Daloze P,Bourdon F,Carignan L

    更新日期:1995-05-01 00:00:00

  • Adrenal radiofrequency ablation in swine: change in blood pressure and histopathologic analysis.

    abstract:PURPOSE:To evaluate changes in blood pressure during adrenal radiofrequency ablation (RFA) and analyze histopathologic outcomes in swine adrenal glands. MATERIALS AND METHODS:Animal Care Committee approval was obtained for this study. After laparotomy, a single adrenal gland was ablated from each of six animals (six R...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-010-0078-6

    authors: Yamakado K,Takaki H,Uchida K,Nakatsuka A,Shiraishi T,Takeda K

    更新日期:2011-08-01 00:00:00

  • Catheter-malposition-induced cardiac tamponade via contrast media leakage during computed tomography study.

    abstract::We present a rare case of a central venous catheter-malposition-induced life-threatening cardiac tamponade as a result of computed tomography (CT) with contrast enhancement in an infant with a ventricular septal defect and pulmonary atresia after a modified Blalock-Taussig shunt. The diagnosis was confirmed by chest r...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-004-0340-x

    authors: Liang CD,Ko SF,Huang CF,Chien SJ,Tiao MM

    更新日期:2005-11-01 00:00:00

  • CT guided bone biopsy using a battery powered intraosseous device.

    abstract:PURPOSE:To evaluate the feasibility of a battery powered intraosseous device to perform CT-fluoroscopy guided bone biopsy. METHODS:Retrospective analysis of 12 patients in whom bone specimen were acquired from different locations under CT-fluoroscopy guidance using the OnControl bone marrow biopsy system (OBM, Vidacar...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-013-0617-z

    authors: Schnapauff D,Marnitz T,Freyhardt P,Collettini F,Hartwig K,Jöhrens K,Hamm B,Kroencke T,Gebauer B

    更新日期:2013-10-01 00:00:00

  • Adrenal Vein Sampling for Primary Aldosteronism: A 2-Week Protocol for Withdrawal of Renin-Stimulating Antihypertensives.

    abstract:OBJECTIVE:For evaluation of primary aldosteronism, international guidelines recommend a 4-6 week withdrawal of spironolactone, eplerenone, and amiloride prior to adrenal vein sampling (AVS). It is not always feasible to withdraw these drugs in patients with severe hypertension and hypokalemia. We present our experience...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-017-1637-x

    authors: Ching KC,Cohen DL,Fraker DL,Trerotola SO

    更新日期:2017-09-01 00:00:00

  • Mortality and Rates of Secondary Intervention After EVAR in an Unselected Population: Influence of Simple Clinical Categories and Implications for Surveillance.

    abstract:INTRODUCTION:Post-EVAR surveillance has a major impact upon patients, carers and healthcare resources. We hypothesised that elective indication, on-IFU anatomy, use of a modern device or normal first CTA, or a combination of these categories, might predict a rate of secondary intervention low enough to alter current su...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-016-1303-8

    authors: Hammond CJ,Shah AH,Snoddon A,Patel JV,Scott DJ

    更新日期:2016-06-01 00:00:00

  • Comparison of pain after uterine artery embolization using tris-acryl gelatin microspheres versus polyvinyl alcohol particles.

    abstract::When compared in a uterine artery embolization (UAE) animal model, Embospheres (ES) (Biosphere Medical, Rockland, MA) were found to induce less uterine ischemia than polyvinyl alcohol (PVA) particles. Given this finding, we aimed to test the hypothesis that ES is associated with less pain after UAE than PVA in human p...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-003-0045-6

    authors: Ryu RK,Omary RA,Sichlau MJ,Siddiqi A,Chrisman HB,Nemcek AA Jr,Vogelzang RL

    更新日期:2003-07-01 00:00:00

  • Ureteric embolization for lower urinary tract fistulae: use of two amplatzer vascular plugs and N-butyl cyanoacrylate employing the "sandwich" technique.

    abstract:PURPOSE:This study describes and evaluated the effectiveness of occluding distal ureters in the clinical setting of urinary vaginal (vesicovaginal or enterovesicovaginal) fistulae utilizing a new technique which combines Amplatzer vascular plugs and N-butyl cyanoacrylate. MATERIALS:This is a retrospective study (Janua...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-012-0510-1

    authors: Saad WE,Kalagher S,Turba UC,Sabri SS,Park AW,Stone J,Angle JF,Matsumoto AH

    更新日期:2013-08-01 00:00:00

  • Instrumentation for magnetic resonance angiography.

    abstract::Magnetic resonance angiography (MRA) places high demands on instrumentation capabilities. Magnetic gradient strength capabilities, main magnetic field strength and homogeneity, and eddy current compensation all play a role in determining the quality of the flow studies. In addition, radiofrequency coil design and use ...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/BF02733895

    authors: Saloner D,Anderson CM

    更新日期:1992-01-01 00:00:00

  • Thoracic Duct Embolization in Post-neck Dissection Chylous Leakage: A Case Series of Six Patients and Review of the Literature.

    abstract::Chylous leak is a serious complication of neck dissection. Patients are often managed conservatively, and failure of conservative management necessitates surgical management, which adds to their morbidity. We present a case series demonstrating the value of thoracic duct embolization (TDE) in management of patients wi...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00270-020-02475-9

    authors: Moussa AM,Maybody M,Gonzalez-Aguirre AJ,Buicko JL,Shaha AR,Santos E

    更新日期:2020-06-01 00:00:00

  • Multiple fine-needle biopsies using a coaxial technique: efficacy and a comparison of three methods.

    abstract:PURPOSE:Compare the success of three coaxial fine-needle biopsy techniques in obtaining multiple cytologic specimens of high quality. METHODS:For each of three different biopsy needle and technique combinations (aspiration: 22-gauge Chiba; capillary: 22-gauge Chiba; 22-gauge Autovac aspiration biopsy gun), 30 sites (1...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/BF00203681

    authors: Hopper KD,Abendroth CS,TenHave TR,Hartzel J,Savage CA

    更新日期:1995-09-01 00:00:00

  • Looking for the ideal particle: an experimental embolization study.

    abstract::This study sought to compare the most frequently used embolic particles in an animal model. In 16 New Zealand white rabbits, right renal arteries were embolized using four different embolic particles (polyvinyl alcohol [PVA] particles, 150-250 microm; PVA microspheres [PVAMs], 150-300 microm; Tris-acryl gelatin micros...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-009-9747-8

    authors: Senturk C,Cakir V,Yorukoglu K,Yilmaz O,Goktay AY

    更新日期:2010-04-01 00:00:00

  • Direct primary or secondary percutaneous ureteral stenting: what is the most compliant option in patients with malignant ureteral obstructions?

    abstract::The objective of this study was to analyze three ureteral stenting techniques in patients with malignant ureteral obstructions, considering the indications, techniques, procedural costs, and complications. In the period between June 2003 and June 2006, 45 patients with bilateral malignant ureteral obstructions were ev...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-007-9016-7

    authors: Carrafiello G,Laganà D,Lumia D,Giorgianni A,Mangini M,Santoro D,Cuffari S,Marconi A,Novario R,Fugazzola C

    更新日期:2007-09-01 00:00:00

  • Uterine artery embolisation for symptomatic adenomyosis with polyzene F-coated hydrogel microspheres: three-year clinical follow-up using UFS-QoL questionnaire.

    abstract:PURPOSE:This study was designed to assess midterm outcome of uterine artery embolisation (UAE) for women with therapy-resistant adenomyosis using polyzene F-coated hydrogel microspheres. METHODS:Between September 2006 and January 2010, 29 consecutive women with adenomyosis (15 in combination with fibroids) were treate...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-014-0878-1

    authors: Nijenhuis RJ,Smeets AJ,Morpurgo M,Boekkooi PF,Reuwer PJ,Smink M,van Rooij WJ,Lohle PN

    更新日期:2015-02-01 00:00:00

  • Mechanical thrombectomy in inferior vena cava thrombosis after caval filter placement: a report of three cases.

    abstract::Inferior vena caval (IVC) filter thrombosis in patients with contraindications to anticoagulant therapy is a difficult and challenging clinical problem. We report our experience in treating three such patients using a mechanical thrombectomy device, which resulted in rapid symptomatic relief until anticoagulant therap...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-002-1921-1

    authors: Poon WL,Luk SH,Yam KY,Lee AC

    更新日期:2002-09-01 00:00:00

  • Acute coronary artery air embolism following CT-guided lung biopsy.

    abstract::CT-guided needle biopsy is a common procedure for obtaining a tissue diagnosis and consequently correctly managing patients. This procedure has many potential complications, ranging from simple pneumothorax or self-limiting hemoptysis to life-threatening pulmonary hemorrhage and air embolism. Though the latter is a ra...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-004-0118-1

    authors: Mansour A,AbdelRaouf S,Qandeel M,Swaidan M

    更新日期:2005-01-01 00:00:00

  • Management of renal tumors by image-guided radiofrequency ablation: experience in 105 tumors.

    abstract:AIMS:In this article we present our experience with radiofrequency ablation (RFA) in the treatment of 105 renal tumors. MATERIALS AND METHODS:RFA was performed on 105 renal tumors in 97 patients, with a mean tumor size of 32 mm (11-68 mm). The mean patient age was 71.7 years (range, 36-89 years). The ablations were ca...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-007-9090-x

    authors: Breen DJ,Rutherford EE,Stedman B,Roy-Choudhury SH,Cast JE,Hayes MC,Smart CJ

    更新日期:2007-09-01 00:00:00

  • Successful Portal Vein Stent Placement in a Child with Cavernomatous Replacement of the Portal Vein After Partial Liver Transplantation: The Importance of a Recognizable Portal Vein Remnant.

    abstract::Late portal vein thrombosis with cavernomatous replacement has been reported in 4.5% of pediatric patients who have undergone partial liver transplantation. In such cases, minimally invasive radiological treatments have a high failure rate. We report a successful case of percutaneous recanalization of the portal vein ...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-015-1084-5

    authors: Miraglia R,Maruzzelli L,Caruso S,Ricotta C,Riva S,Burgio G,Spada M,Luca A

    更新日期:2015-12-01 00:00:00

  • Endovascular aortic repair with the chimney technique using the ultra low-profile Ovation stent-graft for juxtarenal aneurysms having small iliac access vessels.

    abstract:PURPOSE:To report the first experience using the chimney technique in combination with the latest-generation low-profile stent-graft to seal abdominal aortic aneurysms having a very short neck (proximal sealing zone) and difficult access due to very small iliac vessels. MATERIALS AND METHODS:Use of an ultra low-profil...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-013-0748-2

    authors: Massmann A,Serracino-Inglott F,Buecker A

    更新日期:2014-04-01 00:00:00

  • Long-term safety and effectiveness of the "OptEase" vena cava filter.

    abstract:PURPOSE:To assess the long-term safety and effectiveness of the OptEase inferior vena cava (IVC) filter. MATERIALS AND METHODS:In this Institutional Review Board-approved, retrospective study, we reviewed data of 71 patients who received an OptEase filter at our institution from 2002 to 2007. Thirty-nine (55%) patient...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-010-9969-9

    authors: Kalva SP,Marentis TC,Yeddula K,Somarouthu B,Wicky S,Stecker MS

    更新日期:2011-04-01 00:00:00

  • CIRSE Standards of Practice on Analgesia and Sedation for Interventional Radiology in Adults.

    abstract::This CIRSE Standards of Practice document provides best practices for the safe administration of procedural sedation and analgesia for interventional radiology procedures in adults. The document is aimed at health professionals involved in the provision of sedation and analgesia during interventional radiology procedu...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-020-02536-z

    authors: Romagnoli S,Fanelli F,Barbani F,Uberoi R,Esteban E,Lee MJ,Nielsen PT,Mahnken AH,Morgan R

    更新日期:2020-09-01 00:00:00

  • An assessment of radiologically inserted transoral and transgastric gastroduodenal stents to treat malignant gastric outlet obstruction.

    abstract:INTRODUCTION:Self-expanding metallic stents (SEMS) are used to palliate malignant gastric outlet obstruction (GOO) and are useful in patients with limited life expectancy or severe medical comorbidity, which would preclude surgery. Stenting can be performed transorally or by a percutaneous transgastric technique. Our g...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-013-0584-4

    authors: Miller BHT,Griffiths EA,Pursnani KG,Ward JB,Stockwell RC

    更新日期:2013-12-01 00:00:00