Capsular peeling in anterior capsule contraction syndrome: surgical approach and histopathological aspects.

Abstract:

:We present 4 cases of anterior capsule contraction syndrome in which progressive shrinkage of the anterior capsulorhexis developed after uneventful phacoemulsification. Three eyes were pseudophakic, and 1 eye remained aphakic. The newly formed membrane was surgically peeled from the anterior capsule, restoring the capsular bag.

authors

Reyntjens B,Tassignon MJ,Van Marck E

doi

10.1016/j.jcrs.2003.08.034

subject

Has Abstract

pub_date

2004-04-01 00:00:00

pages

908-12

issue

4

eissn

0886-3350

issn

1873-4502

pii

S0886335003009386

journal_volume

30

pub_type

杂志文章
  • Carbon dioxide laser use in wound sealing and epikeratophakia.

    abstract::This paper presents current clinical and experimental uses of the carbon dioxide laser and the results of our human and animal tissue fusion investigations. Trials were conducted with human scleral and corneal eye bank tissue and in albino rabbits. With power settings of 100 to 200 mW, optimal laser effect consisting ...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(87)80073-1

    authors: Keates RH,Levy SN,Fried S,Morris JR

    更新日期:1987-05-01 00:00:00

  • Nanophthalmos: ultrasound biomicroscopy and Pentacam assessment of angle structures before and after cataract surgery.

    abstract::We report a case of nanophthalmos with intractable secondary glaucoma. Bilateral cataract extraction with intraocular lens implantation was used as definitive treatment for the chronic angle-closure glaucoma. The changes in angle and ciliary body anatomy were well documented with preoperative and postoperative Pentaca...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2006.02.051

    authors: Sharan S,Grigg JR,Higgins RA

    更新日期:2006-06-01 00:00:00

  • Keratometry versus total corneal refractive power: Analysis of measurement repeatability with 5 different devices in normal eyes with low astigmatism.

    abstract:PURPOSE:To analyze the repeatability of corneal astigmatism measurements with 2 autokeratometers (IOLMaster 500 and Lenstar LS 900), 2 Placido topographers (Keratron Scout and Atlas 9000), and a Scheimpflug tomographer (Pentacam HR). SETTING:Department of Ophthalmology, Goethe University, Frankfurt, Germany. DESIGN:P...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2015.11.046

    authors: Fityo S,Bühren J,Shajari M,Kohnen T

    更新日期:2016-04-01 00:00:00

  • One or 2 Intacs segments for the correction of keratoconus.

    abstract:PURPOSE:To evaluate the effect of implanting 1 or 2 intracorneal rings (Intacs, KeraVision) as a device to correct, stabilize, and/or improve the best corrected visual acuity in patients with clear cornea keratoconus oriented by the preoperative corneal topography pattern. SETTING:Vissum/Instituto Oftalmológico de Ali...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2004.09.050

    authors: Alió JL,Artola A,Hassanein A,Haroun H,Galal A

    更新日期:2005-05-01 00:00:00

  • Anterior-assisted levitation for the posteriorly dislocated intraocular lens.

    abstract::I describe a technique to manage a subluxated crystalline lens or an in-the-bag posterior chamber intraocular lens (PC IOL) that tilts severely into the anterior or midvitreous cavity. In the absence of intervening vitreous presentation, a 27-gauge needle is inserted via a snugly fitting paracentesis incision to reach...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2009.01.030

    authors: Chee SP

    更新日期:2009-06-01 00:00:00

  • Simple method for accurate alignment in toric phakic and aphakic intraocular lens implantation.

    abstract::A simple technique for the accurate surgical alignment of toric phakic and aphakic intraocular lenses (IOLs) is described. The mathematical relationship between toric misalignment and cylinder error is reviewed to demonstrate the importance of toric lens alignment in the setting of increased rotational stability with ...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2008.04.041

    authors: Ma JJ,Tseng SS

    更新日期:2008-10-01 00:00:00

  • Efficacy of the soft-shell technique using Viscoat and Hyal-2000.

    abstract:PURPOSE:To evaluate whether the soft-shell technique using Viscoat (sodium hyaluronate 3%-chondroitin sulfate 4%) and Hyal-2000 (sodium hyaluronate 1%) reduces corneal endothelial cell damage during cataract surgery. SETTING:Department of Ophthalmology, Kangnam St. Mary's Hospital, Seoul, Korea. METHODS:The nuclear o...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2004.02.089

    authors: Kim H,Joo CK

    更新日期:2004-11-01 00:00:00

  • Comparison of 2 techniques of intraocular lens implantation in pediatric cataract surgery.

    abstract:PURPOSE:To compare the results of 2 intraocular lens (IOL) implantation techniques in pediatric cataract surgery. SETTING:Labbafinejad Medical Center, Tehran, Iran. METHODS:This contralateral prospective randomized study comprised children with bilateral congenital or developmental cataract. In all cases, anterior ca...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章,随机对照试验

    doi:10.1016/j.jcrs.2009.02.017

    authors: Faramarzi A,Javadi MA

    更新日期:2009-06-01 00:00:00

  • Effects on visual function of glistenings and folding marks in AcrySof intraocular lenses.

    abstract:PURPOSE:To study the effects on visual function of glistenings and folding marks in AcrySof (Alcon) intraocular lenses (IOLs). SETTING:Department of Ophthalmology, Dokuz Eylül University, School of Medicine, Izmir, Turkey. METHODS:This study included 91 eyes that had phacoemulsification and in-the-bag AcrySof IOL imp...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(01)00995-6

    authors: Gunenc U,Oner FH,Tongal S,Ferliel M

    更新日期:2001-10-01 00:00:00

  • Femtosecond laser versus mechanical microkeratome laser in situ keratomileusis for myopia: Metaanalysis of randomized controlled trials.

    abstract:PURPOSE:To examine differences in efficacy, accuracy, safety, and changes in aberrations between femtosecond and mechanical microkeratome laser in situ keratomileusis (LASIK) for myopia. SETTING:Department of Ophthalmology, Shanghai First People's Hospital Affiliated to Shanghai Jiaotong University, Shanghai, China. ...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章,meta分析

    doi:10.1016/j.jcrs.2011.05.043

    authors: Zhang ZH,Jin HY,Suo Y,Patel SV,Montés-Micó R,Manche EE,Xu X

    更新日期:2011-12-01 00:00:00

  • Clinical performance of a handheld digital infrared monocular pupillometer for measurement of the dark-adapted pupil diameter.

    abstract:PURPOSE:To compare the accuracy of a handheld infrared digital pupillometer and digital infrared photography for measurement of the dark-adapted pupil diameter. SETTING:Department of Ophthalmology and Visual Sciences, Texas Tech University Health Sciences Center, Lubbock, Texas, USA. METHODS:The right horizontal pupi...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2009.09.025

    authors: Bradley JC,Bentley KC,Mughal AI,Brown SM

    更新日期:2010-02-01 00:00:00

  • Cataract in pseudohypoparathyroidism.

    abstract:UNLABELLED:A 22-year-old white man presented with photopsia of 3-year duration despite a corrected distance visual acuity of 20/20 in both eyes. Ophthalmic examination revealed multiple irregularly shaped white cortical opacifications of the lens in both eyes but no other significant ocular findings. One year after the...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2016.06.007

    authors: Grajewski RS,Koch KR,Koch HR,Ciotu IM,Cursiefen C,Heindl LM

    更新日期:2016-07-01 00:00:00

  • Changes in pupil size induced by phacoemulsification and posterior chamber lens implantation: consequences for multifocal lenses.

    abstract:PURPOSE:Because the optical performance of eyes implanted with multifocal intraocular lenses will theoretically depend upon the size and position of the pupil relative to the near and distance zones of the lens, we designed a study to determine whether preoperative pupil size is useful in predicting the postoperative p...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(96)80013-7

    authors: Koch DD,Samuelson SW,Villarreal R,Haft EA,Kohnen T

    更新日期:1996-06-01 00:00:00

  • Effect of preoperative tear function on early functional visual acuity after laser in situ keratomileusis.

    abstract:PURPOSE:To assess the effect of preoperative tear function on early changes in functional visual acuity (FVA) after laser in situ keratomileusis (LASIK). SETTING:Minamiaoyama Eye Clinic, Tokyo, Japan. METHODS:This prospective single-center study assessed the effect of preoperative and postoperative tear functions on ...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2004.02.086

    authors: Tanaka M,Takano Y,Dogru M,Toda I,Asano-Kato N,Komai-Hori Y,Tsubota K

    更新日期:2004-11-01 00:00:00

  • Noncicatricial oval deformation of the pupil induced by sulcus-fixated one-piece posterior chamber lenses.

    abstract::A retrospective analysis of 40 cases of sulcus-fixated one-piece poly(methyl methacrylate) posterior chamber lenses revealed ten cases (25%) that demonstrated oval deformation of the pupil, similar to the condition associated with anterior chamber lenses. This complication was not noted until several weeks after surge...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(13)80803-6

    authors: Masket S

    更新日期:1990-07-01 00:00:00

  • Unilateral corneal ectasia following small-incision lenticule extraction.

    abstract:UNLABELLED:We describe a case of unilateral corneal ectasia in a 26-year-old man following small-incision lenticule extraction. The preoperative corneal topography was normal, with a minimum corneal thickness of 511 μm and 513 μm in the right eye and left eye, respectively. Lenticules of 85 μm and 82 μm were fashioned ...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2015.08.006

    authors: Sachdev G,Sachdev MS,Sachdev R,Gupta H

    更新日期:2015-09-01 00:00:00

  • New surgical approach in cases of cataract with ocular Stevens-Johnson syndrome.

    abstract::We describe the intraoperative difficulties encountered in cases of ocular Stevens-Johnson syndrome as a result of a poor ocular surface, the presence of symblepharon, and varying degrees of corneal opacity with secondary poor visibility of anterior segment structures. Modifications to the standard phacoemulsification...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2016.09.012

    authors: Sharma N,Aron N,Venugopal R,Sangwan S,Titiyal JS,Agarwal T

    更新日期:2016-11-01 00:00:00

  • Subjective photic phenomena with refractive multifocal and monofocal intraocular lenses. results of a multicenter questionnaire.

    abstract:PURPOSE:To compare the incidence and severity of photic phenomena after the implantation of the Array(R) (Allergan) refractive multifocal intraocular lens (MIOL) and a monofocal IOL. SETTING:Multicenter study at Kiel, Mainz, Karlsruhe, and Bremerhaven, Germany. METHODS:The study comprised 231 randomly selected patien...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 临床试验,杂志文章,多中心研究,随机对照试验

    doi:10.1016/s0886-3350(00)00540-x

    authors: Häring G,Dick HB,Krummenauer F,Weissmantel U,Kröncke W

    更新日期:2001-02-01 00:00:00

  • Possible protection of the posterior segment by a phakic intraocular lens.

    abstract::A 39-year-old man was referred with complaints of pain, redness, and reduced vision in the left eye after projectile trauma during hammering. Two years previously, anterior chamber phakic intraocular lenses (pIOLs) had been implanted to correct the patient's high myopia. On presentation, the best corrected visual acui...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2007.07.022

    authors: Feizi S,Jadidi K,Soheilian M

    更新日期:2007-12-01 00:00:00

  • Clinical analysis of the factors contributing to pupillary optic capture after transscleral fixation of posterior chamber intraocular lens for dislocated intraocular lens.

    abstract:PURPOSE:To study the incidence of and risk factors for pupillary capture after transscleral fixation of a posterior chamber intraocular lens (PC IOL) for dislocated IOLs. SETTING:Department of Ophthalmology, Kyungpook National University Hospital, Daegu, South Korea. DESIGN:Retrospective case series. METHODS:Charts ...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2016.05.006

    authors: Kang DJ,Kim HK

    更新日期:2016-08-01 00:00:00

  • Two opacification patterns of the same hydrophilic acrylic polymer: case reports and clinicopathological correlation.

    abstract::We report 2 intraocular lenses (IOLs) manufactured from the same hydrophilic acrylic polymer by Ioltech that developed optic opacification. In both cases, the postoperative course after implantation of the IOLs was complicated by significant inflammatory reaction with fibrin formation in the anterior chamber. Patholog...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2006.01.076

    authors: Neuhann IM,Stodulka P,Werner L,Mamalis N,Pandey SK,Kleinmann G,Apple DJ

    更新日期:2006-05-01 00:00:00

  • Adjusting intraocular lens power for sulcus fixation.

    abstract:PURPOSE:To determine the appropriate correction of predicted intraocular lens (IOL) power for sulcus fixation and to prospectively assess the validity of the obtained correction value in patients having sulcus fixation. SETTING:Department of Ophthalmology, Saiseikai Kurihashi Hospital, Saitama, Japan. METHODS:The pos...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(03)00250-5

    authors: Suto C,Hori S,Fukuyama E,Akura J

    更新日期:2003-10-01 00:00:00

  • Traumatic expulsive iridodialysis after small-incision sutureless cataract surgery.

    abstract::Phacoemulsification with intraocular lens (IOL) implantation was performed in the right eye of an 84-year-old woman using a small clear corneal incision. Ten weeks after surgery, the patient fell, which caused traumatic iridodialysis and hyphema with expulsion of the iris through the surgical corneal incision. Apart f...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2004.03.040

    authors: Walker NJ,Foster A,Apel AJ

    更新日期:2004-10-01 00:00:00

  • Validation of a handheld automated keratometer in adults.

    abstract:PURPOSE:To evaluate the Nidek handheld automated keratometer and compare it with the manual Zeiss keratometer. SETTING:St. Paul's Eye Unit, Royal Liverpool University Hospital, Liverpool, United Kingdom. METHODS:Forty-five normal adult volunteers were included in the study. Three sets of randomized keratometry measur...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1016/s0886-3350(98)80333-7

    authors: Noonan CP,Rao GP,Kaye SB,Green JR,Chandna A

    更新日期:1998-03-01 00:00:00

  • Laser in situ keratomileusis for consecutive hyperopia after myopic LASIK and radial keratotomy.

    abstract:PURPOSE:To evaluate and compare the efficacy, predictability, and safety of hyperopic laser in situ keratomileusis (H-LASIK) for the correction of consecutive hyperopia after myopic-LASIK (M-LASIK) and radial keratotomy (RK). SETTING:The Eye Institute of Utah, Salt Lake City, Utah, USA. METHODS:Seventy-seven eyes of ...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(03)00051-8

    authors: Lyle WA,Jin GJ

    更新日期:2003-05-01 00:00:00

  • Correcting simple myopic astigmatism with the excimer laser.

    abstract::For one year we followed 46 eyes that had photoastigmatic refractive keratectomy with an excimer laser to correct simple myopic astigmatism. Mean preoperative cylinder was -2.50 +/- 0.70 diopters (D); mean preoperative best corrected visual acuity was 20/25 +/- 1 Snellen line. Mean postoperative refraction one year af...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(13)80207-6

    authors: Alió JL,Artola A,Ayala MJ,Claramonte P

    更新日期:1995-09-01 00:00:00

  • Stromal haze after laser in situ keratomileusis: clinical and confocal microscopy findings.

    abstract:PURPOSE:To report clinical and confocal microscopy characteristics of haze-like opacities in corneas after laser in situ keratomileusis (LASIK). SETTING:Department of Ophthalmology, Johann Wolfgang Goethe-University, Frankfurt am Main, Germany. METHODS:Eighteen eyes of 11 patients with clinically apparent corneal clo...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(02)02050-3

    authors: Bühren J,Kohnen T

    更新日期:2003-09-01 00:00:00

  • Induction of apoptosis of rabbit corneal endothelial cells by preservative-free lidocaine hydrochloride 2%, ropivacaine 1%, or levobupivacaine 0.75%.

    abstract:PURPOSE:To determine and compare the amount of apoptosis and changes in rabbit corneal endothelial cell morphology after intracameral administration of different anesthetic agents. SETTING:Department of Ophthalmology, Baskent University Medical Faculty, Ankara, Turkey. METHODS:Right eyes of 64 Vienna white rabbits we...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2008.12.016

    authors: Borazan M,Karalezli A,Oto S,Akova YA,Karabay G,Kocbiyik A,Celasun B,Demirhan B

    更新日期:2009-04-01 00:00:00

  • Mature cataracts in eyes with unilateral axial myopia.

    abstract::Seven patients with unsuspected unilateral axial myopia developed a cataract in the longer eye. Vision deteriorated in all cases between the ages of 40 and 55 years. Bilateral axial length measurements were necessary for the diagnosis and revealed a difference of 4.5 mm to 6.7 mm between the two eyes. Five cases had a...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(89)80090-2

    authors: Shammas HJ,Milkie CF

    更新日期:1989-05-01 00:00:00

  • Scheimpflug measurement of intraocular lens position after piggyback implantation of foldable intraocular lenses in eyes with high hyperopia.

    abstract:PURPOSE:To investigate the position of 3-piece foldable intraocular lenses (IOLs) after piggyback implantation for high hyperopia. SETTING:University Eye Hospital, Johann Wolfgang Goethe University, Frankfurt am Main, Germany. METHODS:Eight eyes of 5 highly hyperopic patients had phacoemulsification and implantation ...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2006.08.033

    authors: Baumeister M,Kohnen T

    更新日期:2006-12-01 00:00:00