Adjusting intraocular lens power for sulcus fixation.

Abstract:

PURPOSE:To determine the appropriate correction of predicted intraocular lens (IOL) power for sulcus fixation and to prospectively assess the validity of the obtained correction value in patients having sulcus fixation. SETTING:Department of Ophthalmology, Saiseikai Kurihashi Hospital, Saitama, Japan. METHODS:The postoperative refraction, virtual in-the-bag IOL power for the same postoperative refraction, predicted refraction with an increase in in-the-bag IOL power by 0.50 to 2.00 diopters (D), and effective lens position (ELP) in 30 eyes with a normal axial length after sulcus fixation were retrospectively evaluated. The results were confirmed prospectively in 16 other eyes requiring sulcus fixation. RESULTS:A significant myopic shift (mean 0.78 D +/- 0.47 [SD]) from the predicted refraction occurred after sulcus fixation (P<.0001). The mean virtual IOL power was 1.11 +/- 0.67 D higher than that of the actual sulcus-fixated IOL. The difference between the predicted refraction and the refraction after sulcus fixation was less when the difference in IOL power was 1.00 D. The ELP of the IOLs was 0.75 mm shorter using A-mode measurement and 0.62 mm shorter using back calculation from the theoretical formula with sulcus fixation than with in-the-bag fixation. In the prospective study, there was a small refractive error (mean -0.06 +/- 0.19 D) when the planned IOL power was reduced by 1.00 D for sulcus fixation. CONCLUSION:For sulcus fixation in eyes with a normal axial length, the IOL power should be 1.00 D less than the power for in-the-bag fixation.

authors

Suto C,Hori S,Fukuyama E,Akura J

doi

10.1016/s0886-3350(03)00250-5

subject

Has Abstract

pub_date

2003-10-01 00:00:00

pages

1913-7

issue

10

eissn

0886-3350

issn

1873-4502

pii

S0886335003002505

journal_volume

29

pub_type

杂志文章
  • Anaphylactic reaction following intracameral cefuroxime injection during cataract surgery.

    abstract::We report a patient who developed an anaphylactic reaction several minutes after intracameral injection of cefuroxime at the end of uneventful phacoemulsification and intraocular lens implantation surgery. The patient had a known allergy to penicillin but not to cefuroxime. This rare life-threatening complication was ...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2013.06.008

    authors: Moisseiev E,Levinger E

    更新日期:2013-09-01 00:00:00

  • Two opacification patterns of the same hydrophilic acrylic polymer: case reports and clinicopathological correlation.

    abstract::We report 2 intraocular lenses (IOLs) manufactured from the same hydrophilic acrylic polymer by Ioltech that developed optic opacification. In both cases, the postoperative course after implantation of the IOLs was complicated by significant inflammatory reaction with fibrin formation in the anterior chamber. Patholog...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2006.01.076

    authors: Neuhann IM,Stodulka P,Werner L,Mamalis N,Pandey SK,Kleinmann G,Apple DJ

    更新日期:2006-05-01 00:00:00

  • Outcomes of cataract surgery and intraocular lens implantation with and without intracameral triamcinolone in pediatric eyes.

    abstract:PURPOSE:To evaluate whether intracameral triamcinolone has an effect on anterior segment inflammation and visual axis obscuration after pediatric cataract surgery with intraocular (IOL) implantation. SETTING:Iladevi Cataract and IOL Research Institute, Ahmedabad, India. METHODS:This retrospective age-matched case-con...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2010.03.040

    authors: Dixit NV,Shah SK,Vasavada V,Vasavada VA,Praveen MR,Vasavada AR,Trivedi RH

    更新日期:2010-09-01 00:00:00

  • Pharmacotherapy of photorefractive keratectomy.

    abstract:PURPOSE:To compare the pharmacotherapeutic practices of high-volume photorefractive keratectomy (PRK) surgeons with suggested practices gleaned from the current literature. SETTING:York Finch Eye Associates, Toronto, Canada. METHODS:Seventy-five ophthalmic surgeons believed by the authors to do a high-volume of PRKs ...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1016/s0886-3350(96)80116-7

    authors: Arshinoff SA,Mills MD,Haber S

    更新日期:1996-10-01 00:00:00

  • Posterior chamber toric phakic intraocular lens implantation for high myopic astigmatism in eyes with pellucid marginal degeneration.

    abstract:UNLABELLED:We report a case in which toric intraocular Collamer lenses (ICLs) effectively corrected the refractive errors of pellucid marginal degeneration (PMD). Preoperatively, in the patient's right eye, the manifest refraction was -10.5 -3.5 x 55, the uncorrected distance visual acuity (UDVA) was 20/1000, and the c...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2009.08.021

    authors: Kamiya K,Shimizu K,Hikita F,Komatsu M

    更新日期:2010-01-01 00:00:00

  • Effect of preoperative pupil measurements on glare, halos, and visual function after photoastigmatic refractive keratectomy.

    abstract:PURPOSE:To prospectively assess the effect of preoperative variables such as pupil size on glare, halos, and visual function after photoastigmatic refractive keratectomy (PARK). SETTING:Department of Ophthalmology, Stanford University School of Medicine, Stanford, California, USA. METHODS:Ninety-three eyes had PARK f...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(01)00871-9

    authors: Haw WW,Manche EE

    更新日期:2001-06-01 00:00:00

  • Quality of images with toric intraocular lenses.

    abstract:PURPOSE:To objectively evaluate the image quality obtained with toric intraocular lenses (IOLs) when misaligned from the intended axis. SETTING:University Eye Clinic and the Department of Industrial and Information Engineering, University of Trieste, Trieste, Italy. DESIGN:Experimental study. METHODS:An experimental...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2017.10.053

    authors: Tognetto D,Perrotta AA,Bauci F,Rinaldi S,Antonuccio M,Pellegrino FA,Fenu G,Stamatelatos G,Alpins N

    更新日期:2018-03-01 00:00:00

  • Cyclooxygenase-2 inhibitors: a new therapeutic option in the treatment of macular edema after cataract surgery.

    abstract::Two patients had uneventful phacoemulsification. After initial improvement, vision deteriorated because of cystoid macular edema (CME). In 1 patient, treatment with systemic nonsteroidal antiinflammatory drugs showed significant improvement in visual acuity but had to be discontinued because of side effects and a rela...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2004.12.067

    authors: Reis A,Birnbaum F,Hansen LL,Reinhard T

    更新日期:2005-07-01 00:00:00

  • Posterior capsule dehiscence during phacoemulsification and manual extracapsular cataract extraction: comparison of outcomes.

    abstract:PURPOSE:To compare the intraoperative behavior and postoperative outcomes of posterior capsule dehiscence during phacoemulsification and during manual extracapsular cataract extraction (ECCE). SETTING:L.V. Prasad Eye Institute, Hyderabad, India. METHODS:This study was a retrospective chart review of consecutive cases...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(02)01696-6

    authors: Basti S,Garg P,Reddy MK

    更新日期:2003-03-01 00:00:00

  • In vitro optical quality differences between multifocal apodized diffractive intraocular lenses.

    abstract:PURPOSE:To compare the in vitro optical quality of multifocal apodized intraocular lenses (IOLs) at different focal points. SETTING:University of Valencia, Valencia, Spain. DESIGN:Experimental study. METHODS:The Acrysof Restor +3.0 diopter (D) multifocal IOL with 2 main foci (bifocal IOL) and the Finevision multifoc...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2012.12.038

    authors: Montés-Micó R,Madrid-Costa D,Ruiz-Alcocer J,Ferrer-Blasco T,Pons AM

    更新日期:2013-06-01 00:00:00

  • Corneal crosslinking: riboflavin concentration in corneal stroma exposed with and without epithelium.

    abstract:PURPOSE:To evaluate intrastromal concentrations of riboflavin with and without epithelium to ensure the efficacy and safety of corneal crosslinking (CXL) by the standard and transepithelial procedures. SETTING:Department of Ophthalmology and Department of Pharmacology G. Segre, Siena University, Siena, Italy. METHODS...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2009.01.009

    authors: Baiocchi S,Mazzotta C,Cerretani D,Caporossi T,Caporossi A

    更新日期:2009-05-01 00:00:00

  • Siepser slipknot for McCannel iris-suture fixation of subluxated intraocular lenses.

    abstract::In 8 cases that presented with symptomatic posterior chamber IOL subluxation, a McCannel polypropylene (Prolene) suture was used with the Siepser slipknot technique to successfully refixate the IOLs to the iris. There were no intraoperative complications, and a round pupil was preserved in all cases. ...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2003.10.025

    authors: Chang DF

    更新日期:2004-06-01 00:00:00

  • Corneal crosslinking: Current protocols and clinical approach.

    abstract::Members of the ASCRS Cornea Clinical Committee performed a review of the current literature on the corneal crosslinking (CXL) procedure for treating corneal ectasia. The members explored the data on the techniques currently in use and under investigation, including their advantages, safety profiles, risks, and cost an...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章,评审

    doi:10.1016/j.jcrs.2019.06.027

    authors: Beckman KA,Gupta PK,Farid M,Berdahl JP,Yeu E,Ayres B,Chan CC,Gomes JAP,Holland EJ,Kim T,Starr CE,Mah FS,ASCRS Cornea Clinical Committee.

    更新日期:2019-11-01 00:00:00

  • Simple method for accurate alignment in toric phakic and aphakic intraocular lens implantation.

    abstract::A simple technique for the accurate surgical alignment of toric phakic and aphakic intraocular lenses (IOLs) is described. The mathematical relationship between toric misalignment and cylinder error is reviewed to demonstrate the importance of toric lens alignment in the setting of increased rotational stability with ...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2008.04.041

    authors: Ma JJ,Tseng SS

    更新日期:2008-10-01 00:00:00

  • Meridional differences in internal dimensions of the anterior segment in human eyes evaluated with 2 imaging systems.

    abstract:PURPOSE:To evaluate meridional differences in angle-to-angle (A-A) and sulcus-to-sulcus (S-S) dimensions in human eyes using very high frequency ultrasound (VHF US) and anterior segment optical coherence tomography (AS-OCT). SETTING:John A. Moran Eye Center, University of Utah, USA; Berlin Eye Research Institute, Germ...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2008.03.033

    authors: Werner L,Lovisolo C,Chew J,Tetz M,Müller M

    更新日期:2008-07-01 00:00:00

  • Stand-alone surgery for mild to moderate glaucoma and ocular surface disease: June consultation #1.

    abstract::A generally healthy and independent 83-year-old man presented with long-standing, mild to moderate glaucoma. He had uneventful cataract surgery several years earlier. He also had previous selective laser trabeculoplasty (SLT) with only slight reduction in his intraocular pressure (IOP). His untreated IOP was middle to...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1097/j.jcrs.0000000000000244

    authors:

    更新日期:2020-06-01 00:00:00

  • Step-down technique.

    abstract::From the beginning of nuclear fragment removal to the end, we progressively reduce all the parameters, ie, energy, vacuum, and aspiration flow rate, in a step-by-step manner proportionate to the posterior capsule exposure. This promotes adaptation of various parameters to the appropriate stages of surgery and allows t...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(03)00121-4

    authors: Vasavada AR,Raj S

    更新日期:2003-06-01 00:00:00

  • Analysis of astigmatic keratotomy.

    abstract::Eighty-two keratotomy procedures were performed for both idiopathic and postsurgical astigmatism or myopic astigmatism and analyzed for efficacy using vector and linear regression analysis. Delta keratometry values (delta K) were computed for each case as delta K in the desired axis of effect using vector analysis. Si...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(89)80134-8

    authors: Agapitos PJ,Lindstrom RL,Williams PA,Sanders DR

    更新日期:1989-01-01 00:00:00

  • Repositioning and follow-up of intralenticular dexamethasone implant.

    abstract::We report the case of a 54-year-old man who attended our emergency department complaining of severe floaters and decreased vision in his right eye. Seven days earlier, a dexamethasone intravitreal implant (Oxurdex) had been placed for a noninfectious posterior uveitis. Slitlamp examination showed the implant had penet...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2013.06.003

    authors: Munteanu M,Rosca C

    更新日期:2013-08-01 00:00:00

  • Anterior periocular anesthesia: five years experience.

    abstract::Safe, effective administration of local anesthesia prior to ocular surgery is a primary concern of ophthalmologists and variations in the technique and method of delivering anesthesia have been developed. Retrobulbar anesthesia, although considered safe and effective, can have serious complications. Using periocular a...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(13)80861-9

    authors: Bloomberg LB

    更新日期:1991-07-01 00:00:00

  • Ocular explosion after peribulbar anesthesia.

    abstract::We report 3 cases of globe rupture after peribulbar anesthesia. We discuss the predisposing factors, presenting features, and visual outcome after this complication. Globe explosion is a severe complication of inadvertent intraocular injection during peribulbar anesthesia. Visual outcome after vitrectomy is generally ...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(01)01034-3

    authors: Brar GS,Ram J,Dogra MR,Pandav SS,Sharma A,Kaushik S,Gupta A

    更新日期:2002-03-01 00:00:00

  • Water-mediated lysis of lens epithelial cells attached to lens capsule.

    abstract:PURPOSE:To investigate the effect of distilled deionized water (DDW) on lens epithelial cells (LECs) attached to the lens capsule. SETTING:Wound Healing Research Laboratory, Center for Vision Research, Westmead Hospital, Sydney, NSW, Australia. METHODS:Anterior capsulotomy specimens taken during routine cataract surg...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2004.01.028

    authors: Crowston JG,Healey PR,Hopley C,Neilson G,Milverton EJ,Maloof A

    更新日期:2004-05-01 00:00:00

  • Long-term results of myopic epikeratoplasty.

    abstract::Twenty-three eyes of 20 patients who had had myopic epikeratoplasty were evaluated and the mean 21-month postoperative results (range: 12 to 47 months) tabulated. Average preoperative myopia was -16.7 diopters (D) spherical equivalent (range: -10 to -33 D), and average postoperative refractive correction was 13 D. Of ...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(13)80305-7

    authors: Kim WJ,Lee JH

    更新日期:1993-05-01 00:00:00

  • Effect of heparin-surface-modified poly(methyl methacrylate) intraocular lenses on the postoperative inflammation in an Asian population.

    abstract:PURPOSE:To compare the efficacy of heparin-surface-modified (HSM), poly(methyl methacrylate) (PMMA) posterior chamber intraocular lenses (IOLs) with that of unmodified PMMA IOLs in reducing postoperative complications caused by inflammatory reactions after extracapsular cataract extraction in an Asian population. SETT...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 临床试验,杂志文章,多中心研究,随机对照试验

    doi:10.1016/s0886-3350(96)80170-2

    authors: Lai YK,Fan RF

    更新日期:1996-01-01 00:00:00

  • Improving estimation of corneal refractive power by measuring the posterior curvature of the cornea.

    abstract::We developed a formula to measure the posterior curvature of the cornea. In our study, real corneal power in 51 eyes was calculated by using anterior and posterior curvatures and corneal thickness. The corneal refractive index was found to be a variable value between 1.3243 and 1.3339 (mean 1.3304 +/- 0.0003). ...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(13)80151-4

    authors: Eryildirim A,Ozkan T,Eryildirim S,Kaynak S,Cingil G

    更新日期:1994-03-01 00:00:00

  • Intrastromal corneal ring segment implantation to correct astigmatism after penetrating keratoplasty.

    abstract:PURPOSE:To evaluate the clinical outcomes of implantation of Ferrara intrastromal corneal ring segments (ICRS) in patients with astigmatism after penetrating keratoplasty (PKP). SETTING:Private clinic, Belo Horizonte, Brazil. DESIGN:Retrospective consecutive case series. METHODS:Chart records of post-PKP patients wh...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2011.12.037

    authors: Coscarelli S,Ferrara G,Alfonso JF,Ferrara P,Merayo-Lloves J,Araújo LP,Machado AP,Lyra JM,Torquetti L

    更新日期:2012-06-01 00:00:00

  • High-vacuum clothesline technique for elevation and repositioning of posteriorly dislocated intraocular lens.

    abstract::We describe a technique to simplify the retrieval process of an intraocular lens (IOL) that has fallen into the posterior segment of the eye. A high-vacuum level setting is used to achieve fixation of the IOL to the vitrectomy tip, permitting the IOL to be elevated into the anterior segment. The clothesline technique ...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2017.12.018

    authors: Mackool RJ Sr,Mackool RJ Jr,Solinsky BM

    更新日期:2018-03-01 00:00:00

  • Effect of laser in situ keratomileusis on optic nerve head topography and retinal nerve fiber layer thickness.

    abstract:PURPOSE:To determine whether laser in situ keratomileusis (LASIK) produces significant changes in optic nerve head (ONH) topography and retinal nerve fiber layer (RNFL) thickness as measured by the Heidelberg Retina Tomograph (HRT) and to evaluate the potential neuroprotective effect of topical betaxolol on these chang...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1016/s0886-3350(03)00466-8

    authors: Whitson JT,McCulley JP,Cavanagh HD,Song J,Bowman RW,Hertzog L

    更新日期:2003-12-01 00:00:00

  • Corneal collagen crosslinking with riboflavin and ultraviolet A to treat induced keratectasia after laser in situ keratomileusis.

    abstract:PURPOSE:To determine whether riboflavin and ultraviolet-A (UVA) corneal crosslinking can be used as an alternative therapy to prevent the progression of keratectasia. SETTING:Institute for Refractive and Ophthalmic Surgery, Zurich, Switzerland, and a private clinic, Athens, Greece. METHODS:Corneal crosslinking was pe...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2007.07.028

    authors: Hafezi F,Kanellopoulos J,Wiltfang R,Seiler T

    更新日期:2007-12-01 00:00:00

  • Contrast sensitivity measured by 2 methods after photorefractive keratectomy.

    abstract:PURPOSE:To study contrast sensitivity in eyes that had flying-spot excimer laser photorefractive keratectomy (PRK) and to compare a subjective method (Vision Contrast Test System [VCTS] 6500) and an objective method (visual evoked potential [VEP]) of measuring contrast sensitivity. SETTING:Istituto Clinica Oculistica,...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(00)00405-3

    authors: Vetrugno M,Quaranta GM,Maino A,Mossa F,Cardia L

    更新日期:2000-06-01 00:00:00