Is nonoperative management of partial distal biceps tears really successful?

Abstract:

BACKGROUND:The current treatment of partial distal biceps tears is a period of nonoperative management, followed by surgery, if symptoms persist. Little is known about the success rate and outcomes of nonoperative management of this illness. METHODS:We identified 132 patients with partial distal biceps tears through an International Classification of Diseases, Ninth Revision code query of our institution's database. Patient records were reviewed to abstract demographic information and confirm partial tears of the distal biceps tendon based on clinical examination findings and confirmatory magnetic resonance imaging (MRI). Seventy-four patients completed an outcome survey. RESULTS:In our study, 55.7% of the contacted patients who tried a nonoperative course (34 of 61 patients) ultimately underwent surgery, and 13 patients underwent immediate surgery. High-need patients, as defined by occupation, were more likely to report that they recovered ideally if they underwent surgery, as compared with those who did not undergo surgery (odds ratio, 11.58; P = .0138). For low-need patients, the same analysis was not statistically significant (P = .139). There was no difference in satisfaction scores between patients who tried a nonoperative course before surgery and those who underwent immediate surgery (P = .854). An MRI-diagnosed tear of greater than 50% was a predictor of needing surgery (odds ratio, 3.0; P = .006). CONCLUSIONS:This study has identified clinically relevant information for the treatment of partial distal biceps tears, including the following: the failure rate of nonoperative treatment, the establishment of MRI percent tear as a predictor of failing nonoperative management, the benefit of surgery for the high-need occupational group, and the finding that nonoperative management does not negatively affect outcome if subsequent surgery is necessary.

journal_name

J Shoulder Elbow Surg

authors

Bauer TM,Wong JC,Lazarus MD

doi

10.1016/j.jse.2017.12.010

subject

Has Abstract

pub_date

2018-04-01 00:00:00

pages

720-725

issue

4

eissn

1058-2746

issn

1532-6500

pii

S1058-2746(17)30829-7

journal_volume

27

pub_type

杂志文章
  • Shoulder arthroplasty in morbidly obese patients.

    abstract:BACKGROUND:The purpose of this study was to determine the results, complications, and failure rates of shoulder arthroplasty in morbidly obese patients. METHODS:Between 1994 and 2005, 45 shoulder arthroplasties were performed for osteoarthritis in patients with a BMI greater than 40. Forty-one shoulders were followed ...

    journal_title:Journal of shoulder and elbow surgery

    pub_type: 杂志文章

    doi:10.1016/j.jse.2009.02.006

    authors: Linberg CJ,Sperling JW,Schleck CD,Cofield RH

    更新日期:2009-11-01 00:00:00

  • Specific patient-related prognostic factors for rotator cuff repair: a systematic review.

    abstract:BACKGROUND:Many studies that describe factors affecting outcome in primary rotator cuff repair (RCR) have been published, but so far there is no review that summarizes them. This systematic review was conducted to identify prognostic factors influencing functional (clinical) outcome and radiologically proven cuff integ...

    journal_title:Journal of shoulder and elbow surgery

    pub_type: 杂志文章,评审

    doi:10.1016/j.jse.2014.01.001

    authors: Lambers Heerspink FO,Dorrestijn O,van Raay JJ,Diercks RL

    更新日期:2014-07-01 00:00:00

  • Is the Simple Shoulder Test a valid outcome instrument for shoulder arthroplasty?

    abstract:BACKGROUND:The Simple Shoulder Test (SST) is a brief, inexpensive, and widely used patient-reported outcome tool, but it has not been rigorously evaluated for patients having shoulder arthroplasty. The goal of this study was to rigorously evaluate the validity of the SST for outcome assessment in shoulder arthroplasty ...

    journal_title:Journal of shoulder and elbow surgery

    pub_type: 杂志文章

    doi:10.1016/j.jse.2017.03.029

    authors: Hsu JE,Russ SM,Somerson JS,Tang A,Warme WJ,Matsen FA 3rd

    更新日期:2017-10-01 00:00:00

  • The flat spot of the proximal ulna: a useful anatomic landmark in total elbow arthroplasty.

    abstract::The relationship between the flat subcutaneous dorsal surface (flat spot) of the ulna and the anatomic flexion axis of the elbow was investigated in 68 cadaveric ulnae. The flat spot and the guiding ridge of the greater sigmoid notch were digitized with an electromagnetic tracking device. The area of the flat spot, as...

    journal_title:Journal of shoulder and elbow surgery

    pub_type: 杂志文章

    doi:10.1016/j.jse.2003.11.003

    authors: Duggal N,Dunning CE,Johnson JA,King GJ

    更新日期:2004-03-01 00:00:00

  • Clinical evaluation of sodium hyaluronate for the treatment of patients with rotator cuff tear.

    abstract::A randomized study of two types of conservative treatment of 78 shoulders in 78 patients with rotator cuff tears was performed. Twenty-five milligrams of sodium hyaluronate (SH) was injected into shoulders in one group (SH group) and 2 mg of dexamethasone was injected in the other group (steroid group). Injection of e...

    journal_title:Journal of shoulder and elbow surgery

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1067/mse.2001.113501

    authors: Shibata Y,Midorikawa K,Emoto G,Naito M

    更新日期:2001-05-01 00:00:00

  • Treatment of chronic glenoid defects in the setting of recurrent anterior shoulder instability: a systematic review.

    abstract:OBJECTIVE:The purpose is to systematically evaluate the literature regarding treatment of chronic glenoid bone defects in the setting of recurrent anterior shoulder instability to determine if, from an evidence-based outcomes approach, one technique may be recommended over the other. METHODS:PubMed 1966-2009, Embase 1...

    journal_title:Journal of shoulder and elbow surgery

    pub_type: 杂志文章,评审

    doi:10.1016/j.jse.2010.01.011

    authors: Beran MC,Donaldson CT,Bishop JY

    更新日期:2010-07-01 00:00:00

  • Impaction autografting: bone-preserving, secure fixation of a standard humeral component.

    abstract:BACKGROUND:When fixed with bone ingrowth, a tight diaphyseal press fit, or cement, the humeral component of a shoulder arthroplasty may present problems of malposition, stress shielding, or periprosthetic fracture or difficulty with removal at revision arthroplasty. We have avoided the need for these fixation methods b...

    journal_title:Journal of shoulder and elbow surgery

    pub_type: 杂志文章

    doi:10.1016/j.jse.2016.03.008

    authors: Lucas RM,Hsu JE,Gee AO,Neradilek MB,Matsen FA 3rd

    更新日期:2016-11-01 00:00:00

  • Corrective osteotomy for cubitus varus in middle-aged patients.

    abstract:BACKGROUND:We reviewed the results of corrective osteotomy for cubitus varus in middle-aged patients to investigate whether it is recommended in this age group. MATERIALS AND METHODS:We studied 20 consecutive patients who underwent 3-dimensional corrective osteotomy at an average age of 47.9 years (range, 41-55 years)...

    journal_title:Journal of shoulder and elbow surgery

    pub_type: 杂志文章

    doi:10.1016/j.jse.2011.04.003

    authors: Lim TK,Koh KH,Lee DK,Park MJ

    更新日期:2011-09-01 00:00:00

  • The influence of intramedullary fixation on figure-of-eight wiring for surgical neck fractures of the proximal humerus: a biomechanical comparison.

    abstract::The resistance to torsional load was measured in a human cadaver model of a surgical neck fracture. Ten fresh-frozen human cadaver shoulders were thawed, dissected free of soft tissue attachments, and analyzed with dual energy x-ray absorptiometry to establish bone mineral density. Osteotomies were fixed with figure-o...

    journal_title:Journal of shoulder and elbow surgery

    pub_type: 杂志文章

    doi:10.1016/s1058-2746(97)70048-x

    authors: Williams GR Jr,Copley LA,Iannotti JP,Lisser SP

    更新日期:1997-09-01 00:00:00

  • The chondral print sign: what does it really mean?

    abstract:BACKGROUND:The chondral print (CP) sign is a chondral change on the humeral head underneath the long head of the biceps (LHB) tendon. Several suggested causative links have been described, but the pathologic mechanism remains unclear. METHODS:We designed this prospective cohort association study of 102 consecutive sho...

    journal_title:Journal of shoulder and elbow surgery

    pub_type: 杂志文章

    doi:10.1016/j.jse.2016.11.003

    authors: Domos P,Neogi DS,Longo UG,Ahrens PM

    更新日期:2017-06-01 00:00:00

  • Effectiveness of multidetector computed tomography arthrography for the diagnosis of shoulder pathology: comparison with magnetic resonance imaging with arthroscopic correlation.

    abstract:HYPOTHESIS:This study evaluated the diagnostic efficacy of computed tomography arthrography (CTA) in the assessment of various shoulder pathologies with arthroscopic correlation. We hypothesized that CTA would be cost-effective and effectively comparable with magnetic resonance arthrography (MRA) for assessing labral d...

    journal_title:Journal of shoulder and elbow surgery

    pub_type: 杂志文章

    doi:10.1016/j.jse.2009.04.012

    authors: Oh JH,Kim JY,Choi JA,Kim WS

    更新日期:2010-01-01 00:00:00

  • Obesity is associated with increased postoperative complications after operative management of distal humerus fractures.

    abstract:BACKGROUND:Distal humerus fractures commonly require surgical intervention, including open reduction and internal fixation (ORIF) and, more recently in elderly, low-demand individuals, total elbow arthroplasty (TEA). The association of obesity with complications after either of these procedures has not previously been ...

    journal_title:Journal of shoulder and elbow surgery

    pub_type: 杂志文章

    doi:10.1016/j.jse.2015.04.019

    authors: Werner BC,Rawles RB,Jobe JT,Chhabra AB,Freilich AM

    更新日期:2015-10-01 00:00:00

  • Reverse total shoulder arthroplasty for acute proximal humeral fracture: comparison to open reduction-internal fixation and hemiarthroplasty.

    abstract:BACKGROUND:Significant controversy surrounds optimal treatment of displaced 4-part proximal humeral fractures. Reverse total shoulder arthroplasty (RTSA) has recently been proposed as an alternative to hemiarthroplasty (HA) and open reduction-internal fixation (ORIF). Several authors have questioned the additional impl...

    journal_title:Journal of shoulder and elbow surgery

    pub_type: 杂志文章

    doi:10.1016/j.jse.2013.07.044

    authors: Chalmers PN,Slikker W 3rd,Mall NA,Gupta AK,Rahman Z,Enriquez D,Nicholson GP

    更新日期:2014-02-01 00:00:00

  • The effect of a local application of fibroblast growth factor-2 on tendon-to-bone remodeling in rats with acute injury and repair of the supraspinatus tendon.

    abstract:METHODS:We investigated the effect of application of fibroblast growth factor (FGF)-2 on the tendon-to-bone remodeling of repaired supraspinatus tendon in rats subjected to bilateral detachment. FGF-2 (100 mg/kg) in a fibrin sealant or sealant alone was applied on the right and left shoulders, respectively. Twelve anim...

    journal_title:Journal of shoulder and elbow surgery

    pub_type: 杂志文章

    doi:10.1016/j.jse.2009.01.013

    authors: Ide J,Kikukawa K,Hirose J,Iyama K,Sakamoto H,Fujimoto T,Mizuta H

    更新日期:2009-05-01 00:00:00

  • Risk factors for periprosthetic infection after reverse shoulder arthroplasty.

    abstract:BACKGROUND:Management of periprosthetic infection after reverse shoulder arthroplasty (RSA) remains a challenge. Whereas the infection rate after RSA has improved, more information would be helpful to identify patient risk factors for infection after RSA. The purpose of this study was to evaluate risk factors for infec...

    journal_title:Journal of shoulder and elbow surgery

    pub_type: 杂志文章

    doi:10.1016/j.jse.2014.05.020

    authors: Morris BJ,O'Connor DP,Torres D,Elkousy HA,Gartsman GM,Edwards TB

    更新日期:2015-02-01 00:00:00

  • Effect of total shoulder replacements on airport security screening in the post-9/11 era.

    abstract::There are few reports in the literature on the effect of orthopaedic implants on airport security devices and none on shoulder arthroplasty implants after September 11, 2001. Since 9/11, airport security screening devices have become more sensitive in response to the increasing threat of terrorism. Often, patients wit...

    journal_title:Journal of shoulder and elbow surgery

    pub_type: 杂志文章

    doi:10.1016/j.jse.2006.10.016

    authors: Dines JS,Elkousy H,Edwards TB,Gartsman GM,Dines DM

    更新日期:2007-07-01 00:00:00

  • The effect of comorbidity and duration of nonunion on outcome after surgical treatment for nonunion of the humerus.

    abstract::The purpose of our study was to assess the effect of comorbidity and duration of nonunion on the general health status and joint-specific outcome of a group of patients treated for nonunion of the humeral shaft. We identified 25 consecutive patients with nonunion of the humeral shaft, all treated with compression plat...

    journal_title:Journal of shoulder and elbow surgery

    pub_type: 杂志文章

    doi:10.1016/s1058-2746(98)90222-1

    authors: Otsuka NY,McKee MD,Liew A,Richards RR,Waddell JP,Powell JN,Schemitsch EH

    更新日期:1998-03-01 00:00:00

  • The effect of biceps reattachment site.

    abstract:BACKGROUND:We hypothesize that an anatomic repair of the distal biceps tendon would recreate native tendon moment arm and forearm rotation, while a nonanatomic insertion would compromise moment arm and forearm rotation. METHODS:Isometric supination torque was measured at 60° of pronation, neutral, and 60° of supinatio...

    journal_title:Journal of shoulder and elbow surgery

    pub_type: 杂志文章

    doi:10.1016/j.jse.2010.05.027

    authors: Schmidt CC,Weir DM,Wong AS,Howard M,Miller MC

    更新日期:2010-12-01 00:00:00

  • Comparison of the subjective elbow value and the Mayo elbow performance score.

    abstract:BACKGROUND:The aim of this study was to evaluate the subjective elbow value (SEV) and compare it with the Mayo Elbow Performance Score (MEPS). The SEV is defined as the patient's subjective estimation of the elbow as a percentage of a normal elbow, which would correspond to 100%. METHODS:The MEPS and the SEV were pros...

    journal_title:Journal of shoulder and elbow surgery

    pub_type: 杂志文章

    doi:10.1016/j.jse.2013.11.018

    authors: Schneeberger AG,Kösters MC,Steens W

    更新日期:2014-03-01 00:00:00

  • Transfusion after shoulder arthroplasty: an analysis of rates and risk factors.

    abstract:HYPOTHESIS:Advancing age, lower preoperative hemoglobin levels, and more complex procedures are risk factors in transfusion requirements following shoulder arthroplasty. MATERIALS AND METHODS:We retrospectively reviewed the records of 196 consecutive shoulder arthroplasties performed by a single surgeon (including 113...

    journal_title:Journal of shoulder and elbow surgery

    pub_type: 杂志文章

    doi:10.1016/j.jse.2008.08.005

    authors: Gruson KI,Accousti KJ,Parsons BO,Pillai G,Flatow EL

    更新日期:2009-03-01 00:00:00

  • Anatomic variance of the coracoclavicular ligaments.

    abstract::The coracoclavicular ligaments vary widely in morphology and anatomic descriptions. Few authors have adequately described the coracoclavicular ligaments' anatomy, and a number of discrepancies exist in the anatomy literature. This study examines the complex anatomy of the coracoclavicular ligaments and their relations...

    journal_title:Journal of shoulder and elbow surgery

    pub_type: 杂志文章

    doi:10.1067/mse.2001.118480

    authors: Harris RI,Vu DH,Sonnabend DH,Goldberg JA,Walsh WR

    更新日期:2001-11-01 00:00:00

  • Platelet-rich plasma in fibrin matrix to augment rotator cuff repair: a prospective, single-blinded, randomized study with 2-year follow-up.

    abstract:BACKGROUND:Application of autologous platelet-rich plasma in fibrin matrix (PRPFM) improves tendon healing in patients undergoing arthroscopic rotator cuff repair. We performed a prospective, randomized, single-blinded study of 76 patients, with an α level of 5% and power of 80%. MATERIALS AND METHODS:Seventy-six pati...

    journal_title:Journal of shoulder and elbow surgery

    pub_type: 杂志文章,随机对照试验

    doi:10.1016/j.jse.2018.05.003

    authors: Walsh MR,Nelson BJ,Braman JP,Yonke B,Obermeier M,Raja A,Reams M

    更新日期:2018-09-01 00:00:00

  • Evaluation of intratester and intertester reliability of the Constant-Murley shoulder assessment.

    abstract::This study evaluated the reliability of the Constant-Murley Score. Two testers assessed 63 patients twice on the same day using the original publication by Constant and Murley. The intratester reliability of the total score was high and the differences between the tests were small; 2 of 14 items were unreliable. The i...

    journal_title:Journal of shoulder and elbow surgery

    pub_type: 杂志文章

    doi:10.1016/j.jse.2007.06.024

    authors: Rocourt MH,Radlinger L,Kalberer F,Sanavi S,Schmid NS,Leunig M,Hertel R

    更新日期:2008-03-01 00:00:00

  • A biomechanical comparison of repair techniques in posterior type II superior labral anterior and posterior (SLAP) lesions.

    abstract::The purpose of this study was to compare the 3 different fixation methods of posterior type superior labral anterior posterior (SLAP) II lesion. Fifteen cadavers were randomly divided into 3 groups to compare the initial strength of 3 different fixation methods in posterior type II SLAP lesions. Group I used 1 anchor ...

    journal_title:Journal of shoulder and elbow surgery

    pub_type: 杂志文章

    doi:10.1016/j.jse.2007.03.025

    authors: Yoo JC,Ahn JH,Lee SH,Lim HC,Choi KW,Bae TS,Lee CY

    更新日期:2008-01-01 00:00:00

  • Bilateral ruptures of the distal biceps brachii tendon.

    abstract:BACKGROUND:The purpose of this study was to identify characteristics associated with bilateral ruptures of the distal biceps tendons. METHODS:We present a retrospective case series of 25 patients who sustained non-simultaneous bilateral distal biceps brachii tendon ruptures that were repaired surgically, with follow-u...

    journal_title:Journal of shoulder and elbow surgery

    pub_type: 杂志文章

    doi:10.1016/j.jse.2009.01.029

    authors: Schneider A,Bennett JM,O'Connor DP,Mehlhoff T,Bennett JB

    更新日期:2009-09-01 00:00:00

  • Prognosis for recovery of posterior interosseous nerve palsy after distal biceps repair.

    abstract:BACKGROUND:There is very little information on the incidence of and usual recovery period for posterior interosseous nerve (PIN) palsies after distal biceps repair. This study examined the incidence and the time to resolution of PIN palsies in a large consecutive series of primary distal biceps repairs. MATERIALS AND ...

    journal_title:Journal of shoulder and elbow surgery

    pub_type: 杂志文章

    doi:10.1016/j.jse.2012.08.001

    authors: Nigro PT,Cain R,Mighell MA

    更新日期:2013-01-01 00:00:00

  • Use of bipolar radiofrequency energy in delayed repair of acute supraspinatus tears in rats.

    abstract::The purpose of this study is to determine if bipolar radiofrequency energy (bRFE) can enhance delayed surgical repair of acute supraspinatus tendon tears. Bilateral supraspinatus tendon tears were created in 42 Sprague-Dawley rats and repaired at 6 weeks either with or without bRFE augmentation. There were 8 control (...

    journal_title:Journal of shoulder and elbow surgery

    pub_type: 杂志文章

    doi:10.1016/j.jse.2006.11.008

    authors: Lin JL,Carreira D,Ponnappan R,Volz B,Cole BJ

    更新日期:2007-09-01 00:00:00

  • Use of locking plates in the treatment of proximal humerus fractures.

    abstract:BACKGROUND/HYPOTHESIS:Open reduction and internal fixation (ORIF) using locked plating has demonstrated promise in the treatment of displaced proximal humerus fractures. The purpose of this article is to describe the surgical technique and to report early clinical results with this technique. METHODS:Important surgica...

    journal_title:Journal of shoulder and elbow surgery

    pub_type: 杂志文章

    doi:10.1016/j.jse.2010.01.001

    authors: Ricchetti ET,Warrender WJ,Abboud JA

    更新日期:2010-03-01 00:00:00

  • Early postoperative complications after Latarjet procedure: a single-institution experience over 10 years.

    abstract:BACKGROUND:The Latarjet procedure is an effective procedure for the treatment of anterior glenohumeral joint instability; however, the complications are concerning. The purpose of this study was to review a single institution's experience with the Latarjet procedure for recurrent anterior glenohumeral instability speci...

    journal_title:Journal of shoulder and elbow surgery

    pub_type: 杂志文章

    doi:10.1016/j.jse.2020.09.002

    authors: Hendy BA,Padegimas EM,Kane L,Harper T,Abboud JA,Lazarus MD,Romeo AA,Namdari S

    更新日期:2020-09-30 00:00:00

  • Mechanical testing of shoulder prostheses and recommendations for glenoid design.

    abstract::Glenoid component loosening generates the greatest concern among surgeons performing total shoulder arthroplasty. Laboratory testing of glenoid prostheses may lead to improved design, subsequently leading to a reduction in the incidence of clinical loosening. The goals of this study were to develop a laboratory test m...

    journal_title:Journal of shoulder and elbow surgery

    pub_type: 杂志文章

    doi:10.1067/mse.2000.105451

    authors: Anglin C,Wyss UP,Pichora DR

    更新日期:2000-07-01 00:00:00