Efficacy of periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) for shoulder magnetic resonance (MR) imaging.

Abstract:

OBJECTIVES:To elucidate the utility of PROPELLER for motion artefact reduction on shoulder MRI and to examine the influence of streak artefacts on diagnosis of clinical images. METHODS:15 healthy volunteers and 48 patients underwent shoulder MRI with/without PROPELLER (coronal oblique proton density-fast spin echo [PD-FSE], sagittal oblique T2-FSE). In a volunteer study, all sequences were performed in both static and exercise-loaded conditions. Two radiologists graded artefacts and delineation of various anatomical structures in the volunteer study and motion and streak artefacts in the clinical study. Mean scores were compared between sequences with/without PROPELLER. In the clinical study, mean scores of motion artefacts were compared with mean scores of streak artefacts. Wilcoxon signed-rank test was used for all comparisons. RESULTS:In both studies, PROPELLER significantly reduced motion artefacts (P<0.05). In the volunteer study, it significantly improved delineations in sagittal oblique images in the exercise-loaded condition (P<0.05). In the clinical study, streak artefacts appeared dominantly on images with PROPELLER (P<0.05), but influenced diagnosis to a lesser extent than motion artefacts. CONCLUSION:PROPELLER can reduce motion artefacts in shoulder MRI. While it does cause streak artefacts, it affects diagnosis to a lesser extent.

journal_name

Eur J Radiol

authors

Nagatomo K,Yabuuchi H,Yamasaki Y,Narita H,Kumazawa S,Kojima T,Sakai N,Masaki M,Kimura H

doi

10.1016/j.ejrad.2016.07.008

subject

Has Abstract

pub_date

2016-10-01 00:00:00

pages

1735-1743

issue

10

eissn

0720-048X

issn

1872-7727

pii

S0720-048X(16)30218-2

journal_volume

85

pub_type

临床试验,杂志文章
  • MRI in long-term evaluation of reconstructed hind-feet of land-mine trauma patients.

    abstract:INTRODUCTION:The purpose of this study was to assess the flap reconstructed hind feet of patients with MRI who were traumatized by land-mine. MATERIALS AND METHODS:T1 and T2 weighted images were obtained in 7 patients, 12 months later the reconstruction of their hind feet by myocutaneous flaps after land-mine trauma. ...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2006.11.018

    authors: Sanal HT,Bulakbasi N,Kocaoglu M,Yildirim D

    更新日期:2007-08-01 00:00:00

  • Digital chest radiography--comparing two types of CRT monitors in a ROC experiment with a chest phantom.

    abstract::Two principally different 1000-line CRT (cathode ray tube) monitors connected to a digital image intensifier system for chest radiography were compared in terms of image quality and viewing comfort. Image quality was assessed by means of ROC analysis. Five observers tried to find simulated pathology positioned over th...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/0720-048x(96)00750-4

    authors: Kheddache S,Angelhed JE,Månsson LG,Denbratt L,Gottfridsson B,Olmarker A

    更新日期:1996-06-01 00:00:00

  • The future of radiology augmented with Artificial Intelligence: A strategy for success.

    abstract::The rapid development of Artificial Intelligence/deep learning technology and its implementation into routine clinical imaging will cause a major transformation to the practice of radiology. Strategic positioning will ensure the successful transition of radiologists into their new roles as augmented clinicians. This p...

    journal_title:European journal of radiology

    pub_type: 杂志文章,评审

    doi:10.1016/j.ejrad.2018.03.019

    authors: Liew C

    更新日期:2018-05-01 00:00:00

  • Patients 65 years and older with incidental pancreatic cysts: Is there a relationship between all-cause mortality and imaging follow-up?

    abstract:PURPOSE:To assess the relationship between imaging follow-up and all-cause mortality in subjects ≥65 years with and without incidental pancreatic cysts (IPC). METHODS AND MATERIALS:Patients ≥65 years with abdominal CT/MR 11/1/01-11/1/11 were included. IPC group included subjects with IPC on CT/MR report; No-IPC group ...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2016.03.008

    authors: Flusberg M,Paroder V,Kobi M,Rozenblit AM,Chernyak V

    更新日期:2016-06-01 00:00:00

  • Reducing artifacts from total hip replacements in dual layer detector CT: Combination of virtual monoenergetic images and orthopedic metal artifact reduction.

    abstract:PURPOSE:To evaluate the reduction of artifacts caused by total hip replacements (THR) in dual-layer DECT (DLCT) provided by the combination of virtual monoenergetic images (VMI) and orthopedic metal artifact reduction (MAR). MATERIALS AND METHODS:A total of 24 consecutive patients carrying THR, who received DLCT, were...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2018.12.008

    authors: Neuhaus V,Grosse Hokamp N,Zopfs D,Laukamp K,Lennartz S,Abdullayev N,Maintz D,Borggrefe J

    更新日期:2019-02-01 00:00:00

  • Renal MDCT.

    abstract::Multidetector CT has expanded the utility of CT by improving longitudinal resolution and acquisition speed. Applications include diagnosis of renal vascular and parenchymal injuries, renal tumor diagnosis and staging, the emerging field of CT urography and CT angiography. This summary review illustrates MDCT approache...

    journal_title:European journal of radiology

    pub_type: 杂志文章,评审

    doi:10.1016/s0720-048x(03)00003-2

    authors: Foley WD

    更新日期:2003-03-01 00:00:00

  • FDG-PET-CT and whole-body MRI for triage in patients planned for radioembolisation therapy.

    abstract:PURPOSE:The purpose was to evaluate the potential of FDG-PET-CT and whole-body MRI (WB-MRI) as diagnostic triage methods for patients planned for radioembolisation of metastatic liver disease. MATERIALS AND METHODS:135 patients with multifocal liver metastases were evaluated for potential palliative therapy with radio...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2011.02.018

    authors: Schmidt GP,Paprottka P,Jakobs TF,Hoffmann RT,Baur-Melnyk A,Haug A,Notohamiprodjo M,Baur-Melnyk A,Nikolaou K,Reiser MF,Rist C

    更新日期:2012-03-01 00:00:00

  • Retrieval of intravascular foreign bodies with goose neck snare.

    abstract:PURPOSE:to evaluate the efficacy and advantages of the snare systems in the retrieval of foreign bodies from vascular system. MATERIALS AND METHODS:the snare technique has been used for intravascular foreign body retrieval. We performed percutaneous extraction of intravascular foreign bodies using combination multipur...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/S0720-048X(03)00078-0

    authors: Koseoglu K,Parildar M,Oran I,Memis A

    更新日期:2004-03-01 00:00:00

  • Image quality performance of liquid crystal display systems: influence of display resolution, magnification and window settings on contrast-detail detection.

    abstract::The aim of this study was to investigate the combined effects of liquid crystal display (LCD) resolution, image magnification and window/level adjustment on the low-contrast performance in soft-copy image interpretation in digital radiography and digital mammography. In addition, the effect of a new LCD noise reductio...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2005.12.016

    authors: Bacher K,Smeets P,De Hauwere A,Voet T,Duyck P,Verstraete K,Thierens H

    更新日期:2006-06-01 00:00:00

  • Time-resolved quantitative evaluation of diaphragmatic motion during forced breathing in a health screening cohort in a standing position: Dynamic chest phrenicography.

    abstract:OBJECTIVE:To assess diaphragmatic motion during forced breathing in a health screening center cohort by time-resolved quantitative analysis using dynamic chest radiography and demonstrate the characteristics and associations with demographics and pulmonary function of participants. MATERIALS AND METHODS:This prospecti...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2019.01.034

    authors: Hida T,Yamada Y,Ueyama M,Araki T,Nishino M,Kurosaki A,Jinzaki M,Honda H,Hatabu H,Kudoh S

    更新日期:2019-04-01 00:00:00

  • Imaging of the optic nerve.

    abstract::This article provides an overview of the imaging findings of diseases affecting the optic nerve with special emphasis on clinical-radiological correlation and on the latest technical developments in MR imaging and CT. The review deals with congenital malformations, tumors, toxic/nutritional and degenerative entities, ...

    journal_title:European journal of radiology

    pub_type: 杂志文章,评审

    doi:10.1016/j.ejrad.2009.09.029

    authors: Becker M,Masterson K,Delavelle J,Viallon M,Vargas MI,Becker CD

    更新日期:2010-05-01 00:00:00

  • Triage for suspected acute Pulmonary Embolism: Think before opening Pandora's Box.

    abstract::This is a review of the current strengths and weaknesses of the various imaging modalities available for the diagnosis of suspected non-massive Pulmonary Embolism (PE). Without careful consideration for the clinical presentation, and the timely application of clinical decision support (CDS) methodology, the current ov...

    journal_title:European journal of radiology

    pub_type: 杂志文章,评审

    doi:10.1016/j.ejrad.2015.03.023

    authors: Levin D,Seo JB,Kiely DG,Hatabu H,Gefter W,van Beek EJ,Schiebler ML,2013 International Workshop for Pulmonary Functional Imaging (IWPFI).

    更新日期:2015-06-01 00:00:00

  • Prediction of muscle invasion of bladder cancer: A comparison between DKI and conventional DWI.

    abstract:OBJECTIVES:To prospectively compare the diagnostic efficacy of conventional diffusion-weighted imaging (DWI) and diffusion kurtosis imaging (DKI) in differentiating between muscle-invasive bladder cancer (MIBC) and non-muscle-invasive bladder cancer (NMIBC). METHODS:Multiple b value DWIs were performed using a 3-T mag...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2021.109522

    authors: Li Q,Cao B,Tan Q,Liu K,Jiang S,Zhou J

    更新日期:2021-01-06 00:00:00

  • Sonographic diagnosis of intracranial hemorrhage and periventricular leukomalacia in premature African neonates.

    abstract::Transfontanelle ultrasound (US) was done prospectively and analyzed for intra-cranial hemorrhage (ICH) and periventricular leukomalacia (PVL) in 110 premature infants. The babies were divided into two subgroups according to their birth weights (BW): those with BW of 1500 g or less (n = 93) belonged to subgroup A while...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/s0720-048x(96)01151-5

    authors: Nzeh DA,Ajayi OA

    更新日期:1997-12-01 00:00:00

  • Computed tomography with intravenous cholangiography contrast: a method for visualizing choledochal cysts.

    abstract::Our patient presented with a typical case history and typical symptoms. She also belongs to a group with a high incidence of the disorder. The diagnosis was suspected at ultrasonography, which accurately detected the presence and location of a cyst, but could not establish its origin. Computed tomography is a better d...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/0720-048x(90)90128-x

    authors: Höglund M,Muren C,Boijsen MW

    更新日期:1990-03-01 00:00:00

  • The chemistry of iomeprol and physico-chemical properties of its aqueous solutions and pharmaceutical formulations.

    abstract::The synthesis and the chemical characterization of iomeprol, a new triiodinated nonionic radiographic contrast agent, are reported. The physico-chemical properties both of aqueous solutions of the pure compound and of its pharmaceutical formulations are presented and these last data are compared with those of other co...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/0720-048x(94)90089-2

    authors: Gallotti A,Uggeri F,Favilla A,Cabrini M,de Haën C

    更新日期:1994-05-01 00:00:00

  • Implementation of patient-tailored contrast volumes based on body surface area and heart rate harmonizes contrast enhancement and reduces contrast load in small patients in portal venous phase abdominal CT.

    abstract:PURPOSE:The aim of this study was to evaluate the impact of a patient-tailored contrast volume protocol on portal venous phase abdominal CT-images compared to a fixed volume protocol in daily radiological practice. METHOD:Data of 77 patients who underwent two contrast-enhanced CT-examinations were collected. The first...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2019.07.031

    authors: Walgraeve MS,Pyfferoen L,Van De Moortele K,Zanca F,Bielen D,Casselman JW

    更新日期:2019-12-01 00:00:00

  • Observer agreement in the reporting of knee and lumbar spine magnetic resonance (MR) imaging examinations: selectively trained MR radiographers and consultant radiologists compared with an index radiologist.

    abstract:PURPOSE:To assess agreement between trained radiographers and consultant radiologists compared with an index radiologist when reporting on magnetic resonance imaging (MRI) examinations of the knee and lumbar spine and to examine the subsequent effect of discordant reports on patient management and outcome. METHODS:At ...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2013.05.024

    authors: Brealey S,Piper K,King D,Bland M,Caddick J,Campbell P,Gibbon A,Highland A,Jenkins N,Petty D,Warren D

    更新日期:2013-10-01 00:00:00

  • Evaluation of hypervascular hepatocellular carcinoma in cirrhotic liver: comparison of different concentrations of contrast material with multi-detector row helical CT--a prospective randomized study.

    abstract:PURPOSE:To evaluate two different iodine concentrations of contrast material for detecting hypervascular hepatocellular carcinomas (HCCs) in cirrhotic liver by multi-detector row helical CT (MDCT) when a fixed contrast material volume and injection rate is used. MATERIALS AND METHODS:Institutional Review Board approva...

    journal_title:European journal of radiology

    pub_type: 杂志文章,随机对照试验

    doi:10.1016/j.ejrad.2010.10.006

    authors: Sofue K,Tsurusaki M,Kawasaki R,Fujii M,Sugimura K

    更新日期:2011-12-01 00:00:00

  • Clinically unrecognized pulmonary aspiration during gastrointestinal endoscopy with sedation: a potential pitfall interfering the performance of 18F-FDG PET for cancer screening.

    abstract:PURPOSE:We found several cases with unexpected pulmonary abnormalities on the 18F-FDG PET scan after the gastrointestinal endoscopy with sedation during a compact health check-up course, interfering the interpretations of 18F-FDG PET scan for cancer screening. The current studies aimed to analyze the incidence and the ...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2010.10.030

    authors: Hsieh TC,Wu YC,Ding HJ,Wang CH,Yen KY,Sun SS,Yeh JJ,Kao CH

    更新日期:2011-12-01 00:00:00

  • Accuracy and consequences of 3D-fluoroscopy in upper and lower extremity fracture treatment: a systematic review.

    abstract:OBJECTIVES:The aim of this systematic review was to compare the diagnostic accuracy, subjective image quality and clinical consequences of 3D-fluoroscopy with standard imaging modalities (2D-fluoroscopy, X-ray or CT) during reduction and fixation of intra-articular upper and lower extremity fractures. METHODS:A system...

    journal_title:European journal of radiology

    pub_type: 杂志文章,meta分析,评审

    doi:10.1016/j.ejrad.2012.06.021

    authors: Beerekamp MS,Sulkers GS,Ubbink DT,Maas M,Schep NW,Goslings JC

    更新日期:2012-12-01 00:00:00

  • Multi-section CT angiography compared with digital subtraction angiography in diagnosing major arterial hemorrhage in inflammatory pancreatic disease.

    abstract:PURPOSE:Major arterial hemorrhage is an uncommon but serious complication of pancreatitis with high morbidity and mortality. Digital subtraction angiography (DSA) has long been the gold standard for the detection of a visceral artery pseudoaneurysm or for the site of active bleeding in patients with pancreatitis. Multi...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2006.02.006

    authors: Hyare H,Desigan S,Nicholl H,Guiney MJ,Brookes JA,Lees WR

    更新日期:2006-08-01 00:00:00

  • Shadowing and reverberation artifacts in abdominal ultrasonography.

    abstract::The different features of 821 acoustic shadows recorded during abdominal US examinations were analysed to find out whether any of the features may be used in routine work to help to identify the often invisible structure casting the shadow. A constant shadow with closely spaced high level reverberation echoes is stron...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:

    authors: Suramo I,Päivänsalo M,Vuoria P

    更新日期:1985-05-01 00:00:00

  • Application of CT perfusion imaging to the histological differentiation of adrenal gland tumors.

    abstract:BACKGROUND:CT perfusion imaging has been used in diagnosis and classification of tumors widely and in assess tumor angiogenesis in some organs. However, there are few reports describing CT perfusion imaging of adrenal gland tumors. OBJECTIVE:This study aimed to evaluate the application of CT perfusion imaging in analy...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2010.12.072

    authors: Qin HY,Sun HR,Li YJ,Shen BZ

    更新日期:2012-03-01 00:00:00

  • Peripheral DSA with automated stepping.

    abstract::Peripheral digital angiography can be applied with automated stepping and in digital subtracted technique to evaluate the complete lower extremities angiographically with one single injection of contrast medium. Altogether 25 DSA-examinations were compared with non-substracted technique. By DSA-technique additional se...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/0720-048x(91)90056-2

    authors: Fink U,Heywang SH,Hilbertz T,Fischer K,Jenner E,Buchsteiner W

    更新日期:1991-07-01 00:00:00

  • T2 mapping in patellar chondromalacia.

    abstract:OBJECTIVE:To study the correlation between the T2 relaxation times of the patellar cartilage and morphological MRI findings of chondromalacia. METHODS:This prospective study comprises 50 patients, 27 men and 23 women suffering of anterior knee pain (mean age: 29.7, SD 8.3 years; range: 16-45 years). MRI of 97 knees we...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2014.03.007

    authors: Ruiz Santiago F,Pozuelo Calvo R,Almansa López J,Guzmán Álvarez L,Castellano García MDM

    更新日期:2014-06-01 00:00:00

  • Diagnostic ultrasound equipment. Safety and dosimetry.

    abstract::A survey of present opinions on the safety of diagnostic ultrasound applications is presented together with some data on output levels. Physical mechanisms involved in potential adverse effects are described. Labelling requirements of the equipment are defined and specified. These requirements are contained in a recen...

    journal_title:European journal of radiology

    pub_type: 杂志文章,评审

    doi:

    authors: Thijssen JM,van Beekum WT,Daniëls O,Koch CW,Lanćee CT,Somer JC,de Vlieger M,Wladimiroff JW

    更新日期:1989-02-01 00:00:00

  • Predictive value of small ulcers in the evolution of acute type B intramural hematoma.

    abstract:OBJECTIVE:To assess the long-term evolution and predictive factors of type B intramural hematoma (IMH). MATERIAL AND METHODS:34 patients (33 men), mean age: 67 years (47-87) diagnosed with type B IMH by computed tomography (CT) and followed up clinically and by CT yearly. Mean follow-up was 5.9 years (2-13 years). Two...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2011.04.055

    authors: Sebastià C,Evangelista A,Quiroga S,Cuellar H,Aguilar R,Muntanyà X

    更新日期:2012-07-01 00:00:00

  • Multiphase CT scanning and different intravenous contrast media concentrations in combined F-18-FDG PET/CT: Effect on quantitative and clinical assessment.

    abstract:PURPOSE:To evaluate the influence of multiphase CT scanning and different intravenous contrast media on contrast enhancement, attenuation correction and image quality in combined PET/CT. MATERIAL AND METHODS:140 patients were prospectively enrolled for F-18-FDG-PET/CT including a low-dose unenhanced, arterial and veno...

    journal_title:European journal of radiology

    pub_type: 杂志文章,随机对照试验

    doi:10.1016/j.ejrad.2012.04.007

    authors: Rebière M,Verburg FA,Palmowski M,Krohn T,Pietsch H,Kuhl CK,Mottaghy FM,Behrendt FF

    更新日期:2012-08-01 00:00:00

  • Treatment failure after uterine artery embolization: prospective cohort study with multifactorial analysis of possible predictors of long-term outcome.

    abstract:PURPOSE:To evaluate the impact of baseline characteristics and residual leiomyoma perfusion after uterine artery embolization (UAE) on clinical long-term outcome. MATERIALS AND METHODS:One hundred fifteen patients underwent UAE. All patients were divided into three groups according to achieved infarction rate determin...

    journal_title:European journal of radiology

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.ejrad.2012.01.031

    authors: Scheurig-Muenkler C,Koesters C,Grieser C,Hamm B,Kroencke TJ

    更新日期:2012-05-01 00:00:00