Abstract:
:Peripheral digital angiography can be applied with automated stepping and in digital subtracted technique to evaluate the complete lower extremities angiographically with one single injection of contrast medium. Altogether 25 DSA-examinations were compared with non-substracted technique. By DSA-technique additional series could be reduced to only those, where significantly different flow in both extremities necessitated different timing as known from conventional angiography. DSA-technique with automated stepping may in the future totally replace conventional angiography of the peripheral arteries.
journal_name
Eur J Radioljournal_title
European journal of radiologyauthors
Fink U,Heywang SH,Hilbertz T,Fischer K,Jenner E,Buchsteiner Wdoi
10.1016/0720-048x(91)90056-2subject
Has Abstractpub_date
1991-07-01 00:00:00pages
50-4issue
1eissn
0720-048Xissn
1872-7727pii
0720-048X(91)90056-2journal_volume
13pub_type
杂志文章abstract:OBJECTIVE:To investigate dynamic susceptibility contrast (DSC) perfusion weighted imaging (PWI) in white matter lesions (WML) in patients with multiple sclerosis (MS), using automatically generated binary masks of brain tissue. BACKGROUND:WML in MS have in some studies demonstrated perfusion abnormalities compared to ...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2015.09.007
更新日期:2015-12-01 00:00:00
abstract:OBJECTIVE:Tissue Factor (TF) has been well established in angiogenesis, invasion, metastasis, and prognosis in glioma. A noninvasive assessment of TF expression status in glioma is therefore of obvious clinical relevance. Dynamic contrast-enhanced (DCE) MRI parameters have been used to evaluate microvascular characteri...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2017.06.006
更新日期:2017-08-01 00:00:00
abstract:OBJECTIVE:Although whole-body fluorine-18 fluorodeoxyglucose (18F-FDG) positron emission tomography (PET)/computed tomography (CT) (18F-FDG PET/CT) is commonly used for M staging of newly diagnosed nasopharyngeal carcinoma (NPC), some patients may not benefit from this procedure. The present study investigated which pa...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2017.02.002
更新日期:2017-04-01 00:00:00
abstract:PURPOSE:To evaluate the speed and precision of split renal volume (SRV) measurement, which is the ratio of unilateral renal volume to bilateral renal volume, using a newly developed software for computed tomographic (CT) volumetry and to investigate the usefulness of SRV for the estimation of split renal function (SRF)...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2009.11.013
更新日期:2011-07-01 00:00:00
abstract::HSP70 promoter-driven gene therapy and inhibition of HSP90 activity with small molecule inhibitors are two shining points in a newly developed cohort of cancer treatment. For HSP70 promoters, high efficiency and heat inducibility within a localized region make it very attractive to clinical translation. The HSP90 inhi...
journal_title:European journal of radiology
pub_type: 杂志文章,评审
doi:10.1016/j.ejrad.2009.01.052
更新日期:2009-05-01 00:00:00
abstract::The relative contrast enhancement of normal myometrium and small or medium size uterine fibroids and clinical stage I endometrial carcinomas were correlated to their microangiographically demonstrable vascularity. In four cases small uterine fibroids showed contrast enhancement equal to normal myometrium, independent ...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:
更新日期:1984-05-01 00:00:00
abstract:PURPOSE:MR staging of nodal metastases in patients with rectal cancer using criteria based on size, shape and signal intensity can be difficult, because > or =50% of the nodes are less than 5 mm in size. Therefore new MR criteria were evaluated to see whether it can improve the MR assessment of nodal metastases in rect...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2003.12.005
更新日期:2004-10-01 00:00:00
abstract::A simplified and rapid method for making radiographic slides or prints using a personal computer, a computer monitor adapter and a laser imager is described. When the divided monitor output of a personal computer is connected to a laser imager in the Radiology Department, radiographs and text on the personal computer ...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/0720-048x(96)01061-3
更新日期:1996-09-01 00:00:00
abstract:OBJECTIVE:To assess the effect of breast density, fibroglandular tissue volume, and breast volume on the rate of false-positive marks of a computer-assisted detection software in digital mammography. MATERIALS AND METHODS:222 patients with normal digital mammograms and a minimum follow-up of 22 months were retrospecti...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2012.02.017
更新日期:2012-08-01 00:00:00
abstract:AIM:The objective of this study is to evaluate the efficacy and safety of image-guided percutaneous splenic interventions as diagnostic or therapeutic procedures. MATERIALS AND METHODS:We performed a retrospective review of our interventional records from July 2001 to June 2006. Ninety-five image-guided percutaneous s...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2007.02.011
更新日期:2007-10-01 00:00:00
abstract::Degenerative and overuse diseases as well as impingement syndromes of the hand are illustrated and discussed in this review article. Osteoarthritis of the interphalangeal joints as described by Heberden and Bouchard is a ubiquitous articular disease often associated with synovitis and erosive joint destruction. Osteoa...
journal_title:European journal of radiology
pub_type: 杂志文章,评审
doi:10.1016/s0720-048x(97)00047-8
更新日期:1997-09-01 00:00:00
abstract:OBJECTIVE:The objective of this study was to establish the cut-off value of the signal intensity drop on chemical shift magnetic resonance imaging (MRI) with appropriate sensitivity and specificity to differentiate osteoporotic from neoplastic wedging of the spine. PATIENTS AND METHODS:All patients with wedging of ver...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2008.06.019
更新日期:2009-10-01 00:00:00
abstract:PURPOSE:Lung perfusion analysis at dual energy CT (DECT) is sensitive to beam hardening artifacts from dense contrast material (CM). We compared two scan and four CM injection protocols in terms of severity of artifacts and attenuation levels in the thoracic vessels. METHODS AND MATERIALS:Data of 120 patients who had ...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2010.09.030
更新日期:2011-12-01 00:00:00
abstract::The aim of this prospective study was to assess the accuracy of modern ultrasonography in diagnostic imaging of meniscal tears. One hundred and sixty menisci were evaluated in 80 patients (42 females, 38 males, mean age=36.2 years, range=16-70 years). Inclusion criteria for the study were twofold: clinical suspicion o...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2011.09.013
更新日期:2012-09-01 00:00:00
abstract::Maple Syrup Urine Disease (MSUD) is an inherited metabolic disorder characterized by a severe, usually lethal, neonatal course in the early stages with pseudotumor cerebri and pathologically documented increased cerebral water content. CT and MRI studies in MSUD are few and the data are overlapping. This study reports...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/0720-048x(92)90089-r
更新日期:1992-05-01 00:00:00
abstract:OBJECTIVE:To verify the clinical outcomes of applying water swallowing to MR esophagography. METHODS:Thirty patients confirmed postoperatively or histopathologically with thoracic esophageal carcinoma by endoscopic biopsy and 10 healthy volunteers with normal esophagus underwent respectively conventional magnetic reso...
journal_title:European journal of radiology
pub_type: 杂志文章,随机对照试验
doi:10.1016/j.ejrad.2011.05.010
更新日期:2012-09-01 00:00:00
abstract:OBJECTIVES:Structural and functional changes in pulmonary vessels are prevalent at the initial stages of chronic obstructive pulmonary disease (COPD). These vascular alterations can be assessed using cross-sectional area (CSA) of small pulmonary vessels. However, neither in non-COPD smokers nor in COPD patients it has ...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2013.05.022
更新日期:2013-10-01 00:00:00
abstract:OBJECTIVE:We investigated whether the prerequisite of the maximum slope and deconvolution methods are satisfied in pancreatic perfusion CT and whether the measured parameters between these algorithms are correlated. METHODS:We examined nine beagles injected with iohexol (200 mgI kg(-1)) at 5.0 ml s(-1). The abdominal ...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2009.06.016
更新日期:2011-01-01 00:00:00
abstract:AIM:The aim of the present study was to investigate the diagnostic and prognostic value of combined (18)F-2-fluorodeoxyglucose positron emission tomography and contrast enhanced X-ray computed tomography (FDG-PET/CT) in women with a suspicion of recurrent ovarian cancer. PATIENTS AND METHODS:We retrospectively reviewe...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2013.12.006
更新日期:2014-03-01 00:00:00
abstract:OBJECTIVES:To investigate the feasibility of implementing quantitative T1-perfusion in the routine MRA-protocol and to obtain a first experience in normals and pathology. MATERIALS AND METHODS:For perfusion imaging, IR-prepared FLASH (one 4 mm slice at mid-renal level, TR 4.4 ms, TE 2.2 ms, TI 180 ms, FA 50 degrees , ...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2007.11.033
更新日期:2009-03-01 00:00:00
abstract::Renal venous DSA yields diagnostically adequate results in an unselected population in more than 85% of cases. Image quality is compromised predominantly by inadequate contrast enhancement, motion artifacts from the stomach and the bowel, and obesity. The effect of these factors increases with patient age. Selection o...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:
更新日期:1986-11-01 00:00:00
abstract:INTRODUCTION:Accuracy of locoregional staging in patients with oesophageal cancer is critical in determining operability and the need for neoadjuvant treatment. Imaging technology has advanced significantly in recent years but it is not known whether this translates to improved staging accuracy. This study investigates...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2017.10.015
更新日期:2017-12-01 00:00:00
abstract:OBJECTIVE:To obtain T2* and proton density measurements of normal human lung parenchyma in vivo using submillisecond echo time (TE) gradient echo (GRE) magnetic resonance (MR) imaging. MATERIALS AND METHODS:Six normal volunteers were scanned using a 1.5-T system equipped with a prototype enhanced gradient (GE Signa, W...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/s0720-048x(98)00169-7
更新日期:1999-03-01 00:00:00
abstract:PURPOSE:To describe the internal pudendal artery (IPA) and accessory pudendal artery (APA) detected by magnetic resonance (MR) angiography to help surgeons to find and preserve them during radical prostatectomy (RP). MATERIALS AND METHODS:Constrast-enhanced MR 3.0 T angiography of the pelvis were performed in 111 male...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2015.01.017
更新日期:2015-05-01 00:00:00
abstract:INTRODUCTION:The purpose of this study was to determine the increase in diaphragmatic excursion of patients with chronic obstructive pulmonary disease (COPD) treated with theophylline by MR-fluoroscopy which is an innovative method to demonstrate effectiveness of this treatment. MATERIALS AND METHODS:Investigations we...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/S0720-048X(03)00210-9
更新日期:2004-08-01 00:00:00
abstract:PURPOSE:Human metapneumovirus has been increasingly identified as a cause of lower respiratory tract infection in adults worldwide. The CT imaging features of human metapneumovirus in adults have not been characterized. The purpose of this paper is to determine the imaging features of human metapneumovirus and to compa...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2020.108988
更新日期:2020-07-01 00:00:00
abstract::Two principally different 1000-line CRT (cathode ray tube) monitors connected to a digital image intensifier system for chest radiography were compared in terms of image quality and viewing comfort. Image quality was assessed by means of ROC analysis. Five observers tried to find simulated pathology positioned over th...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/0720-048x(96)00750-4
更新日期:1996-06-01 00:00:00
abstract:OBJECTIVE:Hypothyroidism is a common complication in patients receiving tyrosine kinase inhibitors. We evaluated the relationship between thyroid size evident on CT and thyroid function in patients with advanced renal cell carcinoma (RCC) receiving tyrosine kinase inhibitors. MATERIALS AND METHODS:Forty-two patients w...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2011.06.035
更新日期:2012-09-01 00:00:00
abstract:PURPOSE:To determine the prevalence and characterise the significance of incidental findings on whole-body MRI in paediatric and adult populations. METHODS:A retrospective, single-institution study over a period of 8 years. The study population comprised 325 paediatric (0-18 yrs) patients and 148 adults (19-40 yrs) re...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2020.109156
更新日期:2020-09-01 00:00:00
abstract:PURPOSE:To compare diagnostic capability of preoperative N-staging of lung cancer between thin-section CT of the mediastinum and FDG PET, and 5mm slice thickness CT. MATERIALS AND METHODS:The subjects were 34 patients with lung carcinoma who were examined by both CT and PET, and subsequently underwent surgery between ...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2009.01.021
更新日期:2010-03-01 00:00:00