Relationship between contact force sensing technology and medium-term outcome of atrial fibrillation ablation: a multicenter study of 600 patients.

Abstract:

INTRODUCTION:Contact force sensing (CFS) technology improves acute pulmonary vein isolation durability; however, its impact on the clinical outcome of ablating atrial fibrillation (AF) is unknown. METHODS AND RESULTS:First time AF ablation procedures employing CFS from 4 centers were matched retrospectively to those without CFS in a 1:2 manner by type of AF. Freedom from atrial tachyarrhythmia was defined as the primary outcome measure, and fluoroscopy time the secondary outcome measure. Nineteen possible explanatory variables were tested in addition to CFS. A total of 600 AF ablation procedures (200 using CFS and 400 using non-CFS catheters) performed between 2010 and 2012 (46% paroxysmal, 36% persistent, 18% long-lasting persistent) were analyzed. The mean follow-up duration was 11.4 ± 4.7 months-paroxysmal AF 11.2 ± 4.1 CFS versus 11.3 ± 3.9 non-CFS (P = 0.745)-nonparoxysmal AF 10.4 ± 4.5 CFS versus 11.9 ± 5.4 non-CFS (P = 0.015). The use of a CFS catheter independently predicted clinical success in ablating paroxysmal AF (HR 2.24 [95% CIs 1.29-3.90]; P = 0.004), but not nonparoxysmal AF (HR 0.73 [0.41-1.30]; P = 0.289) in a multivariate analysis that included follow-up duration. Among all cases, the use of CFS catheters was associated with reduced fluoroscopy time in multivariate analysis (reduction by 7.7 [5.0-10.5] minutes; P < 0.001). Complication rates were similar in both groups. CONCLUSIONS:At medium-term follow-up, CFS catheter technology is associated with significantly improved outcome of first time catheter ablation of paroxysmal AF, but not nonparoxysmal AF. Fluoroscopy time was lower when CFS technology was employed in all types of AF ablation procedures.

authors

Jarman JWE,Panikker S,DAS M,Wynn GJ,Ullah W,Kontogeorgis A,Haldar SK,Patel PJ,Hussain W,Markides V,Gupta D,Schilling RJ,Wong T

doi

10.1111/jce.12606

subject

Has Abstract

pub_date

2015-04-01 00:00:00

pages

378-384

issue

4

eissn

1045-3873

issn

1540-8167

journal_volume

26

pub_type

杂志文章,多中心研究
  • Atrial fibrillation and congestive heart failure: specific considerations at the intersection of two common and important cardiac disease sets.

    abstract::Atrial fibrillation (AF) and congestive heart failure (CHF) are two increasingly common cardiac disorders with a growing prevalence in the overall population. Improved treatment of acute medical conditions has increased the incidence of these cardiac disorders. AF and CHF have similar epidemiologic characteristics and...

    journal_title:Journal of cardiovascular electrophysiology

    pub_type: 杂志文章,评审

    doi:10.1046/j.1540-8167.2002.00399.x

    authors: Ehrlich JR,Nattel S,Hohnloser SH

    更新日期:2002-04-01 00:00:00

  • Atrioventricular node ablation and permanent ventricular pacemaker implantation without fluoroscopy: use of an electroanatomic navigation system.

    abstract::Non-fluoroscopy AV ablation and pacemaker implantation. Fluoroscopic guidance is the standard tool used for transvenous pacemaker implantations and for electrophysiological and ablation procedures. It implies X-ray exposure, occasionally with high dose of radiation for the patient and operator. We describe the case of...

    journal_title:Journal of cardiovascular electrophysiology

    pub_type: 杂志文章

    doi:10.1046/j.1540-8167.2005.40774.x

    authors: Ruiz-Granell R,Morell-Cabedo S,Ferrero-De-Loma A,García-Civera R

    更新日期:2005-07-01 00:00:00

  • Reversal of deteriorated fractal behavior of heart rate variability by beta-blocker therapy in patients with advanced congestive heart failure.

    abstract:INTRODUCTION:The slope of the power spectrum in heart rate variability (HRV) reflects the fractal or scaling behavior in HR dynamics and recently was confirmed as an independent predictor of postmyocardial infarction survival. Whether or not the new measurement in HRV foresees the functional evolution in patients with ...

    journal_title:Journal of cardiovascular electrophysiology

    pub_type: 杂志文章

    doi:10.1046/j.1540-8167.2001.00026.x

    authors: Lin LY,Lin JL,Du CC,Lai LP,Tseng YZ,Huang SK

    更新日期:2001-01-01 00:00:00

  • Electrophysiological Characteristics, Rhythm, Disturbances and Conduction Discontinuities Under Autonomic Stimulation in the Rat Pulmonary Vein Myocardium.

    abstract:INTRODUCTION:Despite the importance of neurogenic initiation of rapid firing from pulmonary veins (PVs), the mechanism of autonomic modulation of electrophysiological properties of the PV myocardium to form a substrate for atrial arrhythmia remains poorly understood. METHODS AND RESULTS:A 2-microelectrode technique wa...

    journal_title:Journal of cardiovascular electrophysiology

    pub_type: 杂志文章

    doi:10.1111/jce.12738

    authors: Egorov YV,Kuz'min VS,Glukhov AV,Rosenshtraukh LV

    更新日期:2015-10-01 00:00:00

  • Fibrillation is more complex in the left ventricle than in the right ventricle.

    abstract:INTRODUCTION:The mechanisms that maintain ventricular fibrillation (VF) are not completely understood. It has been proposed that increased ventricular wall thickness destabilizes VF wavefronts and therefore is an important determinant of VF activation patterns. We hypothesized that if this is the case, then VF patterns...

    journal_title:Journal of cardiovascular electrophysiology

    pub_type: 杂志文章

    doi:10.1046/j.1540-8167.2000.01364.x

    authors: Rogers JM,Huang J,Pedoto RW,Walker RG,Smith WM,Ideker RE

    更新日期:2000-12-01 00:00:00

  • High-power short-duration versus standard radiofrequency ablation: Insights on lesion metrics.

    abstract:INTRODUCTION:Radiofrequency (RF) lesion metrics are influenced by underlying parameters like RF power, duration, and contact force (CF), and utilization of lesion metric indices (ablation index [AI]) is a proposed strategy to predict lesion quality. The aim of this study was to analyze the influence of underlying param...

    journal_title:Journal of cardiovascular electrophysiology

    pub_type: 杂志文章

    doi:10.1111/jce.13724

    authors: Bourier F,Duchateau J,Vlachos K,Lam A,Martin CA,Takigawa M,Kitamura T,Frontera A,Cheniti G,Pambrun T,Klotz N,Denis A,Derval N,Cochet H,Sacher F,Hocini M,Haïssaguerre M,Jais P

    更新日期:2018-11-01 00:00:00

  • Safety and efficacy of catheter ablation for atrial fibrillation in abdominal solid organ (renal and hepatic) transplant recipients: A single-center pilot experience.

    abstract:BACKGROUND:Atrial fibrillation (AF) is common in abdominal solid organ transplant recipients and a cause of morbidity and mortality in this population. However, the outcomes of catheter ablation (CA) in transplant recipients with AF remain unclear. This study aimed to elucidate the outcomes of CA in renal and hepatic t...

    journal_title:Journal of cardiovascular electrophysiology

    pub_type: 杂志文章

    doi:10.1111/jce.14775

    authors: Su X,Zhao X,Long DY,Sang CH,Yu RH,Tang RB,Bai R,Liu N,Jiang CX,Li SN,Guo XY,Wang W,Hu R,Du X,Dong JZ,Ma CS

    更新日期:2020-12-01 00:00:00

  • Ibutilide-induced cardioversion of atrial fibrillation during pregnancy.

    abstract::We present two cases of successful cardioversion of atrial fibrillation using intravenous ibutilide during pregnancy. One patient had atrial fibrillation, complicating the Wolff-Parkinson-White syndrome and the other had a history of nonobstructive hypertrophic cardiomyopathy. No adverse maternal or fetal effects were...

    journal_title:Journal of cardiovascular electrophysiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8167.2006.00752.x

    authors: Kockova R,Kocka V,Kiernan T,Fahy GJ

    更新日期:2007-05-01 00:00:00

  • Regional isolation in the right atrium with disruption of intra-atrial conduction after catheter ablation of atrial tachycardia.

    abstract:BACKGROUND:Ablation of atrial tachycardia (AT) that occurs after cardiac surgery or prior ablation often requires complex lesion sets. In combination with the pre-existing atrial scar, these lesion sets may result in inadvertent intra-atrial conduction block. This study reports the phenomenon of incidental isolation of...

    journal_title:Journal of cardiovascular electrophysiology

    pub_type: 杂志文章

    doi:10.1111/jce.14037

    authors: Markowitz SM,Choi DY,Daian F,Liu CF,Cheung JW,Thomas G,Ip JE,Lerman BB

    更新日期:2019-10-01 00:00:00

  • Catheter ablation for hemodynamically unstable monomorphic ventricular tachycardia.

    abstract:INTRODUCTION:Hemodynamic collapse precludes extensive catheter mapping to identify focal target regions in many patients with ventricular tachycardia (VT) associated with heart disease. This study tested the feasibility of catheter ablation of poorly tolerated VTs by targeting a region identified during sinus rhythm. ...

    journal_title:Journal of cardiovascular electrophysiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8167.2000.tb00734.x

    authors: Ellison KE,Stevenson WG,Sweeney MO,Lefroy DC,Delacretaz E,Friedman PL

    更新日期:2000-01-01 00:00:00

  • A novel toolkit to improve percutaneous subxiphoid needle access to the healthy pericardial sac.

    abstract:INTRODUCTION:The current practice of percutaneous subxiphoid needle access to the "healthy" pericardial sac has significant limitations. We sought to examine the feasibility of a novel toolkit designed to improve this procedure. METHODS AND RESULTS:The toolkit included a pericardial access needle and a virtual imaging...

    journal_title:Journal of cardiovascular electrophysiology

    pub_type: 杂志文章

    doi:10.1111/jce.12643

    authors: Ludwig DR,Menon PG,Fill B,Gartner M,Schwartzman D

    更新日期:2015-05-01 00:00:00

  • Conduction properties of the inferior vena cava-tricuspid annular isthmus in patients with typical atrial flutter.

    abstract:INTRODUCTION:A functional region of slow conduction located in the inferior right atrium has been postulated to be critical to the induction and maintenance of typical human atrial flutter. We reexamined the potential role of functional conduction delay in the annular isthmus between the tricuspid valve and the inferio...

    journal_title:Journal of cardiovascular electrophysiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8167.1997.tb00831.x

    authors: Kinder C,Kall J,Kopp D,Rubenstein D,Burke M,Wilber D

    更新日期:1997-07-01 00:00:00

  • Temporary esophageal stenting allows healing of esophageal perforations following atrial fibrillation ablation procedures.

    abstract:BACKGROUND:Left atrial catheter ablation (LACA) has emerged as a successful method to eliminate atrial fibrillation (AF). Recent reports have described atrio-esophageal fistulas, often resulting in death, from this procedure. Temporary esophageal stenting is an established therapy for malignant esophageal disease. We d...

    journal_title:Journal of cardiovascular electrophysiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8167.2006.00464.x

    authors: Bunch TJ,Nelson J,Foley T,Allison S,Crandall BG,Osborn JS,Weiss JP,Anderson JL,Nielsen P,Anderson L,Lappe DL,Day JD

    更新日期:2006-04-01 00:00:00

  • Is there a potential benefit to increased irrigation channels during radiofrequency ablation? Results from a two-center prospective randomized study.

    abstract:INTRODUCTION:Open irrigation during radiofrequency (RF) application allows a higher power delivery in the setting of temperature-controlled ablation, without causing blood clots. This study sought to evaluate the clinical value of the additional 6 supplementary channels at the proximal catheter tip compared to a standa...

    journal_title:Journal of cardiovascular electrophysiology

    pub_type: 杂志文章,多中心研究,随机对照试验

    doi:10.1111/j.1540-8167.2010.01945.x

    authors: Knecht S,Sacher F,Forclaz A,Verbeet T,Hocini M,Wright M,Tran-Ngoc E,Morissens M,Peperstraete B,Derval N,Jaïs P,Linton N,Decoodt P,Haïssaguerre M,Castro-Rodriguez J

    更新日期:2011-05-01 00:00:00

  • Future ablation concepts of tachyarrhythmias.

    abstract::Application of radiofrequency energy to arrhythmogenic substrates after careful cardiac mapping could ensure a high success rate in eliminating certain types of tachyarrhythmias. Future studies of catheter ablation will focus on how to improve ablation efficacy and achieve a better result in various types of tachyarrh...

    journal_title:Journal of cardiovascular electrophysiology

    pub_type: 杂志文章,评审

    doi:10.1111/j.1540-8167.1995.tb00360.x

    authors: Chen SA,Chiang CE,Tai CT,Lee SH,Chang MS

    更新日期:1995-10-01 00:00:00

  • Rate-control drugs affect variability and irregularity measures of RR intervals in patients with permanent atrial fibrillation.

    abstract:INTRODUCTION:Irregularity measures have been suggested as risk indicators in patients with atrial fibrillation (AF); however, it is not known to what extent they are affected by commonly used rate-control drugs. We aimed at evaluating the effect of metoprolol, carvedilol, diltiazem, and verapamil on the variability and...

    journal_title:Journal of cardiovascular electrophysiology

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/jce.12580

    authors: Corino VD,Ulimoen SR,Enger S,Mainardi LT,Tveit A,Platonov PG

    更新日期:2015-02-01 00:00:00

  • "A Song of Ice and Fire"-another verse from the world of ablation.

    abstract::The debate between the use of radiofrequency (RF) or cryoenergy for ablation near the atrioventricular (AV) conducting system or small coronaries has been fueled by the relative efficacies and risks of the two technologies, particularly in smaller hearts. The manuscript by Schneider et al adds another chapter to that ...

    journal_title:Journal of cardiovascular electrophysiology

    pub_type: 评论,社论

    doi:10.1111/jce.13987

    authors: Saul JP,LaPage MJ

    更新日期:2019-07-01 00:00:00

  • Idiopathic left ventricular tachycardia with left and right bundle branch block configurations.

    abstract:INTRODUCTION:Idiopathic left ventricular tachycardia typically has a right bundle branch block configuration. The purpose of this case report is to demonstrate that idiopathic ventricular tachycardia arising in or near the left posterior fascicle also may have a left bundle branch block configuration. METHODS AND RESU...

    journal_title:Journal of cardiovascular electrophysiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8167.1997.tb00810.x

    authors: Zivin A,Goyal R,Daoud E,Man KC,Strickberger SA,Morady F

    更新日期:1997-04-01 00:00:00

  • Role of residual potentials inside circumferential pulmonary veins ablation lines in the recurrence of paroxysmal atrial fibrillation.

    abstract:BACKGROUND:Residual gaps due to incomplete ablation lines are known to be the most common cause of recurrent atrial fibrillation (AF) after catheter ablation. We hypothesized that any residual potentials at the junction of the left atrium and pulmonary vein (PV), inside the circumferential PV ablation (CPVA) lines, wou...

    journal_title:Journal of cardiovascular electrophysiology

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/j.1540-8167.2010.01748.x

    authors: Kim YH,Lim HE,Pak HN,Kwak JJ,Park JS,Choi JI,Park SW,Kim YH

    更新日期:2010-09-01 00:00:00

  • First interventional exchange of a left transvenous phrenic nerve stimulation lead from the novel remedē system.

    abstract::The remedē system is a novel fully implantable transvenous phrenic nerve stimulation (TPNS) device developed to treat central sleep apnea. No information is published on how to explant or replace its leads. An eighty-one year-old had a fractured lead and we removed it over a wire. However, unbreachable resistances occ...

    journal_title:Journal of cardiovascular electrophysiology

    pub_type:

    doi:10.1111/jce.14725

    authors: Gutleben KJ,Eitz T,Westlund R,Gummert JF,Sommer P,Fox H

    更新日期:2020-11-01 00:00:00

  • Atrial structure and function 5 years after successful ablation for persistent atrial fibrillation: an MRI study.

    abstract:INTRODUCTION:The atrial outcome after extensive ablation is unknown. We sought to quantify atrial structure and function years after successful ablation for persistent atrial fibrillation (PsAF). METHODS AND RESULTS:We studied after 80 ± 15 months 26 patients (54 ± 8 years, 1 woman) with PsAF successfully treated by a...

    journal_title:Journal of cardiovascular electrophysiology

    pub_type: 杂志文章

    doi:10.1111/jce.12449

    authors: Cochet H,Scherr D,Zellerhoff S,Sacher F,Derval N,Denis A,Knecht S,Komatsu Y,Montaudon M,Laurent F,Pieske BM,Hocini M,Haïssaguerre M,Jaïs P

    更新日期:2014-07-01 00:00:00

  • Left atrial fibrillation with regular right atrial activation and a single left-to-right electrical interatrial connection: multisite mapping of dissimilar atrial rhythms.

    abstract::We report two patients who had isolated atrial fibrillation in the left atrium and regular activation of the entire right atrium. Mapping of the arrhythmia was performed using a 64-electrode basket catheter that was inserted intravenously and deployed in the right and left atria. Both patients manifested a single, sta...

    journal_title:Journal of cardiovascular electrophysiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8167.2000.tb00014.x

    authors: Ndrepepa G,Zrenner B,Schreieck J,Karch MR,Schneider MA,Schömig A,Schmitt C

    更新日期:2000-05-01 00:00:00

  • The seventh annual Gordon K. Moe Lecture. Atrial fibrillation: from cell t bedside.

    abstract::Atrial fibrillation is the most common sustained tachyarrhythmia and, as such, has become the recent focus of intense clinical and experimental interest. Because of its associated morbidity and mortality, there is a multidisciplinary effort to understand the pathophysiology that may ultimately lead to improved therape...

    journal_title:Journal of cardiovascular electrophysiology

    pub_type: 杂志文章,评审

    doi:10.1111/j.1540-8167.1997.tb00855.x

    authors: Zipes DP

    更新日期:1997-08-01 00:00:00

  • Posttraumatic left ventricular tachycardia arising from the anterior papillary muscle in an otherwise healthy child.

    abstract::After being struck by a car at the age of 7, an otherwise healthy boy developed recalcitrant, albeit hemodynamically, well-tolerated ventricular tachycardia. An electrophysiological study with 3-dimensional electroanatomic mapping was performed under transesophageal echocardiographic guidance at 10 years of age. Nonau...

    journal_title:Journal of cardiovascular electrophysiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8167.2010.01928.x

    authors: Horduna I,Dubuc M,Rochon AG,Khairy P

    更新日期:2011-06-01 00:00:00

  • Predictors of outcome after catheter ablation of premature ventricular complexes.

    abstract:BACKGROUND:The purpose of this study was to assess how well acute procedural outcomes predict the clinical outcome of catheter ablation of premature ventricular complexes (PVCs). METHODS:A consecutive series of 50 patients (28 women, age: 51 ± 13 years) with frequent PVCs was referred for PVC ablation. Acute failure w...

    journal_title:Journal of cardiovascular electrophysiology

    pub_type: 杂志文章

    doi:10.1111/jce.12400

    authors: Baser K,Bas HD,Belardi D,Yokokawa M,Good E,Latchamsetty R,Morady F,Bogun F

    更新日期:2014-06-01 00:00:00

  • Determination of single cryoablation outcome within 30 to 60 seconds of freezing based on ice impedance.

    abstract:BACKGROUND:A direct indicator of effective pulmonary vein isolation (PVI) based on early ice formation is presently lacking. OBJECTIVE:The initial impedance rise within 30 to 60 seconds (sec) of single cryoablation relating to ice on the distal surface of the cryoballoon could; predict effective PVI with early termina...

    journal_title:Journal of cardiovascular electrophysiology

    pub_type: 杂志文章

    doi:10.1111/jce.14097

    authors: Avitall B,Lizama KS,Kalinski A,Coulombe N,Laske TG

    更新日期:2019-10-01 00:00:00

  • Sophisticated architecture is required for the sinoatrial node to perform its normal pacemaker function.

    abstract::The heart's pacemaker, the sinoatrial node, does not consist of a group of uniform sinoatrial node cells embedded in atrial muscle. Instead, it is a heterogeneous tissue with multiple cell types and a complex structure. Evidence suggests that from the periphery to the center of the sinoatrial node, there is a gradient...

    journal_title:Journal of cardiovascular electrophysiology

    pub_type: 杂志文章,评审

    doi:10.1046/j.1540-8167.2003.02307.x

    authors: Boyett MR,Dobrzynski H,Lancaster MK,Jones SA,Honjo H,Kodama I

    更新日期:2003-01-01 00:00:00

  • Pretreatment of BAPTA-AM suppresses the genesis of repetitive endocardial focal discharges and pacing-induced ventricular arrhythmia during global ischemia.

    abstract:INTRODUCTION:In isolated rabbit hearts, repetitive endocardial focal discharges (REFDs) were consistently observed during ventricular fibrillation (VF) with prolonged (>5 minutes) global ischemia (GI). We hypothesized that BAPTA-AM, a calcium chelator, can suppress these REFDs. METHODS AND RESULTS:Using a two-camera o...

    journal_title:Journal of cardiovascular electrophysiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8167.2011.02067.x

    authors: Wu TJ,Lin SF,Hsieh YC,Lin TC,Lin JC,Ting CT

    更新日期:2011-10-01 00:00:00

  • A prospective randomized comparison in humans of 90-mu F and 120-mu F biphasic pulse defibrillation using a unipolar defibrillation system.

    abstract:INTRODUCTION:Capacitance is known to influence defibrillation. Optimal biphasic waveform capacitance for transvenous unipolar defibrillation systems in man is currently being defined. In an effort to improve defibrillation efficacy, we examined the relative defibrillation efficacy of a 65% tilt biphasic pulse from a 90...

    journal_title:Journal of cardiovascular electrophysiology

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1111/j.1540-8167.1995.tb00387.x

    authors: Poole JE,Kudenchuk PJ,Dolack GL,Jones GK,Degroot P,Johnson G,Bardy GH

    更新日期:1995-12-01 00:00:00

  • Serial defibrillation lead impedance in patients with epicardial and nonthoracotomy lead systems.

    abstract:INTRODUCTION:The stability of implantable cardiac defibrillation lead impedance subsequent to implantation has not been reported and may have important clinical implications. The objective was to characterize the incidence and degree of impedance changes occurring after implantation of defibrillation lead systems. MET...

    journal_title:Journal of cardiovascular electrophysiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8167.1996.tb00577.x

    authors: Schwartzman D,Hull ML,Callans DJ,Gottlieb CD,Marchlinski FE

    更新日期:1996-08-01 00:00:00