Abstract:
INTRODUCTION:Contact force sensing (CFS) technology improves acute pulmonary vein isolation durability; however, its impact on the clinical outcome of ablating atrial fibrillation (AF) is unknown. METHODS AND RESULTS:First time AF ablation procedures employing CFS from 4 centers were matched retrospectively to those without CFS in a 1:2 manner by type of AF. Freedom from atrial tachyarrhythmia was defined as the primary outcome measure, and fluoroscopy time the secondary outcome measure. Nineteen possible explanatory variables were tested in addition to CFS. A total of 600 AF ablation procedures (200 using CFS and 400 using non-CFS catheters) performed between 2010 and 2012 (46% paroxysmal, 36% persistent, 18% long-lasting persistent) were analyzed. The mean follow-up duration was 11.4 ± 4.7 months-paroxysmal AF 11.2 ± 4.1 CFS versus 11.3 ± 3.9 non-CFS (P = 0.745)-nonparoxysmal AF 10.4 ± 4.5 CFS versus 11.9 ± 5.4 non-CFS (P = 0.015). The use of a CFS catheter independently predicted clinical success in ablating paroxysmal AF (HR 2.24 [95% CIs 1.29-3.90]; P = 0.004), but not nonparoxysmal AF (HR 0.73 [0.41-1.30]; P = 0.289) in a multivariate analysis that included follow-up duration. Among all cases, the use of CFS catheters was associated with reduced fluoroscopy time in multivariate analysis (reduction by 7.7 [5.0-10.5] minutes; P < 0.001). Complication rates were similar in both groups. CONCLUSIONS:At medium-term follow-up, CFS catheter technology is associated with significantly improved outcome of first time catheter ablation of paroxysmal AF, but not nonparoxysmal AF. Fluoroscopy time was lower when CFS technology was employed in all types of AF ablation procedures.
journal_name
J Cardiovasc Electrophysioljournal_title
Journal of cardiovascular electrophysiologyauthors
Jarman JWE,Panikker S,DAS M,Wynn GJ,Ullah W,Kontogeorgis A,Haldar SK,Patel PJ,Hussain W,Markides V,Gupta D,Schilling RJ,Wong Tdoi
10.1111/jce.12606subject
Has Abstractpub_date
2015-04-01 00:00:00pages
378-384issue
4eissn
1045-3873issn
1540-8167journal_volume
26pub_type
杂志文章,多中心研究abstract::Atrial fibrillation (AF) and congestive heart failure (CHF) are two increasingly common cardiac disorders with a growing prevalence in the overall population. Improved treatment of acute medical conditions has increased the incidence of these cardiac disorders. AF and CHF have similar epidemiologic characteristics and...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 杂志文章,评审
doi:10.1046/j.1540-8167.2002.00399.x
更新日期:2002-04-01 00:00:00
abstract::Non-fluoroscopy AV ablation and pacemaker implantation. Fluoroscopic guidance is the standard tool used for transvenous pacemaker implantations and for electrophysiological and ablation procedures. It implies X-ray exposure, occasionally with high dose of radiation for the patient and operator. We describe the case of...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 杂志文章
doi:10.1046/j.1540-8167.2005.40774.x
更新日期:2005-07-01 00:00:00
abstract:INTRODUCTION:The slope of the power spectrum in heart rate variability (HRV) reflects the fractal or scaling behavior in HR dynamics and recently was confirmed as an independent predictor of postmyocardial infarction survival. Whether or not the new measurement in HRV foresees the functional evolution in patients with ...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 杂志文章
doi:10.1046/j.1540-8167.2001.00026.x
更新日期:2001-01-01 00:00:00
abstract:INTRODUCTION:Despite the importance of neurogenic initiation of rapid firing from pulmonary veins (PVs), the mechanism of autonomic modulation of electrophysiological properties of the PV myocardium to form a substrate for atrial arrhythmia remains poorly understood. METHODS AND RESULTS:A 2-microelectrode technique wa...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 杂志文章
doi:10.1111/jce.12738
更新日期:2015-10-01 00:00:00
abstract:INTRODUCTION:The mechanisms that maintain ventricular fibrillation (VF) are not completely understood. It has been proposed that increased ventricular wall thickness destabilizes VF wavefronts and therefore is an important determinant of VF activation patterns. We hypothesized that if this is the case, then VF patterns...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 杂志文章
doi:10.1046/j.1540-8167.2000.01364.x
更新日期:2000-12-01 00:00:00
abstract:INTRODUCTION:Radiofrequency (RF) lesion metrics are influenced by underlying parameters like RF power, duration, and contact force (CF), and utilization of lesion metric indices (ablation index [AI]) is a proposed strategy to predict lesion quality. The aim of this study was to analyze the influence of underlying param...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 杂志文章
doi:10.1111/jce.13724
更新日期:2018-11-01 00:00:00
abstract:BACKGROUND:Atrial fibrillation (AF) is common in abdominal solid organ transplant recipients and a cause of morbidity and mortality in this population. However, the outcomes of catheter ablation (CA) in transplant recipients with AF remain unclear. This study aimed to elucidate the outcomes of CA in renal and hepatic t...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 杂志文章
doi:10.1111/jce.14775
更新日期:2020-12-01 00:00:00
abstract::We present two cases of successful cardioversion of atrial fibrillation using intravenous ibutilide during pregnancy. One patient had atrial fibrillation, complicating the Wolff-Parkinson-White syndrome and the other had a history of nonobstructive hypertrophic cardiomyopathy. No adverse maternal or fetal effects were...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 杂志文章
doi:10.1111/j.1540-8167.2006.00752.x
更新日期:2007-05-01 00:00:00
abstract:BACKGROUND:Ablation of atrial tachycardia (AT) that occurs after cardiac surgery or prior ablation often requires complex lesion sets. In combination with the pre-existing atrial scar, these lesion sets may result in inadvertent intra-atrial conduction block. This study reports the phenomenon of incidental isolation of...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 杂志文章
doi:10.1111/jce.14037
更新日期:2019-10-01 00:00:00
abstract:INTRODUCTION:Hemodynamic collapse precludes extensive catheter mapping to identify focal target regions in many patients with ventricular tachycardia (VT) associated with heart disease. This study tested the feasibility of catheter ablation of poorly tolerated VTs by targeting a region identified during sinus rhythm. ...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 杂志文章
doi:10.1111/j.1540-8167.2000.tb00734.x
更新日期:2000-01-01 00:00:00
abstract:INTRODUCTION:The current practice of percutaneous subxiphoid needle access to the "healthy" pericardial sac has significant limitations. We sought to examine the feasibility of a novel toolkit designed to improve this procedure. METHODS AND RESULTS:The toolkit included a pericardial access needle and a virtual imaging...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 杂志文章
doi:10.1111/jce.12643
更新日期:2015-05-01 00:00:00
abstract:INTRODUCTION:A functional region of slow conduction located in the inferior right atrium has been postulated to be critical to the induction and maintenance of typical human atrial flutter. We reexamined the potential role of functional conduction delay in the annular isthmus between the tricuspid valve and the inferio...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 杂志文章
doi:10.1111/j.1540-8167.1997.tb00831.x
更新日期:1997-07-01 00:00:00
abstract:BACKGROUND:Left atrial catheter ablation (LACA) has emerged as a successful method to eliminate atrial fibrillation (AF). Recent reports have described atrio-esophageal fistulas, often resulting in death, from this procedure. Temporary esophageal stenting is an established therapy for malignant esophageal disease. We d...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 杂志文章
doi:10.1111/j.1540-8167.2006.00464.x
更新日期:2006-04-01 00:00:00
abstract:INTRODUCTION:Open irrigation during radiofrequency (RF) application allows a higher power delivery in the setting of temperature-controlled ablation, without causing blood clots. This study sought to evaluate the clinical value of the additional 6 supplementary channels at the proximal catheter tip compared to a standa...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 杂志文章,多中心研究,随机对照试验
doi:10.1111/j.1540-8167.2010.01945.x
更新日期:2011-05-01 00:00:00
abstract::Application of radiofrequency energy to arrhythmogenic substrates after careful cardiac mapping could ensure a high success rate in eliminating certain types of tachyarrhythmias. Future studies of catheter ablation will focus on how to improve ablation efficacy and achieve a better result in various types of tachyarrh...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 杂志文章,评审
doi:10.1111/j.1540-8167.1995.tb00360.x
更新日期:1995-10-01 00:00:00
abstract:INTRODUCTION:Irregularity measures have been suggested as risk indicators in patients with atrial fibrillation (AF); however, it is not known to what extent they are affected by commonly used rate-control drugs. We aimed at evaluating the effect of metoprolol, carvedilol, diltiazem, and verapamil on the variability and...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 杂志文章,随机对照试验
doi:10.1111/jce.12580
更新日期:2015-02-01 00:00:00
abstract::The debate between the use of radiofrequency (RF) or cryoenergy for ablation near the atrioventricular (AV) conducting system or small coronaries has been fueled by the relative efficacies and risks of the two technologies, particularly in smaller hearts. The manuscript by Schneider et al adds another chapter to that ...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 评论,社论
doi:10.1111/jce.13987
更新日期:2019-07-01 00:00:00
abstract:INTRODUCTION:Idiopathic left ventricular tachycardia typically has a right bundle branch block configuration. The purpose of this case report is to demonstrate that idiopathic ventricular tachycardia arising in or near the left posterior fascicle also may have a left bundle branch block configuration. METHODS AND RESU...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 杂志文章
doi:10.1111/j.1540-8167.1997.tb00810.x
更新日期:1997-04-01 00:00:00
abstract:BACKGROUND:Residual gaps due to incomplete ablation lines are known to be the most common cause of recurrent atrial fibrillation (AF) after catheter ablation. We hypothesized that any residual potentials at the junction of the left atrium and pulmonary vein (PV), inside the circumferential PV ablation (CPVA) lines, wou...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 杂志文章,随机对照试验
doi:10.1111/j.1540-8167.2010.01748.x
更新日期:2010-09-01 00:00:00
abstract::The remedē system is a novel fully implantable transvenous phrenic nerve stimulation (TPNS) device developed to treat central sleep apnea. No information is published on how to explant or replace its leads. An eighty-one year-old had a fractured lead and we removed it over a wire. However, unbreachable resistances occ...
journal_title:Journal of cardiovascular electrophysiology
pub_type:
doi:10.1111/jce.14725
更新日期:2020-11-01 00:00:00
abstract:INTRODUCTION:The atrial outcome after extensive ablation is unknown. We sought to quantify atrial structure and function years after successful ablation for persistent atrial fibrillation (PsAF). METHODS AND RESULTS:We studied after 80 ± 15 months 26 patients (54 ± 8 years, 1 woman) with PsAF successfully treated by a...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 杂志文章
doi:10.1111/jce.12449
更新日期:2014-07-01 00:00:00
abstract::We report two patients who had isolated atrial fibrillation in the left atrium and regular activation of the entire right atrium. Mapping of the arrhythmia was performed using a 64-electrode basket catheter that was inserted intravenously and deployed in the right and left atria. Both patients manifested a single, sta...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 杂志文章
doi:10.1111/j.1540-8167.2000.tb00014.x
更新日期:2000-05-01 00:00:00
abstract::Atrial fibrillation is the most common sustained tachyarrhythmia and, as such, has become the recent focus of intense clinical and experimental interest. Because of its associated morbidity and mortality, there is a multidisciplinary effort to understand the pathophysiology that may ultimately lead to improved therape...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 杂志文章,评审
doi:10.1111/j.1540-8167.1997.tb00855.x
更新日期:1997-08-01 00:00:00
abstract::After being struck by a car at the age of 7, an otherwise healthy boy developed recalcitrant, albeit hemodynamically, well-tolerated ventricular tachycardia. An electrophysiological study with 3-dimensional electroanatomic mapping was performed under transesophageal echocardiographic guidance at 10 years of age. Nonau...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 杂志文章
doi:10.1111/j.1540-8167.2010.01928.x
更新日期:2011-06-01 00:00:00
abstract:BACKGROUND:The purpose of this study was to assess how well acute procedural outcomes predict the clinical outcome of catheter ablation of premature ventricular complexes (PVCs). METHODS:A consecutive series of 50 patients (28 women, age: 51 ± 13 years) with frequent PVCs was referred for PVC ablation. Acute failure w...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 杂志文章
doi:10.1111/jce.12400
更新日期:2014-06-01 00:00:00
abstract:BACKGROUND:A direct indicator of effective pulmonary vein isolation (PVI) based on early ice formation is presently lacking. OBJECTIVE:The initial impedance rise within 30 to 60 seconds (sec) of single cryoablation relating to ice on the distal surface of the cryoballoon could; predict effective PVI with early termina...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 杂志文章
doi:10.1111/jce.14097
更新日期:2019-10-01 00:00:00
abstract::The heart's pacemaker, the sinoatrial node, does not consist of a group of uniform sinoatrial node cells embedded in atrial muscle. Instead, it is a heterogeneous tissue with multiple cell types and a complex structure. Evidence suggests that from the periphery to the center of the sinoatrial node, there is a gradient...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 杂志文章,评审
doi:10.1046/j.1540-8167.2003.02307.x
更新日期:2003-01-01 00:00:00
abstract:INTRODUCTION:In isolated rabbit hearts, repetitive endocardial focal discharges (REFDs) were consistently observed during ventricular fibrillation (VF) with prolonged (>5 minutes) global ischemia (GI). We hypothesized that BAPTA-AM, a calcium chelator, can suppress these REFDs. METHODS AND RESULTS:Using a two-camera o...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 杂志文章
doi:10.1111/j.1540-8167.2011.02067.x
更新日期:2011-10-01 00:00:00
abstract:INTRODUCTION:Capacitance is known to influence defibrillation. Optimal biphasic waveform capacitance for transvenous unipolar defibrillation systems in man is currently being defined. In an effort to improve defibrillation efficacy, we examined the relative defibrillation efficacy of a 65% tilt biphasic pulse from a 90...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 临床试验,杂志文章,随机对照试验
doi:10.1111/j.1540-8167.1995.tb00387.x
更新日期:1995-12-01 00:00:00
abstract:INTRODUCTION:The stability of implantable cardiac defibrillation lead impedance subsequent to implantation has not been reported and may have important clinical implications. The objective was to characterize the incidence and degree of impedance changes occurring after implantation of defibrillation lead systems. MET...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 杂志文章
doi:10.1111/j.1540-8167.1996.tb00577.x
更新日期:1996-08-01 00:00:00