Correlation of platelet growth factor release in jawbone defect repair--a study in the dog mandible.

Abstract:

BACKGROUND:Platelet concentrate/platelet-rich plasma (PRP) has been studied extensively in various experimental models and there is some agreement among workers to its early effect in bone regeneration and healing. We have earlier showed in vitro that titanium in whole blood activates the thrombogenic response to a higher degree than PRP and that a fluoridated test surface augmented the effect compared with control. PURPOSE:We designed this study to evaluate the effect of PRP and whole blood on bone regeneration in a dog implant defect model and, in addition, the effect of a test surface modified in hydrofluoric acid. A correlation attempt between platelet count, release of growth factors, and bone regeneration was made. MATERIALS AND METHODS:Six dogs were used and simultaneously with the experimental surgery and implant installation, autologous PRP was prepared. Defects were prepared (6 mm in diameter and 5 mm deep), and implants were installed (TiO2 gritblasted and hydrofluoric acid treated [test] or TiO2 gritblasted [control], 5 mm in diameter and 9 mm long) in defects filled with either PRP or whole blood. Randomization of sides between PRP and whole blood, and sites for test and control implants were made. Blood samples were collected from PRP and whole blood. The dogs were killed after 5 weeks of healing, and samples with implants and surrounding bone were collected and processed for analysis. Enzyme linked immunosorbent assays were used for detection of growth factors in PRP. RESULTS:The mean increase of platelet count was 424% in PRP. A correlation for platelet counts and transforming growth factor β was found in each dog (r(2) = 0.857). Approximately 50% of the region of interest (ROI) in the defects was filled with new bone after 5 weeks. No difference could be observed in ROI by using PRP or whole blood in the defects regarding new bone formation, bone in contact with implant, or distance to first bone contact. However, the fluoridated implants exhibited more new bone formation (p = .03) compared with control, regardless of comparing PRP or whole blood, and also displayed a shorter distance from first bone contact to the margin of the bone envelope (p = .05). CONCLUSIONS:Platelet concentrate/PRP failed to show more new bone regeneration in a peri-implant defect model compared with whole blood. Implants treated with hydrofluoric acid displayed higher percentages of bone fill in the defect.

authors

Thor AL,Hong J,Kjeller G,Sennerby L,Rasmusson L

doi

10.1111/j.1708-8208.2011.00405.x

subject

Has Abstract

pub_date

2013-10-01 00:00:00

pages

759-68

issue

5

eissn

1523-0899

issn

1708-8208

journal_volume

15

pub_type

杂志文章
  • Clinical and radiographic outcomes of reentry lateral sinus floor elevation after a complete membrane perforation.

    abstract:BACKGROUND:Although small perforation of the maxillary sinus schneiderian membrane is a well-documented complication during lateral sinus floor elevation (LSFE), complete perforations larger than 10 mm often result in discontinuation of surgery. Reports on reentry LSFE and its long-term outcomes are sparse. PURPOSE:To...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12932

    authors: Wang D,Tian J,Wang Y,Wei D,Lin Y

    更新日期:2020-10-01 00:00:00

  • Implant stability measurements using resonance frequency analysis in the grafted maxilla: a cross-sectional pilot study.

    abstract:BACKGROUND:High failure rates have been presented for implants placed in grafted bone. The bone graft-implant interface constitutes a most complex healing situation, where the time scale for osseointegration and development of implant stability currently is not known. PURPOSE:The aim of the study was to measure the st...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/j.1708-8208.1999.tb00094.x

    authors: Rasmusson L,Stegersjö G,Kahnberg KE,Sennerby L

    更新日期:1999-01-01 00:00:00

  • Single-tooth replacement in the anterior maxilla by means of immediate implantation and early loading: clinical and aesthetic results at 5 years.

    abstract:BACKGROUND:The hypothesis of the present study was that the early loading of single implants-supported restorations, replacing single extracting teeth in the anterior region of the maxilla in case of fresh extraction sockets with residual hard and soft tissue preservation, could be a successful procedure. METHODS:Twen...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12111

    authors: Guarnieri R,Ceccherini A,Grande M

    更新日期:2015-04-01 00:00:00

  • Histomorphometrical analysis following augmentation of infected extraction sites exhibiting severe bone loss and primarily closed by intrasocket reactive soft tissue.

    abstract:BACKGROUND:Intrasocket reactive soft tissue can be used for primary closure during augmentation of infected extraction sites exhibiting severe bone loss prior to implant placement. The present study evaluated the histological characteristics of the initially used intrasocket reactive soft tissue, the overlying soft tis...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/j.1708-8208.2010.00281.x

    authors: Mardinger O,Vered M,Chaushu G,Nissan J

    更新日期:2012-06-01 00:00:00

  • Elevated levels of 8-OHdG and PARK7/DJ-1 in peri-implantitis mucosa.

    abstract:BACKGROUND:Reactive oxygen species contribute to periodontal tissue homeostasis under control of anti-oxidative responses. Disruption in this balance induces severe inflammation and extended tissue degradation. PURPOSE:Aim of this study was to identify the expression levels of nuclear factor, erythroid 2 like 2 (NFE2L...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12619

    authors: Kasnak G,Firatli E,Könönen E,Olgac V,Zeidán-Chuliá F,Gursoy UK

    更新日期:2018-08-01 00:00:00

  • Long-Term Outcomes of Early Loading of Straumann Implant-Supported Fixed Segmented Bridgeworks in Edentulous Maxillae: A 10-Year Prospective Study.

    abstract:BACKGROUND:There have been few studies investigating the long-term outcome of early-loaded implants with segmented bridgeworks on fully edentulous maxillae. PURPOSE:To evaluate the long-term predictability of early-loaded Straumann implant-supported fixed segmented bridgeworks in edentulous maxillae. MATERIAL AND MET...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12420

    authors: Zhang XX,Shi JY,Gu YX,Lai HC

    更新日期:2016-12-01 00:00:00

  • Immediate occlusal loading of Brånemark TiUnite implants placed predominantly in soft bone: 1-year results of a prospective clinical study.

    abstract:BACKGROUND:The original Brånemark protocol for dental implant treatment was based on submerged healing prior to loading. However, immediate loading has been reported possible with high success rates for various indications, provided that good bone quality and quantity are present. In many of these studies, machined-sur...

    journal_title:Clinical implant dentistry and related research

    pub_type: 临床试验,杂志文章

    doi:10.1111/j.1708-8208.2003.tb00015.x

    authors: Glauser R,Lundgren AK,Gottlow J,Sennerby L,Portmann M,Ruhstaller P,Hämmerle CH

    更新日期:2003-01-01 00:00:00

  • Scientific Interests of 21st Century Clinical Oral Implant Research: Topical Trend Analysis.

    abstract:BACKGROUND:Discrimination between ongoing and solved research questions may help to distinguish established dogmas from evidence-based implant dentistry. PURPOSE:The purpose of this study was to investigate topics of interest in the field of oral implant science and evolving thematic trends in clinical studies during ...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章,评审

    doi:10.1111/cid.12371

    authors: Pommer B,Valkova V,Ubaidha Maheen C,Fürhauser L,Rausch-Fan X,Seeman R

    更新日期:2016-08-01 00:00:00

  • Biomechanical measurements of calcium-incorporated oxidized implants in rabbit bone: effect of calcium surface chemistry of a novel implant.

    abstract:BACKGROUND:In oral implantology there has been a general trend away from machine-turned minimally rough and acid-etched and blasted implants toward intermediary roughened surfaces. Mechanical interlocking at micron resolution is claimed to be the dominant reason for the fixation of such implants in bone. However, clini...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/j.1708-8208.2004.tb00032.x

    authors: Sul YT,Byon ES,Jeong Y

    更新日期:2004-01-01 00:00:00

  • Dental implant status of patients receiving long-term nursing care in Japan.

    abstract:BACKGROUND:The increase in implant patients is expected to give rise to a new problem: the changing general health status of those who have had implants placed. PURPOSE:The aim of this present study was to find out the needs of and proper measures for elderly implant patients in long-term care facilities. MATERIALS A...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12148

    authors: Kimura T,Wada M,Suganami T,Miwa S,Hagiwara Y,Maeda Y

    更新日期:2015-01-01 00:00:00

  • The effect of a 2-mm inter-implant distance on esthetic outcomes in immediately non-occlusally loaded platform shifted implants in healed ridges: 12-month results of a randomized clinical trial.

    abstract:BACKGROUND:Three millimeter is considered as the minimum distance to obtain soft and bone tissue stability in case of adjacent implants. The possibility to preserve peri-implant bone level using a platform switching connection has questioned this concept. PURPOSE:The study evaluates soft tissue maintenance and margina...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/cid.12926

    authors: Rivara F,Macaluso GM,Toffoli A,Calciolari E,Goldoni M,Lumetti S

    更新日期:2020-08-01 00:00:00

  • An experimental comparison of two different clinically used implant designs and surfaces.

    abstract:BACKGROUND:Various designs of dental implants representing different geometries and surface technologies are commercially available and clinically used in patients. However, data with regard to bone tissue responses and stability for comparison of their biologic performances are rare. PURPOSE:The aim of the present ex...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/j.1708-8208.2012.00439.x

    authors: Gottlow J,Barkarmo S,Sennerby L

    更新日期:2012-05-01 00:00:00

  • One-year outcome of implants strategically placed in the retrocanine bone triangle.

    abstract:BACKGROUND:Implant treatment in the partially edentulous maxilla is often challenging because of minimum bone volumes in distal direction. PURPOSE:The aim of this study was to evaluate, after 1 year of loading, the outcome of three-unit fixed partial dentures supported by two implants in the retrocanine triangle. MAT...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/j.1708-8208.2009.00170.x

    authors: Balleri P,Ferrari M,Veltri M

    更新日期:2010-12-01 00:00:00

  • Evaluation of immediate cell viability and repair of osteotomies for implants using drills and piezosurgery. A randomized, prospective, and controlled rabbit study.

    abstract:PURPOSE:The objective of this study was to evaluate the immediate bone damage and bone repair after osteotomy for implants using conventional drills and drills powered by piezoelectric motor. MATERIALS AND METHODS:Twelve rabbits received a tibial osteotomy with a conventional drill (control), with a diamond like carbo...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12907

    authors: Ponzoni D,Martins FEPB,Conforte JJ,Egas LS,Tonini KR,de Carvalho PSP

    更新日期:2020-06-01 00:00:00

  • Accuracy of implant impressions with different impression coping types and shapes.

    abstract:BACKGROUND:Accurate recording of implant location is required so that definitive restorations are properly supported and do not place additional stresses on the implants. Movement of impression copings inside the impression material using an open-tray or close-tray impression technique during clinical and laboratory ph...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/j.1708-8208.2009.00241.x

    authors: Rashidan N,Alikhasi M,Samadizadeh S,Beyabanaki E,Kharazifard MJ

    更新日期:2012-04-01 00:00:00

  • The midline mandibular lingual canal: importance in implant surgery.

    abstract:PURPOSE:The study aims to determine if midline mandibular dental implants pose a risk for the midline lingual canal (MLC). MATERIALS AND METHODS:Cone beam computed tomography was used to scan 122 mandibles (31 black males; 28 black females; 32 white males and 31 white females). Midsagittal sections in the reconstructe...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12080

    authors: Oettlé AC,Fourie J,Human-Baron R,van Zyl AW

    更新日期:2015-02-01 00:00:00

  • Clinical experiences of computer numeric control-milled titanium frameworks supported by implants in the edentulous jaw: a 5-year prospective study.

    abstract:BACKGROUND:Few long-term follow-up studies on treatment concepts using computer numeric control-milled titanium frameworks have been conducted. OBJECTIVE:To evaluate the clinical and radiographic performance of implant-supported prostheses provided with computer numeric control-milled titanium frameworks in the edentu...

    journal_title:Clinical implant dentistry and related research

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1111/j.1708-8208.2004.tb00036.x

    authors: Ortorp A,Jemt T

    更新日期:2004-01-01 00:00:00

  • Comparison of immediate-load mini dental implants and conventional-size dental implants to retain mandibular Kennedy class I removable partial dentures: A randomized clinical trial.

    abstract:BACKGROUND:Complications of distal extension mandibular removable partial dentures are: loss of retention, irritation, and so forth. Dental implants have been used to support distal extension removable partial dentures. However, many patients have limited bone support in which to place conventional-size dental implants...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/cid.12646

    authors: Threeburuth W,Aunmeungtong W,Khongkhunthian P

    更新日期:2018-10-01 00:00:00

  • Buccal bone thickness at dental implants in the maxillary anterior region with large bony defects at time of immediate implant placement: A 1-year cohort study.

    abstract:BACKGROUND:There is lack of studies regarding preservation and possible changes in BBT at dental implants. PURPOSE:To assess, on cone beam computer tomograms, the presence of bone at the time of tooth extraction in the maxillary esthetic region and the mean buccal bone thickness 1 month and 1 year after final restorat...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12701

    authors: Meijer HJA,Slagter KW,Vissink A,Raghoebar GM

    更新日期:2019-02-01 00:00:00

  • Fracture strength of zirconia implants after artificial aging.

    abstract:BACKGROUND:Zirconia (ZrO(2)) might be an alternative material to titanium (Ti) for dental implant fabrication. However, no data are available on the fracture strength of one-piece ZrO(2) oral implants. PURPOSE:The objective of this study was to evaluate the fracture strength of ZrO(2) implants after exposure to the ar...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/j.1708-8208.2008.00105.x

    authors: Andreiotelli M,Kohal RJ

    更新日期:2009-06-01 00:00:00

  • Long-Term Outcome of Implant Rehabilitations in Patients with Systemic Disorders and Smoking Habits: A Retrospective Clinical Study.

    abstract:BACKGROUND:There is a need for more studies investigating the outcome of implant-supported rehabilitations in patients with systemic disorders. MATERIALS AND METHODS:This retrospective clinical study included 721 patients with systemic disorders or smoking habits (422 females; 299 males), with an average age of 51 yea...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12346

    authors: Maló P,de Araújo Nobre M,Gonçalves Y,Lopes A

    更新日期:2016-08-01 00:00:00

  • The Risk of Prion Infection through Bovine Grafting Materials.

    abstract:BACKGROUND:Bovine-derived grafting materials are frequently used in a variety of bone augmentation techniques. The aim of this paper is to assess the unique safety issue of bovine-derived grafting materials that is rarely addressed in dental literature: risk of bovine spongiform encephalopathy (BSE). METHODS:The valid...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12391

    authors: Kim Y,Rodriguez AE,Nowzari H

    更新日期:2016-12-01 00:00:00

  • Peri-implant parameters and C-reactive protein levels among patients with different obesity levels.

    abstract:BACKGROUND:It is hypothesized that peri-implant conditions are worse with increasing severity of obesity, because systemic low-grade inflammatory marker (C-reactive protein [CRP]) is higher in severe form of obese individuals. PURPOSE:The aim of the cross-sectional retrospective study was to compare clinical and radio...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12556

    authors: Vohra F,Alkhudhairy F,Al-Kheraif AA,Akram Z,Javed F

    更新日期:2018-04-01 00:00:00

  • Hybrid and fully-etched surface implants in periodontally healthy patients: A comparative retrospective study on marginal bone loss.

    abstract:BACKGROUND:Human studies on implants with the same design but with different surfaces are lacking at the present time. PURPOSE:The aim of this study was to compare the survival rate of and marginal bone loss (MBL) around 2 types of implants with the same design, but with different surfaces: fully "sandblasted and doub...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12504

    authors: Spinato S,Bernardello F,Sassatelli P,Zaffe D

    更新日期:2017-08-01 00:00:00

  • Changes of Marginal Bone Level in Patients with "Progressive Bone Loss" at Brånemark System® Implants: A Radiographic Follow-Up Study over an Average of 9 Years.

    abstract:BACKGROUND:Patients have in many studies been identified with progressive bone loss and peri-implantitis problems, but few studies are available where these groups of patients have been followed up. PURPOSE:The purpose of this paper is to study further progression of bone loss in a cohort of 182 patients that have bee...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12166

    authors: Jemt T,Sundén Pikner S,Gröndahl K

    更新日期:2015-08-01 00:00:00

  • Horizontal Ridge Augmentation using GBR with a Native Collagen Membrane and 1:1 Ratio of Particulated Xenograft and Autologous Bone: A 1-Year Prospective Clinical Study.

    abstract:AIM:To clinically and radiographically evaluate bone regeneration of severe horizontal bone defects. MATERIALS AND METHODS:This study was designed as a single cohort, prospective clinical trial. Partially or fully edentulous patients, having less then 4 mm of residual horizontal bone width were selected and consecutiv...

    journal_title:Clinical implant dentistry and related research

    pub_type: 临床试验,杂志文章

    doi:10.1111/cid.12429

    authors: Meloni SM,Jovanovic SA,Urban I,Canullo L,Pisano M,Tallarico M

    更新日期:2017-02-01 00:00:00

  • Patient satisfaction and dissatisfaction with mandibular two-implant overdentures using different attachment systems: 5-year outcomes.

    abstract:BACKGROUND:Different attachment systems for mandibular two-implant overdentures could influence levels of patient satisfaction. Positive consensus of the majority of patients being satisfied does not preclude the possibility of dissatisfaction for some. PURPOSE:To evaluate patient satisfaction and dissatisfaction befo...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/j.1708-8208.2010.00306.x

    authors: Al-Zubeidi MI,Alsabeeha NH,Thomson WM,Payne AG

    更新日期:2012-10-01 00:00:00

  • Immediate fixed rehabilitation of the edentulous maxilla: a prospective clinical and radiological study after 3 years of loading.

    abstract:PURPOSE:The aim of this study was to prospectively evaluate the clinical and radiographic outcomes of immediate full-arch fixed maxillary prosthesis supported by two axial and four tilted implants after 3 years of loading. MATERIALS AND METHODS:Thirty-two patients with atrophic maxilla were consecutively enrolled and ...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/j.1708-8208.2012.00482.x

    authors: Agliardi EL,Pozzi A,Stappert CF,Benzi R,Romeo D,Gherlone E

    更新日期:2014-04-01 00:00:00

  • Mandibular implant-supported overdentures in (frail) elderly: A prospective study with 20-year follow-up.

    abstract:PURPOSE:To prospectively assess long-term (20 year) clinical, radiographic, and patient-reported outcomes of an elderly population provided with mandibular implant-supported overdentures. MATERIALS AND METHODS:A total of 53 elderly (aged ≥60 years at the time of treatment) were provided with two endosseous implants su...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12772

    authors: Bakker MH,Vissink A,Meijer HJA,Raghoebar GM,Visser A

    更新日期:2019-08-01 00:00:00

  • The profile of inflammatory cytokines in gingival crevicular fluid around healthy osseointegrated implants.

    abstract:OBJECTIVE:Regardless of gingival health and subgingival microbiology, production of cytokines within peri-implant tissues may be different from that of teeth. The objective of this study was to describe the peri-implant levels of pro-inflammatory cytokines and subgingival microbiology in clinically healthy sites. MATE...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/j.1708-8208.2010.00299.x

    authors: Nowzari H,Phamduong S,Botero JE,Villacres MC,Rich SK

    更新日期:2012-08-01 00:00:00