An experimental comparison of two different clinically used implant designs and surfaces.

Abstract:

BACKGROUND:Various designs of dental implants representing different geometries and surface technologies are commercially available and clinically used in patients. However, data with regard to bone tissue responses and stability for comparison of their biologic performances are rare. PURPOSE:The aim of the present experimental investigation was to compare the bone tissue responses and implant stability between two commonly used dental implants representing different geometries and surface characteristics. MATERIALS AND METHODS:A total of 90 dental implants (4.3 mm in diameter, 10 mm long) with an oxidized surface (Replace Select Tapered, TiUnite, Nobel Biocare AB, Gothenburg, Sweden) (OX) and 90 implants (4.1 mm in diameter, 10 mm total length) with a hydrophilic sand-blasted and acid etched surface (Standard Plus, SLActive, Institut Straumann AG, Basel, Switzerland) (HSBA) were placed in the distal femur (n = 1) and tibia (n = 2) of 30 rabbits. The implants were analyzed with implant stability quotient (ISQ) measurements, removal torque (RTQ) and histomorphometry (bone-implant contact, BIC) after 10 days, 3, and 6 weeks. Moreover, RTQ values were corrected for differences in surface area by calculating the shear strength for each implant. RESULTS:RTQ and ISQ measurements showed an increase with time for both implant types. A significantly higher RTQ value was observed for the HSBA implant at 3 weeks (p = .05). A lower ISQ value was seen for HSBA than for OX implants at placement in the tibia (p < 0.001). HSBA implants showed higher shear strength values than OX implants after 3 weeks (p < .001), and 6 weeks (p < .01). The morphometric measurements showed significantly higher BIC for HSBA implants after 10 days (p < .01), similar values after 3 weeks and significantly higher BIC for OX implants after 6 weeks (p < .001). CONCLUSIONS:Both HSBA and OX implants were well integrated in bone and showed firm and increased stability from placement to after 6 weeks of healing. The HSBA implant showed more BIC after 10 days and the OX implant more BIC after 6 weeks of healing. The HSBA implant showed significantly higher shear strength after 3 and 6 weeks and higher RTQ values after 3 weeks than the OX implant. The results may be due to differences in surface roughness and hydrophilic properties.

authors

Gottlow J,Barkarmo S,Sennerby L

doi

10.1111/j.1708-8208.2012.00439.x

subject

Has Abstract

pub_date

2012-05-01 00:00:00

pages

e204-12

eissn

1523-0899

issn

1708-8208

journal_volume

14 Suppl 1

pub_type

杂志文章
  • Clinical and radiographic outcomes of reentry lateral sinus floor elevation after a complete membrane perforation.

    abstract:BACKGROUND:Although small perforation of the maxillary sinus schneiderian membrane is a well-documented complication during lateral sinus floor elevation (LSFE), complete perforations larger than 10 mm often result in discontinuation of surgery. Reports on reentry LSFE and its long-term outcomes are sparse. PURPOSE:To...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12932

    authors: Wang D,Tian J,Wang Y,Wei D,Lin Y

    更新日期:2020-10-01 00:00:00

  • Bone formation around two titanium implant surfaces placed in bone defects with and without a bone substitute material: A histological, histomorphometric, and micro-computed tomography evaluation.

    abstract:OBJECTIVE:To evaluate the histological and microtomographic response of peri-implant bone tissue around titanium implants with different surface treatments, placed in bone defects filled or not filled with bone substitute materials. MATERIALS AND METHODS:Thirty rabbits were divided into two groups according to the imp...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12880

    authors: Trento G,de A Carvalho PH,de C Reis ENR,Spin-Neto R,Bassi APF,Pereira-Filho VA

    更新日期:2020-04-01 00:00:00

  • Autogenous bone grafting for treatment of osseous defect after impacted mandibular third molar extraction: A randomized controlled trial.

    abstract:BACKGROUND:Extraction of impacted mandibular third molar (M3) has been cited as causing osseous defect at the distal aspect of the adjacent second molar (M2). PURPOSE:This randomized controlled trial was aimed to evaluate the effect of autogenous bone grafting in situ for regeneration of periodontal osseous defect dis...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/cid.12466

    authors: Ge J,Yang C,Zheng J,Hu Y

    更新日期:2017-06-01 00:00:00

  • Infraposition of anterior maxillary implant-supported single-tooth restorations in adolescent and adult patients-A prospective follow-up study up to 6 years.

    abstract:BACKGROUND:In the maxillary incisor area infraposition of implant restorations can be an esthetic problem. PURPOSE:The aim was to analyze the prevalence of infraposition of single-tooth implant restorations in the anterior maxilla in adolescent and adult patients. MATERIAL AND METHODS:The study comprised of 31 patien...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12818

    authors: Nilsson A,Johansson LÅ,Stenport VF,Wennerberg A,Ekfeldt A

    更新日期:2019-10-01 00:00:00

  • CAD/CAM implant crowns in a digital workflow: Five-year follow-up of a prospective clinical trial.

    abstract:BACKGROUND:Implant restorations became the first choice for single-tooth replacement today. PURPOSE:The prospective clinical trial aims to investigate computer-aided-design (CAD)/computer-aided-manufacturing (CAM)-processed implant crowns after 5 years of loading. MATERIALS AND METHODS:Twenty patients were included f...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/cid.12681

    authors: Joda T,Bragger U,Zitzmann NU

    更新日期:2019-02-01 00:00:00

  • Scientific Interests of 21st Century Clinical Oral Implant Research: Topical Trend Analysis.

    abstract:BACKGROUND:Discrimination between ongoing and solved research questions may help to distinguish established dogmas from evidence-based implant dentistry. PURPOSE:The purpose of this study was to investigate topics of interest in the field of oral implant science and evolving thematic trends in clinical studies during ...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章,评审

    doi:10.1111/cid.12371

    authors: Pommer B,Valkova V,Ubaidha Maheen C,Fürhauser L,Rausch-Fan X,Seeman R

    更新日期:2016-08-01 00:00:00

  • The radiological evaluation of posterior superior alveolar artery topography by using computed tomography.

    abstract:BACKGROUND:Posterior superior alveolar artery (PSAA) is the most important limiting anatomic structure while lateral approach sinus surgeries. PSAA should be taken into consideration to avoid bleeding during preparation of bony window. PURPOSE:The aim of this article was to inform topography of PSAA and to evaluate me...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12794

    authors: Duruel O,Ataman-Duruel ET,Tözüm MD,Karabulut E,Tözüm TF

    更新日期:2019-08-01 00:00:00

  • Fibrin clot extension on zirconia surface for dental implants: a quantitative in vitro study.

    abstract:PURPOSE:The surface chemical and physical properties of materials used for implants have a major influence on blood clot organization. This study aims to evaluate the blood clot extension (bce) on zirconia and titanium. bce was measured in association to surface roughness (Ra) and static contact angle (θ). MATERIALS A...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12038

    authors: Traini T,Caputi S,Gherlone E,Degidi M,Piattelli A

    更新日期:2014-10-01 00:00:00

  • Horizontal Ridge Augmentation using GBR with a Native Collagen Membrane and 1:1 Ratio of Particulated Xenograft and Autologous Bone: A 1-Year Prospective Clinical Study.

    abstract:AIM:To clinically and radiographically evaluate bone regeneration of severe horizontal bone defects. MATERIALS AND METHODS:This study was designed as a single cohort, prospective clinical trial. Partially or fully edentulous patients, having less then 4 mm of residual horizontal bone width were selected and consecutiv...

    journal_title:Clinical implant dentistry and related research

    pub_type: 临床试验,杂志文章

    doi:10.1111/cid.12429

    authors: Meloni SM,Jovanovic SA,Urban I,Canullo L,Pisano M,Tallarico M

    更新日期:2017-02-01 00:00:00

  • Bone formation at titanium implants prepared with iso- and anisotropic surfaces of similar roughness: an in vivo study.

    abstract:BACKGROUND:Implant surface topography influences the bone response after implantation. However, the importance of surface orientation is not known. PURPOSE:The aim of this study was to investigate the bone tissue response and the stability of titanium implants prepared with isotropic and anisotropic surfaces of simila...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/j.1708-8208.2005.tb00042.x

    authors: Göransson A,Wennerberg A

    更新日期:2005-01-01 00:00:00

  • Relationship between self-rated pain and peri-implant clinical, radiographic and whole salivary inflammatory markers among patients with and without peri-implantitis.

    abstract:BACKGROUND:There are no studies that have evaluated the correlation between self-rated pain, peri-implant clinical and radiographic parameters (plaque index [PI], bleeding on probing [BOP], probing depth [PD], and crestal bone loss [CBL]) and whole salivary interleukin (IL)-1β, IL-6, and tumor necrosis factor-alpha (TN...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12866

    authors: Abduljabbar T,Vohra F,Ullah A,Alhamoudi N,Khan J,Javed F

    更新日期:2019-12-01 00:00:00

  • Impact of bone harvesting techniques on cell viability and the release of growth factors of autografts.

    abstract:BACKGROUND:Autogenous bone grafts obtained by different harvesting techniques behave differently during the process of graft consolidation; the underlying reasons are however not fully understood. One theory is that harvesting techniques have an impact on the number and activity of the transplanted cells which contribu...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/j.1708-8208.2012.00440.x

    authors: Miron RJ,Gruber R,Hedbom E,Saulacic N,Zhang Y,Sculean A,Bosshardt DD,Buser D

    更新日期:2013-08-01 00:00:00

  • Time-dependent changes in fresh-frozen bone block grafts: tomographic, histologic, and histomorphometric findings.

    abstract:BACKGROUND:Bone allografts have shown satisfactory clinical results in alveolar ridge reconstructions. However, the process of incorporation and the resorption rates of these grafts are not yet fully understood. PURPOSE:The aim of this study was to use computed tomography (CT), histology, and histomorphometry to asses...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/cid.12108

    authors: Deluiz D,Oliveira LS,Pires FR,Tinoco EM

    更新日期:2015-04-01 00:00:00

  • Dental implant status of patients receiving long-term nursing care in Japan.

    abstract:BACKGROUND:The increase in implant patients is expected to give rise to a new problem: the changing general health status of those who have had implants placed. PURPOSE:The aim of this present study was to find out the needs of and proper measures for elderly implant patients in long-term care facilities. MATERIALS A...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12148

    authors: Kimura T,Wada M,Suganami T,Miwa S,Hagiwara Y,Maeda Y

    更新日期:2015-01-01 00:00:00

  • Long-term clinical, microbiological, and radiographic outcomes of Brånemark™ implants installed in augmented maxillary bone for fixed full-arch rehabilitation.

    abstract:PURPOSE:The purpose of this study was to document the long-term outcome of Brånemark implants installed in augmented maxillary bone and to identify parameters that are associated with peri-implant bone level. MATERIAL AND METHODS:Patients of a periodontal practice who had been referred to a maxillofacial surgeon for i...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/j.1708-8208.2011.00359.x

    authors: De Bruyn H,Bouvry P,Collaert B,De Clercq C,Persson GR,Cosyn J

    更新日期:2013-02-01 00:00:00

  • Rehabilitation of edentulous mandibles by means of five TiUnite implants after one-stage surgery: a 1-year retrospective study of 90 patients.

    abstract:BACKGROUND:Recently, the present team reported the 1-year data of one-stage surgery and mainly early loading performed in edentulous mandibles using 750 turned Brånemark System implants in 152 patients. PURPOSE:The aim of the present investigation was to retrospectively evaluate the 1-year results of the same treatmen...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/j.1708-8208.2007.00060.x

    authors: Friberg B,Jemt T

    更新日期:2008-03-01 00:00:00

  • A long-term prospective cohort study on immediately restored single tooth implants inserted in extraction sockets and healed ridges: CBCT analyses, soft tissue alterations, aesthetic ratings, and patient-reported outcomes.

    abstract:BACKGROUND:Although many studies have been published on single implants, long-term data remain scarce. PURPOSE:To evaluate immediately restored single implants after at least 8 years of follow-up in terms of buccal bone, soft tissue alterations, aesthetic ratings, and patient-reported outcomes. MATERIALS AND METHODS:...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12613

    authors: Raes S,Eghbali A,Chappuis V,Raes F,De Bruyn H,Cosyn J

    更新日期:2018-08-01 00:00:00

  • Osseointegrated implant for single-tooth replacement: a retrospective multicenter study on routine use in private practice.

    abstract:BACKGROUND:Implant restorations first started with total edentulism. Later, the scientific community gave its approval for restorations in partial edentulism, and only recently some studies confirmed the validity of the treatment for single-tooth replacement. PURPOSE:The purpose of the study was to evaluate implant su...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章,多中心研究

    doi:10.1111/j.1708-8208.2000.tb00006.x

    authors: Bianco G,Di Raimondo R,Luongo G,Paoleschi C,Piccoli P,Piccoli C,Rangert B

    更新日期:2000-01-01 00:00:00

  • Immediate occlusal loading of Brånemark TiUnite implants placed predominantly in soft bone: 1-year results of a prospective clinical study.

    abstract:BACKGROUND:The original Brånemark protocol for dental implant treatment was based on submerged healing prior to loading. However, immediate loading has been reported possible with high success rates for various indications, provided that good bone quality and quantity are present. In many of these studies, machined-sur...

    journal_title:Clinical implant dentistry and related research

    pub_type: 临床试验,杂志文章

    doi:10.1111/j.1708-8208.2003.tb00015.x

    authors: Glauser R,Lundgren AK,Gottlow J,Sennerby L,Portmann M,Ruhstaller P,Hämmerle CH

    更新日期:2003-01-01 00:00:00

  • Clinical and radiographic peri-implant outcomes of short dental implants placed in posterior jaws of patients with treated generalized aggressive periodontitis: A 3-year follow-up study.

    abstract:BACKGROUND:Studies assessing clinical and radiographic peri-implant parameters around short dental implants (SDIs) in treated generalized aggressive periodontitis (GAgP) patients are scant. OBJECTIVES:This 3-year follow-up study aimed to compare the clinical peri-implant and radiographic bone status around SDIs placed...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12761

    authors: Akram Z,Vohra F,Sheikh SA,Albaijan R,Bukhari IA,Hussain M

    更新日期:2019-08-01 00:00:00

  • Syncrystallization: a technique for temporization of immediately loaded implants with metal-reinforced acrylic resin restorations.

    abstract:BACKGROUND:Rigid temporization has been recognized to have a significant impact on the peri-implant tissue response in immediate implant loading since it reduces the mechanical stress exerted on each implant. PURPOSE:A successful protocol for immediate loading of multiple implants depends on an adequate fixation and i...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/j.1708-8208.2006.00011.x

    authors: Degidi M,Gehrke P,Spanel A,Piattelli A

    更新日期:2006-01-01 00:00:00

  • Accuracy of two stereolithographic surgical templates: a retrospective study.

    abstract:BACKGROUND:The use of computer software and stereolithography for dental implant therapy has significantly increased during the last few years. The aim of this study was to evaluate and compare the mean accuracy and maximum deviations values of dental implant placement using two stereolithographic (SLA) guide systems. ...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/j.1708-8208.2011.00369.x

    authors: Cassetta M,Giansanti M,Di Mambro A,Calasso S,Barbato E

    更新日期:2013-06-01 00:00:00

  • Clinical and radiographic peri-implant parameters and proinflammatory cytokine levels among cigarette smokers, smokeless tobacco users, and nontobacco users.

    abstract:BACKGROUND:It is postulated that clinical and radiographic peri-implant parameters are worse and levels of interleukin (IL)-1β and matrix metalloproteinase (MMP)-9 in the peri-implant sulcular fluid (PISF) are higher in cigarette-smokers (CS) and smokeless-tobacco users (STU) compared with nontobacco user (NTU). PURPO...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12575

    authors: Akram Z,Vohra F,Bukhari IA,Sheikh SA,Javed F

    更新日期:2018-02-01 00:00:00

  • A 10-year clinical and radiographic study of implants placed after maxillary sinus floor augmentation with an 80:20 mixture of deproteinized bovine bone and autogenous bone.

    abstract:BACKGROUND:There is a need for prospective, long-term follow-up studies of implants placed after maxillary sinus floor augmentation (MSFA). PURPOSE:The aim of the present study was to determine whether deprotenized bovine bone (DPBB) used for MSFA may result in long-term stability of placed dental implants. MATERIAL ...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12008

    authors: Mordenfeld A,Albrektsson T,Hallman M

    更新日期:2014-06-01 00:00:00

  • Hybrid and fully-etched surface implants in periodontally healthy patients: A comparative retrospective study on marginal bone loss.

    abstract:BACKGROUND:Human studies on implants with the same design but with different surfaces are lacking at the present time. PURPOSE:The aim of this study was to compare the survival rate of and marginal bone loss (MBL) around 2 types of implants with the same design, but with different surfaces: fully "sandblasted and doub...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12504

    authors: Spinato S,Bernardello F,Sassatelli P,Zaffe D

    更新日期:2017-08-01 00:00:00

  • Dental Implant Macro-Design Features Can Impact the Dynamics of Osseointegration.

    abstract:PURPOSE:The purpose of this study was to compare the clinical performance of two dental implant types possessing a different macro-design in the in vivo pig model. MATERIALS AND METHODS:Titanium Aadva(TM) implants (GC, Tokyo, Japan) were compared with OsseoSpeed(TM) implants (Astra, Mölndal, Sweden), with the Aadva im...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12178

    authors: Vivan Cardoso M,Vandamme K,Chaudhari A,De Rycker J,Van Meerbeek B,Naert I,Duyck J

    更新日期:2015-08-01 00:00:00

  • Rational design and in vitro characterization of novel dental implant and abutment surfaces for balancing clinical and biological needs.

    abstract:BACKGROUND:Long-term success and patient satisfaction of dental implant systems can only be achieved by fulfilling clinical as well as biological needs related to maintenance, aesthetics, soft tissue sealing, and osseointegration, among others. Surface properties largely contribute to the biological and clinical perfor...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12736

    authors: Milleret V,Lienemann PS,Gasser A,Bauer S,Ehrbar M,Wennerberg A

    更新日期:2019-03-01 00:00:00

  • One-year prospective three-center study comparing the outcome of a "soft bone implant" (prototype Mk IV) and the standard Brånemark implant.

    abstract:BACKGROUND:Oral implant treatment ad modum Brånemark has been used for decades in the rehabilitation of edentate and partially dentate patients. Posterior jaw regions frequently exhibit bone of poor texture, and it is often difficult to obtain primary stability. Thus, it may prove beneficial to deviate from the origina...

    journal_title:Clinical implant dentistry and related research

    pub_type: 临床试验,杂志文章,多中心研究,随机对照试验

    doi:10.1111/j.1708-8208.2003.tb00186.x

    authors: Friberg B,Jisander S,Widmark G,Lundgren A,Ivanoff CJ,Sennerby L,Thorén C

    更新日期:2003-01-01 00:00:00

  • Turned, machined versus double-etched dental implants in vivo.

    abstract:BACKGROUND:Positive effects on the clinical outcome of moderately rough implant surfaces are described. Intercomparison of clinical data, however, is rarely found. PURPOSE:The aim of this study was to compare the clinical results of two macroscopically identical implants, the one with a turned, machined and the other ...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/j.1708-8208.2007.00030.x

    authors: Al-Nawas B,Hangen U,Duschner H,Krummenauer F,Wagner W

    更新日期:2007-06-01 00:00:00

  • Accuracy of linear measurement provided by cone beam computed tomography to assess bone quantity in the posterior maxilla: a human cadaver study.

    abstract:PURPOSE:The aim of this study was to assess, for implant placement in the posterior maxilla, the accuracy of linear measurements provided by cone beam computed tomography (CBCT) using an image intensifier tube and television (TV) chain as an X-ray detector despite a loss of contrast resolution. The NewTom 9000 (Quantit...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/j.1708-8208.2008.00083.x

    authors: Veyre-Goulet S,Fortin T,Thierry A

    更新日期:2008-12-01 00:00:00