Deubiquitylating enzyme USP2 counteracts Nedd4-2-mediated downregulation of KCNQ1 potassium channels.

Abstract:

BACKGROUND:KCNQ1 (Kv7.1), together with its KCNE β subunits, plays a pivotal role both in the repolarization of cardiac tissue and in water and salt transport across epithelial membranes. Nedd4/Nedd4-like (neuronal precursor cell-expressed developmentally downregulated 4) ubiquitin-protein ligases interact with the KCNQ1 potassium channel through a PY motif located in the C terminus of KCNQ1. This interaction induces ubiquitylation of KCNQ1, resulting in a reduced surface density of the channel. It was reported recently that the epithelial sodium channel is regulated by the reverse process-deubiquitylation-mediated by USP2 (ubiquitin-specific protease 2). OBJECTIVE:In this article, we investigated whether deubiquitylation may regulate KCNQ1 channel complexes. METHODS:In this study, we used electrophysiology, biochemistry, and confocal microscopy. RESULTS:Electrophysiological investigations of KCNQ1/KCNE1 proteins coexpressed with USP2-45 or USP2-69 isoforms and Nedd4-2 in Xenopus laevis oocytes and mammalian cells revealed that both USP2 isoforms counter the Nedd4-2-specific downregulation of I(Ks). Biochemical studies showed that the total and surface-expressed KCNQ1 protein was more abundant when coexpressed with USP2 and Nedd4-2 as compared with Nedd4-2 alone. Western blotting revealed partial protection against covalent attachment of ubiquitin moieties on KCNQ1 when USP2 was coexpressed with Nedd4-2. Coimmunoprecipitation assays suggested that USP2 can bind to KCNQ1 independently of the PY motif. Immunocytochemistry confirmed that USP2 restores the membrane localization of KCNQ1. CONCLUSION:These results demonstrate that USP2 can be a potent regulator of KCNQ1 surface density. USP2, which is well expressed in many tissues, may therefore be important in controlling the KCNQ1 channel dynamics in vivo.

journal_name

Heart Rhythm

journal_title

Heart rhythm

authors

Krzystanek K,Rasmussen HB,Grunnet M,Staub O,Olesen SP,Abriel H,Jespersen T

doi

10.1016/j.hrthm.2011.10.026

subject

Has Abstract

pub_date

2012-03-01 00:00:00

pages

440-8

issue

3

eissn

1547-5271

issn

1556-3871

pii

S1547-5271(11)01254-9

journal_volume

9

pub_type

杂志文章
  • Implantable cardioverter-defibrillator therapy and risk of congestive heart failure or death in MADIT II patients with atrial fibrillation.

    abstract:BACKGROUND:Atrial fibrillation (AF) contributes to increased risk of morbidity and mortality. Data regarding the effectiveness of implantable cardioverter-defibrillator (ICD) therapy in AF patients are limited. OBJECTIVES:The purpose of this study was to evaluate the effectiveness of ICD therapy in patients with AF en...

    journal_title:Heart rhythm

    pub_type: 杂志文章

    doi:10.1016/j.hrthm.2006.02.012

    authors: Zareba W,Steinberg JS,McNitt S,Daubert JP,Piotrowicz K,Moss AJ,MADIT II Investigators.

    更新日期:2006-06-01 00:00:00

  • Bidirectional ventricular tachycardia: ping pong in the His-Purkinje system.

    abstract:BACKGROUND:Bidirectional ventricular tachycardia (BVT), which is characterized by an alternating beat-to-beat ECG QRS axis, is a rare but intriguing arrhythmia associated with digitalis toxicity, familial catecholaminergic polymorphic ventricular tachycardia (CPVT), and several other conditions that predispose cardiac ...

    journal_title:Heart rhythm

    pub_type: 杂志文章

    doi:10.1016/j.hrthm.2010.11.038

    authors: Baher AA,Uy M,Xie F,Garfinkel A,Qu Z,Weiss JN

    更新日期:2011-04-01 00:00:00

  • An alternative under-valve approach to ablate right-sided accessory pathways.

    abstract:BACKGROUND:Right-sided accessory pathway (RAP) ablation is sometimes challenging. OBJECTIVE:Our study aimed to demonstrate an alternative ablation approach to RAPs under the tricuspid valve, especially when the conventional ablation attempts at the atrial side failed. METHODS:Twelve patients with RAPs were enrolled, ...

    journal_title:Heart rhythm

    pub_type: 杂志文章

    doi:10.1016/j.hrthm.2018.07.022

    authors: Yang J,Yang G,Chen H,Ju W,Yang B,Zhang F,Jin Y,Cao J,Qian L,Chen M

    更新日期:2019-01-01 00:00:00

  • Atrial fibrillation occurring during head-up tilt testing: Once detected, atrial fibrillation should be monitored, regardless of how it is detected.

    abstract:BACKGROUND:Atrial fibrillation (AF) often progresses to more sustained forms and increases the risk of ischemic stroke or sinus node dysfunction. However, there have been no data on the clinical outcomes of patients who developed AF during head-up tilt testing (HUT). OBJECTIVE:The purpose of this study was to evaluate...

    journal_title:Heart rhythm

    pub_type: 杂志文章

    doi:10.1016/j.hrthm.2018.11.030

    authors: Kim JH,Lee SH,Park SJ,Park KM,On YK,Kim JS

    更新日期:2019-04-01 00:00:00

  • Automatic measurement of atrial pacing thresholds in dual-chamber pacemakers: clinical experience with atrial capture management.

    abstract:BACKGROUND:The Medtronic EnPulse pacemaker incorporates the new atrial capture management (ACM) algorithm to automatically measure atrial capture thresholds and subsequently manage atrial pacing outputs. OBJECTIVES:The purpose of this study was to evaluate the clinical performance of ACM. METHODS:Two hundred patients...

    journal_title:Heart rhythm

    pub_type: 临床试验,杂志文章,多中心研究

    doi:10.1016/j.hrthm.2005.07.023

    authors: Sperzel J,Milasinovic G,Smith TW,Mead H,Brandt J,Haisty WK,Bailey JR,Roelke M,Simonson J,Englund J,Farges E,Compton S

    更新日期:2005-11-01 00:00:00

  • High-frequency powers hidden within QRS complex as an additional predictor of lethal ventricular arrhythmias to ventricular late potential in post-myocardial infarction patients.

    abstract:BACKGROUND:Ventricular late potentials (VLPs) have been known to be a predictor of lethal ventricular arrhythmias (L-VAs); however, detection of other arrhythmogenic signals within the QRS complex remains obscure. OBJECTIVE:The aim of this study was to evaluate whether abnormal intra-QRS high-frequency powers (IQHFP) ...

    journal_title:Heart rhythm

    pub_type: 杂志文章

    doi:10.1016/j.hrthm.2011.06.027

    authors: Tsutsumi T,Takano N,Matsuyama N,Higashi Y,Iwasawa K,Nakajima T

    更新日期:2011-10-01 00:00:00

  • Stepwise ablation approach versus pulmonary vein isolation in patients with paroxysmal atrial fibrillation: Randomized controlled trial.

    abstract:BACKGROUND:Pulmonary vein isolation (PVI) is a central procedure for the treatment of paroxysmal atrial fibrillation (PAF). However, in patients with PAF and structural atrial disease, PVI may fail and cause progressive atrial remodeling, often leading to persistent/permanent atrial fibrillation. OBJECTIVE:We performe...

    journal_title:Heart rhythm

    pub_type: 杂志文章,多中心研究,随机对照试验

    doi:10.1016/j.hrthm.2015.06.009

    authors: Faustino M,Pizzi C,Agricola T,Xhyheri B,Costa GM,Flacco ME,Capasso L,Cicolini G,Di Girolamo E,Leonzio L,Manzoli L

    更新日期:2015-09-01 00:00:00

  • Intracardiac QT integral on far-field ICD electrogram predicts sustained ventricular tachyarrhythmias in ICD patients.

    abstract:BACKGROUND:Prediction of sustained ventricular tachycardia (VT)/ventricular fibrillation (VF) could help to guide preventive interventions in at-risk patients. The QRST integral (∫QT) reflects intrinsic repolarization properties. OBJECTIVE:The objective of this study was to determine whether intracardiac ∫QT predicts ...

    journal_title:Heart rhythm

    pub_type: 杂志文章

    doi:10.1016/j.hrthm.2011.07.029

    authors: Tereshchenko LG,Ghanem RN,Abeyratne A,Swerdlow CD

    更新日期:2011-12-01 00:00:00

  • Feasibility, accuracy, and safety of 3-dimensional electroanatomic mapping without fluoroscopy in patients with congenital heart defects.

    abstract:BACKGROUND:Use of nonfluoroscopic 3-dimensional electroanatomic mapping (NF-3DEAM) in patients with congenital heart defects (CHDs) is not well reported. OBJECTIVE:The purpose of this study was to evaluate the feasibility, accuracy, and safety of NF-3DEAM in patients with CHDs. METHODS:Retrospective review of electro...

    journal_title:Heart rhythm

    pub_type: 杂志文章

    doi:10.1016/j.hrthm.2016.04.010

    authors: Bharmanee A,Gowda S,Singh HR

    更新日期:2016-08-01 00:00:00

  • Left atrial appendage closure device implantation in patients at very high risk for stroke.

    abstract:BACKGROUND:Little is known about the role of left atrial appendage closure using the Watchman device (Boston Scientific) in patients who are at very high risk for stroke. OBJECTIVE:The purpose of this study was to assess the role of Watchman in patients with CHA2DS2-VASc ≥5. METHODS:All patients undergoing procedures...

    journal_title:Heart rhythm

    pub_type: 杂志文章

    doi:10.1016/j.hrthm.2019.07.011

    authors: Hutt E,Wazni OM,Kaur S,Saliba WI,Tarakji KG,Kapadia S,Aguilera J,Barakat AF,Abdallah M,Jaber W,Rasmussen P,Hussain S,Uchino K,Wisco D,Lindsay BD,Kanj M,Hussein AA

    更新日期:2020-01-01 00:00:00

  • Leadless pacemaker implantation after explantation of infected conventional pacemaker systems: A viable solution?

    abstract:BACKGROUND:Conventional cardiac device infections are increasing in incidence, causing significant morbidity and mortality. Leadless pacemaker (LP) therapy may provide new opportunities for the management of pacemaker (PM) infections as it does not require implantation of transvenous leads and a pectoral pocket. OBJEC...

    journal_title:Heart rhythm

    pub_type: 杂志文章

    doi:10.1016/j.hrthm.2018.07.006

    authors: Beurskens NEG,Tjong FVY,Dasselaar KJ,Kuijt WJ,Wilde AAM,Knops RE

    更新日期:2019-01-01 00:00:00

  • A novel radiofrequency ablation catheter using contact force sensing: Toccata study.

    abstract:OBJECTIVES:The aim of this multicenter study was to evaluate the device- and procedure-related safety of a novel force-sensing radiofrequency (RF) ablation catheter capable of measuring the real-time contact force (CF) and to present CF data and its possible implications on patient safety. BACKGROUND:The clinical outc...

    journal_title:Heart rhythm

    pub_type: 杂志文章,多中心研究

    doi:10.1016/j.hrthm.2011.08.021

    authors: Kuck KH,Reddy VY,Schmidt B,Natale A,Neuzil P,Saoudi N,Kautzner J,Herrera C,Hindricks G,Jaïs P,Nakagawa H,Lambert H,Shah DC

    更新日期:2012-01-01 00:00:00

  • How to use the 12-lead ECG to predict the site of origin of idiopathic ventricular arrhythmias.

    abstract::Idiopathic ventricular arrhythmias may arise from anywhere in the heart, and the majority of them can be effectively treated with catheter ablation. The 12-lead electrocardiogram (ECG) is the initial mapping tool to predict the most likely site of origin and is valuable to choose the appropriate ablation strategy. Cru...

    journal_title:Heart rhythm

    pub_type: 杂志文章,评审

    doi:10.1016/j.hrthm.2019.04.002

    authors: Enriquez A,Baranchuk A,Briceno D,Saenz L,Garcia F

    更新日期:2019-10-01 00:00:00

  • Endocardial or epicardial ventricular tachycardia in nonischemic cardiomyopathy? The role of 12-lead ECG criteria in clinical practice.

    abstract:BACKGROUND:Specific 12-lead ECG criteria have been reported to predict an epicardial site of origin (SoO) of induced ventricular tachycardias (VTs) in left ventricular nonischemic cardiomyopathy. OBJECTIVE:The purpose of this study was to (1) determine the value of ECG criteria to predict an epicardial SoO of clinical...

    journal_title:Heart rhythm

    pub_type: 杂志文章

    doi:10.1016/j.hrthm.2014.03.001

    authors: Piers SR,Silva Mde R,Kapel GF,Trines SA,Schalij MJ,Zeppenfeld K

    更新日期:2014-06-01 00:00:00

  • History and clinical significance of early repolarization syndrome.

    abstract::The early repolarization (ER) pattern has historically been regarded as a benign ECG variant. However, in recent years this view has been challenged based on multiple reports linking the ER pattern with an increased risk of sudden cardiac death. The mechanistic basis of ventricular arrhythmogenesis in ER syndrome is p...

    journal_title:Heart rhythm

    pub_type: 杂志文章

    doi:10.1016/j.hrthm.2014.09.048

    authors: Mahida S,Derval N,Sacher F,Berte B,Yamashita S,Hooks DA,Denis A,Lim H,Amraoui S,Aljefairi N,Hocini M,Jais P,Haissaguerre M

    更新日期:2015-01-01 00:00:00

  • Safety of magnetic resonance imaging scanning in patients with cardiac resynchronization therapy-defibrillators incorporating quadripolar left ventricular leads.

    abstract:BACKGROUND:Magnetic resonance imaging (MRI) scanning of magnetic resonance (MR)-conditional cardiac implantable cardioverter-defibrillators (ICDs) can be performed safely following specific protocols. MRI safety with cardiac resynchronization therapy-defibrillators (CRT-Ds) incorporating quadripolar left ventricular (L...

    journal_title:Heart rhythm

    pub_type: 杂志文章

    doi:10.1016/j.hrthm.2020.08.020

    authors: Rinaldi CA,Vitoff PJ,Nair DG,Bernstein R,Mountantonakis SE,Rapacciuolo A,Carter N,Tse HF,Green UB

    更新日期:2020-12-01 00:00:00

  • Low incidence of complications after cephalic vein cutdown for pacemaker lead implantation in children weighing less than 10 kilograms: A single-center experience with long-term follow-up.

    abstract:BACKGROUND:Only a few studies on the cephalic vein cutdown technique for pacemaker lead implantation in children weighing ≤10 kg have been reported even though the procedure is widely accepted in adults. OBJECTIVE:The purpose of this study was to prove that cephalic vein cutdown for pacemaker lead implantation is a re...

    journal_title:Heart rhythm

    pub_type: 杂志文章

    doi:10.1016/j.hrthm.2015.04.025

    authors: Kircanski B,Vasic D,Savic D,Stojanov P

    更新日期:2015-08-01 00:00:00

  • Epicardial leads in adult cardiac resynchronization therapy recipients: a study on lead performance, durability, and safety.

    abstract:BACKGROUND:Transvenous left ventricular (LV) lead placement for cardiac resynchronization therapy-defibrillator (CRT-D) delivery is unsuccessful in 8% to 10% of cases. These patients might benefit from an epicardial lead. However, data on long-term epicardial lead performance are scarce. Furthermore, extracting an epic...

    journal_title:Heart rhythm

    pub_type: 杂志文章

    doi:10.1016/j.hrthm.2014.11.004

    authors: Buiten MS,van der Heijden AC,Klautz RJM,Schalij MJ,van Erven L

    更新日期:2015-03-01 00:00:00

  • Antiarrhythmic effect of vernakalant in electrically remodeled goat atria is caused by slowing of conduction and prolongation of postrepolarization refractoriness.

    abstract:BACKGROUND:Vernakalant inhibits several potassium currents and causes a rate- and voltage-dependent inhibition of the sodium current. OBJECTIVE:The aim of this study was to evaluate the antiarrhythmic mechanism of vernakalant in normal and electrically remodeled atria. METHODS:Fourteen goats were instrumented with el...

    journal_title:Heart rhythm

    pub_type: 杂志文章

    doi:10.1016/j.hrthm.2015.12.009

    authors: van Hunnik A,Lau DH,Zeemering S,Kuiper M,Verheule S,Schotten U

    更新日期:2016-04-01 00:00:00

  • Prognostic significance of ventricular late potentials in patients with pulmonary sarcoidosis.

    abstract:BACKGROUND:Early detection of cardiac involvement in sarcoidosis is difficult but essential to achieve optimal treatment. Signal-averaged electrocardiography (SAECG) can detect subtle cardiac electrical abnormalities termed late potentials (LPs) and would be useful for the early diagnosis of cardiac involvement. OBJEC...

    journal_title:Heart rhythm

    pub_type: 杂志文章

    doi:10.1016/j.hrthm.2018.03.013

    authors: Yodogawa K,Seino Y,Ohara T,Iwasaki YK,Hayashi M,Miyauchi Y,Azuma A,Shimizu W

    更新日期:2018-06-01 00:00:00

  • IKs blockade reduces dispersion of repolarization in heart failure.

    abstract:BACKGROUND:The slow and rapid (I(Kr)) components of I(K) are major determinants of ventricular repolarization. Unlike I(Kr), which is homogeneously expressed across the transmural wall, I(Ks) expression is reduced in midmyocardial cells and presumably contributes significantly to transmural dispersion of repolarization...

    journal_title:Heart rhythm

    pub_type: 杂志文章

    doi:10.1016/j.hrthm.2005.04.015

    authors: Pajouh M,Wilson LD,Poelzing S,Johnson NJ,Rosenbaum DS

    更新日期:2005-07-01 00:00:00

  • System survival of nontransvenous implantable cardioverter-defibrillators compared to transvenous implantable cardioverter-defibrillators in pediatric and congenital heart disease patients.

    abstract:BACKGROUND:Nontransvenous (NTV) implantable cardioverter-defibrillator (ICD) systems with pericardial and/or subcutaneous coils are used in select pediatric and congenital heart disease patients who are not candidates for transvenous ICD leads. Outcomes with these hybrid configurations are not well understood. OBJECTI...

    journal_title:Heart rhythm

    pub_type: 杂志文章

    doi:10.1016/j.hrthm.2009.10.014

    authors: Radbill AE,Triedman JK,Berul CI,Fynn-Thompson F,Atallah J,Alexander ME,Walsh EP,Cecchin F

    更新日期:2010-01-01 00:00:00

  • Utilization of implantable cardioverter-defibrillators for the prevention of sudden cardiac death in emerging countries: Improve SCA clinical trial.

    abstract:BACKGROUND:Implantable cardioverter-defibrillators (ICDs) are underutilized in Asia, Latin America, Eastern Europe, the Middle East, and Africa. The Improve SCA Study is the largest prospective study to evaluate the benefit of ICD therapy in underrepresented geographies. This analysis reports the primary objective of t...

    journal_title:Heart rhythm

    pub_type: 杂志文章

    doi:10.1016/j.hrthm.2019.09.023

    authors: Zhang S,Ching CK,Huang D,Liu YB,Rodriguez-Guerrero DA,Hussin A,Kim YH,Chasnoits AR,Cerkvenik J,Lexcen DR,Muckala K,Brown ML,Cheng A,Singh B,Improve SCA Investigators.

    更新日期:2020-03-01 00:00:00

  • Targeted sequencing in candidate genes for atrial fibrillation: the Cohorts for Heart and Aging Research in Genomic Epidemiology (CHARGE) Targeted Sequencing Study.

    abstract:BACKGROUND:Genome-wide association studies (GWAS) have identified common genetic variants that predispose to atrial fibrillation (AF). It is unclear whether rare and low-frequency variants in genes implicated by such GWAS confer additional risk of AF. OBJECTIVE:To study the association of genetic variants with AF at G...

    journal_title:Heart rhythm

    pub_type: 杂志文章

    doi:10.1016/j.hrthm.2013.11.012

    authors: Lin H,Sinner MF,Brody JA,Arking DE,Lunetta KL,Rienstra M,Lubitz SA,Magnani JW,Sotoodehnia N,McKnight B,McManus DD,Boerwinkle E,Psaty BM,Rotter JI,Bis JC,Gibbs RA,Muzny D,Kovar CL,Morrison AC,Gupta M,Folsom AR,Kä

    更新日期:2014-03-01 00:00:00

  • Utility and limitations of long-term monitoring of atrial fibrillation using an implantable loop recorder.

    abstract::Atrial fibrillation (AF) is the most common cardiac arrhythmia diagnosed and treated in the world. The treatment of patients' symptoms as well as the prevention of stroke and heart failure is dependent on accurate detection and characterization of AF. A variety of electrocardiographic (ECG) monitoring techniques are b...

    journal_title:Heart rhythm

    pub_type: 杂志文章,评审

    doi:10.1016/j.hrthm.2017.09.009

    authors: Lee R,Mittal S

    更新日期:2018-02-01 00:00:00

  • Clinical and electrocardiographic features of complete heart block after blunt cardiac injury: A systematic review of the literature.

    abstract::The underlying mechanisms and temporal course of complete heart block (CHB) after blunt cardiac injuries (BCIs) are poorly understood, and a systematic analysis of available data is lacking. In this systematic review, PubMed was searched for publications of reported cases of CHB-BCI analyzing clinical findings, electr...

    journal_title:Heart rhythm

    pub_type: 杂志文章,评审

    doi:10.1016/j.hrthm.2017.05.040

    authors: Ali H,Furlanello F,Lupo P,Foresti S,De Ambroggi G,Epicoco G,Semprini L,Fundaliotis A,Cappato R

    更新日期:2017-10-01 00:00:00

  • Right bundle branch block-type wide QRS complex tachycardia with a reversed R/S complex in lead V6: Development and validation of electrocardiographic differentiation criteria.

    abstract:BACKGROUND:Differentiation of supraventricular tachycardia (SVT) with a right bundle branch block (RBBB) pattern from ventricular tachycardia (VT) is difficult, particularly when the R/S ratio in lead V6 is below 1.0. OBJECTIVE:We sought to investigate the electrocardiographic criteria for distinguishing between these...

    journal_title:Heart rhythm

    pub_type: 杂志文章

    doi:10.1016/j.hrthm.2020.08.023

    authors: Kim M,Kwon CH,Lee JH,Hwang KW,Choi HO,Kim YG,Lee KN,Ahn J,Park HS,Nam GB

    更新日期:2020-09-11 00:00:00

  • Anatomic insights for catheter ablation of ventricular tachycardia.

    abstract::Safe maneuvering of catheters in and around the ventricles, and ablations for ventricular tachycardia, require knowledge of the anatomy of the cardiac and extracardiac structures. This review emphasises the three-dimensional spatial relationships between the right and left ventricles and highlights the important extra...

    journal_title:Heart rhythm

    pub_type: 杂志文章,评审

    doi:10.1016/j.hrthm.2009.02.008

    authors: Ho SY

    更新日期:2009-08-01 00:00:00

  • Initial impedance decrease as an indicator of good catheter contact: insights from radiofrequency ablation with force sensing catheters.

    abstract:BACKGROUND:Good catheter-tissue contact force (CF) is critical for transmural and durable lesion formation during radiofrequency (RF) ablation but is difficult to assess in clinical practice. Tissue heating during RF application results in an impedance decrease at the catheter tip. OBJECTIVE:The purpose of this study ...

    journal_title:Heart rhythm

    pub_type: 杂志文章

    doi:10.1016/j.hrthm.2013.10.048

    authors: Reichlin T,Knecht S,Lane C,Kühne M,Nof E,Chopra N,Tadros TM,Reddy VY,Schaer B,John RM,Osswald S,Stevenson WG,Sticherling C,Michaud GF

    更新日期:2014-02-01 00:00:00

  • Electrophysiologic and clinical consequences of linear catheter ablation to transect the anterior left atrium in patients with atrial fibrillation.

    abstract:OBJECTIVES:To evaluate the feasibility and outcome of ablation to transect the anterior left atrium (LA) in patients with atrial fibrillation (AF). BACKGROUND:While the Maze procedure is effective in maintaining sinus rhythm in patients with AF, it is associated with significant morbidity. This prospective clinical st...

    journal_title:Heart rhythm

    pub_type: 杂志文章

    doi:10.1016/j.hrthm.2004.03.072

    authors: Sanders P,Jaïs P,Hocini M,Hsu LF,Scavée C,Sacher F,Rotter M,Takahashi Y,Pasquié JL,Shah DC,Garrigue S,Clémenty J,Haïssaguerre M

    更新日期:2004-07-01 00:00:00