Abstract:
INTRODUCTION:A novel magnetic navigation system allows remote guidance of floppy radiofrequency (RF) ablation catheters. We evaluated the feasibility of mapping and ablation of left-sided accessory pathways (APs) using the retrograde transaortic approach with this system. This might open the gate to retrograde ablation of left atrial arrhythmias. METHODS AND RESULTS:Twenty consecutive patients were included. A Helios II was used in five and in 15 a Celsius RMT RF catheter with higher magnetic mass and different flexibility was used. Mapping and ablation were attempted. The learning curve was analyzed. Ablation was acutely successful in 60% of the patients using the Helios II and in 80% using the Celsius RMT. Median procedure time was 158 minutes, with median patient and physician fluoroscopy times of 26 and 4 minutes. In the last 10 patients, procedure times became significantly shorter (median 122 minutes, only Celsius RMT catheters) and standard catheters had to be used only twice. No complications occurred. CONCLUSIONS:Remote retrograde transaortic RF ablation of left-sided APs is feasible, safe, and reduces the physician's fluoroscopy exposure. There is a very steep initial learning curve, with the success rate increasing from 50% in the first 10 cases to 80% in the last 10 cases. Different catheter configurations may influence the outcome.
journal_name
J Cardiovasc Electrophysioljournal_title
Journal of cardiovascular electrophysiologyauthors
Thornton AS,Rivero-Ayerza M,Knops P,Jordaens LJdoi
10.1111/j.1540-8167.2007.00783.xsubject
Has Abstractpub_date
2007-05-01 00:00:00pages
467-72issue
5eissn
1045-3873issn
1540-8167pii
JCE783journal_volume
18pub_type
临床试验,杂志文章abstract:INTRODUCTION:Idiopathic left ventricular tachycardia typically has a right bundle branch block configuration. The purpose of this case report is to demonstrate that idiopathic ventricular tachycardia arising in or near the left posterior fascicle also may have a left bundle branch block configuration. METHODS AND RESU...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 杂志文章
doi:10.1111/j.1540-8167.1997.tb00810.x
更新日期:1997-04-01 00:00:00
abstract:INTRODUCTION:Atrial arrhythmias, including atrial flutter, are common in orthotopic heart transplant recipients. However, only a small number of individual case reports describe the electrical circuit and catheter ablation of atrial flutter after heart transplantation. METHODS AND RESULTS:Detailed electrophysiologic e...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 杂志文章
doi:10.1046/j.1540-8167.2004.04440.x
更新日期:2004-12-01 00:00:00
abstract:BACKGROUND:The value of signal-averaged ECG (SAECG) in the risk stratification of Chagas disease (ChD), a potentially lethal illness prevalent in Latin America, remains controversial. The aim of this prospective longitudinal study was to determine the prognostic value of SAECG in ChD, using multivariate models with oth...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 杂志文章
doi:10.1111/j.1540-8167.2007.01088.x
更新日期:2008-05-01 00:00:00
abstract:INTRODUCTION:Bipolar voltage criteria to delineate left atrial (LA) scar have been derived using point-by-point (PBP) contact electroanatomical mapping. It remains unclear how PBP-derived LA scar correlates with multielectrode fast automated mapping (ME-FAM) derived scar. We aimed to correlate scar and bipolar voltages...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 杂志文章
doi:10.1111/jce.13151
更新日期:2017-03-01 00:00:00
abstract:BACKGROUND:The prevalence and predictors of left atrial appendage thrombus (LAAT) in patients with non-valvular atrial fibrillation (AF) who have been treated with non-vitamin K antagonist oral anticoagulants (NOACs) are not well defined. We aimed to assess the occurrence and predictors of LAAT on transesophageal echoc...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 杂志文章
doi:10.1111/jce.14589
更新日期:2020-08-01 00:00:00
abstract:INTRODUCTION:Data on long-term follow-up (LTFU) after interventional closure of the left atrial appendage (LAAC) in patients with nonvalvular atrial fibrillation (AF) are scarce. We sought to determine the outcome of patients after LAAC with the first generation device. METHODS AND RESULTS:The Cardioangiologisches Cen...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 杂志文章
doi:10.1111/jce.12704
更新日期:2015-08-01 00:00:00
abstract:BACKGROUND:Data comparing dabigatran with rivaroxaban regarding the resolution of left atrial/left atrial appendage (LA/LAA) thrombus in patients with nonvalvular atrial fibrillation (AF) are scarce. This study aimed to compare the efficacy and safety of dabigatran vs rivaroxaban regarding the resolution of LA/LAA thro...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 杂志文章
doi:10.1111/jce.14365
更新日期:2020-03-01 00:00:00
abstract::A 28-year-old man presented with progressive fatigue. Physical examination and ECG revealed severe sinus bradycardia. Echocardiography showed features of noncompaction cardiomyopathy and moderate aortic valve regurgitation. We hypothesized that the chronic volume overload exaggerated by prolonged diastole due to the b...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 杂志文章
doi:10.1111/j.1540-8167.2009.01704.x
更新日期:2010-07-01 00:00:00
abstract:INTRODUCTION:Bileaflet mitral valve prolapse (BiMVP) is common among survivors of otherwise unexplained sudden cardiac death, but prognostic implications of BiMVP are unknown. This study evaluated whether patients with BiMVP are at higher risk for ventricular dysrhythmias, ICD placement, or death compared to controls w...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 杂志文章
doi:10.1111/jce.12914
更新日期:2016-04-01 00:00:00
abstract::It is well established that impulse propagation in cardiac tissue is determined by the interaction between active membrane properties and the passive electrical characteristics of the network formed by individual myocytes. In the past, the intricate microarchitecture of intact cardiac tissue and the limited spatial re...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 杂志文章,评审
doi:10.1111/j.1540-8167.1995.tb00428.x
更新日期:1995-07-01 00:00:00
abstract::When an implanted device is infected, complete explantation of the device system, including lead extraction, is usually required. Superficial problems with wound healing may be managed more conservatively, but distinguishing between a surface process and deeper infection can pose a clinical challenge. We present a cas...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 杂志文章
doi:10.1111/j.1540-8167.2011.02224.x
更新日期:2012-03-01 00:00:00
abstract:INTRODUCTION:Beta-blockers are widely used to prevent the lethal cardiac events associated with the long QT syndrome (LQTS), especially in KCNQ1-related LQTS (LQT1) patients. Some LQT1 patients, however, are refractory to this therapy. METHODS AND RESULTS:Eighteen symptomatic LQTS patients (12 families) were genetical...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 杂志文章
doi:10.1046/j.1540-8167.2004.03212.x
更新日期:2004-02-01 00:00:00
abstract:INTRODUCTION:Repolarization dynamics, reflecting adaptation of QT to changing heart rate, is considered a marker of unfavorable prognosis in patients with heart diseases. We aimed to evaluate the prognostic value of QT/RR slope in predicting total mortality (TM) and sudden death (SD) in patients with congestive heart f...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 杂志文章
doi:10.1111/j.1540-8167.2008.01210.x
更新日期:2008-10-01 00:00:00
abstract:INTRODUCTION:The stability of implantable cardiac defibrillation lead impedance subsequent to implantation has not been reported and may have important clinical implications. The objective was to characterize the incidence and degree of impedance changes occurring after implantation of defibrillation lead systems. MET...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 杂志文章
doi:10.1111/j.1540-8167.1996.tb00577.x
更新日期:1996-08-01 00:00:00
abstract:INTRODUCTION:accurate selection of patients for vasovagal syncope studies requires strong risk stratification and knowledge of the natural history of syncope. We aimed to test the hypothesis that recent history of vasovagal syncope compared to distant history better predicts subsequent recurrence of syncope. METHODS A...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 杂志文章,随机对照试验
doi:10.1111/j.1540-8167.2010.01848.x
更新日期:2010-12-01 00:00:00
abstract::The mouse has become the principal animal model for studying biologic processes in mammals. Major advances in transgene and gene targeting technology enabled manipulation of the mouse genome in a predictable fashion. Mutant mouse strains provide important insights into the molecular mechanisms underlying normal and di...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 杂志文章,评审
doi:10.1111/j.1540-8167.2000.tb01806.x
更新日期:2000-03-01 00:00:00
abstract:INTRODUCTION:A male patient with an atriofascicular pathway underwent catheter ablation of the atriofascicular pathway during atrial fibrillation. METHODS AND RESULTS:The patient had preexcited atrial fibrillation both clinically and repeatedly during electrophysiologic study. A preexcited tachycardia with a 1:1 AV re...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 杂志文章
doi:10.1111/j.1540-8167.1994.tb01123.x
更新日期:1994-10-01 00:00:00
abstract:INTRODUCTION:Oral anticoagulation therapy reduces significantly the risk of thromboembolism in patients with atrial fibrillation. However, effective oral anticoagulation therapy is not feasible in all patients. The interventional occlusion of the left atrial appendage may reduce the risk of thromboembolism in the latte...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 临床试验,杂志文章
doi:10.1046/j.1540-8167.14.s9.11.x
更新日期:2003-09-01 00:00:00
abstract:INTRODUCTION:In vitro studies and ambulatory ECG recordings from the MERLIN TIMI-36 clinical trial suggest that the novel antianginal agent ranolazine may have the potential to suppress atrial arrhythmias. However, there are no reports of effects of ranolazine on atrial electrophysiologic properties in large intact ani...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 杂志文章
doi:10.1111/j.1540-8167.2009.01437.x
更新日期:2009-07-01 00:00:00
abstract:INTRODUCTION:Pacing is believed to prevent atrial fibrillation by reducing atrial activation time. Exact correlation between P wave duration (PWD) on surface ECG and endocardial atrial activation time is still unexplored. METHODS AND RESULTS:In 15 patients without structural heart disease (9 women, age 45 +/- 14 years...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 杂志文章
doi:10.1046/j.1540-8167.2002.01240.x
更新日期:2002-12-01 00:00:00
abstract::A 31-year-old woman with tricuspid atresia and a palliative Waterston shunt presented with intractable poorly tolerated supraventricular tachycardia. Electrophysiologic evaluation was consistent with AV nodal reentrant tachycardia. The fast pathway region was mapped electroanatomically during tachycardia and with cons...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 杂志文章
doi:10.1046/j.1540-8167.2004.03546.x
更新日期:2004-06-01 00:00:00
abstract:INTRODUCTION:Permanent right ventricular (RV) pacing leads have been traditionally implanted in the right ventricular apex (RVA). Nowadays, some deleterious effects of RVA pacing have been recognized. The aim of this study was to evaluate the effect of different sites of RV pacing in patients with permanent atrial fibr...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 杂志文章
doi:10.1111/j.1540-8167.2007.00914.x
更新日期:2007-09-01 00:00:00
abstract:INTRODUCTION:Patients with bradycardia requiring permanent pacing frequently suffer from additional atrial tachyarrhythmias (ATs). This study evaluated the safety and efficacy of atrial antitachycardia pacing (ATP) and the performance of pacing for AT prevention implemented into a new pacemaker. METHODS AND RESULTS:In...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 临床试验,杂志文章,多中心研究
doi:10.1046/j.1540-8167.2001.01121.x
更新日期:2001-10-01 00:00:00
abstract:INTRODUCTION:Cerebral thromboembolic event (CTE) is a possible complication of pulmonary vein antrum isolation (PVAI). The objective of this study was to report long-term functional and neurocognitive recovery in patients who had a CTE during or within 48 hours of catheter ablation. METHODS AND RESULTS:We screened 3,0...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 杂志文章
doi:10.1111/j.1540-8167.2009.01650.x
更新日期:2010-04-01 00:00:00
abstract:INTRODUCTION:To explore the relationship between recurrence of atrial fibrillation (AF) and the autonomic nervous activity evaluated by heart rate variability (HRV) indices after radiofrequency catheter ablation (RFCA) in the early period. METHODS:We enrolled 102 patients with paroxysmal AF and tested the HRV indices ...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 杂志文章
doi:10.1111/jce.14448
更新日期:2020-06-01 00:00:00
abstract::The incidence of atrial fibrillation (AF) in Brugada syndrome (BrS) has been reported at between 9% and 53% by different series, but the true prevalence is unknown. However, AF may be the presenting feature in some patients. The underlying mechanisms for AF may be a combination of multiple factors, genetic or acquired...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 杂志文章,评审
doi:10.1111/jce.14361
更新日期:2020-04-01 00:00:00
abstract:INTRODUCTION:Two randomized trials (Multicenter Automatic Defibrillator Implantation Trial [MADIT] and Multicenter Unsustained Tachycardia Trial [MUSTT]) suggest that implantable cardioverter defibrillator (ICD) placement is associated with improved survival in patients with coronary artery disease, depressed left vent...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 杂志文章
doi:10.1046/j.1540-8167.2002.00342.x
更新日期:2002-04-01 00:00:00
abstract::Epicardial RFA to Achieve Electrical PV Isolation. During catheter ablation of atrial fibrillation, ablation within the pulmonary veins is undesirable due to the risk of pulmonary venous stenosis and the possibility of leaving residual cuffs of arrhythmogenic tissue proximal to the ablation lesion set. An extra-ostial...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 杂志文章
doi:10.1046/j.1540-8167.2003.03049.x
更新日期:2003-06-01 00:00:00
abstract:INTRODUCTION:The difficult catheter orientation and navigation associated with conventional technology and mono-/multiplane fluoroscopy may complicate ablation procedures of atrial tachycardias. A new three-dimensional catheter technology for electroanatomical mapping of the right atrium and ablation of ectopic atrial ...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 杂志文章
doi:10.1111/j.1540-8167.1997.tb01029.x
更新日期:1997-12-01 00:00:00
abstract:INTRODUCTION:The incidence of spontaneous transition of 2:1 AV block to 1:1 AV conduction during AV nodal reentrant tachycardia has not been well reported. Among previous studies, controversy also existed about the site of the 2:1 AV block during AV nodal reentrant tachycardia. METHODS AND RESULTS:In patients with 2:1...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 临床试验,杂志文章
doi:10.1046/j.1540-8167.2003.03198.x
更新日期:2003-12-01 00:00:00