Development of a novel computer-aided diagnosis system for automatic discrimination of malignant from benign solitary pulmonary nodules on thin-section dynamic computed tomography.

Abstract:

OBJECTIVES:As an application of the computer-aided diagnosis of solitary pulmonary nodules (SPNs), 3-dimensional contrast-enhanced (CE) dynamic helical computed tomography (HCT) was performed to evaluate temporal changes in the internal structure of nodules to differentiate between benign nodules (BNs) and malignant nodules (MNs). METHODS:There were 62 SPNs (35 MNs and 27 BNs) included in this study. Scanning (2-mm collimation) was performed before and 2 and 4 minutes after CE dynamic HCT. The CT data were sent to a computer, and the pixels inside the nodule were characterized in terms of 3 parameters (attenuation, shape index, and curvedness value). RESULTS:Based on the CT data at 4 (MN: 1.81-27.1, BN: -42.8 to -3.29) minutes after CE-dynamic HCT, a score of 0 or higher can be assumed to indicate an MN. CONCLUSIONS:Three-dimensional computer-aided diagnosis of the internal structure of SPNs using CE dynamic HCT was found to be effective for differentiating between BNs and MNs.

journal_name

J Comput Assist Tomogr

authors

Mori K,Niki N,Kondo T,Kamiyama Y,Kodama T,Kawada Y,Moriyama N

doi

10.1097/01.rct.0000155668.28514.01

keywords:

subject

Has Abstract

pub_date

2005-03-01 00:00:00

pages

215-22

issue

2

eissn

0363-8715

issn

1532-3145

pii

00004728-200503000-00012

journal_volume

29

pub_type

杂志文章
  • Hemolymphangiomatosis of the spleen: imaging features.

    abstract::Hemolymphangiomatosis is an extremely rare entity that has never been described in the diffuse form. Its main pathologic feature is proliferation of lymphatic and vascular cells inducing interstitial and hematic lakes and then splenomegaly. We report a complete imaging study, including magnetic resonance (MR) imaging,...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/01.rct.0000178713.40170.73

    authors: Santoro L,Santini V,Lollo SD,Valeri A,Colagrande S

    更新日期:2005-11-01 00:00:00

  • Computed tomography with intraperitoneal contrast medium for localization of peritoneal dialysis leaks.

    abstract::Dialysate leakage into subcutaneous tissues occurs not uncommonly in patients on continuous ambulatory peritoneal dialysis. When the leakage site cannot be localized clinically, CT with intraperitoneal contrast medium administration may localize the site. We report our experience with three cases in which this techniq...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-198703000-00016

    authors: Brown DL,Johnson JB Jr,Kraus AP Jr,Duke RA,Barrett MR

    更新日期:1987-03-01 00:00:00

  • A knowledge-based approach to deconvolve the water component in in vivo proton MR spectroscopy.

    abstract:OBJECTIVE:The water component dominates in in vivo proton (1H) spectroscopy. This consists of a prominent central peak with large "wings," and consequently metabolites that lie on the "wings" become difficult to quantitate. A method has been developed to deconvolve the water component in in vivo 1H spectroscopy, hence ...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-199509000-00030

    authors: Saeed N

    更新日期:1995-09-01 00:00:00

  • Use of nutritional support formula as a gastrointestinal contrast agent for MRI.

    abstract::The objective of this study was to evaluate the potential utility of a nutritional support formula to serve as a practical means of enhancing the gastrointestinal tract on abdominal MR images. Nutritional support formula (Ensure Plus) was administered to 29 patients prior to abdominal MRI. Standard T1-weighted and T2-...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-199211000-00015

    authors: Mirowitz SA,Susman N

    更新日期:1992-11-01 00:00:00

  • Assessment of the tracer delay effect in whole-brain computed tomography perfusion: results in patients without known neuroanatomic abnormalities.

    abstract:OBJECTIVE:Whole-brain computed tomography perfusion (CTP) data sets generated by tracer delay-insensitive singular value decomposition plus (SVD+) and standard singular value decomposition (sSVD) deconvolution algorithms were evaluated to quantify relatedness and discrepancies in CTP results. METHODS:Twenty females wi...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0b013e31828004bb

    authors: Hanson EH,Roach CJ,Day KJ,Peters KR,Bradley WG Jr,Ghosh K,Patton PW,McMurray RC,Orrison WW Jr

    更新日期:2013-03-01 00:00:00

  • MR appearance of umbilical endometriosis.

    abstract:OBJECTIVE:We describe the MR appearance of endometriosis involving the umbilicus in two patients. One patient had a history of laparoscopy performed through the umbilicus; the other had an umbilical hernia. MATERIALS AND METHODS:MR imaging was performed using both a body coil and a spine coil (with the patient lying p...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-199403000-00019

    authors: Yu CY,Perez-Reyes M,Brown JJ,Borrello JA

    更新日期:1994-03-01 00:00:00

  • Splenic infarction complicating pediatric liver transplantation: incidence and CT appearance.

    abstract::In children it is often necessary to ligate the splenic artery and the main collateral supply to the spleen during liver transplantation. The complication of splenic infarction has been observed on postoperative CT in such patients. The purpose of our study was to determine the incidence and CT appearance of splenic i...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-199005000-00007

    authors: Lehar SC,Zajko AB,Koneru B,Stevenson W,Sumkin J

    更新日期:1990-05-01 00:00:00

  • Small aorta: CT detection and clinical significance.

    abstract::Small aortas were documented by CT in six patients, 16-34 years old. The diameter of these aortas measured at the level of 1 cm below the orifice of the superior mesenteric artery ranged from 10 to 12 mm, much smaller than the mean of 17 mm obtained from 20 subjects, 16-20 years old. Such small aortas are usually prod...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:

    authors: Shin MS,Berland LL,Ho KJ

    更新日期:1990-01-01 00:00:00

  • Direct longitudinal computed tomography of the forearm.

    abstract::A method is outlined for obtaining direct longitudinal computed tomograms of the forearm using a conventional total body scanner. A case is described in which longitudinal scanning helped define a soft tissue tumor of the forearm and thereby assisted in surgical planning. ...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-198102000-00029

    authors: Nesbit D,Levine E,Neff JR

    更新日期:1981-02-01 00:00:00

  • Additional coronal images using low-milliamperage multidetector-row computed tomography: effectiveness in the diagnosis of bronchiectasis.

    abstract:PURPOSE:The aim of our study was to evaluate the effectiveness of additional coronal images using low-milliamperage multidetector-row computed tomography (CT) in the diagnosis of bronchiectasis. METHODS:Helical volumetric CT scans (120 kVp, 70 mA, 2.5-mm collimation, table speed of 15 mm/s, table rotation time of 1 se...

    journal_title:Journal of computer assisted tomography

    pub_type: 临床试验,杂志文章

    doi:10.1097/00004728-200307000-00006

    authors: Sung YM,Lee KS,Yi CA,Yoon YC,Kim TS,Kim S

    更新日期:2003-07-01 00:00:00

  • Computed tomography of renal lymphoma with ultrasound correlation.

    abstract::The computed tomography (CT) and ultrasound findings in 18 patients (35 kidneys) with non-Hodgkin lymphoma involving the kidneys are presented. Renal involvement was bilateral in 13 patients. The most common presentation was that of multiple intraparenchymal nodules (15 kidneys). Other types of involvement included di...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-198304000-00007

    authors: Heiken JP,Gold RP,Schnur MJ,King DL,Bashist B,Glazer HS

    更新日期:1983-04-01 00:00:00

  • In Vivo Analysis of Urinary Stones With Dual-Energy Computed Tomography.

    abstract:OBJECTIVE:Formation mechanisms and treatment of the urinary stones are different, depending on their chemical structure. Therefore, determining the stone type plays a key role in planning treatment and preventive measures. Computed tomography (CT), with the use of dual-energy technology in recent years, has made it pos...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0000000000000831

    authors: Erdogan H,Temizoz O,Koplay M,Ozturk B

    更新日期:2019-03-01 00:00:00

  • Prevalence and etiology of focal liver opacification in patients with superior vena cava obstruction.

    abstract:OBJECTIVE:This study aimed to assess the prevalence and etiologies of focal liver opacification (FLO) in the setting of superior vena cava (SVC) obstruction. METHODS:An archival search using key words to identify patients with SVC obstruction or severe narrowing and who had computed tomographic scans with intravenous ...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0b013e31829950a1

    authors: Siegel Y,Schallert E

    更新日期:2013-09-01 00:00:00

  • Radiological Evaluation of Artificial Stone Silicosis Outbreak: Emphasizing Findings in Lung Transplant Recipients.

    abstract:OBJECTIVE:The aim of this study was to describe the computed tomography (CT) findings and correlate pulmonary function tests (PFTs) of silicosis patients with emphasis on the findings in lung transplantation (LTX) recipients. METHODS:We studied the chest CT scans from 82 marble workers exposed to artificial stone dust...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0000000000000454

    authors: Grubstein A,Shtraichman O,Fireman E,Bachar GN,Noach-Ophir N,Kramer MR

    更新日期:2016-11-01 00:00:00

  • Inhomogeneity correction for brain magnetic resonance images by rank leveling.

    abstract:OBJECTIVE:A postprocessing method of rank filtering inhomogeneity correction using nonlinear rank filtering of magnetic resonance imaging (MRI) scans is described. The method addresses some of the problems of homomorphic unsharp masking (HUM) using mean or median filtering. METHODS:Maximum rank filtering was used to e...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/01.rct.0000175498.57083.80

    authors: Chen J,Reutens DC

    更新日期:2005-09-01 00:00:00

  • Validation of a new method for stereotactic localization using MR imaging.

    abstract::Magnetic resonance is recognized as potentially the best imaging procedure for localization in stereotactic neurosurgery. However, special difficulties necessitate specific adaptation to localize targets in the stereotactic frame. We developed a new method for stereotactic localization. The MR studies were performed u...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-199103000-00020

    authors: Rousseau J,Clarysse P,Blond S,Gibon D,Vasseur C,Marchandise X

    更新日期:1991-03-01 00:00:00

  • Lumbar artery pseudoaneurysm: CT demonstration.

    abstract::A psoas mass in a patient with a history of penetrating trauma to the area was demonstrated by computed tomography (CT) to represent a lumbar artery pseudoaneurysm surrounded by hematoma. This report emphasizes the importance of recognizing the anatomic position of the lumbar arteries on CT images and considering the ...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-198406000-00044

    authors: Hulnick DH,Naidich DP,Balthazar EJ,Megibow AJ,Bosniak MA

    更新日期:1984-06-01 00:00:00

  • Barium sulfate for abdominal computer assisted tomography.

    abstract::A low density barium sulfate mixture has been specially formulated and routinely used in over 800 abdominal computer assisted tomography scans over the past 3 years. ...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-198008000-00038

    authors: Hatfield KD,Segal SD,Tait K

    更新日期:1980-08-01 00:00:00

  • Optimal contrast of computed tomography portal venography using dual-energy computed tomography.

    abstract:OBJECTIVE:The objective of this study was to evaluate image quality of computed tomography (CT) portal venography using nonlinear blending technique of dual-energy CT (DECT) in portal phase. METHODS:Fifty patients underwent contrast-enhanced abdominal scan with DECT at portal venous phase. The images of 2 energy level...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0b013e31827cd656

    authors: Wang Q,Shi G,Liu X,Wu R,Wang S

    更新日期:2013-03-01 00:00:00

  • Accuracy and predictive value of coronary computed tomography angiography for the detection of obstructive coronary heart disease in patients with an Agatston calcium score above 400.

    abstract:PURPOSE:We assessed the accuracy of coronary computed tomography angiography (CTA) in patients with an Agatston calcium score (ACS) of greater than 400 by comparing it with invasive coronary angiography (ICA), and we evaluated the predictive value of CTA for obstructive coronary heart disease (CHD) compared with tradit...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0b013e318282d61c

    authors: Ahn SJ,Kang DK,Sun JS,Yoon MH

    更新日期:2013-05-01 00:00:00

  • Localization of scanning level in computed tomography of the spine.

    abstract::A simple method for identifying the scanning level in computed tomography (CT) of the spine is described. The method involves exposing a lead lattice grid on a conventional X-ray film and taking a conventional spine film with aluminum markers on the patient's back. The film showing the grid and the markers on the pati...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-197904000-00029

    authors: Dossetor RS,Veiga-Pires JA,Kaiser M

    更新日期:1979-04-01 00:00:00

  • CT demonstration of gastropancreatic fistula due to penetrating gastric ulcer.

    abstract::We report a patient with gas in the pancreatic duct due to a gastropancreatic fistula resulting from gastric ulcer. No mass or pseudocyst was demonstrated. This entity should be considered when patients with gas in the pancreas are encountered. ...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-198707000-00031

    authors: Hughes JJ,Blunck CE

    更新日期:1987-07-01 00:00:00

  • MR imaging of the hilum and mediastinum: effects of cardiac gating.

    abstract::The effect of cardiac gating (CG) on the diagnostic quality of magnetic resonance images of the hilum and mediastinum was evaluated by comparing gated with nongated scans in 20 patients. The advantages of CG varied depending on the regions and structures under study and the presence and extent of disease. In general, ...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-198511000-00013

    authors: Westcott JL,Henschke CI,Berkmen Y

    更新日期:1985-11-01 00:00:00

  • H(2) (15)0 positron emission tomography validation of semiquantitative prostate blood flow determined by double-echo dynamic MRI: a preliminary study.

    abstract:PURPOSE:Information regarding prostate blood flow as determined by positron emission tomography (PET) with H 0 may provide useful information about tumor diagnosis; however, PET requires a cyclotron for the production of an extremely short half-life (2 minutes) tracer. Therefore, the aim of this study was to propose a ...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-200207000-00005

    authors: Muramoto S,Uematsu H,Sadato N,Tsuchida T,Matsuda T,Hatabu H,Yonekura Y,Itoh H

    更新日期:2002-07-01 00:00:00

  • Assessment of Myometrial Invasion in Premenopausal Grade 1 Endometrial Carcinoma: Is Magnetic Resonance Imaging a Reliable Tool in Selecting Patients for Fertility-Preserving Therapy?

    abstract:OBJECTIVES:The aim of this study was to evaluate the diagnostic ability of magnetic resonance imaging (MRI) in premenopausal women with G1 endometrial carcinoma. METHODS:Twenty-six patients underwent T2W, diffusion weighted, and dynamic contrast-enhanced 3-T MRI. The degree of myometrial invasion was pathologically cl...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0000000000000689

    authors: Sakane M,Hori M,Onishi H,Tsuboyama T,Ota T,Tatsumi M,Ueda Y,Kimura T,Kimura T,Tomiyama N

    更新日期:2018-05-01 00:00:00

  • Use of high-pitch dual-source computed tomography of the abdomen and pelvis to markedly reduce scan time: clinical feasibility study.

    abstract:BACKGROUND:Increasing image pitch in computed tomographic (CT) imaging is a method through which scan time can be reduced, which can reduce motion artifacts. In this study, we assess the clinical feasibility of ultrahigh-pitch CT imaging made possible by dual-source CT. METHODS:Image pitch, total scan time, and image ...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0b013e31821a02c8

    authors: Hardie AD,Mayes N,Boulter DJ

    更新日期:2011-05-01 00:00:00

  • MR imaging of cerebral abnormalities in utero.

    abstract::In view of the lack of ionizing radiation, ability to image in a variety of planes, and high contrast resolution, magnetic resonance (MR) imaging may have a role in obstetrical management. Three fetuses with severe cerebral abnormalities were studied by MR in utero. The findings were correlated with ultrasound examina...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-198412000-00003

    authors: Thickman D,Mintz M,Mennuti M,Kressel HY

    更新日期:1984-12-01 00:00:00

  • MR imaging with surface coils in primary hyperparathyroidism.

    abstract::The use of magnetic resonance (MR) to preoperatively evaluate patients with primary hyperparathyroidism was assessed using a 1.5 T system and surface coil reception. Twenty-five patients with primary hyperparathyroidism were studied before surgical exploration. Axial images, 5 mm thick, were obtained from the thyroid ...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-198709000-00023

    authors: Kier R,Blinder RA,Herfkens RJ,Leight GS,Spritzer CE,Carroll BA

    更新日期:1987-09-01 00:00:00

  • Retrodural cysts bridging a bilateral lumbar spondylolysis: a report of two symptomatic cases.

    abstract::We report the MR features in two patients presenting with symptomatic thecal impingement by posterior epidural cysts linking a bilateral lumbar spondylolysis. Large fluid-filled channels bridging the ruptured partes interarticulares were present in spite of the absence of significant arthritic changes within the adjac...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-199907000-00008

    authors: Duprez T,Mailleux P,Bodart A,Coulier B,Malghem J,Maldague B

    更新日期:1999-07-01 00:00:00

  • Normalized accurate measurement of longitudinal brain change.

    abstract:PURPOSE:Quantitative measurement of change in brain size and shape (e.g., to estimate atrophy) is an important current area of research. New methods of change analysis attempt to improve robustness, accuracy, and extent of automation. A fully automated method has been developed that achieves high estimation accuracy. ...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-200105000-00022

    authors: Smith SM,De Stefano N,Jenkinson M,Matthews PM

    更新日期:2001-05-01 00:00:00