Apatite formation on dental ceramics modified by a bioactive glass.

Abstract:

:Restorative dental materials are considered biocompatible without exhibiting any bioactive behaviour. The aim of this study was the investigation of surface structure changes on conventional dental ceramics used in metal-ceramic restorations modified by a bioactive glass, after immersion in SBF for various time periods. Bioactive glass powder was mixed with porcelain powder with three different weight ratios: 1:1, 1:2, and 2:1. The two powders were mixed with porcelain modelling liquid and the mixture was transferred and spread on the surface of pre-fabricated ceramic disks. Coated ceramic specimens after being exposed to a specific thermal cycle as it is recommended for dental ceramics were soaked in Simulated Body Fluid (SBF) at 37 degrees C for various periods of time. After soaking, specimens were studied using Fourier Transform Infrared Spectroscopy (FTIR), Scanning Electron Microscopy (SEM) and Energy Dispersive Spectroscopy (EDS). Results revealed the development of a non-stoichiometric, biological apatite layer on their surface after exposure in SBF for several time periods. The onset of apatite-layer formation is directly dependent on the amount of bioglass in the coating and its thickness reduces within the specimens of the same bioactive glass-porcelain proportion with time, reaching an average thickness of 15 microm at the longest immersion time, for all the specimens.

journal_name

J Oral Rehabil

authors

Kontonasaki E,Papadopoulou L,Zorba T,Pavlidou E,Paraskevopoulos K,Koidis P

doi

10.1046/j.1365-2842.2003.01072.x

keywords:

subject

Has Abstract

pub_date

2003-09-01 00:00:00

pages

893-902

issue

9

eissn

0305-182X

issn

1365-2842

pii

1072

journal_volume

30

pub_type

杂志文章
  • Possible impact of inflammatory status on C-telopeptide pyridinoline cross-links of type I collagen and osteocalcin levels around oral implants with peri-implantitis: a controlled clinical trial.

    abstract::Detection of progression level of peri-implantitis may help in the prevention of oral implant failure. C-telopeptide pyridinoline crosslinks of Type I collagen (ICTP) and osteocalcin (OC) are specific markers of bone turnover and bone degradation. Determination of the ICTP and OC levels in the peri-implant sulcus flui...

    journal_title:Journal of oral rehabilitation

    pub_type: 杂志文章

    doi:10.1111/j.1365-2842.2008.01879.x

    authors: Tümer C,Aksoy Y,Güncü GN,Nohutcu RM,Kilinc K,Tözüm TF

    更新日期:2008-12-01 00:00:00

  • Determining the accuracy of stock and custom tray impression/casts.

    abstract::A study was conducted to evaluate the accuracy of casts made from stock tray and custom tray impressions using polysiloxane impression material. The results indicate that all casts distort but that impressions made from custom trays were more accurate and consistent in reproduction than were stock tray impressions. ...

    journal_title:Journal of oral rehabilitation

    pub_type: 杂志文章

    doi:10.1046/j.1365-2842.1998.00306.x

    authors: Millstein P,Maya A,Segura C

    更新日期:1998-08-01 00:00:00

  • Electromyographic activity in patients with temporomandibular disorders.

    abstract::Evaluation of masticatory muscle activity by surface electromyography (EMG) is a valuable tool for diagnosing dysfunction of the masticatory apparatus. However, controversy exists with regard to the usefulness of the EMG for patients with temporomandibular disorders (TMD). Forty patients with TMD were subjected to sur...

    journal_title:Journal of oral rehabilitation

    pub_type: 杂志文章

    doi:10.1046/j.1365-2842.2000.00571.x

    authors: Pinho JC,Caldas FM,Mora MJ,Santana-Penín U

    更新日期:2000-11-01 00:00:00

  • Attitudes, awareness and oral health-related quality of life in patients with diabetes.

    abstract::The purpose of this study was to assess the knowledge diabetic patients have of their risk for periodontal disease, their attitude towards oral health and their oral health-related quality of life (OHRQL). One hundred and one consecutive patients (age range 31-79 years) recruited from a diabetic outpatient clinic part...

    journal_title:Journal of oral rehabilitation

    pub_type: 杂志文章

    doi:10.1111/j.1365-2842.2007.01760.x

    authors: Allen EM,Ziada HM,O'Halloran D,Clerehugh V,Allen PF

    更新日期:2008-03-01 00:00:00

  • Interfacial ultramorphology of single-step adhesives: nanoleakage as a function of time.

    abstract::The aim of this study was to examine the effectiveness of single-step self-etching adhesives in preventing nanoleakage over a 90-day water-storage period, and analyse the ultramorphological characteristics of resin-dentin interfaces. Three single-step self-etching adhesives were evaluated: Adper Prompt L-Pop - LP (3M ...

    journal_title:Journal of oral rehabilitation

    pub_type: 杂志文章

    doi:10.1111/j.1365-2842.2006.01656.x

    authors: Reis AF,Bedran-Russo AK,Giannini M,Pereira PN

    更新日期:2007-03-01 00:00:00

  • A 10-year follow-up study of fixed metal ceramic prosthodontics.

    abstract::The aim of this retrospective study was to record patients' satisfaction with fixed metal ceramic bridges and crowns made by dental students and to evaluate the functioning and condition of the bridges and crowns clinically and radiologically. Out of the 60 patients treated at the Institute of Dentistry during 1984-85...

    journal_title:Journal of oral rehabilitation

    pub_type: 杂志文章

    doi:10.1046/j.1365-2842.1997.00554.x

    authors: Näpänkangas R,Salonen MA,Raustia AM

    更新日期:1997-10-01 00:00:00

  • Comparison of the dimensional stability of two waxes and two acrylic resin processing techniques in the production of complete dentures.

    abstract::Two base plate waxes and two denture processing techniques were independently compared for dimensional stability. Occlusion rims were constructed from extra hard and medium soft base plate waxes and teeth were set. Acrylic resin bases were processed by a trial packing technique, and a continuous injection system. Toot...

    journal_title:Journal of oral rehabilitation

    pub_type: 杂志文章

    doi:10.1111/j.1365-2842.1990.tb00002.x

    authors: Sykora O,Sutow EJ

    更新日期:1990-05-01 00:00:00

  • Surface characteristics of aesthetic restorative materials - an SEM study.

    abstract::To determine the degree of surface roughness of glass-ionomer cements (GICs) and polyacid-modified resin composite (PAMRC) after polishing and immersion in various foodstuffs. Three tooth-coloured restorative materials were used: a PAMRC (F2000), a conventional glass-ionomer cement (CGIC) (Fuji IX) and a resin-modifie...

    journal_title:Journal of oral rehabilitation

    pub_type: 杂志文章

    doi:10.1111/j.1365-2842.2006.01608.x

    authors: Bagheri R,Burrow MF,Tyas MJ

    更新日期:2007-01-01 00:00:00

  • Oral appliance therapy versus nasal continuous positive airway pressure in obstructive sleep apnoea syndrome: a randomised, placebo-controlled trial on self-reported symptoms of common sleep disorders and sleep-related problems.

    abstract::Obstructive sleep apnoea syndrome (OSAS) is associated with several sleep disorders and sleep-related problems. Therefore, the aim of this study was to compare the effects of a mandibular advancement device (MAD) with those of nasal continuous positive airway pressure (nCPAP) on self-reported symptoms of common sleep ...

    journal_title:Journal of oral rehabilitation

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/joor.12505

    authors: Nikolopoulou M,Byraki A,Ahlberg J,Heymans MW,Hamburger HL,De Lange J,Lobbezoo F,Aarab G

    更新日期:2017-06-01 00:00:00

  • Recent results concerning physiological tooth movement and anterior guidance.

    abstract::Physiological tooth movements during mandibular excursions with and without occlusion have been considered. Using electronic and pantographic techniques, anterior guidance and tooth movements during simulated mastication (without a bolus) were investigated. Investigations in the absence of occlusion showed that elasti...

    journal_title:Journal of oral rehabilitation

    pub_type: 杂志文章

    doi:10.1111/j.1365-2842.1981.tb00523.x

    authors: Siebert G

    更新日期:1981-11-01 00:00:00

  • Splinting osseointegrated implants and natural teeth in rehabilitation of partially edentulous patients. Part II: principles and applications.

    abstract::Lone standing splinted implant segments are accepted as optimal. However, in the treatment of partial edentulism, clinical reality often predicates the consideration of splinting teeth and implants due to variables of tooth/implant location and available bone support. This article presents a review on biomechanical as...

    journal_title:Journal of oral rehabilitation

    pub_type: 杂志文章,评审

    doi:10.1046/j.1365-2842.1998.00583.x

    authors: Laufer BZ,Gross M

    更新日期:1998-01-01 00:00:00

  • Removable prosthodontic services, including implant-supported overdentures, provided by dentists and denturists.

    abstract::The aim of this study was to evaluate the provision of removable prosthodontic services, including implant-supported overdentures, by dentists and denturists. A structured questionnaire was mailed to 474 randomly chosen dentists and 156 denturists registered to practise in New Zealand. Information was sought on the ra...

    journal_title:Journal of oral rehabilitation

    pub_type: 杂志文章

    doi:10.1111/j.1365-2842.2007.01797.x

    authors: Egan JG,Payne AG,Thomson WM

    更新日期:2008-04-01 00:00:00

  • Condylar displacements related to dynamic and static recordings of the comfortable zone.

    abstract::In a previous study it was found that the distance between the borders of the comfortable zone was considerably wider when the zone was recorded statically rather than dynamically. However, it was not reported how condylar displacements may be related to the zonal borders. Therefore, an attempt is made in the present ...

    journal_title:Journal of oral rehabilitation

    pub_type: 杂志文章

    doi:10.1111/j.1365-2842.1979.tb00398.x

    authors: Kato H,Fujii H,Stoltze K,Brill N

    更新日期:1979-01-01 00:00:00

  • Effects of a bleaching agent containing 35% carbamide peroxide on the immunolocalization of cyclin D and p16.

    abstract::The evidences that p16 and cyclin D alterations occur in the earlier stages of many human cancers and that its immunolocalization can be used to study the cell cycle regulation, coupled with the possibility that chronic use of carbamide peroxide would induce DNA damage and cell cycle alteration, prompted us to analyse...

    journal_title:Journal of oral rehabilitation

    pub_type: 杂志文章

    doi:10.1046/j.1365-2842.2002.00944.x

    authors: Gomez RS,de Castro Albuquerque R,Dutra RA,Vasconcellos WA,Reis DA,Gomez RS,Gomez MV

    更新日期:2002-09-01 00:00:00

  • Alleviation of acute dental pain from localised apical periodontitis: A prospective randomised study comparing two emergency treatment procedures.

    abstract:OBJECTIVE:To compare the outcomes of two emergency treatment procedures to alleviate pain from localised symptomatic apical periodontitis: complete chemo-mechanical disinfection (CMD) of the root canal system, or removal of necrotic tissue from the pulp chamber (RNT), that is without instrumentation of the root canals....

    journal_title:Journal of oral rehabilitation

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/joor.12730

    authors: Wolf E,Dragicevic M,Fuhrmann M

    更新日期:2019-02-01 00:00:00

  • Effect of age on salivary flow obtained under feeding and non-feeding conditions.

    abstract::Age, health status and disease treatments are thought to influence salivary flow. In this study, age effect on salivation was compared in non-feeding (at rest and during parafilm chewing) and feeding (during meat chewing) conditions for two groups of healthy subjects, 25 young subjects (mean age 27.4 years) and 20 old...

    journal_title:Journal of oral rehabilitation

    pub_type: 杂志文章

    doi:10.1111/j.1365-2842.2004.01253.x

    authors: Bourdiol P,Mioche L,Monier S

    更新日期:2004-05-01 00:00:00

  • Subjective food intake ability in relation to maximal bite force among Korean adults.

    abstract::This study examined the relationship between the subjective food intake of 30 food types and their objective bite force to identify the key food items within the 30 food types to achieve a greater depth of masticatory function in Korean adults. A sample of 308 (112 males and 196 females) adults over the age of 20 (ave...

    journal_title:Journal of oral rehabilitation

    pub_type: 杂志文章,多中心研究

    doi:10.1111/j.1365-2842.2008.01924.x

    authors: Kim BI,Jeong SH,Chung KH,Cho YK,Kwon HK,Choi CH

    更新日期:2009-03-01 00:00:00

  • Effect of denture base materials on mRNA expression of the adhesion-associated genes from the Streptococcus mutans biofilms.

    abstract::Dental caries is one of the most important reasons for the failure of removable partial denture. The adhesion-associated genes of Streptococcus mutans, such as gtfBCD, ftf and gbpB, might play an important role in bacterial adhesion to denture base materials. Therefore, the aim of this study was to investigate the inf...

    journal_title:Journal of oral rehabilitation

    pub_type: 杂志文章

    doi:10.1111/j.1365-2842.2009.02004.x

    authors: Dong C,Zhang FQ

    更新日期:2009-12-01 00:00:00

  • Surgical and prosthetic reconsiderations in patients with maxillectomy.

    abstract::The purpose of this study was to establish and evaluate new possibilities for rehabilitation of patients with obturator prosthesis who had undergone partial or total maxillectomy because of tumour ablation surgery. Eleven patients with maxillary defects were reconstructed with a computer-aided design/computer-aided ma...

    journal_title:Journal of oral rehabilitation

    pub_type: 杂志文章

    doi:10.1111/j.1365-2842.2009.02031.x

    authors: Lethaus B,Lie N,de Beer F,Kessler P,de Baat C,Verdonck HW

    更新日期:2010-02-01 00:00:00

  • Yield strength of zirconia and glass fibre-reinforced posts.

    abstract::The aim of this in vitro study was to evaluate the yield strengths of glass fibre-reinforced composite (FRC) posts and zirconia dioxide ceramic (ZDC) posts. Tapered glass FRC posts (DentinPost) and ZDC posts (Cerapost) of three sizes in diameter (ISO 50, 90, 110) were used for bending tests. Conventional prefabricated...

    journal_title:Journal of oral rehabilitation

    pub_type: 杂志文章

    doi:10.1111/j.1365-2842.2006.01526.x

    authors: Pfeiffer P,Schulz A,Nergiz I,Schmage P

    更新日期:2006-01-01 00:00:00

  • A pilot study of quantitative assessment of mandible advancement using pressure-flow relationship during midazolam sedation.

    abstract::It has been proposed that a titration of the mandibular positioner would be a promising method for predicting the outcome of nasal continuous positive airway pressure (CPAP) therapy. This study was carried out to test the hypothesis that mandible advancement could be evaluated by analysis of inspiratory flow limitatio...

    journal_title:Journal of oral rehabilitation

    pub_type: 杂志文章

    doi:10.1111/j.1365-2842.2006.01627b.x

    authors: Ayuse T,Hoshino Y,Inazawa T,Oi K,Schneider H,Schwartz AR

    更新日期:2006-11-01 00:00:00

  • Magnetic resonance imaging analysis on the relationship between anterior disc displacement and balancing-side occlusal contact.

    abstract::The purpose of this study was to evaluate the relationship between balancing-side occlusal contact patterns and the prevalence of the internal derangement of the temporomandibular joint (TMJ). Forty-one patients were used for the magnetic resonance image (MRI) analysis of TMJ and occlusal examination. Balancing-side o...

    journal_title:Journal of oral rehabilitation

    pub_type: 杂志文章

    doi:10.1046/j.1365-2842.2003.01000.x

    authors: Ohta M,Minagi S,Sato T,Okamoto M,Shimamura M

    更新日期:2003-01-01 00:00:00

  • Effect of LED and halogen light curing on polymerization of resin-based composites.

    abstract::The clinical performance of light polymerized resin-based composites (RBCs) is greatly influenced by the quality of the light curing unit (LCU). A commonly used unit for polymerization of RBC material is the halogen LCUs. However, they have some drawbacks. Development of new blue superbright light emitting diodes (LED...

    journal_title:Journal of oral rehabilitation

    pub_type: 杂志文章

    doi:10.1111/j.1365-2842.2004.01399.x

    authors: Bala O,Olmez A,Kalayci S

    更新日期:2005-02-01 00:00:00

  • The metal post and composite core combination.

    abstract::Restoring broken down non-vital teeth implies in general the provision of a post and core foundation. Many materials and techniques have been introduced for this purpose in recent years. In this article the advantages and disadvantages of the cast and the non-cast post and core are discussed. The problems involved wit...

    journal_title:Journal of oral rehabilitation

    pub_type: 杂志文章

    doi:10.1111/j.1365-2842.1987.tb00687.x

    authors: Käyser AF,Leempoel PJ,Snoek PA

    更新日期:1987-01-01 00:00:00

  • Retention force and fatigue strength of overdenture attachment systems.

    abstract::This study evaluated retention force and fatigue resistance of two overdenture attachment systems. Twenty samples (O-ring and Bar-Clip) from two manufacturers (Conexão Sistemas de Prótese and Lifecore Biomedical) were prepared and divided into four groups: (i) Conexão/O-ring; (ii) Conexão/Bar-Clip; (iii) Lifecore/O-ri...

    journal_title:Journal of oral rehabilitation

    pub_type: 杂志文章

    doi:10.1111/j.1365-2842.2004.01308.x

    authors: Botega DM,Mesquita MF,Henriques GE,Vaz LG

    更新日期:2004-09-01 00:00:00

  • Immediate loading short implants inserted on low bone quantity for the rehabilitation of the edentulous maxilla using an All-on-4 design.

    abstract::More studies evaluating the outcome of short-length dental implants in immediate loading are needed. To evaluate the use of short-length tapered implants in immediate loading for complete edentulous maxillae rehabilitations using an All-on-4 design. This retrospective clinical study included a cohort of 43 patients wi...

    journal_title:Journal of oral rehabilitation

    pub_type: 杂志文章

    doi:10.1111/joor.12291

    authors: Maló P,de Araújo Nobre MA,Lopes AV,Rodrigues R

    更新日期:2015-08-01 00:00:00

  • Expression of c-Fos protein in the trigeminal nuclear complex resulting from quantified force application to the rat molar.

    abstract::This study was conducted to investigate the expression and distribution of c-Fos-like immunoreactive neurones (Fos-neurones), in the rat trigeminal sensory nuclear complex, produced by mechanical forces with various magnitudes and durations applied to the left upper first molar. The magnitudes of forces applied to the...

    journal_title:Journal of oral rehabilitation

    pub_type: 杂志文章

    doi:10.1046/j.1365-2842.2003.01158.x

    authors: Watanabe M,Tanaka E,Suemune S,Satoda T,Maeda N,Uchida T,Tanne K

    更新日期:2003-11-01 00:00:00

  • Implant anchored complete mandibular denture: evaluation of masticatory efficiency, oral function and degree of satisfaction.

    abstract::Masticatory efficiency, oral function and degree of satisfaction with the treatment received were analysed in a group of fully edentulous patients with severe atrophy of the mandibular bone, rehabilitated with complete removable dentures, before and after anchoring the dentures to osseointegrated implants. Masticatory...

    journal_title:Journal of oral rehabilitation

    pub_type: 杂志文章

    doi:10.1046/j.1365-2842.1998.00260.x

    authors: Pera P,Bassi F,Schierano G,Appendino P,Preti G

    更新日期:1998-06-01 00:00:00

  • In vitro cytotoxicity of six dentin bonding agents.

    abstract::The cytotoxicity of six dentin bonding agents (Syntac, Solobond, Bond 1, Scotchbond 1, Heliobond and F-2000) was tested against an established cell line, L929. Under aseptic conditions 3, 5 and 10 microL dentin bonding agents were placed in the centre of Petri dishes. Each dish was covered with a 5-mL suspension of fi...

    journal_title:Journal of oral rehabilitation

    pub_type: 杂志文章

    doi:10.1046/j.1365-2842.2001.00769.x

    authors: Koliniotou-Koubia E,Dionysopoulos P,Koulaouzidou EA,Kortsaris AH,Papadogiannis Y

    更新日期:2001-10-01 00:00:00

  • In vitro retention force changes of prefabricated attachments for overdentures.

    abstract::Changes in the retention force of six prefabricated spherical and cylindrical attachments were examined in vitro under continuous loading. The testing machine permitted insertion-separation cycles to be tested under reproducible conditions while a calibrated measuring device determined the insertion and retention forc...

    journal_title:Journal of oral rehabilitation

    pub_type: 杂志文章

    doi:10.1046/j.1365-2842.2003.01140.x

    authors: Besimo CE,Guarneri A

    更新日期:2003-07-01 00:00:00