Abstract:
PURPOSE:Polyethylene (PE) wear remains a common reason for revision surgery following total hip arthroplasty (THA). An established treatment method is isolated liner exchange in a well-fixed acetabular cup and entails a known high risk of hip dislocation after revision surgery. The purpose of this retrospective study was to determine the rate of hip dislocation after liner exchange. METHODS:Patients were included if (1) the PE liner was removable, (2) the acetabular shell was stable with acceptable orientation, (3) no osteolysis around the acetabular cup was found and (4) no dislocation of the THA occurred before revision surgery. We reviewed medical histories and performed radiological measurements using Einzel-Bild-Röntgen-Analyse (EBRA) software. EBRA measurements and statistical investigations were performed by two independent investigators. RESULTS:A total of 82 patients were included in our study. Mean follow-up was six (range: 3.6-9.9) years. In 13 (15.8%) patients THA dislocations occurred at a mean postoperative period of 20.2 (range: 1-44) weeks after revising the PE liner. This is equivalent to an absolute risk increase of 16% after revision surgery, which results in a number needed to harm of 6. This means that every sixth patient with isolated liner exchange can expect to experience dislocation due to wear. CONCLUSION:In conclusion, isolated exchange of the polyethylene liner because of wear showed a high risk of dislocation and further cup revision. Our results suggest that the threshold for revising well-fixed components in the case of liner wear should be lowered. TRIAL REGISTRATION NUMBER AND DATE OF REGISTRATION:Number: 20140710-1012 and Date: 2016-03-09.
journal_name
Arch Orthop Trauma Surgjournal_title
Archives of orthopaedic and trauma surgeryauthors
Dammerer D,Schneider F,Renkawitz T,Putzer D,Bogensperger M,Biedermann Rdoi
10.1007/s00402-020-03603-3subject
Has Abstractpub_date
2020-11-01 00:00:00pages
1837-1845issue
11eissn
0936-8051issn
1434-3916pii
10.1007/s00402-020-03603-3journal_volume
140pub_type
杂志文章abstract:INTRODUCTION:Recent reports in the adult literature reported the use of standardized radiographic measurement techniques to determine distal radioulnar joint (DRUJ) instability. The aim of this study was to evaluate the efficacy and accuracy of (1) the MRI-based modified radioulnar ratio technique and (2) the pisoscaph...
journal_title:Archives of orthopaedic and trauma surgery
pub_type: 杂志文章
doi:10.1007/s00402-020-03470-y
更新日期:2020-07-01 00:00:00
abstract:BACKGROUND AND PURPOSE:The aim of this study was to investigate the potential of MRI to determine rotational alignment after TKA in comparison to the gold standard, CT. METHODS:Rotational alignment was measured in the transverse plane on CT and MR-images in 14 patients prior to TKA revision. Differences between CT and...
journal_title:Archives of orthopaedic and trauma surgery
pub_type: 杂志文章
doi:10.1007/s00402-015-2289-4
更新日期:2015-11-01 00:00:00
abstract::This prospective study included 43 patients undergoing renal transplantations. Magnetic resonance imaging (MRI) and X-rays of the hip joints were produced 3 and 12 months after transplantation. In 6 hip joints of 4 patients (9.3%), we discovered femoral head necroses just 3 months after transplantation. Three of the h...
journal_title:Archives of orthopaedic and trauma surgery
pub_type: 临床试验,杂志文章
doi:10.1007/BF00426064
更新日期:1997-01-01 00:00:00
abstract::A follow-up after 2 years on average could be done in 43 cases of pelvic ring injuries. Seven were type A, 8 type B and 28 type C lesions. Every type A lesion was treated non-operatively. External fixation and non-operative management were used with type B injuries. As well as non-operative treatment, both internal an...
journal_title:Archives of orthopaedic and trauma surgery
pub_type: 杂志文章
doi:10.1007/BF00434095
更新日期:1997-01-01 00:00:00
abstract:INTRODUCTION:Donor site morbidity constitutes the most prevalent source of complications during anatomic glenoid reconstruction. Therefore, the aim of this study was to evaluate the clinical and radiologic results of arthroscopic anatomic glenoid reconstruction using an allogenic, tricortical iliac crest bone graft for...
journal_title:Archives of orthopaedic and trauma surgery
pub_type: 杂志文章
doi:10.1007/s00402-020-03380-z
更新日期:2020-07-01 00:00:00
abstract:INTRODUCTION:Although it is well known from cadaveric and biomechanical studies that transtibial femoral tunnel (TT) positioning techniques are associated with non-anatomic tunnel positions, controversial data exist as so far no clinical differences could have been found, comparing transtibial with anteromedial techniq...
journal_title:Archives of orthopaedic and trauma surgery
pub_type: 杂志文章
doi:10.1007/s00402-017-2738-3
更新日期:2017-09-01 00:00:00
abstract::Percutaneous lumbar discectomy has gained growing interest during recent years as an alternative to open surgery for protrusions and non-sequestrated subligamentous intervertebral disc herniations. As a less invasive method it competes with chemonucleolysis. At least two modifications are known to date: automated perc...
journal_title:Archives of orthopaedic and trauma surgery
pub_type: 杂志文章
doi:10.1007/BF00453143
更新日期:1990-01-01 00:00:00
abstract:INTRODUCTION:The aim of this study is to evaluate the difference in perioperative complication rate in total hip, bipolar hemiarthroplasties and total knee arthroplasty in patients with Parkinson disease in trauma and elective surgery in our Musculoskeletal Center during a period of 10 years. MATERIAL AND METHOD:Betwe...
journal_title:Archives of orthopaedic and trauma surgery
pub_type: 杂志文章
doi:10.1007/s00402-018-2899-8
更新日期:2018-06-01 00:00:00
abstract::This study investigated the relevance of a mangled extremity severity score (MESS) to the evaluation of intracompartmental pressure in injured patients. We measured intracompartmental pressures with a modification of the Whitesides method and compared these values with MESS in 27 patients after trauma. For 5 of them f...
journal_title:Archives of orthopaedic and trauma surgery
pub_type: 杂志文章
doi:10.1007/BF00444269
更新日期:1995-01-01 00:00:00
abstract:BACKGROUND:The aim of this study was to prospectively investigate the adherence to the American College of Cardiology (ACC) and the American Heart Association guidelines for perioperative assessment of patients with hip fracture in daily clinical practice and how this might affect outcome. METHODS:This prospective coh...
journal_title:Archives of orthopaedic and trauma surgery
pub_type: 杂志文章
doi:10.1007/s00402-019-03270-z
更新日期:2020-01-01 00:00:00
abstract:INTRODUCTION:Cervical spine metastases are relatively rare entities. Only about 10 % of all spinal metastases can be found in this localization. Magnetic resonance imaging and computed tomography are routinely used for early detection. The initial, clinical examination and patients' complaints may not always be very pr...
journal_title:Archives of orthopaedic and trauma surgery
pub_type: 杂志文章
doi:10.1007/s00402-015-2266-y
更新日期:2015-09-01 00:00:00
abstract::In a retrospective study involving 59 patients, a regression equation between nail length and body weight has been computed as follows: nail length = -5.05729 + 0.222 x body height (probability value for intercept P = 0.24327 and slope P = 0.0000). Graphic analysis of the residuals gave a randomly scattered blob of da...
journal_title:Archives of orthopaedic and trauma surgery
pub_type: 杂志文章
doi:10.1007/BF00441830
更新日期:1994-01-01 00:00:00
abstract::We report on a patient who sustained a fracture of the tibial shaft during the removal of the newest type of an intramedullary nail (Expert Tibia Nail, Synthes. In this case report, we discuss the causes of this complication and possible ways to prevent this. ...
journal_title:Archives of orthopaedic and trauma surgery
pub_type: 杂志文章
doi:10.1007/s00402-008-0805-5
更新日期:2009-07-01 00:00:00
abstract:INTRODUCTION:Knee cartilage lesions are very frequent in arthroscopic surgery. This multi-center-study was aimed to evaluate the distribution and possible associated factors of these pathologies in more than 1000 patients. MATERIALS AND METHODS:The German cartilage registry (KnorpelRegister DGOU) started in 2013. In t...
journal_title:Archives of orthopaedic and trauma surgery
pub_type: 杂志文章,多中心研究
doi:10.1007/s00402-016-2432-x
更新日期:2016-06-01 00:00:00
abstract::For the treatment of infected joints, bones and soft tissues, either an instillation drainage therapy or the use of gentamicin-polymethyl-methacrylate (PMMA) chains (Septopal) in addition to surgical revision and systemically given antibiotics is currently in clinical use. We investigated 102 patients treated in our c...
journal_title:Archives of orthopaedic and trauma surgery
pub_type: 杂志文章,评审
doi:10.1007/BF00434543
更新日期:1996-01-01 00:00:00
abstract:STUDY DESIGN:Postoperative outcomes of segmental pedicle screw fixation were evaluated in posterior scoliosis surgery with the use of navigation system. OBJECTIVES:We report the usefulness of a navigation system and a segmental pedicle screw fixation in surgery for scoliosis. SUMMARY OF BACKGROUND DATA:Few reports on...
journal_title:Archives of orthopaedic and trauma surgery
pub_type: 杂志文章
doi:10.1007/s00402-008-0807-3
更新日期:2009-09-01 00:00:00
abstract:INTRODUCTION:In the proximal femoral metaphysis, hematopoietic marrow is predominant during the adult stage of life. The conversion of hematopoietic marrow to fatty marrow in the proximal femoral metaphysis has been suggested as an etiologic factor of ischemia in the pathogenesis of femoral head osteonecrosis. To deter...
journal_title:Archives of orthopaedic and trauma surgery
pub_type: 杂志文章
doi:10.1007/s00402-005-0824-4
更新日期:2005-07-01 00:00:00
abstract:OBJECTIVE:To establish whether a nationally guided programme can lead to more widespread implementation of enhanced recovery after surgery (ERAS), a well-established optimised care pathway for lower limb arthroplasty. DESIGN:In 2010, National Services Scotland's Musculoskeletal Audit was asked to perform a 'snapshot' ...
journal_title:Archives of orthopaedic and trauma surgery
pub_type: 杂志文章
doi:10.1007/s00402-012-1619-z
更新日期:2013-01-01 00:00:00
abstract::After 82 patients underwent osteosynthesis with multiple pinning for a displaced intracapsular femoral neck fracture, 58 fractures were united, and 24 were not. These 82 patients were included in a discriminant analysis. Union and non-union groups were the dependent variables. Eleven presumably predictive factors meas...
journal_title:Archives of orthopaedic and trauma surgery
pub_type: 杂志文章
doi:10.1007/BF00444259
更新日期:1995-01-01 00:00:00
abstract::Septic arthritis of the sternoclavicular joint is rare. Its causes have been reported to include immuno-compromizing diseases, intravenous drug abuse, fractures of the clavicle or catheterization of the subclavian vein. We report a case of septic arthritis of the SCJ in a diabetic patient following periarticular injec...
journal_title:Archives of orthopaedic and trauma surgery
pub_type: 杂志文章,评审
doi:10.1007/s00402-006-0273-8
更新日期:2008-02-01 00:00:00
abstract::A multiplicity of surgical operations have been developed in an attempt to achieve satisfactory function after anterior cruciate ligament (ACL) repair. None of these procedures have been able to reproduce the fiber organization anatomy of attachment site, vascularity, or function of the ACL. Twenty-nine foxhounds rece...
journal_title:Archives of orthopaedic and trauma surgery
pub_type: 杂志文章
doi:10.1007/BF00571523
更新日期:1992-01-01 00:00:00
abstract:INTRODUCTION:Posterior lumbar interbody fusion (PLIF) and internal fixation are commonly performed for the treatment of lower back pain due to lumbar spinal degeneration. We have developed a novel interspinous fixation device, the interspinous fastener (ISF) for potential use in the surgical management of degenerative ...
journal_title:Archives of orthopaedic and trauma surgery
pub_type: 杂志文章
doi:10.1007/s00402-014-1977-9
更新日期:2014-05-01 00:00:00
abstract:INTRODUCTION:Cerclage wiring for reduction of complex femoral shaft fractures can create iatrogenic vascular injury. OBJECTIVE:To describe the anatomical relation of blood vessels to the femur and develop a technical guide for safe passage of cerclage wire. MATERIALS AND METHODS:CT lower-limb angiographs (CTA) of 80 ...
journal_title:Archives of orthopaedic and trauma surgery
pub_type: 杂志文章
doi:10.1007/s00402-017-2804-x
更新日期:2018-01-01 00:00:00
abstract:INTRODUCTION:To evaluate the kinetic amplitude and direction of the long head of the biceps tendon (LHB) within the pulley and the proximal bicipital groove, we performed a 3T-magnetic resonance-throwing motion analysis. MATERIALS AND METHODS:This prospective study was performed on a 3T-MRI scanner. A T2-weighted-3D s...
journal_title:Archives of orthopaedic and trauma surgery
pub_type: 杂志文章
doi:10.1007/s00402-013-1865-8
更新日期:2013-12-01 00:00:00
abstract:INTRODUCTION:The purposes of this study were: (1) to compare tunnel locations using the conventional transtibial technique with reference data, and (2) to identify factors that make it difficult to position the femoral tunnel correctly or contribute to breakage of the bone bridge between the two tibial tunnels. MATERI...
journal_title:Archives of orthopaedic and trauma surgery
pub_type: 杂志文章
doi:10.1007/s00402-013-1780-z
更新日期:2013-08-01 00:00:00
abstract:PURPOSE:In the present study, we aimed to evaluate the impact of two-dimensional multi-planar computed tomography (2D-MP-CT) scans and three-dimensional surface rendering computed tomography reconstruction (3D-SR-CT) on the inter- and intra-observer reliability of four commonly used classification systems for tibial pi...
journal_title:Archives of orthopaedic and trauma surgery
pub_type: 杂志文章
doi:10.1007/s00402-019-03259-8
更新日期:2020-02-01 00:00:00
abstract:INTRODUCTION:Treatment of diaphyseal forearm fractures by open reduction and internal plate fixation is a well-accepted strategy. In a variety of fracture localizations, the use of bridging plate fixation with locking compression plates (LCP) has been shown to improve biomechanical and biological characteristics. Only ...
journal_title:Archives of orthopaedic and trauma surgery
pub_type: 杂志文章
doi:10.1007/s00402-010-1119-y
更新日期:2011-01-01 00:00:00
abstract:BACKGROUND:Patients suffering from ankylosing spondylitis are prone to injuries of the cervical spine even with minor trauma. Although the fractures are markedly unstable, nonsurgical treatment using a halo-thoracic plaster or jacket is a common approach. METHODS:We present three patients with cervicothoracic fracture...
journal_title:Archives of orthopaedic and trauma surgery
pub_type: 杂志文章
doi:10.1007/s00402-003-0488-x
更新日期:2003-04-01 00:00:00
abstract::Due to its hollow construction, which gives it elasticity, the Cenos hollow stem (Artos) reduces stress shielding in the intertrochanteric region and reduces bone remodelling at the distal tip after implantation of a cementless stem in the femoral canal. This should contribute to a longer implant survival time and red...
journal_title:Archives of orthopaedic and trauma surgery
pub_type: 杂志文章
doi:10.1007/BF00441616
更新日期:1994-01-01 00:00:00
abstract::Conclusions on results after resection arthroplasty were made by analyzing patient records with regard to completed questionnaires. Sixty-four patients were followed up for 2.1-15.9 years postoperatively. The indications for explanation were septic or aseptic loosening with extensive bony destruction. The average age ...
journal_title:Archives of orthopaedic and trauma surgery
pub_type: 杂志文章
doi:10.1007/BF00932314
更新日期:1989-01-01 00:00:00