Abstract:
:Percutaneous lumbar discectomy has gained growing interest during recent years as an alternative to open surgery for protrusions and non-sequestrated subligamentous intervertebral disc herniations. As a less invasive method it competes with chemonucleolysis. At least two modifications are known to date: automated percutaneous lumbar discectomy (APLD) with a 2-mm suction probe and non-automated, discoscopy-monitored percutaneous lumbar discectomy with a suction rongeur and a motor-driven shaver (NAPLD). In this study these two methods are compared for the amount of material extracted, dependence upon the degree of degeneration of the disc and intrinsic technical problems, using 20 human cadaver lumbar specimens for experimental testing. Total nucleotomy was not possible with either method. APLD yielded significantly less material and proved to be less effective in severely degenerated intervertebral discs than the NAPLD procedure, as preexisting gaps within the degenerated nucleus pulposus allowed the tissue to shift away from the tip of the 2-mm probe and facilitated displacement of the probe within the anulus fibrosus. By contrast, the rongeur, which first cuts the material to be removed and then carries it away by suction, was much more effective. Further data to support the advantages of non-automated percutaneous nucleotomy are discussed. Pretreatment of the disc with chymopapain did not result in a higher yield of nucleus material when combined with APLD.
journal_name
Arch Orthop Trauma Surgjournal_title
Archives of orthopaedic and trauma surgeryauthors
Pfeiffer M,Schäfer T,Griss P,Mennel HD,Arndt D,Henkel Kdoi
10.1007/BF00453143subject
Has Abstractpub_date
1990-01-01 00:00:00pages
211-6issue
4eissn
0936-8051issn
1434-3916journal_volume
109pub_type
杂志文章abstract:BACKGROUND:Flexible flatfoot is a frequent deformity found in children. The aim of this study is to evaluate the pedographic outcome of the percutaneous arthroereisis with the use of a screw through the sinus tarsi into the talus. MATERIALS AND METHODS:43 calcaneo-stop procedures of 25 patients (18 bilateral, seven un...
journal_title:Archives of orthopaedic and trauma surgery
pub_type: 杂志文章
doi:10.1007/s00402-011-1316-3
更新日期:2011-10-01 00:00:00
abstract:BACKGROUND:Pelvic ring injuries are serious injuries, often associated with substantial morbidity and mortality rates. The long-term consequences of these injuries might affect the patients' personal life. Our aim was to assess the long-term effects of pelvic ring injuries on physical functioning and quality of life (Q...
journal_title:Archives of orthopaedic and trauma surgery
pub_type: 杂志文章
doi:10.1007/s00402-019-03170-2
更新日期:2019-09-01 00:00:00
abstract:OBJECTIVE:To determine the effect of high pressure pulsatile lavage (HPPL) and low pressure pulsatile lavage (LPPL) on cortical and soft tissue blood flow in a canine humerus segmental fracture model. DESIGN:Midshaft humeral osteotomies to create a 2-cm segment of diaphyseal bone were performed on bilateral canine hum...
journal_title:Archives of orthopaedic and trauma surgery
pub_type: 杂志文章
doi:10.1007/s00402-007-0417-5
更新日期:2007-12-01 00:00:00
abstract::The formation of heterotopic ossifications after total hip endoprosthesis implantation is a well-known complication. During the postoperative course laboratory parameters are subject to partial change due to the development of heterotopic ossifications. However, these changes occur relatively late at a time when the a...
journal_title:Archives of orthopaedic and trauma surgery
pub_type: 杂志文章
doi:10.1007/s004020050391
更新日期:1999-01-01 00:00:00
abstract::A total of 20 hip joints of 10 non-fixed corpses were examined within 48 h of death to measure the pressure below the inguinal ligament simulating the surgical conditions during total hip arthroplasty. The purpose of this study was to assess the influence of various leg positions and insertion techniques of retractors...
journal_title:Archives of orthopaedic and trauma surgery
pub_type: 杂志文章
doi:10.1007/s004020050216
更新日期:1998-01-01 00:00:00
abstract::Due to the anatomical situation, intervertebral disc herniation usually results in compression of the anterior epidural space, with lateral or medial irritation of nerve root or cauda equina. Rare locations are an intra- or extraforaminal position or dislocation dorsally. Three patients with dorsal cauda equina compre...
journal_title:Archives of orthopaedic and trauma surgery
pub_type: 杂志文章
doi:10.1007/s004020000213
更新日期:2001-01-01 00:00:00
abstract:INTRODUCTION:We aimed to compare results of treatment of oblique-spiral metacarpal and phalangeal fractures with screw only or mini plate plus screw, respectively. METHODS:A total of 43 patients who were operated with a diagnosis of displaced, irreducible, unstable, rotational oblique-spiral metacarpal and proximal ph...
journal_title:Archives of orthopaedic and trauma surgery
pub_type: 杂志文章
doi:10.1007/s00402-015-2164-3
更新日期:2015-04-01 00:00:00
abstract::A case of painful junctura tendinum of the hand extensors is presented. This rare condition may have developed because of anatomical factors, including the type of connection and location of the junctura, and because of the unique position that the fingers assume during bowling. ...
journal_title:Archives of orthopaedic and trauma surgery
pub_type: 杂志文章
doi:10.1007/s004020050275
更新日期:1998-01-01 00:00:00
abstract:INTRODUCTION:Correct anatomic tunnel positions are essential in anterior cruciate ligament (ACL) reconstruction. To establish recommendations for tunnel positioning based on anatomical findings and to compare tunnel positions with clinical results, different radiological measurement methods as the quadrant method exist...
journal_title:Archives of orthopaedic and trauma surgery
pub_type: 杂志文章
doi:10.1007/s00402-014-1931-x
更新日期:2014-04-01 00:00:00
abstract:INTRODUCTION:The purpose of this study was to identify the tear pattern that could be anatomically repaired by preserving the remaining tendon on footprint and evaluate clinical outcomes of patients who underwent remaining tendon preserving cuff repair. MATERIALS AND METHODS:Of 523 patients with full-thickness rotator...
journal_title:Archives of orthopaedic and trauma surgery
pub_type: 杂志文章
doi:10.1007/s00402-018-2956-3
更新日期:2018-08-01 00:00:00
abstract:OBJECTIVE:To compare the results of two-staged open reduction and internal fixation (ORIF) and limited internal fixation with external fixator (LIFEF) for closed tibial plafond fractures. METHODS:From January 2005 to June 2007, 56 patients with closed type B3 or C Pilon fractures were randomly allocated into groups I ...
journal_title:Archives of orthopaedic and trauma surgery
pub_type: 杂志文章,随机对照试验
doi:10.1007/s00402-010-1075-6
更新日期:2010-10-01 00:00:00
abstract:INTRODUCTION:Various surgical treatment options have been described in athletes with degenerative osteitis pubis who fail to respond to conservative treatment modalities. Although adductor longus tendinopathy often represents an additional pain generator in chronic groin pain associated with osteitis pubis, this has no...
journal_title:Archives of orthopaedic and trauma surgery
pub_type: 杂志文章
doi:10.1007/s00402-013-1777-7
更新日期:2013-07-01 00:00:00
abstract::Acetabular, femoral and tibial torsion of 50 normal adult male subjects were measured by computerized tomography and the relationship between these angles and foot-progression angle was examined. The mean acetabular anteversion was 15.6 degrees on the right and 15.8 degrees on the left, (range 3 degrees-30 degrees). T...
journal_title:Archives of orthopaedic and trauma surgery
pub_type: 杂志文章
doi:10.1007/s004020050459
更新日期:2000-01-01 00:00:00
abstract:INTRODUCTION:Using a cadaver model and multiple continuous compartment pressure measurement, we sought to determine the pressure distribution in different osseofascial spaces of the foot and determine the quickest and most effective technique of pressure release. MATERIALS AND METHODS:The compartment pressures were me...
journal_title:Archives of orthopaedic and trauma surgery
pub_type: 杂志文章
doi:10.1007/s00402-007-0522-5
更新日期:2008-02-01 00:00:00
abstract::Tibial plateau fractures in 17 patients were managed arthroscopically, using interporous hydroxypatite (HA) as a bone graft substitute. Soft-tissue repair and intra-articular lavages were carried out arthroscopically, and depression of the articular surface was done by elevation of the subchondral plate by the bone co...
journal_title:Archives of orthopaedic and trauma surgery
pub_type: 杂志文章
doi:10.1007/BF00453217
更新日期:1996-01-01 00:00:00
abstract:PURPOSE:Flexion of the femoral component in 5° increments downsizes the femoral component, decreases the proximal reach and surface area of the trochlea, delays the engagement of the patella during flexion, and is associated with a higher risk of patellar-femoral instability after kinematically aligned TKA. The present...
journal_title:Archives of orthopaedic and trauma surgery
pub_type: 杂志文章
doi:10.1007/s00402-016-2598-2
更新日期:2017-01-01 00:00:00
abstract:PURPOSE:Cranial migration of shoulder hemiarthroplasties due to rotator cuff insufficiency typically requires conversion into a reverse total shoulder arthroplasty. This study was conducted to analyze differences between the height and offset of six implants designed to enable conversion of a hemiarthroplasty into a re...
journal_title:Archives of orthopaedic and trauma surgery
pub_type: 杂志文章
doi:10.1007/s00402-014-2098-1
更新日期:2014-12-01 00:00:00
abstract:INTRODUCTION:Functional instability is defined as a repeated ankle inversion sprain and a giving way sensation. Previous studies have described the damage of sensori-motor control in ankle sprain as being a possible cause of functional instability. The aim of this study was to evaluate the inversion angle replication e...
journal_title:Archives of orthopaedic and trauma surgery
pub_type: 杂志文章
doi:10.1007/s00402-007-0432-6
更新日期:2008-05-01 00:00:00
abstract:INTRODUCTION:The knee outcome survey-activities of daily living scale (KOS-ADLS) is a patient-reported specific measure of knee function. The KOS-ADLS includes items related to both symptoms and functional limitations experienced during ADL. The purpose of this study was to examine the reliability and validity of a cro...
journal_title:Archives of orthopaedic and trauma surgery
pub_type: 杂志文章
doi:10.1007/s00402-006-0200-z
更新日期:2007-11-01 00:00:00
abstract:PURPOSE:There is a lack of consensus regarding appropriate criteria attesting patient's unrestricted sports activities after ACL reconstruction. The purpose of this study was to perform a survey among experienced arthroscopic surgeons regarding their return to play guidelines in these patients. METHODS:A six-item ques...
journal_title:Archives of orthopaedic and trauma surgery
pub_type: 杂志文章
doi:10.1007/s00402-013-1746-1
更新日期:2013-07-01 00:00:00
abstract:INTRODUCTION:Patients with knee osteoarthritis tend to modify spatial and temporal parameters during walking to reduce the pain. Total knee arthroplasty (TKA) is considered the gold standard treatment for end-stage knee osteoarthritis. However, reduced physical function of the knee is partly, but apparently not fully, ...
journal_title:Archives of orthopaedic and trauma surgery
pub_type: 杂志文章
doi:10.1007/s00402-017-2629-7
更新日期:2017-03-01 00:00:00
abstract:INTRODUCTION:Bisphosphonate therapy has been associated with the development of atypical femoral fractures. The most common sites of bisphosphonate-associated fractures are at the subtrochanteric region followed by the femoral shaft. This retrospective study hypothesizes that increasing anterolateral femoral bow is ass...
journal_title:Archives of orthopaedic and trauma surgery
pub_type: 杂志文章
doi:10.1007/s00402-015-2297-4
更新日期:2015-11-01 00:00:00
abstract:PURPOSE:Anterior knee pain after total knee arthroplasty (TKA) remains a widely discussed postoperative complication. In contrast to sports traumatology, the role of the dissected medial patellofemoral ligament (MPFL) using a medial parapatellar approach in TKA has not been discussed so far. In the present study, it wa...
journal_title:Archives of orthopaedic and trauma surgery
pub_type: 杂志文章
doi:10.1007/s00402-017-2706-y
更新日期:2017-07-01 00:00:00
abstract:INTRODUCTION:Current surgical methods to treat atlantoaxial instability pose potential risks to the surrounding blood vessels and nerves of operative approach. Therefore, more secure and highly effective methods are expected. This study sought to assess the biomechanical efficacy of a novel unilateral double screw-rod ...
journal_title:Archives of orthopaedic and trauma surgery
pub_type: 杂志文章
doi:10.1007/s00402-017-2781-0
更新日期:2017-10-01 00:00:00
abstract:OBJECTIVE:The purpose of this study is to compare the effectiveness and safety of cervical disc arthroplasty with anterior cervical discectomy and fusion for treatment of symptomatic cervical disc disease. Anterior cervical discectomy and fusion (ACDF) is the conventional surgical treatment for symptomatic cervical dis...
journal_title:Archives of orthopaedic and trauma surgery
pub_type: 杂志文章,meta分析
doi:10.1007/s00402-014-2122-5
更新日期:2015-01-01 00:00:00
abstract:INTRODUCTION:Bankart repair laxity may contribute to pathologic joint instability. This biomechanical study compared two screw-in suture anchor-suture combinations under tensile loads. METHODS:Twelve pairs of scapulae were implanted with either a 3 mm diameter, 14 mm long poly-L/D-lactide suture anchor with a suture e...
journal_title:Archives of orthopaedic and trauma surgery
pub_type: 杂志文章
doi:10.1007/s00402-009-0926-5
更新日期:2010-03-01 00:00:00
abstract::We are reporting a case of a flexor profundus tendon rupture of the little finger due to pisotriquetral osteoarthrosis. Resection of the pisiform bone and resurfacing of the carpal tunnel with the joint capsule was performed for the osteoarthrosis and free tendon grafting for the tendon rupture. The tendon grafting an...
journal_title:Archives of orthopaedic and trauma surgery
pub_type: 杂志文章
doi:10.1007/BF00390059
更新日期:1997-01-01 00:00:00
abstract::Six patients with a displaced fracture of the neck or body of the talus were treated using biodegradable screws and rods. During an average follow-up time of 24 (range, 18-31) months, there were no redisplacements nor collapses due to avascular necrosis. All the fractures united. The functional result was mainly depen...
journal_title:Archives of orthopaedic and trauma surgery
pub_type: 杂志文章
doi:10.1007/BF00703443
更新日期:1998-01-01 00:00:00
abstract::A prospective randomized trial in 42 patients undergoing elective total hip or knee arthroplasty under general anaesthesia was carried out to evaluate the efficacy of patient-controlled analgesia (PCA) versus demanded conventional pain therapy (CPT) for controlling postoperative pain. Four patients had to be excluded ...
journal_title:Archives of orthopaedic and trauma surgery
pub_type: 临床试验,杂志文章,随机对照试验
doi:10.1007/s004020050407
更新日期:1999-01-01 00:00:00
abstract:INTRODUCTION:Knee cartilage lesions are very frequent in arthroscopic surgery. This multi-center-study was aimed to evaluate the distribution and possible associated factors of these pathologies in more than 1000 patients. MATERIALS AND METHODS:The German cartilage registry (KnorpelRegister DGOU) started in 2013. In t...
journal_title:Archives of orthopaedic and trauma surgery
pub_type: 杂志文章,多中心研究
doi:10.1007/s00402-016-2432-x
更新日期:2016-06-01 00:00:00