Modular to Monoblock: Difficulties of Detaching the M(2)a-Magnum(TM) Head Are Common in Metal-on-metal Revisions.

Abstract:

BACKGROUND:Modern hip implants typically feature modular heads, which allow for easy exchange and removal from the femoral stem at the time of revision. However, owing to fretting, corrosion, or cold welding, the modular head may be difficult or impossible to separate from the underlying trunnion, especially if the implant has titanium interfaces between the head and the stem. We have repeatedly encountered difficulty removing the titanium sleeve adapter in the M(2)a-Magnum(TM) implant. Although the manufacturer warns about this complication and cases with these difficulties have been reported to the United States FDA, we believed this topic is important to study, because the frequency of difficulties in head removal is unknown and the complications related to this event have not been characterized. QUESTIONS/PURPOSES:We asked: (1) Do revisions of M(2)a-Magnum(TM) implants differ from those of M(2)a-38(TM) implants in terms of ease of removal of the femoral head? (2) In cases where difficulty with M(2)a-Magnum(TM) head removal occurred, was the operative time, bleeding, risk of periprosthetic fracture, or joint infection increased compared with cases where the M(2)a-Magnum(TM) head was removed without difficulties? METHODS:Between 2004 and 2014, we revised 296 THAs with metal-on-metal implants that involved M(2)a-Magnum(TM) (123) or M(2)a-38(TM) heads (88); of those, 84 were planned to include a femoral stem revision and insufficient data were available for three operations, so they were excluded from this analysis, leaving 124 THAs in the current retrospective study (70 THAs with M(2)a-Magnum(TM) and 54 THAs with M(2)a-38(TM) heads).The method of modular head removal, any difficulties removing the femoral head from the trunnion, operation time, and complications were recorded based on chart review. RESULTS:All the observed problems of detaching the head or taper adapter were among M(2)a-Magnum(TM) heads; there were no problems detaching the head in revisions of the M(2)a-38(TM) implant. In 29% (20 of 70) of revisions of the M(2)a-Magnum(TM) implant, the modular head could not be detached by knocking it with a punch and a mallet. Seventeen percent (12 of 70) of hips needed an unplanned stem revision owing to difficulties with head removal. In revisions of the M(2)a-Magnum(TM) implant that experienced head-removal problems, the median operative time was longer (144 minutes; range, 75-274 minutes) and bleeding was greater (725 mL; range, 300-2200 mL) compared with revisions of the M(2)a-Magnum(TM) implant without head removal problems (77 minutes, range, 33-197 minutes, p < 0.001; 475 mL, range, 50-1500 mL, p = 0.004). With the numbers available, we did not see differences in terms of the proportion of patients experiencing major complications (periprosthetic fracture or postoperative infections) between the groups (difficult versus easy; 25% [five of 20] versus 8% [four of 50]; odds ratio, 3.8 [95% CI, 0.9-16.2], p = 0.067). CONCLUSIONS:The titanium-titanium taper junction can be very difficult to separate during revision THAs, and if not anticipated, this problem can result in larger and more complicated revision procedures in patients who have the M(2)a-Magnum(TM) implant. Although the global use of metal-on-metal implants in THAs has decreased dramatically during the last several years, many thousands remain in service and therefore still might require revision. It is crucial to be prepared with special tools, including a femoral head extraction tool and diamond saw. The patient has to be informed of the possibility of a more extensive operation than preoperatively planned. LEVEL OF EVIDENCE:Level III, therapeutic study.

journal_name

Clin Orthop Relat Res

authors

Mäntymäki H,Mäkelä KT,Vahlberg T,Hirviniemi J,Niinimäki T

doi

10.1007/s11999-016-4774-7

subject

Has Abstract

pub_date

2016-09-01 00:00:00

pages

1999-2005

issue

9

eissn

0009-921X

issn

1528-1132

pii

10.1007/s11999-016-4774-7

journal_volume

474

pub_type

杂志文章,多中心研究
  • Surgical techniques of anterior decompression and fusion for spinal cord injuries.

    abstract::Many patients who have static or only slowly improving neurologic deficits and significant compression of the spinal cord and nerve roots can benefit from anterior decompression. The improvement ranges from partial root recovery to very dramatic improvement in upper as well as lower extremities in the patient with qua...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:

    authors: Bohlman HH,Eismont FJ

    更新日期:1981-01-01 00:00:00

  • X-ray diagnosis of healing fractures in rabbits.

    abstract::Do X-rays adequately reflect the strength of callus post fracture? Eleven rabbit tibiae were manually fractured and allowed to heal in plaster. At varying times post fracture, the rabbits were sacrificed and the tibiae were removed. AP and lateral X-rays of each tibia were obtained and shown to 27 orthopedists and rad...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:

    authors: Nicholls PJ,Berg E,Bliven FE Jr,Kling JM

    更新日期:1979-07-01 00:00:00

  • Anatomic alignment of the patellar groove.

    abstract::The variability in alignment of the natural patellar groove was determined about various anatomic axes of the femur, using 3 plane radiographs and electronic digitization. After the patellar groove was identified and marked on 15 anatomic specimen femurs, radiographs were taken in the coronal, sagittal, and transverse...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:10.1097/00003086-199610000-00009

    authors: Feinstein WK,Noble PC,Kamaric E,Tullos HS

    更新日期:1996-10-01 00:00:00

  • What can be learned from minimum 20-year followup studies of knee arthroplasty?

    abstract:BACKGROUND:Long-term evaluation of knee arthroplasty should provide relevant information concerning the durability and performance of the implant and the procedure. Because most arthroplasties are performed in older patients, most long-term followup studies have been performed in elderly cohorts and have had low patien...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:10.1007/s11999-014-3744-1

    authors: Callaghan JJ,Martin CT,Gao Y,Pugely AJ,Liu SS,Goetz DD,Kelley SS,Johnston RC

    更新日期:2015-01-01 00:00:00

  • Prophylaxis for heterotopic bone formation after total hip arthroplasty using low-dose radiation in high-risk patients.

    abstract::Fifteen consecutive total hip arthroplasties (THAs) in 14 patients considered at risk for developing significant heterotopic ossification (HO) were treated postoperatively with 7.5 Gy of external beam radiation in three fractions. Eight hips in eight of the patients (Group I) had developed previous Brooker Class III o...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:

    authors: Maloney WJ,Jasty M,Willett C,Mulroy RD Jr,Harris WH

    更新日期:1992-07-01 00:00:00

  • Accuracy of computer-assisted navigation for femoral head resurfacing decreases in hips with abnormal anatomy.

    abstract::Computer-assisted navigation systems for hip resurfacing arthroplasty are designed to minimize the chance of implant malposition. However, there is little evidence computer navigation is useful in the presence of anatomical deformity. We therefore determined the accuracy of an image-free resurfacing hip arthroplasty n...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:10.1007/s11999-009-0850-6

    authors: Pitto RP,Malak S,Anderson IA

    更新日期:2009-09-01 00:00:00

  • Fractures and dislocations involving the navicular-lunate axis.

    abstract::This is a report of experience with 48 carpal disruptions including anterior dislocations of the lunate, transnavicular perilunate and perilunate dislocations and subluxation of the navicular. The correct radiographic diagnosis is absolutely essential for effective treatment. Many of these injuries may be treated by c...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:

    authors: Morawa LG,Ross PM,Schock CC

    更新日期:1976-07-01 00:00:00

  • Upregulation of apoptotic and matrix-related gene expression during fresh osteochondral allograft storage.

    abstract::We identified changes in proapoptotic and extracellular matrix-related gene expression with prolonged storage of fresh osteochondral allografts using gene array analysis to better understand the process of graft degradation during storage. Six human distal femurs were obtained according to standard organ harvesting pr...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:10.1097/01.blo.0000187058.42820.39

    authors: Robertson CM,Allen RT,Pennock AT,Bugbee WD,Amiel D

    更新日期:2006-01-01 00:00:00

  • Cognitive and Psychomotor Entrustable Professional Activities: Can Simulators Help Assess Competency in Trainees?

    abstract:BACKGROUND:An entrustable professional activity describes a professional task that postgraduate residents must master during their training. The use of simulation to assess performance of entrustable professional activities requires further investigation. QUESTIONS/PURPOSES:(1) Is simulation-based assessment of reside...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:10.1007/s11999-015-4553-x

    authors: Dwyer T,Wadey V,Archibald D,Kraemer W,Shantz JS,Townley J,Ogilvie-Harris D,Petrera M,Ferguson P,Nousiainen M

    更新日期:2016-04-01 00:00:00

  • The Frank Stinchfield Award : Total Hip Arthroplasty for Femoral Neck Fracture Is Not a Typical DRG 470: A Propensity-matched Cohort Study.

    abstract:BACKGROUND:Hip fractures are a major public health concern. For displaced femoral neck fractures, the needs for medical services during hospitalization and extending beyond hospital discharge after total hip arthroplasty (THA) may be different than the needs after THA performed for osteoarthritis (OA), yet these differ...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:10.1007/s11999-016-4868-2

    authors: Schairer WW,Lane JM,Halsey DA,Iorio R,Padgett DE,McLawhorn AS

    更新日期:2017-02-01 00:00:00

  • Effects of implant material and plate design on tendon function and morphology.

    abstract::Titanium implants are an alternative to stainless steel implants for internal fixation after fracture. The advantages of titanium include decreased implant stiffness, increased bio-compatibility, and diminished stress shielding. However, titanium has been implicated in tendon irritation and adhesions when used in the ...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:10.1097/01.blo.0000205894.98361.29

    authors: Cohen MS,Turner TM,Urban RM

    更新日期:2006-04-01 00:00:00

  • Effect of methotrexate in the biology of free vascularized bone grafts. A comparative experimental study in the dog.

    abstract::To evaluate the effects of methotrexate (MTX) on the biology of a vascularized bone graft (VBG), a study of adult dogs was performed. Different protocols of treatment using MTX, with or without the administration of citrovorum rescue factor (CRF), were studied. A controlled experiment involving 18 dogs was performed t...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:

    authors: Canosa R,González del Pino J

    更新日期:1994-04-01 00:00:00

  • The Otto Aufranc Award. Highly cross-linked polyethylene in total hip arthroplasty: randomized evaluation of penetration rate in cemented and uncemented sockets using radiostereometric analysis.

    abstract::The annual wear rate in polyethylene articulations should be 0.1 mm or less to avoid future osteolysis. Highly cross-linked polyethylene shows an 80 to 90% wear reduction in hip simulator testing, but the clinical documentation of this new polyethylene is still inadequate. We evaluated the highly cross-linked polyethy...

    journal_title:Clinical orthopaedics and related research

    pub_type: 临床试验,杂志文章,随机对照试验,评审

    doi:

    authors: Digas G,Kärrholm J,Thanner J,Malchau H,Herberts P

    更新日期:2004-12-01 00:00:00

  • 2006 Otto Aufranc Award Paper: significance of in vivo degradation for polyethylene in total hip arthroplasty.

    abstract::Our research group developed an implant retrieval program to study in vivo degradation of polyethylene. We now have evidence to support our hypothesis that degradation of radiation-sterilized polyethylene occurs in the body for not only historical gamma air sterilized liners, but also for conventional gamma inert ster...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:10.1097/01.blo.0000246547.18187.0b

    authors: Kurtz SM,Hozack WJ,Purtill JJ,Marcolongo M,Kraay MJ,Goldberg VM,Sharkey PF,Parvizi J,Rimnac CM,Edidin AA

    更新日期:2006-12-01 00:00:00

  • The compartment syndrome. An experimental and clinical study of muscular energy metabolism using phosphorus nuclear magnetic resonance spectroscopy.

    abstract::In an experimental ischemic compartment syndrome in dogs, phosphorus (31P) nuclear magnetic resonance (NMR) spectroscopy was used to determine the tissue pressure threshold at which resting skeletal muscle begins to use anaerobic energy sources due to insufficient cellular oxygen delivery. The interactive effects of s...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章,评审

    doi:

    authors: Heppenstall RB,Sapega AA,Scott R,Shenton D,Park YS,Maris J,Chance B

    更新日期:1988-01-01 00:00:00

  • Surgical treatment of the tibia in osteogenesis imperfecta.

    abstract::Segmentation and intramedullary rod fixation of the tibia have been found to be safe and effective procedures in osteogenesis imperfecta. An extensible rod is more difficult to insert than a solid rod due to the problem of obtaining an adequate fit distally, so the practical advantage of one type over the other is not...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:

    authors: Niemann KM

    更新日期:1981-09-01 00:00:00

  • Coding of diagnoses, comorbidities, and complications of total hip arthroplasty.

    abstract::International Classification of Diseases coding of patient charts is used by hospitals to allow for billing of patients. Coding information also is used for assessing physician effectiveness. The purpose of the current study was to examine hospital coding for patients having total hip arthroplasty. One hundred consecu...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:10.1097/00003086-200209000-00014

    authors: Mears SC,Bawa M,Pietryak P,Jones LC,Rajadhyaksha AD,Hungerford DS,Mont MA

    更新日期:2002-09-01 00:00:00

  • Cortisone induced bone changes and its response to lipid clearing agents.

    abstract::Thirty-two rabbits were used experimentally to study the effect of cortisone in bone, lungs, kidneys, and liver. Cortisone does induce abnormal increases in the serum cholesterol, fatty metamorphosis of the liver and the fatty emboli of the subchondral vessels of the femoral heads. Clofibrate therapy appeared to modif...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:

    authors: Wang GJ,Moga DB,Richemer WG,Sweet DE,Reger SI,Thompson RC

    更新日期:1978-01-01 00:00:00

  • Radiotherapy in the management of bone pain.

    abstract::Radiotherapy may be indicated for the management of bone metastases because of associated pain, fracture, or neurologic complications. For metastatic bone pain, simple low-dose radiation treatment is usually effective for local problems. When there are multiple sites of bone pain, external beam irradiation using wide-...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章,评审

    doi:

    authors: Hoskin PJ

    更新日期:1995-03-01 00:00:00

  • Fractures of the distal end of the radius. An historical account.

    abstract::From the time of Hippocrates to the beginning of the nineteenth century, fractures of the distal end of the radius were mistaken for dislocations of the wrist. Clinical observations, anatomic dissections, and experiments on cadavers dispelled this error. It was not, however, until after the discovery of roentgenograms...

    journal_title:Clinical orthopaedics and related research

    pub_type: 传,历史文章,杂志文章

    doi:

    authors: Peltier LF

    更新日期:1984-07-01 00:00:00

  • Implant Design Variations in Reverse Total Shoulder Arthroplasty Influence the Required Deltoid Force and Resultant Joint Load.

    abstract:BACKGROUND:Reverse total shoulder arthroplasty (RTSA) is widely used; however, the effects of RTSA geometric parameters on joint and muscle loading, which strongly influence implant survivorship and long-term function, are not well understood. By investigating these parameters, it should be possible to objectively opti...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:10.1007/s11999-015-4526-0

    authors: Giles JW,Langohr GD,Johnson JA,Athwal GS

    更新日期:2015-11-01 00:00:00

  • Constitutional varus does not affect joint line orientation in the coronal plane.

    abstract:BACKGROUND:In a previous study, we described the distribution of coronal alignment in a normal asymptomatic population and recognized the occurrence of constitutional varus in one of four individuals. It is important to further investigate the influence of this condition on the joint line orientation and how the latter...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:10.1007/s11999-013-2898-6

    authors: Victor JM,Bassens D,Bellemans J,Gürsu S,Dhollander AA,Verdonk PC

    更新日期:2014-01-01 00:00:00

  • Glomus tumor of the musculotendinous junction of the rotator cuff. A case report.

    abstract::A rare case of glomus tumor of the rotator cuff is presented. A 35-year-old man had a 20-year history of left shoulder pain. Through physical examination, muscular atrophy in the supraspinatus and infraspinatus muscles and restriction of shoulder motion was seen. Magnetic resonance imaging showed an abnormal oval shad...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:10.1097/00003086-199605000-00031

    authors: Yoshikawa G,Murakami M,Ishizawa M,Matsumoto K,Hukuda S

    更新日期:1996-05-01 00:00:00

  • Bone-block iliotibial band reconstruction for anterior cruciate insufficiency. Follow-up note and minimum five-year follow-up period.

    abstract::Sixty-two of 71 patients (87%) who received a bone-block iliotibial band transfer were followed with a minimum follow-up period of five years (range, 5-10 years). Sixteen of the originally studied knees were examined with an average follow-up period of 104 months (range, 90-120 months). A second group of 46 knees was ...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:

    authors: Windsor RE,Insall JN

    更新日期:1990-01-01 00:00:00

  • Nucleus pulposus allograft retards intervertebral disc degeneration.

    abstract::Autogenous implantation of nucleus pulposus or nucleus pulposus cells that were activated by coculture retards intervertebral disc degeneration, but harvesting such grafts causes disc degeneration at the donor site. This study examined whether nucleus pulposus allografts similarly retard disc degeneration and whether ...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:10.1097/00003086-200108000-00015

    authors: Nomura T,Mochida J,Okuma M,Nishimura K,Sakabe K

    更新日期:2001-08-01 00:00:00

  • Preoperative hip to ankle radiographs in total knee arthroplasty.

    abstract::Whether a preoperative long leg radiograph taken with the patient standing helps the surgeon reproduce a normal mechanical axis after total knee arthroplasty is unknown. The purpose of the current study was to evaluate whether a preoperative long leg radiograph helps to restore normal limb alignment after total knee a...

    journal_title:Clinical orthopaedics and related research

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1097/00003086-200211000-00032

    authors: McGrory JE,Trousdale RT,Pagnano MW,Nigbur M

    更新日期:2002-11-01 00:00:00

  • Fixation, polyethylene wear, and pelvic osteolysis in primary total hip replacement.

    abstract::A multicenter retrospective review was performed analyzing 1081 primary total hip replacements in 944 patients using the Harris Galante-I cementless acetabular component with screw fixation. All patients were followed up for a minimum of 5 years with a mean followup of 81 months. Linear polyethylene wear averaged 0.11...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章,多中心研究

    doi:10.1097/00003086-199912000-00016

    authors: Maloney WJ,Galante JO,Anderson M,Goldberg V,Harris WH,Jacobs J,Kraay M,Lachiewicz P,Rubash HE,Schutzer S,Woolson ST

    更新日期:1999-12-01 00:00:00

  • Enhancing osteochondral allograft viability: effects of storage media composition.

    abstract::Osteochondral allograft transplantation is a well-accepted treatment for articular cartilage damage. However, chondrocyte viability declines during graft storage, which may compromise graft performance. We first tested the hypothesis that the composition of commonly used storage media affects the viability of articula...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:10.1007/s11999-008-0302-8

    authors: Teng MS,Yuen AS,Kim HT

    更新日期:2008-08-01 00:00:00

  • Disease- and recurrence-free survival after surgical resection of solitary bone metastases of the pelvis.

    abstract::For patients with advanced cancer who present with or develop a bone lesion as the only focus of cancer beyond the primary site, en bloc resection of the metastasis may optimize local tumor control, provide durable pain relief, and possibly prolong patient survival. For patients with pelvic metastasis, however, this s...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:10.1097/BLO.0b013e3180619533

    authors: Yasko AW,Rutledge J,Lewis VO,Lin PP

    更新日期:2007-06-01 00:00:00

  • Reconstructive osteotomy for malunion of the distal radius.

    abstract::Common misconceptions about distal radius fractures result in undertreatment of many fractures, particularly in an active population. Loss of reduction of the fracture may cause a symptomatic malunion. Fourteen patients with an average age of 39 years (range, 21-65 years) underwent reconstructive procedures for radial...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:10.1097/00003086-199606000-00021

    authors: Ladd AL,Huene DS

    更新日期:1996-06-01 00:00:00