Switched surface coil system for bilateral MR imaging.

Abstract:

:A method is presented for acquiring magnetic resonance (MR) images in parallel from both members of a pair of organs, such as the temporomandibular joint (TMJ), with use of two surface coil receivers. Interleaved sagittal sections are broken into two groups, one on each side of the head, and the MR receiver is toggled between the two coils. The surface coil that is not receiving at a given time is decoupled from the other surface coil by the active gating of a diode blocking network located across the coil input. This method produces effective decoupling independent of coil loading and positioning and makes it possible to use the same surface coils already employed for single-coil MR reception. Clinical application in 95 patients (190 joints) with symptoms of internal derangement of the TMJ demonstrated a 24% average decrease in total patient examination time, even after the addition of coronal imaging to the procedure. In no case was there a sacrifice in diagnostic quality.

journal_name

Radiology

journal_title

Radiology

authors

Hardy CJ,Katzberg RW,Frey RL,Szumowski J,Totterman S,Mueller OM

doi

10.1148/radiology.167.3.3363150

subject

Has Abstract

pub_date

1988-06-01 00:00:00

pages

835-8

issue

3

eissn

0033-8419

issn

1527-1315

journal_volume

167

pub_type

杂志文章
  • US-guided core biopsy of the breast with a coaxial system.

    abstract::From July 1993 through June 1994, the authors performed 42 ultrasound (US)-guided core biopsies with use of a coaxial technique in which a 14- or 15-gauge core biopsy needle was passed through a 12-gauge introducer needle. This technique proved to be effective in all 42 biopsies. Use of the coaxial technique decreased...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.194.2.7824740

    authors: Kaplan SS,Racenstein MJ,Wong WS,Hansen GC,McCombs MM,Bassett LW

    更新日期:1995-02-01 00:00:00

  • Nonpalpable breast lesions: accuracy of prebiopsy mammographic diagnosis.

    abstract::Mammograms of 220 patients who underwent spot localization for removal of nonpalpable breast lesions were reviewed for accuracy of interpretation. Results of subsequent biopsy indicated malignancy in 77 cases. The interpretations of mammograms obtained before biopsy were incorrect in 71 cases (27 false-negative and 44...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.165.2.3659350

    authors: Hermann G,Janus C,Schwartz IS,Krivisky B,Bier S,Rabinowitz JG

    更新日期:1987-11-01 00:00:00

  • Obstructive sleep apnea: diagnosis with ultrafast CT.

    abstract::Patients with sleep-disordered breathing often have physiologic and anatomic abnormalities of the upper airway that are demonstrable while awake. An ultrafast computed tomographic (CT) scanner was used to measure the oropharyngeal and nasopharyngeal cross-sectional areas of 11 patients with obstructive sleep apnea. Tw...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.171.3.2717750

    authors: Galvin JR,Rooholamini SA,Stanford W

    更新日期:1989-06-01 00:00:00

  • Pulmonary embolism after hip or knee replacement: postoperative changes on pulmonary scintigrams in asymptomatic patients.

    abstract::Serial pulmonary imaging has proved to be effective in the evaluation of patients undergoing total joint arthroplasty. A clinical dilemma arises in asymptomatic patients whose postoperative pulmonary images differ from the preoperative images. The authors prospectively evaluated 403 patients with serial imaging to det...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.172.2.2748830

    authors: Foley M,Maslack MM,Rothman RH,Casey MP,Lugano EM,Parry CE,Balderston RA,Booth RE Jr

    更新日期:1989-08-01 00:00:00

  • Regional Mapping of Aortic Wall Stress by Using Deformable, Motion-coherent Modeling based on Electrocardiography-gated Multidetector CT Angiography: Feasibility Study.

    abstract::Purpose To investigate the feasibility of deformable, motion-coherent modeling based on electrocardiography-gated multidetector computed tomographic (CT) angiography of the thoracic aorta and to evaluate whether quantifiable information on aortic wall stress as a function of patient-specific cardiovascular parameters ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2015151078

    authors: Mileto A,Heye TJ,Makar RA,Hurwitz LM,Marin D,Boll DT

    更新日期:2016-07-01 00:00:00

  • Staging non-small cell lung cancer with whole-body PET.

    abstract:PURPOSE:To compare the accuracies of whole-body 2-[fluorine 18]fluoro-2-deoxy-D-glucose (FDG) positron emission tomography (PET) and conventional imaging (thoracic computed tomography [CT], bone scintigraphy, and brain CT or magnetic resonance [MR] imaging) in staging bronchogenic carcinoma. MATERIALS AND METHODS:With...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.212.3.r99se21803

    authors: Marom EM,McAdams HP,Erasmus JJ,Goodman PC,Culhane DK,Coleman RE,Herndon JE,Patz EF Jr

    更新日期:1999-09-01 00:00:00

  • Radiographic absorptiometry for bone mineral measurement of the phalanges: precision and accuracy study.

    abstract:PURPOSE:To evaluate the accuracy and precision of a radiographic absorptiometry (RA) method for assessment of bone mineral of the middle phalanges. MATERIALS AND METHODS:Nineteen cadaveric hands were radiographed with an aluminum wedge, once at 50 kVp and 400 mA and once at 60 kVp and 300 mA. Bone mineral content (BMC...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.192.3.8058960

    authors: Yang SO,Hagiwara S,Engelke K,Dhillon MS,Guglielmi G,Bendavid EJ,Soejima O,Nelson DL,Genant HK

    更新日期:1994-09-01 00:00:00

  • Resonance by rod-shaped reflectors in ultrasound test objects.

    abstract::Rod-shaped reflectors such as those used in the AIUM test object resonate at medical ultrasound frequencies, producing artifacts posterior to the reflector. Rods of various diameters and materials were examined to determine their resonant properties, and the effect of the Plexiglas scanning surface of the enclosure on...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.139.1.7208920

    authors: Hefner LV,Goldstein A

    更新日期:1981-04-01 00:00:00

  • F-18 fluorodeoxyglucose PET in vivo evaluation of pancreatic glucose metabolism for detection of pancreatic cancer.

    abstract:PURPOSE:To evaluate positron emission tomography (PET) with fluorine-18-labeled fluorodeoxyglucose (FDG) for detection of pancreatic cancer compared with computed tomography (CT) and ultrasonography (US). MATERIALS AND METHODS:Forty patients with suspected pancreatic cancer underwent static PET after intravenous injec...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.192.1.8208970

    authors: Bares R,Klever P,Hauptmann S,Hellwig D,Fass J,Cremerius U,Schumpelick V,Mittermayer C,Büll U

    更新日期:1994-07-01 00:00:00

  • Fibrin sealant in interventional radiology: a preliminary evaluation.

    abstract::Tisseel, a fibrin sealant not approved for use in the United States, was tested in abdominal fistulas and sinuses (13 patients) and interventional biliary procedures (11 patients). The two components of Tisseel were introduced via a double-lumen catheter and formed a fibrin gel at the point of contact. Tracts were sea...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.196.2.7617880

    authors: Brady AP,Malone DE,Deignan RW,O'Donovan N,McGrath FP

    更新日期:1995-08-01 00:00:00

  • Clear cell chondrosarcoma.

    abstract::The clinical, radiologic, and histopathologic features of three cases of clear cell chondrosarcoma are described. On radiographs, this rather benign-appearing tumor resembles a chondroblastoma when it occurs at the end of a long bone, and may occasionally show a calcified matrix. However, it has distinctive tumor cell...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.154.1.3964950

    authors: Kumar R,David R,Cierney G 3rd

    更新日期:1985-01-01 00:00:00

  • Dynamic MR defecography with a superconducting, open-configuration MR system.

    abstract:PURPOSE:To evaluate dynamic magnetic resonance (MR) defecography performed with a superconducting, open-configuration system in diagnosis of defecation disorders. MATERIALS AND METHODS:Five healthy volunteers and 15 patients with defecation disorders were studied with MR defecography performed with a superconducting, ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.206.3.9494480

    authors: Schoenenberger AW,Debatin JF,Guldenschuh I,Hany TF,Steiner P,Krestin GP

    更新日期:1998-03-01 00:00:00

  • The double sac sign of early intrauterine pregnancy: use in exclusion of ectopic pregnancy.

    abstract::Pelvic sonograms from 61 consecutive patients with suspected ectopic pregnancy and an additional 17 proved ectopic pregnancy cases were reviewed retrospectively. Special attention was given to the appearance of the uterus and intrauterine fluid collections in the absence of a fetal pole. Criteria for the exclusion of ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.143.1.7063730

    authors: Bradley WG,Fiske CE,Filly RA

    更新日期:1982-04-01 00:00:00

  • Endovascular MR-guided Renal Embolization by Using a Magnetically Assisted Remote-controlled Catheter System.

    abstract::Purpose To assess the feasibility of a magnetically assisted remote-controlled (MARC) catheter system under magnetic resonance (MR) imaging guidance for performing a simple endovascular procedure (ie, renal artery embolization) in vivo and to compare with x-ray guidance to determine the value of MR imaging guidance an...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2016152036

    authors: Lillaney PV,Yang JK,Losey AD,Martin AJ,Cooke DL,Thorne BR,Barry DC,Chu A,Stillson C,Do L,Arenson RL,Saeed M,Wilson MW,Hetts SW

    更新日期:2016-10-01 00:00:00

  • Long-term Graft and Patient Survival after Percutaneous Angioplasty or Arterial Stent Placement for Transplant Renal Artery Stenosis: A 21-year Matched Cohort Study.

    abstract::Purpose To compare long-term graft and patient survival after percutaneous angioplasty (PTA) or stent placement for transplant renal artery stenosis (TRAS) with a control cohort without TRAS. Materials and Methods This is a retrospective matched cohort study of 41 patients (median age, 49 years; range, 18-72 years), i...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2018181320

    authors: Patel U,Kumar S,Johnson OW,Jeon JH,Das R

    更新日期:2019-02-01 00:00:00

  • Anterior inferior cerebellar artery originating from the cavernous portion of the internal carotid artery.

    abstract::An anomalous branch of the cavernous carotid artery, not reported previously, is described. Its appearance and distribution were unlike those of any known cavernous branch, originating at the level where the trigeminal artery is usually found but having no communication with the basilar artery. Its distribution approx...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/116.1.93

    authors: Scotti G

    更新日期:1975-07-01 00:00:00

  • Radiation-induced decrease in nitric oxide synthase--containing nerves in the rat penis.

    abstract:PURPOSE:Evaluate effect of prostatic irradiation on erectile function. MATERIALS AND METHODS:Forty-seven male adult rats were divided into three groups according to a single radiation dose to the prostate: control (no irradiation) (n = 15), 1,000 cGy (n = 15), and 2,000 cGy (n = 17). Five months after irradiation, rat...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.195.1.7534430

    authors: Carrier S,Hricak H,Lee SS,Baba K,Morgan DM,Nunes L,Ross GY,Phillips TL,Lue TF

    更新日期:1995-04-01 00:00:00

  • Does radiologist recommendation for follow-up with the same imaging modality contribute substantially to high-cost imaging volume?

    abstract:PURPOSE:To retrospectively measure repeat rates for high-cost imaging studies, determining their causes and trends, and the impact of radiologist recommendations for a repeat examination on imaging volume. MATERIALS AND METHODS:This HIPAA-compliant study had institutional review board approval, with waiver of informed...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2423051754

    authors: Lee SI,Saokar A,Dreyer KJ,Weilburg JB,Thrall JH,Hahn PF

    更新日期:2007-03-01 00:00:00

  • The juxtaphrenic peak in upper lobe collapse.

    abstract::Steeple-shaped shadows adjacent to the diaphragm are common in upper lobe collapse due to a variety of causes. They call attention to upper lobe collapse and should not be considered indicative of intrinsic lower lobe abnormality. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.134.3.7355230

    authors: Kattan KR,Eyler WR,Felson B

    更新日期:1980-03-01 00:00:00

  • Performance of Screening Breast MRI across Women with Different Elevated Breast Cancer Risk Indications.

    abstract::Background Screening breast MRI is recommended for women with BRCA mutation or a history of chest radiation, but guidelines are equivocal for MRI screening of women with a personal history of breast cancer or high-risk lesion. Purpose To evaluate screening breast MRI performance across women with different elevated br...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2019181136

    authors: Sippo DA,Burk KS,Mercaldo SF,Rutledge GM,Edmonds C,Guan Z,Hughes KS,Lehman CD

    更新日期:2019-07-01 00:00:00

  • Effects of exposure of CHO-K1 cells to a 10-T static magnetic field.

    abstract:PURPOSE:To evaluate whether exposure to strong static magnetic fields (SMFs), of up to 10 T, affects the growth and cycle distribution of and the micronucleus formation in monolayered Chinese hamster ovary CHO-K1 cells. MATERIALS AND METHODS:The authors developed a system to expose cultured cells to strong SMFs immedi...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2243011300

    authors: Nakahara T,Yaguchi H,Yoshida M,Miyakoshi J

    更新日期:2002-09-01 00:00:00

  • Male breast carcinoma and gynecomastia: comparison of mammography with sonography.

    abstract::Both ultrasonography and x-ray mammography were performed on a male patient who had breast carcinoma. While the x-ray mammographic features were highly suggestive of malignancy, the sonographic findings were subtle. Because of the technical difficulties associated with x-ray mammography of the male breast, ultrasound ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.149.2.6622700

    authors: Jackson VP,Gilmor RL

    更新日期:1983-11-01 00:00:00

  • Aortic and hepatic peak enhancement at CT: effect of contrast medium injection rate--pharmacokinetic analysis and experimental porcine model.

    abstract:PURPOSE:To investigate the effect of injection rate of contrast medium on aortic and hepatic peak enhancement at computed tomography. MATERIALS AND METHODS:Early pharmacokinetics of contrast enhancement was analyzed theoretically and simulated with a compartment model. Contrast enhancement curves were generated from t...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.206.2.9457200

    authors: Bae KT,Heiken JP,Brink JA

    更新日期:1998-02-01 00:00:00

  • Spermatic vein embolization with hot contrast material: fertility results.

    abstract::Spermatic venography with hot contrast material embolization was undertaken in 81 patients with varicoceles and infertility. Long-term follow-up information was available in 91% of the patients, and there was an overall conception rate of 40.5%. Embolization with hot contrast material was easily performed without spec...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.168.1.3380950

    authors: Smith TP,Hunter DW,Cragg AH,Darcy MD,Castaneda-Zuniga WR,Sinclair TR,Ercole C,Hulbert JC,Kaye KW,Amplatz K

    更新日期:1988-07-01 00:00:00

  • Tissue relaxation time: in vivo field dependence.

    abstract::Relaxation times (T1 and T2) were measured in vivo in mongrel dogs at fields of 0.3, 0.5, 1.0, 1.35, and 1.5 tesla (T). T1 was measured using nine values of inversion time ranging from 10 to 1,280 msec. T2 was measured with a four-point multiple spin-echo sequence. Relaxation times were calculated for muscle, kidney c...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.156.3.2991980

    authors: Johnson GA,Herfkens RJ,Brown MA

    更新日期:1985-09-01 00:00:00

  • Real-time digitally subtracted fluoroscopy for cervical myelography.

    abstract::Improved visualization of the initial bolus of contrast material injected via a lateral Cl-2 puncture for cervical myelography can be obtained by using real-time digital subtraction fluoroscopy. As little as 0.1 ml of metrizamide (250 mg%) can be demonstrated easily. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.151.1.6366910

    authors: Sherry RG,Anderson RE

    更新日期:1984-04-01 00:00:00

  • A molded acrylic applicator guiding the peroral X-ray beam.

    abstract::An intraoral acrylic mold technique to guide and maintain beam direction during oral roentgen therapy is described. It is used in combination with the treatment cone and a lead tube and protective diaphragm for collimation of the beam. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/118.2.471

    authors: Pantoja E,Rodriguez-Ibanez I

    更新日期:1976-02-01 00:00:00

  • Normal prostate gland: examination with color Doppler US.

    abstract:PURPOSE:To evaluate the vascular anatomy of the prostate gland with transrectal color Doppler ultrasound (US). MATERIALS AND METHODS:Thirty-five normal prostate glands were studied. Imaging findings were interpreted on the basis of findings from previous anatomic studies. RESULTS:Distribution of flow signals within t...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.196.2.7617860

    authors: Neumaier CE,Martinoli C,Derchi LE,Silvestri E,Rosenberg I

    更新日期:1995-08-01 00:00:00

  • Time-Intensity Curves Obtained after Microbubble Injection Can Be Used to Differentiate Responders from Nonresponders among Patients with Clinically Active Crohn Disease after 6 Weeks of Pharmacologic Treatment.

    abstract::Purpose To assess whether contrast material-enhanced ultrasonography (US) can be used to differentiate responders from nonresponders among patients with clinically active Crohn disease after 6 weeks of pharmacologic treatment. Materials and Methods This prospective study was approved by our ethics committee, and writt...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2016152461

    authors: Quaia E,Sozzi M,Angileri R,Gennari AG,Cova MA

    更新日期:2016-11-01 00:00:00

  • Mechanical Thrombectomy in Subtypes of Basilar Artery Occlusion: Relationship to Recanalization Rate and Clinical Outcome.

    abstract::Background Acute stroke because of basilar artery occlusion (BAO) represents 1% of all ischemic strokes. However, recanalization rates and treatment outcome for the different pathologic subtypes of BAO stroke are not fully understood. Purpose To compare the recanalization rate and clinical outcomes of mechanical throm...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2019181924

    authors: Baik SH,Park HJ,Kim JH,Jang CK,Kim BM,Kim DJ

    更新日期:2019-06-01 00:00:00