Comparison of iris-claw and posterior chamber collagen copolymer phakic intraocular lenses in keratoconus.

Abstract:

PURPOSE:To evaluate the visual and refractive outcomes, predictability, and stability of phakic intraocular lens (pIOL) implantation in keratoconic eyes and compare the results of 2 pIOL models. SETTING:Vissum Instituto Oftalmologico, Alicante, Spain. DESIGN:Retrospective case series. METHODS:An iris-claw (Artiflex) or collagen copolymer posterior chamber pIOL (PC pIOL) (Implantable Collamer Lens) was implanted in eyes with stable keratoconus. The main outcome measures were postoperative changes from the preoperative manifest refraction, uncorrected (UDVA) and corrected (CDVA) distance visual acuities, corneal topography, and endothelial cell count. Alpins vectorial analysis was performed. RESULTS:Twenty eyes received an iris-claw pIOL and 28 eyes, a PC pIOL. The mean spherical equivalent was -9.31 diopters (D) ± 4.20 (SD) (range -20.75 to -2.75) preoperatively and -0.46 ± 0.88 D (range -3.25 to 1.00 D) postoperatively (P<.001). No patient lost lines of CDVA. The mean decimal UDVA was 0.08 ± 0.09 preoperatively and 0.71 ± 0.26 postoperatively and the mean decimal CDVA, 0.77 ± 0.24 and 0.87 ± 0.98, respectively (P<.001). The mean efficacy index was 0.90 ± 0.26 and the mean safety index, 1.19 ± 0.29. The mean efficacy index was not statistically different between the PC pIOL (0.88 ± 0.28) and the iris-claw pIOL (0.96 ± 0.22) (P=.058). Refraction was stable during the follow-up. CONCLUSIONS:Phakic IOL implantation is a suitable refractive surgical option for stable keratoconus. It may be especially indicated for the management of high ametropia and showed good efficacy and safety. Refractive and keratometric stability was confirmed.

authors

Alió JL,Peña-García P,Abdulla G F,Zein G,Abu-Mustafa SK

doi

10.1016/j.jcrs.2013.07.052

subject

Has Abstract

pub_date

2014-03-01 00:00:00

pages

383-94

issue

3

eissn

0886-3350

issn

1873-4502

pii

S0886-3350(13)01521-6

journal_volume

40

pub_type

杂志文章
  • Reversibility and exchangeability of intrastromal corneal ring segments.

    abstract:PURPOSE:To evaluate the effect of removal and/or exchange of intrastromal corneal ring segments (ICRS, Intacs); specifically the risk factors, degree of reversibility, and visual outcomes. SETTING:Gimbel Eye Centres, Calgary, Edmonton, and Vancouver, Canada. METHODS:Prospective cohort data were collected on 71 eyes t...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(01)01172-5

    authors: Chan SM,Khan HN

    更新日期:2002-04-01 00:00:00

  • Phacoemulsification with corneal astigmatism correction with the use of a toric intraocular lens in a case of megalocornea.

    abstract::We report the case of a 49-year-old patient with megalocornea and coexisting corneal astigmatism. The corneal diameter in the right eye was 15.0 mm and in the left eye, 14.9 mm. In both eyes, a nuclear sclerotic cataract developed, with the tendency toward cortical mass swelling in the right eye. The aim of surgical t...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2011.04.023

    authors: Rękas M,Pawlik R,Kluś A,Różycki R,Szaflik JP,Ołdak M

    更新日期:2011-08-01 00:00:00

  • Custom-contoured ablation pattern method for the treatment of decentered laser ablations.

    abstract:PURPOSE:To evaluate the custom-contoured ablation pattern (C-CAP) method as a tool for providing customized laser ablations for decentered ablations based on corneal topography data. SETTING:Department of Ophthalmology, Stanford University, Stanford, California, USA. METHODS:In a prospective noncomparative interventi...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2003.12.052

    authors: Lin DY,Manche EE

    更新日期:2004-08-01 00:00:00

  • Refractive error with optimum intraocular lens power calculation after glaucoma filtering surgery.

    abstract:PURPOSE:To assess the possibility of deriving an optimum intraocular lens (IOL) power after previous successful trabeculectomy. SETTING:Chang Gung Memorial Hospital, Linko, Taiwan. METHODS:The retrospective study included 1 eye of 22 patients who had cataract surgery after successful trabeculectomy performed by 1 sur...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2004.05.016

    authors: Tan HY,Wu SC

    更新日期:2004-12-01 00:00:00

  • Fungal keratitis after laser in situ keratomileusis.

    abstract::A 22-year-old woman presented with pain, redness, watering, and decrease in vision in her left eye 15 days after laser in situ keratomileusis for myopia. Slitlamp examination showed a central full-thickness infiltrate with hyphate edges. Microscopic examination of corneal scrapings from the edge and underneath the fla...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(99)00459-9

    authors: Sridhar MS,Garg P,Bansal AK,Sharma S

    更新日期:2000-04-01 00:00:00

  • Clinical outcomes after implantation of a new intrastromal corneal ring with a 210-degree arc length.

    abstract:PURPOSE:To report the clinical outcomes of implantation of a new Ferrara intrastromal corneal ring segment (ICRS) with a 210-degree arc length in eyes with keratoconus. SETTING:Private eye clinic, Belo Horizonte, Brazil METHODS:Statistical analysis included preoperative and postoperative uncorrected distance visual a...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2009.04.035

    authors: Ferrara P,Torquetti L

    更新日期:2009-09-01 00:00:00

  • Secondary closure of posterior continuous curvilinear capsulorhexis.

    abstract:PURPOSE:To examine the hypothesis that removing the center of the posterior capsule would prevent posterior capsular opacification (PCO). SETTING:Department of Ophthalmology, University Hospital Antwerp, Belgium. METHODS:A posterior continuous curvilinear capsulorhexis (CCC) was done before intraocular lens (IOL) imp...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(96)80068-x

    authors: Tassignon MJ,De Groot V,Smets RM,Tawab B,Vervecken F

    更新日期:1996-11-01 00:00:00

  • Ablation zone centration after photorefractive keratectomy and its effect on visual outcome.

    abstract:PURPOSE:To determine the relation between ablation zone decentration, measured by corneal topography, and visual and refractive outcome, contrast sensitivity, glare, and subjective reports of halos after photorefractive keratectomy (PRK). SETTING:Eye Foundation, University of Missouri-Kansas City School of Medicine. ...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 临床试验,杂志文章

    doi:10.1016/s0886-3350(96)80305-1

    authors: Deitz MR,Piebenga LW,Matta CS,Tauber J,Anello RD,DeLuca M

    更新日期:1996-07-01 00:00:00

  • Pinpoint anesthesia: a new approach to local ocular anesthesia.

    abstract::Current methods of local ocular anesthesia, including retrobulbar, peribulbar, and topical anesthesia, have distinct limitations and many possible, potentially serious complications. We present a new technique that provides rapid, thorough local ocular anesthesia and eliminates these potential complications. ...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(13)80186-1

    authors: Fukasaku H,Marron JA

    更新日期:1994-07-01 00:00:00

  • Femtosecond laser-assisted hyperopic laser in situ keratomileusis with tissue-saving ablation: analysis of 800 eyes.

    abstract:PURPOSE:To evaluate the results and complications of hyperopic laser in situ keratomileusis (LASIK) with a low-energy femtosecond laser and non-custom tissue-saving ablation profile. SETTING:Private practice, Siena, Italy. DESIGN:Case series. METHODS:Hyperopic eyes with a spherical equivalent (SE) between +1.0 and +...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2013.11.031

    authors: Leccisotti A

    更新日期:2014-07-01 00:00:00

  • Performance of the 1CU accommodating intraocular lens in relation to capsulorhexis size.

    abstract:PURPOSE:To assess the correlation between continuous curvilinear capsulorhexis (CCC) size and visual outcomes in patients with an accommodating intraocular lens (IOL). SETTING:Heidelberg IOL and Refractive Surgery Research Group, Department of Ophthalmology, Ruprecht-Karls-University of Heidelberg, Heidelberg, Germany...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2004.02.071

    authors: Vargas LG,Auffarth GU,Becker KA,Rabsilber TM,Holzer MP

    更新日期:2005-02-01 00:00:00

  • Sulfur hexafluoride injection for Descemet's membrane detachment in cataract surgery.

    abstract::Extensive Descemet's membrane detachment persisted after small incision cataract surgery in three patients. Unfolding and repositioning of Descemet's membrane by sodium hyaluronate (Healon) were followed by injection of sulfur hexafluoride 20% gas mixed with air to fill the anterior chamber. Initially, the gas bubble ...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(97)80013-2

    authors: Kremer I,Stiebel H,Yassur Y,Weinberger D

    更新日期:1997-12-01 00:00:00

  • Interpseudophakos Elschnig pearls associated with late hyperopic shift: a complication of piggyback posterior chamber intraocular lens implantation.

    abstract::We report 3 cases of bilateral piggyback lens implantation in which late hyperopic shift occurred associated with Elschnig pearl formation in the peripheral interface between the 2 lenses. ...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(99)00034-6

    authors: Shugar JK,Schwartz T

    更新日期:1999-06-01 00:00:00

  • Safety and predictability of laser in situ keratomileusis enhancement by flap reelevation in high myopia.

    abstract:PURPOSE:To evaluate the safety and predictability of laser in situ keratomileusis (LASIK) retreatment following primary procedures for high myopia and astigmatism. SETTING:Corneal Diseases and Excimer Laser Research Unit, Department of Ophthalmology, University of Dundee, Dundee, United Kingdom. METHODS:This prospect...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(01)00765-9

    authors: Brahma A,McGhee CN,Craig JP,Brown AD,Weed KH,McGhee J,Brown R

    更新日期:2001-04-01 00:00:00

  • Optic capture in complicated laser-assisted cataract surgery.

    abstract:UNLABELLED:An 84-year-old woman had routine laser-assisted cataract surgery with anterior laser capsulotomy and lens fragmentation. During hydropolishing of the posterior capsule, an unexpected posterior capsule rupture occurred without vitreous loss. The haptics of the intraocular lens (IOL) were implanted in the cili...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2015.06.016

    authors: Schultz T,Dick HB

    更新日期:2015-07-01 00:00:00

  • Evaluating and reporting astigmatism for individual and aggregate data.

    abstract:PURPOSE:To demonstrate the proper method for evaluating and reporting astigmatism for individual and aggregate data. SETTING:University of Texas Medical School and Cullen Eye Institute, Baylor College of Medicine, Houston, Texas, USA. METHODS:The surgically induced refractive change (SIRC) was determined for three da...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(98)80075-8

    authors: Holladay JT,Dudeja DR,Koch DD

    更新日期:1998-01-01 00:00:00

  • Intraocular lens power calculation for eyes with high and low average keratometry readings: Comparison between various formulas.

    abstract:PURPOSE:To compare the accuracy of intraocular lens power prediction for eyes with average keratometry (K) readings greater than 46.00 diopters (D) and lower than 42.00 D. SETTING:Ein-Tal Eye Center, Tel-Aviv, Israel. DESIGN:Retrospective case series. METHODS:Eyes having cataract extraction surgery with steep and fl...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2017.06.036

    authors: Reitblat O,Levy A,Kleinmann G,Lerman TT,Assia EI

    更新日期:2017-09-01 00:00:00

  • Precision and accuracy of an artificial anterior chamber system in obtaining corneal lenticules for lamellar keratoplasty.

    abstract:PURPOSE:To determine the precision and accuracy of an artificial anterior chamber and a manual microkeratome in obtaining corneal lenticules for lamellar keratoplasty. SETTING:Department of Ophthalmology, Cornea, External Diseases and Refractive Surgery Service, University of California Irvine, Irvine, California, USA...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(01)00896-3

    authors: Behrens A,Dolorico AM,Kara DT,Novick LH,McDonnell PJ,Chao LC,Wellik SR,Chuck RS

    更新日期:2001-10-01 00:00:00

  • Polar value analysis of refractive data.

    abstract:PURPOSE:To demonstrate the use of polar value analysis of surgically induced astigmatism (SIA). SETTING:Department of Ophthalmology, Arhus University Hospital, Arhus, Denmark. METHODS:Univariate polar value analysis of SIA was demonstrated for a single patient and for aggregate data. Bivariate polar value analysis wa...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(00)00799-9

    authors: Naeser K,Hjortdal J

    更新日期:2001-01-01 00:00:00

  • Extracapsular cataract extraction and intraocular lens implantation in eyes filled with silicone oil.

    abstract::Extracapsular cataract extraction with posterior chamber intraocular lens implantation was performed in five phakic eyes filled with silicone oil following vitreoretinal surgery. Silicone oil migration was prevented during surgery using an anterior chamber maintaining system and a self-sealed corneoscleral tunnel inci...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(96)80032-0

    authors: Weinberger D,Kremer I,Lichter H,Axer-Siegel R,Yassur Y

    更新日期:1996-05-01 00:00:00

  • Evaluation of intraocular pressure with Healon and Healon GV in sutureless cataract surgery with foldable lens implantation.

    abstract:PURPOSE:To evaluate transient increases in intraocular pressure (IOP) after use of high-viscosity viscoelastic agents in cataract surgery. SETTING:Military Hospital, Ulm, Germany. METHODS:In a prospective, randomized study, we evaluated IOP following cataract surgery using two different viscoelastic substances (Healo...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1016/s0886-3350(96)80224-0

    authors: Kohnen T,von Ehr M,Schütte E,Koch DD

    更新日期:1996-03-01 00:00:00

  • Efficacy and safety of combined cataract surgery with 2 trabecular microbypass stents versus ab interno trabeculotomy.

    abstract:PURPOSE:To compare the outcomes of combined cataract surgery with trabecular microbypass stents and ab interno trabeculotomy in patients with open-angle glaucoma. SETTING:University of Toronto, Toronto, Ontario, and University of Montreal, Montreal, Quebec, Canada, and Glaucoma Associates of Texas, Dallas, Texas, USA....

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2014.12.061

    authors: Khan M,Saheb H,Neelakantan A,Fellman R,Vest Z,Harasymowycz P,Ahmed II

    更新日期:2015-08-01 00:00:00

  • Recurrent iritis after implantation of an iris-fixated phakic intraocular lens for the correction of myopia Case report and clinicopathologic correlation.

    abstract::The iris-claw intraocular lens (IOL) was recently approved by the U.S. Food and Drug Administration for the correction of refractive disorders. Previous reports are not uniform regarding its potential to induce inflammatory reaction. We report the case of a young healthy patient who experienced persistent and intolera...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2006.02.079

    authors: Kleinmann G,Apple DJ,Mackool RJ

    更新日期:2006-08-01 00:00:00

  • Effect of partial and full correction of corneal spherical aberration on visual acuity and contrast sensitivity.

    abstract::A 60-year-old white man had cataract surgery with an AcrySof IQ intraocular lens (IOL) implanted in the right eye and a Tecnis IOL implanted in the left eye. The ocular spherical aberration (SA) target for a 6.0 mm pupil was +0.10 microm for the right eye and 0 microm for the left eye. After surgery, the ocular SA in ...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2008.12.041

    authors: Ferrer-Blasco T

    更新日期:2009-05-01 00:00:00

  • Endocapsular hyphema.

    abstract::A 67-year-old female developed an endocapsular hyphema after uncomplicated extracapsular cataract surgery. With a neodymium:YAG laser capsulotomy, we drained the blood into the vitreous and restored excellent visual acuity. We hypothesize that endocapsular hyphemas may fail to resorb because of sequestration of the cl...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(13)80316-1

    authors: Zagelbaum BM,Hersh PS

    更新日期:1993-05-01 00:00:00

  • Visual acuity from far to near and contrast sensitivity in eyes with a diffractive multifocal intraocular lens with a low addition power.

    abstract:PURPOSE:To compare visual acuity from far to near, contrast visual acuity, and acuity in the presence of glare (glare visual acuity) between an aspheric diffractive multifocal intraocular lens (IOL) with a low addition (add) power (+3.0 diopters) and a monofocal IOL. SETTING:Hayashi Eye Hospital, Fukuoka, Japan. METH...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2009.07.010

    authors: Hayashi K,Manabe S,Hayashi H

    更新日期:2009-12-01 00:00:00

  • Thin flap laser in situ keratomileusis: flap dimensions with the Moria LSK-One manual microkeratome using the 100-microm head.

    abstract:PURPOSE:To determine the predictability and consistency of corneal flap thickness, flap diameter, and hinge length with the modern 100 microm head of the Moria LSK-One manual microkeratome. SETTING:Private clinic, office-based practice. METHODS:Forty-two consecutive eyes with no previous surgery having thin flap lase...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2004.10.056

    authors: Duffey RJ

    更新日期:2005-06-01 00:00:00

  • Intraocular metallic-appearing foreign bodies after phacoemulsification.

    abstract::Intraocular metallic-appearing foreign bodies in the anterior segment were seen in six eyes after cataract extraction by two-handed phacoemulsification. These fragments produced no symptoms and had no clinically significant effect on visual function. Similar-appearing foreign bodies were experimentally produced by app...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(96)80078-2

    authors: Braunstein RE,Cotliar AM,Wirostko BM,Gorman BD

    更新日期:1996-11-01 00:00:00

  • Anterior periocular anesthesia: five years experience.

    abstract::Safe, effective administration of local anesthesia prior to ocular surgery is a primary concern of ophthalmologists and variations in the technique and method of delivering anesthesia have been developed. Retrobulbar anesthesia, although considered safe and effective, can have serious complications. Using periocular a...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(13)80861-9

    authors: Bloomberg LB

    更新日期:1991-07-01 00:00:00

  • Use of the anterior chamber maintainer in anterior segment surgery.

    abstract::Over a 12 month period, we used the anterior chamber maintainer (ACM) in cataract surgery in 258 patients; ages ranged from 15 to 95 years (mean 73 years). Surgery was performed using general or local anesthesia. The procedures were standard extracapsular cataract extraction (ECCE), mini-nuc ECCE, vectis extraction of...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(96)80214-8

    authors: Chawla HB,Adams AD

    更新日期:1996-03-01 00:00:00