Prospective study of porous-coated anatomic total hip arthroplasty.

Abstract:

:Seventy-five uncemented porous-coated total hip prostheses were implanted in 64 patients. The results were reviewed after a mean follow-up period of 47 months (range, 40-64 months). The mean preoperative rating was fair, and the mean postoperative rating was excellent. There were six dislocations. Ten patients had mild thigh pain at one year; by two years, the pain had resolved in six patients. Neither moderate nor severe limp nor significant loosening of beads was observed. Only one patient had progressive radiolucent lines. The high rate of dislocation may be related to a compromise of acetabular position to obtain bony fixation in acetabula early in the series. The clinical results were encouraging.

journal_name

Clin Orthop Relat Res

authors

Alexiades MM,Clain MR,Bronson MJ

subject

Has Abstract

pub_date

1991-08-01 00:00:00

pages

205-8

issue

269

eissn

0009-921X

issn

1528-1132

pub_type

杂志文章
  • Hallux valgus--etiology, anatomy, treatment and surgical considerations.

    abstract::The etiology of hallux valgus, method of patient selection, technique of carrying out a modified McBride procedure, and possible surgical pitfalls associated with the procedure are discussed. The results of the McBride procedure and the limitations that the authors feel should be placed upon the procedure were stresse...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:

    authors: Mann RA,Coughlin MJ

    更新日期:1981-06-01 00:00:00

  • Extensor function after medial gastrocnemius flap reconstruction of the proximal tibia.

    abstract:BACKGROUND:Reconstruction of the extensor mechanism after resection of the proximal tibia is challenging, and several methods are available. A medial gastrocnemius flap commonly is used, although it may be associated with an extensor lag. This problem also is encountered, although perhaps to a lesser extent, with other...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:10.1007/s11999-013-2851-8

    authors: Jentzsch T,Erschbamer M,Seeli F,Fuchs B

    更新日期:2013-07-01 00:00:00

  • Treatment of septic olecranon and prepatellar bursitis with percutaneous placement of a suction-irrigation system. A report of 12 cases.

    abstract::Ten cases of septic olecranon bursitis and two cases of septic prepatellar bursitis were treated in the period from 1975 to 1980 with antibiotics and percutaneous tube placement for suction-drainage and local antibiotic irrigation. All patients had positive bacterial cultures: Staphylococcus aureus in nine, beta-hemol...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:

    authors: Knight JM,Thomas JC,Maurer RC

    更新日期:1986-05-01 00:00:00

  • Effects of different commercial diets on several orthopedic experiments.

    abstract::In experiments involving disuse osteoporosis induced by plaster cast immobilization, 2 commonly used commercial feeds (Wayne Lab Blox and Purina Laboratory Chow) gave different results. Preliminary evidence suggests that this dichotomy of results is due to an interaction between metabolic changes caused by physiologic...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:

    authors: Martin RB

    更新日期:1979-01-01 00:00:00

  • Acetabular retroversion in military recruits with femoral neck stress fractures.

    abstract:UNLABELLED:Acetabular retroversion (AR) alters load distribution across the hip and is more prevalent in pathologic conditions involving the hip. We hypothesized the abnormal orientation and mechanical changes may predispose certain individuals to stress injuries of the femoral neck. We retrospectively reviewed the ant...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:10.1007/s11999-009-0969-5

    authors: Kuhn KM,Riccio AI,Saldua NS,Cassidy J

    更新日期:2010-03-01 00:00:00

  • Reliability of closed double helix electrode for functional electrical stimulation.

    abstract::The reliability of a closed double helix electrode in the lower limbs was studied. This electrode is an implanted intramuscular electrode and is used for a totally implantable functional electrical stimulation system. Eighty electrodes were evaluated retrospectively with a mean period of 15 months. The total implant t...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:

    authors: Kagaya H,Sharma M,Polando G,Marsolais EB

    更新日期:1998-01-01 00:00:00

  • Is the Enzyme-linked Immunosorbent Assay More Accurate Than the Lateral Flow Alpha Defensin Test for Diagnosing Periprosthetic Joint Infection?

    abstract:BACKGROUND:Alpha defensin was proposed as a new biomarker in synovial fluid for the diagnostic workup of failed joint prostheses. To our knowledge, no comparative study of the performance of the quantitative enzyme-linked immunosorbent assay (ELISA) and qualitative lateral flow alpha defensin test has been reported. Q...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:10.1097/CORR.0000000000000336

    authors: Sigmund IK,Yermak K,Perka C,Trampuz A,Renz N

    更新日期:2018-08-01 00:00:00

  • Destruction of rabbit knee hyaline cartilage associated with surface antigen-antibody interaction during the Arthus reaction of antigen-induced arthritis.

    abstract::Ultrastructural changes occurring in rabbit hyaline cartilage were studied during the early stages of antigen-induced arthritis. After one hour, small deposits of electron-dense material (EDM) were noted at depths up to about 3 micron from the surface. During subsequent stages, the number of EDM deposits did not incre...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:

    authors: Maeda M,Cooke TD

    更新日期:1984-11-01 00:00:00

  • Effects of metal-inlay thickness in polyethylene cups with metal-on-metal bearings.

    abstract::A way to prevent polyethylene wear in total hip replacements is to use metal-on-metal bearings. The cup design of these bearings may be a metal inlay in a polyethylene cup. However, these metal inlays are relatively thin and may deform on loading. The purpose of the current study was to determine whether these potenti...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:10.1097/00003086-200211000-00052

    authors: Verdonschot N,Vena P,Stolk J,Huiskes R

    更新日期:2002-11-01 00:00:00

  • Posterior kyphectomy for myelomeningocele with anterior placement of fixation: a retrospective review.

    abstract:BACKGROUND:Kyphosis in myelomeningocele is a rare and difficult problem. Many strategies have been used with no single procedure universally agreed on. Techniques involving anterior and posterior fixation may provide better fusion. QUESTIONS/PURPOSES:We describe a novel procedure for anteroposterior kyphectomy in pati...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:10.1007/s11999-010-1611-2

    authors: Comstock SA,Cook PC,Leahey JL,El-Hawary R,Hyndman JC

    更新日期:2011-05-01 00:00:00

  • Knee moments after unicompartmental knee arthroplasty during stair ascent.

    abstract:BACKGROUND:For unicompartmental knee arthroplasty (UKA), abnormal loading on the tibiofemoral joint could exacerbate knee osteoarthritis or implant wear. Joint moments are an indirect measure of such loading. However, little is known about knee moments of patients with UKA, tempering enthusiasm for its use. QUESTIONS/...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:10.1007/s11999-013-3128-y

    authors: Fu YC,Simpson KJ,Brown C,Kinsey TL,Mahoney OM

    更新日期:2014-01-01 00:00:00

  • Thigh pain and total hip arthroplasty: scintigraphy with 2.5-year followup.

    abstract::From January 1988 to May 1990, 60 patients underwent 68 total hip arthroplasties at the Eisenhower Army Medical Center. The authors excluded 11 patients (11 hips) in whom infection developed, who were lost to followup, or who had incomplete records, leaving 49 patients (57 hips) as the study population. The 35 uncemen...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:10.1097/00003086-199703000-00022

    authors: Herzwurm PJ,Simpson SL,Duffin S,Oswald SG,Ebert FR

    更新日期:1997-03-01 00:00:00

  • The use of lower tourniquet inflation pressures in extremity surgery facilitated by curved and wide tourniquets and an integrated cuff inflation system.

    abstract::Use of the lowest possible cuff inflation pressure should minimize the pathogenic effects of compression beneath the pneumatic tourniquet. Curved tourniquets (designed to fit conically shaped limbs) and wider tourniquets were associated with significantly lower arterial occlusion pressure (AOP) than standard, straight...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:

    authors: Pedowitz RA,Gershuni DH,Botte MJ,Kuiper S,Rydevik BL,Hargens AR

    更新日期:1993-02-01 00:00:00

  • Vertebral osteochondrosis (Scheuermann's kyphosis).

    abstract::Scheuermann's juvenile kyphosis may be considered a form of vertebral osteochondrosis. Although the etiology remains unknown, the ultimate effect is a disorderliness of vertebral growth in the growth plate cartilage. The biomechanical effects of increased kyphosis on saggital plane deformity, especially in a growing c...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:

    authors: Bradford DS

    更新日期:1981-07-01 00:00:00

  • Hypoplasia of the fibula.

    abstract::Fibular hypoplasia occurs in differing degrees of severity with fibular hemimelia as its most severe form. Normally the distal epiphyseal plate of the fibula is at the same level as the distal end of the distal tibial epiphysis, whereas the tip of the proximal fibular epiphysis is level with the proximal tibial epiphy...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:

    authors: Bohne WH,Root L

    更新日期:1977-06-01 00:00:00

  • A minimally invasive stabilizing system for dorsal pelvic ring injuries.

    abstract:BACKGROUND:Open reduction and stabilization of dorsal pelvic ring injuries is accompanied by a high rate of soft tissue complications. Minimally invasive techniques have the potential to decrease soft tissue trauma, but the risk of iatrogenic nerve and vessel damage through the reduced surgical exposure should be consi...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:10.1007/s11999-011-1922-y

    authors: Dienstknecht T,Berner A,Lenich A,Nerlich M,Fuechtmeier B

    更新日期:2011-11-01 00:00:00

  • Bone-block iliotibial band reconstruction for anterior cruciate insufficiency. Follow-up note and minimum five-year follow-up period.

    abstract::Sixty-two of 71 patients (87%) who received a bone-block iliotibial band transfer were followed with a minimum follow-up period of five years (range, 5-10 years). Sixteen of the originally studied knees were examined with an average follow-up period of 104 months (range, 90-120 months). A second group of 46 knees was ...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:

    authors: Windsor RE,Insall JN

    更新日期:1990-01-01 00:00:00

  • "Modes of failure" of cemented stem-type femoral components: a radiographic analysis of loosening.

    abstract::In view of the increasing incidence of stem-type femoral component loosening, a detailed retrospective radiographic zonal analysis of 389 total hip replacements indicated a 19.5% incidence (76 hips) of radiological evidences of mechanical looseness, i.e., fractured acrylic cement and/or a radiolucent gap at the stem-c...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:

    authors: Gruen TA,McNeice GM,Amstutz HC

    更新日期:1979-06-01 00:00:00

  • Quantitative assessment of glenohumeral translation.

    abstract::Cutaneous electromagnetic position sensors were used to quantify anteroposterior laxity of the shoulder. Forty-three female athletes were tested (27 were soccer players and 16 were swimmers). The athletes had a mean age of 18.8 years (range, 17-24 years), and all were free of shoulder disorders. Dominant and nondomina...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:10.1097/00003086-200207000-00012

    authors: Tibone JE,Lee TQ,Csintalan RP,Dettling J,McMahon PJ

    更新日期:2002-07-01 00:00:00

  • Nonconsolidated polyethylene particles and oxidation in Charnley acetabular cups.

    abstract::Nonconsolidated particles of ultra high molecular weight polyethylene are believed to be defects that adversely can affect the wear performance of total joint prostheses. The present study was done to determine the number, size, and distribution of these particles and to determine if their presence correlated with wea...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:

    authors: Li S,Chang JD,Barrena EG,Furman BD,Wright TM,Salvati E

    更新日期:1995-10-01 00:00:00

  • Classification of ankle fractures: the Lauge-Hansen or AO system?

    abstract::Lauge-Hansen's system of classification of ankle fractures has been of pioneering importance and when correctly employed has improved the results of conservative treatment. Weber's classification scheme introduced by AO is simpler and more suited for surgical than nonoperative therapy. Both systems have deficiencies. ...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:

    authors: Lindsjö U

    更新日期:1985-10-01 00:00:00

  • Artificial impaction in hip fracture. By F. J. Cotton, 1911.

    abstract::Frederic Jay Cotton (Fig. 1) was born in Prescott, Wisconsin, and educated at Harvard. After postgraduate study in New York and in Europe, he returned to Boston where he had an association with most of the important hospitals. In addition to great surgical talent, he also was an able administrator and medical politici...

    journal_title:Clinical orthopaedics and related research

    pub_type: 传,古典文章,历史文章,杂志文章

    doi:

    authors: Cotton FJ

    更新日期:1987-12-01 00:00:00

  • Percutaneous fixation of pelvic ring disruptions.

    abstract::Percutaneous pelvic fixation is possible because intraoperative fluoroscopic imaging and other technologies have been refined. Anterior and posterior unstable pelvic ring disruptions are amenable to percutaneous fixation after closed manipulation or open reduction. Stable and safe fixation is achieved only after an ac...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章,评审

    doi:10.1097/00003086-200006000-00004

    authors: Routt ML Jr,Nork SE,Mills WJ

    更新日期:2000-06-01 00:00:00

  • Osteolysis: medical and surgical approaches.

    abstract::Osteolysis is defined as the process of progressive destruction of periprosthetic bony tissue, characterized on serial radiographs as progressive radiolucent lines and/or cavitation at the implant-bone or cement-bone interface. Without proper treatment, osteolysis may progress to aseptic loosening and catastrophic fai...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章,评审

    doi:

    authors: Saleh KJ,Thongtrangan I,Schwarz EM

    更新日期:2004-10-01 00:00:00

  • Femoral Component Varus Malposition is Associated with Tibial Aseptic Loosening After TKA.

    abstract:BACKGROUND:The notion that neutral alignment is mandatory to assure long-term durability after TKA has been based mostly on short-film studies. However, this is challenged by recent long-film studies. QUESTIONS/PURPOSES:We conducted this long-film study to know (1) whether the risk of aseptic revision for nontraumatic...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:10.1007/s11999.0000000000000012

    authors: Lee BS,Cho HI,Bin SI,Kim JM,Jo BK

    更新日期:2018-02-01 00:00:00

  • Fixation, polyethylene wear, and pelvic osteolysis in primary total hip replacement.

    abstract::A multicenter retrospective review was performed analyzing 1081 primary total hip replacements in 944 patients using the Harris Galante-I cementless acetabular component with screw fixation. All patients were followed up for a minimum of 5 years with a mean followup of 81 months. Linear polyethylene wear averaged 0.11...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章,多中心研究

    doi:10.1097/00003086-199912000-00016

    authors: Maloney WJ,Galante JO,Anderson M,Goldberg V,Harris WH,Jacobs J,Kraay M,Lachiewicz P,Rubash HE,Schutzer S,Woolson ST

    更新日期:1999-12-01 00:00:00

  • Osteoid osteoma of the femoral neck stimulating an inflammatory synovitis.

    abstract::The case report presents a nine-year-old child with an osteoid osteoma of the femoral neck, simulating an inflammatory synovitis. Osteoid osteoma is a common benign bone tumor. However, when intracapsular lesions occur they may pose a diagnostic challenge. Nonspecific clinical signs and symptoms, such as inflammatory ...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:

    authors: Alani WO,Bartal E

    更新日期:1987-10-01 00:00:00

  • Osteoarthritis associated with a ball-and-socket ankle joint. A case report.

    abstract::A ball-and-socket joint is an unusual disturbance of normal ankle development. Previous reports have noted good function and the absence of osteoarthritic change in ankles with this configuration. A 50-year-old man with no history of injury developed an osteoarthritic ball-and-socket deformity of the ankle joint. Asso...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:

    authors: Dennis DA,Clayton ML,Ferlic DC

    更新日期:1987-02-01 00:00:00

  • Upper extremity surgery in stroke patients.

    abstract::Surgical procedures are performed on the nonfunctional upper extremity following stroke to correct spastic flexion contractures that cause pain or prevent adequate hygiene. In the upper extremity surgical procedures are most commonly performed to improve extension at the wrist, fingers or thumb. If the deformity is pr...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:

    authors: Waters RL

    更新日期:1978-03-01 00:00:00

  • Posttransplantation lymphoproliferative disorder in the knee.

    abstract::Lymphoproliferative disorders with primary presentation in a joint are extremely rare. Posttransplantation lymphoproliferative disorders are commonly extranodal at presentation but rarely involve joint structures. The authors describe a fatal case of posttransplantation lymphoproliferative disorder presenting in the k...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:

    authors: Pineda R,Wyard L,Tietjen R,Sieber S

    更新日期:1998-05-01 00:00:00