Internal fixation of traumatic diastasis of pubic symphysis: is plate removal essential?

Abstract:

INTRODUCTION:Internal fixation of the traumatic diastasis of symphysis pubis is an integral part of the definitive management of pelvic ring injuries. Both functional outcome and long term physiological effects of plate retention have not been clearly addressed and no specific indications regarding implant removal have been proposed in the literature. MATERIALS AND METHODS:We reviewed 74 patients (18 females and 56 males), with an average age of 40.6 (16-75) years, who underwent open reduction and internal fixation (ORIF) of the pubic symphysis. Except from the demographic data many other parameters like suprapubic pain, sexual disturbance, impotence and dyspareunia were taken under consideration. Furthermore, any correlation between implant failure and functional impairment was recorded and the subject of implant removal in pregnant women was examined. Health outcome was assessed according to EuroQol 5-D (EQ-5D) questionnaire. Mean follow up: 41.7 (28-89) months. RESULTS:Suprapubic pain was present in ten patients. Three men developed neurogenic impotence and one woman had deep dyspareunia. None of these symptoms were related to implant status. Three of the four females who had uncomplicated pregnancy in the post-stabilization period had the plate in situ. Implant failure was seen in four patients but they remained asymptomatic. EQ-5D questionnaire revealed high satisfaction scores among young women and men of all age groups. CONCLUSION:This study supports the view that routine removal of the plate is not essential. The issue of whether the implant needs to be removed in women of childbearing age requires further investigation.

authors

Giannoudis PV,Chalidis BE,Roberts CS

doi

10.1007/s00402-007-0429-1

subject

Has Abstract

pub_date

2008-03-01 00:00:00

pages

325-31

issue

3

eissn

0936-8051

issn

1434-3916

journal_volume

128

pub_type

杂志文章
  • Bone and muscle mass after femoral neck fracture. A controlled quantitative computed tomography study of osteosynthesis versus primary total hip arthroplasty.

    abstract::The cortical bone mineral density (BMD), bone volume, bone mass and muscle volume of the thigh, and the BMD of the distal femur and proximal tibia were measured quantified by quantitative computed tomography (QCT) after an operation for a displaced femoral neck fracture. Twenty patients were randomized to osteosynthes...

    journal_title:Archives of orthopaedic and trauma surgery

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1007/BF00387579

    authors: Neander G,Adolphson P,von Sivers K,Dahlborn M,Dalén N

    更新日期:1997-01-01 00:00:00

  • A model for assessing the rotational stability of uncemented femoral implants.

    abstract::Permanent secondary stability of the uncemented femoral stem of hip prostheses can only be achieved once primary rotational and axial stability has been ensured. Rotational stability means that the stem is resistant to the articular forces that induce rotation around the implant's longitudinal axis. The 10-year surviv...

    journal_title:Archives of orthopaedic and trauma surgery

    pub_type: 杂志文章

    doi:10.1007/s004020000215

    authors: Effenberger H,Heiland A,Ramsauer T,Plitz W,Dorn U

    更新日期:2001-01-01 00:00:00

  • How to predict requisite nail length in tibial fractures.

    abstract::In a retrospective study involving 59 patients, a regression equation between nail length and body weight has been computed as follows: nail length = -5.05729 + 0.222 x body height (probability value for intercept P = 0.24327 and slope P = 0.0000). Graphic analysis of the residuals gave a randomly scattered blob of da...

    journal_title:Archives of orthopaedic and trauma surgery

    pub_type: 杂志文章

    doi:10.1007/BF00441830

    authors: Fischmeister MF,Lang T,Reichl C,Wechselberger C

    更新日期:1994-01-01 00:00:00

  • Management of proximal humeral fractures by the Ilizarov external fixator.

    abstract:INTRODUCTION:External fixation can be performed in poor bone and soft tissue conditions, and can be used in patients with poor general conditions or multiple injuries as a rapid, mini-invasive procedure. The purpose of the current study was to evaluate the effectiveness and safety of the Ilizarov external fixator in th...

    journal_title:Archives of orthopaedic and trauma surgery

    pub_type: 杂志文章

    doi:10.1007/s00402-017-2749-0

    authors: Meselhy MA,Singer MS

    更新日期:2017-09-01 00:00:00

  • Single-row and transosseous sutures for supraspinatus tendon tears: a retrospective comparative clinical and strength outcome at 2-year follow-up.

    abstract:INTRODUCTION:Rotator cuff tears commonly necessitate surgical repair; however, the optimal technique for repair continues to be investigated. Recently, double-row repairs have been considered an alternative to single-row repair, allowing a greater coverage area for healing and a possibly stronger repair. AIM:We perfor...

    journal_title:Archives of orthopaedic and trauma surgery

    pub_type: 杂志文章

    doi:10.1007/s00402-016-2558-x

    authors: Panella A,Amati C,Moretti L,Damato P,Notarnicola A,Moretti B

    更新日期:2016-11-01 00:00:00

  • Frozen shoulder--treatment and results.

    abstract::Even today the aetiology of the frozen shoulder is still under discussion. At the Orthopaedic Department of the Medizinische Hochschule Hannover, 118 persons with a frozen shoulder were treated as in- or outpatients between 1980 and 1988. We investigated the results of two different specific therapy concepts. Most of ...

    journal_title:Archives of orthopaedic and trauma surgery

    pub_type: 杂志文章

    doi:10.1007/BF00422832

    authors: Melzer C,Wallny T,Wirth CJ,Hoffmann S

    更新日期:1995-01-01 00:00:00

  • Three-dimensional computed tomography reconstruction improves the reliability of tibial pilon fracture classification and preoperative surgical planning.

    abstract:PURPOSE:In the present study, we aimed to evaluate the impact of two-dimensional multi-planar computed tomography (2D-MP-CT) scans and three-dimensional surface rendering computed tomography reconstruction (3D-SR-CT) on the inter- and intra-observer reliability of four commonly used classification systems for tibial pi...

    journal_title:Archives of orthopaedic and trauma surgery

    pub_type: 杂志文章

    doi:10.1007/s00402-019-03259-8

    authors: Keiler A,Riechelmann F,Thöni M,Brunner A,Ulmar B

    更新日期:2020-02-01 00:00:00

  • Results of humeral stump angulation osteotomy.

    abstract::Between 1972 and 1989 angulation osteotomy was performed on 61 patients with long humeral stumps at the Orthopaedic Hospital of Heidelberg University. Marquardt's surgical technique was used to improve function in patients who had undergone above-elbow amputation and in children with a risk of terminal osseous overgro...

    journal_title:Archives of orthopaedic and trauma surgery

    pub_type: 杂志文章

    doi:10.1007/BF00390049

    authors: Neusel E,Traub M,Bläsius K,Marquardt E

    更新日期:1997-01-01 00:00:00

  • Plasty of tendon with dura mater. Experimental study.

    abstract::The authors present an experimental study of 30 rats, in which human dura mater preserved in glycerin was used to repair gaps in the Achilles tendon. The animals were killed 8 weeks after the surgery and evaluated by gross and microscopic examination. The results showed that the dura mater did not cause foreign-body r...

    journal_title:Archives of orthopaedic and trauma surgery

    pub_type: 杂志文章

    doi:10.1007/BF00440572

    authors: Pessoa de Barros TE,Guarniero R,Chih CL,Choi PS,Rodrigues CJ

    更新日期:1990-01-01 00:00:00

  • Contact mechanics after mattress suture repair of medial meniscus vertical longitudinal tear: an in vitro study.

    abstract:PURPOSE:Most studies have concentrated on the changes in contact pressure and area on the tibiofemoral joint. This study compared the contact mechanics underneath the medial meniscus of a repaired vertical longitudinal tear with that of the intact or the torn ones. METHODS:In this controlled laboratory study, a 1000 N...

    journal_title:Archives of orthopaedic and trauma surgery

    pub_type: 杂志文章

    doi:10.1007/s00402-020-03428-0

    authors: Chen Z,Zhang H,Luo H,Yang R,Zhang Z,Jiang C,Hou J,Zhou Y,Xu Y,Song B,Li W

    更新日期:2020-09-01 00:00:00

  • Long-term outcomes after different types of Horne and Tanzer olecranon fractures.

    abstract:BACKGROUND:It is unclear whether the outcomes differ after different Horne and Tanzer types of olecranon fractures. MATERIALS AND METHODS:We evaluated 40 men and 55 women with isolated olecranon fractures, journals and radiographs from fracture event. The fractures were classified according to Horne and Tanzer. After ...

    journal_title:Archives of orthopaedic and trauma surgery

    pub_type: 杂志文章

    doi:10.1007/s00402-020-03453-z

    authors: Hasserius R,Hertervig F,Josefsson PO,Besjakov J,von Schewelov T

    更新日期:2020-04-23 00:00:00

  • Is hospital volume associated with length of stay, re‑admissions and reoperations for total hip replacement? A population‑based register analysis of 78 hospitals and 54,505 replacements.

    abstract:INTRODUCTION:Hospital volume has been suggested to be a significant determinant of the outcome of joint replacement surgery. We updated previously published data on the effect of hospital volume on length of stay, re-admissions, and reoperations for total hip replacement (THR) at the population level in Finland. MATER...

    journal_title:Archives of orthopaedic and trauma surgery

    pub_type: 杂志文章

    doi:10.1007/s00402-013-1860-0

    authors: Pamilo KJ,Peltola M,Mäkelä K,Häkkinen U,Paloneva J,Remes V

    更新日期:2013-12-01 00:00:00

  • Comparison of treatment of oblique and spiral metacarpal and phalangeal fractures with mini plate plus screw or screw only.

    abstract:INTRODUCTION:We aimed to compare results of treatment of oblique-spiral metacarpal and phalangeal fractures with screw only or mini plate plus screw, respectively. METHODS:A total of 43 patients who were operated with a diagnosis of displaced, irreducible, unstable, rotational oblique-spiral metacarpal and proximal ph...

    journal_title:Archives of orthopaedic and trauma surgery

    pub_type: 杂志文章

    doi:10.1007/s00402-015-2164-3

    authors: Başar H,Başar B,Başçı O,Topkar OM,Erol B,Tetik C

    更新日期:2015-04-01 00:00:00

  • Galvanic reactions between cerclage wires and Kuntscher nails.

    abstract::Four patients are presented who had closed femoral shaft fractures and developed either extensive callus or osteomyelitis following open Kuntscher nailing and cerclage wiring of a butterfly fragment. Both the Kuntscher nail and cerclage wire are made of stainless steel but with different percentages of constituent ele...

    journal_title:Archives of orthopaedic and trauma surgery

    pub_type: 杂志文章

    doi:10.1007/BF00454737

    authors: Taylor MT,Wilson PE

    更新日期:1994-01-01 00:00:00

  • Complications of implant removal after healed hip fractures.

    abstract:INTRODUCTION:Osteosynthesis of pertrochanteric fractures is one of the most frequently performed procedures in orthopaedic trauma care. Auto-dynamization during fracture healing can lead to lateralization of the screw or blade. This can cause debilitating complaints, which sometimes necessitate the removal of the screw...

    journal_title:Archives of orthopaedic and trauma surgery

    pub_type: 杂志文章

    doi:10.1007/s00402-020-03435-1

    authors: Driessen MLS,Goessens MLMJ

    更新日期:2020-11-01 00:00:00

  • Patient-reported outcome assessment after total joint replacement: comparison of questionnaire completion times on paper and tablet computer.

    abstract:INTRODUCTION:Patient-reported outcome (PRO) assessment is becoming increasingly important after joint replacement surgery. However, PRO data collection, questionnaire handling, and data processing are time consuming and costly process. The aim of our study was to evaluate the efficiency of PRO assessment using tablet c...

    journal_title:Archives of orthopaedic and trauma surgery

    pub_type: 杂志文章

    doi:10.1007/s00402-015-2222-x

    authors: Kesterke N,Egeter J,Erhardt JB,Jost B,Giesinger K

    更新日期:2015-07-01 00:00:00

  • The phenomenon and efficiency of ligamentotaxis after dorsal stabilization of thoracolumbar burst fractures.

    abstract::Thirty-six consecutive patients with burst fractures of the thoracolumbar spine and with a fractured posterior vertebral surface dislocated into the spinal canal without neurological symptoms were treated with the AO internal fixator. Computed tomography-aided planimetry of the spinal canal was undertaken preoperative...

    journal_title:Archives of orthopaedic and trauma surgery

    pub_type: 杂志文章

    doi:10.1007/s00402-005-0065-6

    authors: Mueller LA,Mueller LP,Schmidt R,Forst R,Rudig L

    更新日期:2006-08-01 00:00:00

  • Antibiotic prophylaxis in lower-extremity amputations due to ischemia. A prospective, randomized trial of cephalothin versus methicillin.

    abstract::The efficiency of prophylactic antibiotic therapy in amputation surgery was studied in a prospective, randomized trial of a first-generation cephalosporin (cephalothin) compared with a narrow-spectrum beta-lactam stable penicillin (methicillin). Eighty-eight patients received cephalothin 2 g X 4 on the day of operatio...

    journal_title:Archives of orthopaedic and trauma surgery

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1007/BF00439382

    authors: Thomsen S,Jakobsen BW,Wethelund JO,Dalsgaard J,Gregersen HN,Lucht U

    更新日期:1990-01-01 00:00:00

  • Practicability of a locking plate for difficult pathologies of the scaphoid.

    abstract:INTRODUCTION:Headless compressions screws are the most implanted devices for scaphoid fractures and nonunions. For cases when screw osteosynthesis is not possible, a special locking plate for scaphoid reconstruction has been developed. The purpose of this study was to evaluate the safety and practicability of this devi...

    journal_title:Archives of orthopaedic and trauma surgery

    pub_type: 杂志文章

    doi:10.1007/s00402-019-03196-6

    authors: Mehling IM,Arsalan-Werner A,Wingenbach V,Seegmüller J,Schlageter M,Sauerbier M

    更新日期:2019-08-01 00:00:00

  • Acetabular development following early treatment of hip dysplasia by Pavlik harness.

    abstract::One hundred sixty-two neonates with sonographically diagnosed developmental dysplasia of the hip (200 hips) according to the method of Graf were treated with a Pavlik harness until sonographic maturation was reached. Eight patients (12 hips) treated with closed reduction and retention in a bilateral hip spica cast wer...

    journal_title:Archives of orthopaedic and trauma surgery

    pub_type: 杂志文章

    doi:10.1007/BF00443818

    authors: Rachbauer F,Sterzinger W,Klestil T,Krismer M,Frischhut B

    更新日期:1994-01-01 00:00:00

  • Expandable vertebral body replacement in patients with thoracolumbar spine tumors.

    abstract:INTRODUCTION:The objectives of surgical interventions for tumoral lesions of the spine include the establishment and improvement of tumor-related symptoms. Anterior tumor resection followed by reconstruction indicated if surgical treatment allowed a marginal removal of the tumor or could extend the individual survival ...

    journal_title:Archives of orthopaedic and trauma surgery

    pub_type: 杂志文章

    doi:10.1007/s00402-005-0057-6

    authors: Ernstberger T,Kögel M,König F,Schultz W

    更新日期:2005-12-01 00:00:00

  • Biomechanical analysis of hip function after Chiari pelvic osteotomy.

    abstract::The reasons are discussed for differences in functional results of the pelvic osteotomy after Chiari, regardless of the fact that the CE and AC angles were equal in all patients. When lateralization and distal displacement of the greater trochanter were performed in addition to the pelvic osteotomy, the functional res...

    journal_title:Archives of orthopaedic and trauma surgery

    pub_type: 杂志文章

    doi:10.1007/BF00932167

    authors: Korzinek K,Muftić O

    更新日期:1989-01-01 00:00:00

  • A systematic comparison of the closed shoulder reduction techniques.

    abstract:PURPOSE:To identify the optimal technique for closed reduction for shoulder instability, based on success rates, reduction time, complication risks, and pain level. METHODS:A PubMed and EMBASE query was performed, screening all relevant literature of closed reduction techniques mentioning the success rate written in E...

    journal_title:Archives of orthopaedic and trauma surgery

    pub_type: 杂志文章,评审

    doi:10.1007/s00402-017-2648-4

    authors: Alkaduhimi H,van der Linde JA,Willigenburg NW,van Deurzen DFP,van den Bekerom MPJ

    更新日期:2017-05-01 00:00:00

  • The longer pull-out suture as a transmission suture for early active motion of repaired flexor tendon at the proximal zone-2.

    abstract:OBJECTIVES:The purpose of the current study was to clinically evaluate the technique of longer pull-out suture as a transmission suture for early active motion after flexor tendon repair in the proximal zone-2. METHOD:Eleven patients (eight adult male, two adult female and one child) with 19 proximal zone II flexor te...

    journal_title:Archives of orthopaedic and trauma surgery

    pub_type: 杂志文章

    doi:10.1007/s00402-010-1238-5

    authors: Okçesiz IE,Ege A,Turhan E,Songür M,Bayar A,Keser S

    更新日期:2011-04-01 00:00:00

  • Malignant Natural-Killer cell neoplasm presenting as a mucous cyst on the distal interphalangeal joint of the finger.

    abstract::This case report describes a very rare and highly malignant type of lymphoma, which presents as a mucous cyst on the finger. The cyst was excised and the specimen pathohistologically analyzed. The analysis revealed the presence of a Natural-Killer cell neoplasm. This case illustrates and stresses the importance of a p...

    journal_title:Archives of orthopaedic and trauma surgery

    pub_type: 杂志文章

    doi:10.1007/s00402-008-0794-4

    authors: Unglaub F,Loos B,Wolf MB,Dragu A,Amann K,Horch RE

    更新日期:2009-12-01 00:00:00

  • Posterior-only surgical correction with heavy halo-femoral traction for the treatment of extremely severe and rigid adolescent idiopathic scoliosis (> 130°).

    abstract:INTRODUCTION:The treatment of extremely severe and rigid spinal deformities was a great surgical challenge. Pulmonary impairment often occurred, which increased the challenges to already daunting surgical approaches. The present study was performed to evaluate the safety and efficacy of posterior-only surgical correcti...

    journal_title:Archives of orthopaedic and trauma surgery

    pub_type: 杂志文章

    doi:10.1007/s00402-020-03720-z

    authors: Zhang HQ,Deng A,Guo CF,Tang MX,Alonge E

    更新日期:2021-01-23 00:00:00

  • The distal tibiofibular syndesmosis during passive foot flexion. RSA-based study on intact, ligament injured and screw fixed cadaver specimens.

    abstract:INTRODUCTION:The aim of the study was to investigate the kinematics of the distal tibiofibular syndesmosis in intact and ligament injured ankles and to assess how effective is the syndesmotic screw in restraining mortise width variations during passive foot flexion. MATERIALS AND METHODS:The trials were carried out on...

    journal_title:Archives of orthopaedic and trauma surgery

    pub_type: 杂志文章

    doi:10.1007/s00402-006-0131-8

    authors: Bragonzoni L,Russo A,Girolami M,Albisinni U,Visani A,Mazzotti N,Marcacci M

    更新日期:2006-07-01 00:00:00

  • Preoperative templating of femoral components on plain X-rays. Rotational evaluation with synthetic X-rays on ORTHODOC.

    abstract:INTRODUCTION:Preoperative femoral templating for total hip arthroplasty (THA) has been performed by antero-posterior radiographs of both hips which should be taken with the femur rotated internally to reduce the effect of femoral anteversion. However, there is no criterion to evaluate the optimal rotated radiograph. He...

    journal_title:Archives of orthopaedic and trauma surgery

    pub_type: 杂志文章

    doi:10.1007/s00402-007-0349-0

    authors: Hananouchi T,Sugano N,Nakamura N,Nishii T,Miki H,Yamamura M,Yoshikawa H

    更新日期:2007-07-01 00:00:00

  • A new guide system for posteromedial portal in arthroscopic knee surgery.

    abstract::A view through the posteromedial portal is necessary to observe the posterior portion of the knee joint such as the tibial attachment of the posterior cruciate ligament (PCL) or the posterior horn of the medial meniscus, which is barely, visible through anterior portals. Especially in arthroscopic PCL reconstruction, ...

    journal_title:Archives of orthopaedic and trauma surgery

    pub_type: 杂志文章

    doi:10.1007/s004020050304

    authors: Ochi M,Adachi N,Sumen Y,Uchio Y,Iwasa J

    更新日期:1998-01-01 00:00:00

  • A prospective, comparative study of subacromial corticosteroid injection and subacromial corticosteroid injection plus suprascapular nerve block in patients with shoulder impingement syndrome.

    abstract:INTRODUCTION:Efforts are recently focused on the management of shoulder impingement syndrome (SIS) with a conservative and targeted approach because of its psychosocial impact, reduction in the quality of life, the cost to the economy and its negative effect on daily activities. Therefore, many studies have been design...

    journal_title:Archives of orthopaedic and trauma surgery

    pub_type: 杂志文章

    doi:10.1007/s00402-020-03455-x

    authors: Yilmaz E

    更新日期:2020-04-30 00:00:00