No-history method of intraocular lens power calculation for cataract surgery after myopic laser in situ keratomileusis.

Abstract:

PURPOSE:To prospectively evaluate the no-history method for intraocular lens (IOL) power calculation in 15 cataractous eyes that had previous myopic laser in situ keratomileusis (LASIK) and for which the pre-LASIK K-readings were not available. SETTING:Private practice, Lynwood, California, USA. METHODS:The predicted IOL power was calculated in each case. Also calculated were the mean arithmetic and absolute IOL predictor errors, range of the prediction errors, and number of eyes in which the error was within +/-1.00 diopter (D). RESULTS:The mean arithmetic IOL prediction error was -0.003 D +/- 0.63 (SD), and the mean absolute IOL prediction error was 0.55 +/- 0.31 D (range -0.89 to +1.05 D). Fourteen eyes (93.3%) were within +/-1.00 D. The results of the Shammas post-LASIK formula compared favorably to the results obtained with the optimized Holladay 1 (P = .42), Hoffer Q (P = .25), Haigis (P = .30), and Holladay 2 (P = .19) formulas and were better than the results obtained with the optimized SRK/T formula (P = .0005). CONCLUSION:The no-history method is a viable alternative for IOL power calculation after myopic LASIK when the refractive surgery data are not available.

authors

Shammas HJ,Shammas MC

doi

10.1016/j.jcrs.2006.08.045

subject

Has Abstract

pub_date

2007-01-01 00:00:00

pages

31-6

issue

1

eissn

0886-3350

issn

1873-4502

pii

S0886-3350(06)01221-1

journal_volume

33

pub_type

杂志文章
  • Bilateral high hyperopia after radial keratotomy.

    abstract::A patient with myopia and astigmatism in the ideal range for correction by radial keratotomy had surgery on both eyes. Postoperatively, she developed bilateral high hyperopia, with a +9.00 diopter refractive error (OD) and a spherical equivalent of +8.75 diopters (OS). Her best corrected visual acuity dropped one line...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(13)80289-1

    authors: Waisberg Y

    更新日期:1993-01-01 00:00:00

  • Diurnal variations in keratometry and refraction with intracorneal ring segments.

    abstract:PURPOSE:To study refraction variations during the day in eyes with intrastromal corneal ring segments (ICRS) to correct low myopia. SETTING:Monticelli Clinic, Marseille, France. METHODS:Thirteen eyes with ICRS were included in the study; the ICRS was explanted from 3 eyes because of undercorrection. The minimum follo...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(99)00129-7

    authors: Baïkoff G,Maia N,Poulhalec D,Fontaine A,Giusiano B

    更新日期:1999-08-01 00:00:00

  • Entry of antibiotic ointment into the anterior chamber after uneventful phacoemulsification.

    abstract::A 77-year-old woman had uneventful phacoemulsification. Postoperative examination revealed that chloramphenicol ointment instilled in the conjunctival fornix had entered the anterior chamber and smeared the intraocular lens (IOL). Immediate surgical removal of the ointment with IOL exchange was performed. The eye sett...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(02)01503-1

    authors: Aralikatti AK,Needham AD,Lee MW,Prasad S

    更新日期:2003-03-01 00:00:00

  • Persistent corneal fibrosis after explantation of a small-aperture corneal inlay.

    abstract::The KAMRA small-aperture corneal inlay can compensate for presbyopia. A small number of complications have been reported, including glare, halos, decentration, iron deposition, compromised distance and night vision, infectious keratitis and reversal corneal haze. We describe a case of corneal fibrosis after small-aper...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2018.11.003

    authors: Romito N,Basli E,Goemaere I,Borderie V,Laroche L,Bouheraoua N

    更新日期:2019-03-01 00:00:00

  • Patient pain during stretching of small pupils in phacoemulsification performed using topical anesthesia.

    abstract:PURPOSE:To assess the pain experienced by patients with small pupils during pupil stretching in phacoemulsification performed using topical anesthesia. SETTING:Royal Victoria Eye & Ear Hospital and Mater Misericordiae University Hospital, Dublin, Ireland. METHODS:This was a prospective study that included 26 eyes wit...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2005.02.044

    authors: O'Brien PD,Fitzpatrick P,Power W

    更新日期:2005-09-01 00:00:00

  • Visual outcomes and patient satisfaction after cataract surgery with toric multifocal intraocular lens implantation.

    abstract:PURPOSE:To evaluate visual outcomes and patient satisfaction after toric multifocal intraocular lens (IOL) implantation in patients with cataract and corneal astigmatism. SETTING:University Eye Clinic Maastricht, The Netherlands. DESIGN:Cohort study. METHODS:Patients with cataract, corneal astigmatism, and a motivat...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2011.05.041

    authors: Visser N,Nuijts RM,de Vries NE,Bauer NJ

    更新日期:2011-11-01 00:00:00

  • Prophylaxis of postoperative endophthalmitis following cataract surgery: results of the ESCRS multicenter study and identification of risk factors.

    abstract:PURPOSE:To identify risk factors and describe the effects of antibiotic prophylaxis on the incidence of postoperative endophthalmitis after cataract surgery based on analysis of the findings of the European Society of Cataract & Refractive Surgeons (ESCRS) multicenter study. SETTING:Twenty-four ophthalmology units in ...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章,多中心研究,随机对照试验

    doi:10.1016/j.jcrs.2007.02.032

    authors: Endophthalmitis Study Group, European Society of Cataract & Refractive Surgeons.

    更新日期:2007-06-01 00:00:00

  • Effect of incision length, location, and shape on local corneoscleral deformation during cataract surgery.

    abstract::The effect of incision length, location, and shape on the structural integrity of the globe was examined using finite element analysis by comparing the radial deformation of the corneoscleral tissue adjacent to the incision. The results show that incision length had the greatest adverse effect, 12 mm incisions causing...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(13)80879-6

    authors: Armeniades CD,Boriek A,Knolle GE Jr

    更新日期:1990-01-01 00:00:00

  • Determinants of visual outcome after pars plana vitrectomy for posteriorly dislocated lens fragments in phacoemulsification.

    abstract:PURPOSE:To evaluate the visual outcome of patients with posteriorly dislocated lens fragments after phacoemulsification managed with pars plana vitrectomy (PPV) and identify risk factors for poor visual outcome. SETTING:Vitreo-Retinal Service, St. Paul Eye Unit, Liverpool, United Kingdom. METHODS:The medical records ...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(01)00750-7

    authors: Al-Khaier A,Wong D,Lois N,Cota N,Yang YC,Groenewald C

    更新日期:2001-08-01 00:00:00

  • Lateral tarsorrhaphy for prevention of postoperative complications resulting from globe luxation.

    abstract::We present a case of spontaneous globe luxation and wound dehiscence that developed in a patient with proptosis 1 day after phacoemulsification with posterior chamber intraocular lens implantation. The wound was repaired and a lateral tarsorrhaphy was performed with successful prevention of further luxations. Upon cat...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(03)00056-7

    authors: Johnson SM,Vestal RY

    更新日期:2003-09-01 00:00:00

  • Capsulorhexis contraction after cataract surgery: comparison of sharp anterior edge and modified anterior edge acrylic intraocular lenses.

    abstract:PURPOSE:To evaluate the reduction in the anterior capsule opening after phacoemulsification, continuous curvilinear capsulorhexis, and implantation of 1 of 2 acrylic intraocular lenses (IOLs). SETTING:Department of Ophthalmology, Vejle Hospital, Vejle, Denmark. METHODS:Eighty-four patients (84 eyes) were included in ...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章,随机对照试验

    doi:10.1016/j.jcrs.2007.01.020

    authors: Corydon C,Lindholt M,Knudsen EB,Graakjaer J,Corydon TJ,Dam-Johansen M

    更新日期:2007-05-01 00:00:00

  • The impact of glistenings on the optical quality of a hydrophobic acrylic intraocular lens.

    abstract:PURPOSE:To study the effect of glistenings on the optical quality of a hydrophobic acrylic intraocular lens (IOL). SETTING:David J. Apple Laboratory, Heidelberg, Germany. DESIGN:An in vitro laboratory study. METHODS:An accelerated aging protocol was used to induce glistenings (microvacuoles) in 38 hydrophobic acryli...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2019.01.025

    authors: Weindler JN,Łabuz G,Yildirim TM,Tandogan T,Khoramnia R,Auffarth GU

    更新日期:2019-07-01 00:00:00

  • Higher-order aberrations and visual function in pseudophakic eyes with a toric intraocular lens.

    abstract:PURPOSE:To compare higher-order aberrations (HOAs) and visual function in eyes with a toric intraocular lens (IOL) and eyes with a nontoric IOL. SETTING:Hayashi Eye Hospital, Fukuoka, Japan. DESIGN:Case-control study. METHODS:Eyes that had phacoemulsification were enrolled in 1 of the following 3 groups: (1) preoper...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2012.02.032

    authors: Hayashi K,Kondo H,Yoshida M,Manabe S,Hirata A

    更新日期:2012-07-01 00:00:00

  • Complement activation by surface modified poly(methyl methacrylate) intraocular lenses.

    abstract::The complement activation potential of surface modified (passivated) poly(methyl methacrylate) (PMMA) intraocular lenses (IOLs) with polypropylene loops was compared to that of standard PMMA IOLs with polypropylene loops. Both lens types were incubated in human sera for six hours and then the C3a and C5a levels were m...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(13)80243-x

    authors: Kochounian HH,Maxwell WA,Gupta A

    更新日期:1991-03-01 00:00:00

  • Comparative quantification of ingress of trypan blue into the anterior chamber after microcoaxial, standard coaxial, and bimanual phacoemulsification: randomized clinical trial.

    abstract:PURPOSE:To compare ocular surface fluid ingress into the anterior chamber at the end of microcoaxial, standard coaxial, and bimanual phacoemulsification using trypan blue as the quantifying tracer. SETTING:Iladevi Cataract and IOL Research Centre, Ahmedabad, India. METHODS:This prospective randomized observational st...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章,随机对照试验

    doi:10.1016/j.jcrs.2008.03.015

    authors: Praveen MR,Vasavada AR,Gajjar D,Pandita D,Vasavada VA,Vasavada VA,Raj SM

    更新日期:2008-06-01 00:00:00

  • Culture-negative ulcerative keratitis after laser in situ keratomileusis.

    abstract::A 40-year old man, highly myopic in both eyes, had laser in situ keratomileusis (LASIK) in the left eye in November 1996. Corneal melting and ulceration and fine striae-like interface infiltrates were noticed 1 day postoperatively. There was no response to intensive topical antibiotics in the form of hourly ofloxacin ...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(99)00080-2

    authors: Lam DS,Leung AT,Wu JT,Fan DS,Cheng AC,Wang Z

    更新日期:1999-07-01 00:00:00

  • Trypan blue capsule staining to visualize the capsulorhexis in cataract surgery.

    abstract::A capsulorhexis may be difficult to perform in the absence of a red fundus reflex. Using 0.1 mL of trypan blue 0.1% to stain the anterior capsule in 30 patients with a mature cataract enabled us to visualize the capsulorhexis during phacoemulsification. No adverse reactions were observed up to 12 months after surgery....

    journal_title:Journal of cataract and refractive surgery

    pub_type: 临床试验,杂志文章

    doi:10.1016/s0886-3350(99)80004-2

    authors: Melles GR,de Waard PW,Pameyer JH,Houdijn Beekhuis W

    更新日期:1999-01-01 00:00:00

  • Laser in situ keratomileusis for the correction of myopia and myopic astigmatism.

    abstract:PURPOSE:To evaluate the efficacy, safety, predictability, and surgically induced astigmatism (SIA) of laser in situ keratomileusis (LASIK) for the correction of myopia and myopic astigmatism. SETTING:Department of Ophthalmology, National Taiwan University Hospital, Taipei, Taiwan. METHODS:This retrospective study com...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(01)01071-9

    authors: Yang CN,Shen EP,Hu FR

    更新日期:2001-12-01 00:00:00

  • Outcomes of Descemet membrane endothelial keratoplasty in phakic eyes.

    abstract:PURPOSE:To determine the clinical outcomes of isolated Descemet membrane transplantation (ie, Descemet membrane endothelial keratoplasty [DMEK]) in phakic eyes. SETTING:Tertiary referral center. DESIGN:Cohort study. METHODS:Phakic eyes from a larger group of consecutive eyes that had DMEK for Fuchs endothelial dystr...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2011.11.038

    authors: Parker J,Dirisamer M,Naveiras M,Tse WH,van Dijk K,Frank LE,Ham L,Melles GR

    更新日期:2012-05-01 00:00:00

  • Intraocular lens power calculation with an improved anterior chamber depth prediction algorithm.

    abstract::The accuracy of intraocular lens (IOL) power calculation was evaluated in a multicenter study of 822 IOL implantations using the Binkhorst II, Sanders/Retzlaff/Kraff (SRK I, SRK II, SRK/T), Holladay, and Olsen formulas. All but the first of these were optimized in retrospect with calculation of the SRK A-constant, the...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章,多中心研究

    doi:10.1016/s0886-3350(13)80140-x

    authors: Olsen T,Corydon L,Gimbel H

    更新日期:1995-05-01 00:00:00

  • Clinical features of RBC-coated IOL after breakthrough vitreous hemorrhage secondary to neovascular age-related macular degeneration.

    abstract:PURPOSE:To investigate the incidence and clinical features of red blood cell (RBC)-coated intraocular lens (IOL) in breakthrough vitreous hemorrhage (VH) with subretinal hemorrhage (SRH) secondary to neovascular age-related macular degeneration (nAMD). SETTING:Seoul National University Bundang Hospital, Seongnam, Kore...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1097/j.jcrs.0000000000000549

    authors: Kim HM,Murakami Y,Woo SJ

    更新日期:2020-12-09 00:00:00

  • Clinical performance of a handheld digital infrared monocular pupillometer for measurement of the dark-adapted pupil diameter.

    abstract:PURPOSE:To compare the accuracy of a handheld infrared digital pupillometer and digital infrared photography for measurement of the dark-adapted pupil diameter. SETTING:Department of Ophthalmology and Visual Sciences, Texas Tech University Health Sciences Center, Lubbock, Texas, USA. METHODS:The right horizontal pupi...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2009.09.025

    authors: Bradley JC,Bentley KC,Mughal AI,Brown SM

    更新日期:2010-02-01 00:00:00

  • Safety and efficacy of incisional goniotomy as an adjunct with phacoemulsification in primary angle-closure glaucoma.

    abstract:PURPOSE:To evaluate the intraocular pressure (IOP)-lowering efficacy and safety of incisional goniotomy as an adjunct to phacoemulsification in primary angle-closure glaucoma (PACG) patients. METHODS:In this prospective interventional case series, consecutive patients with PACG (high or borderline IOP) deemed fit for ...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1097/j.jcrs.0000000000000481

    authors: Gupta S,Sethi A,Yadav S,Optom M,Azmira K,Singh A,Gupta V

    更新日期:2020-11-19 00:00:00

  • Comparison of 2 monocular pupillometers and an autorefractor for measurement of the dark-adapted pupil diameter.

    abstract:PURPOSE:To compare the performance of the Marco Nidek ARK-530A autorefractor pupillometer function and the Keeler PupilScan II pupillometer (study pupillometer) against the clinical standard NeurOptics PLR-200 pupillometer (standard pupillometer) for measurement of the dark-adapted pupil diameter. SETTING:Department o...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2010.10.059

    authors: Brown SM,Bradley JC

    更新日期:2011-04-01 00:00:00

  • Use of power modulations in phacoemulsification. Choo-choo chop and flip phacoemulsification.

    abstract::We used power modulations in addition to new technology available from 6 phacoemulsification manufacturers and altered our phacoemulsification techniques to take advantage of these technologies to significantly reduce the amount of ultrasound energy placed into the eye and enhance the rapidity and level of visual reha...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(00)00834-8

    authors: Fine IH,Packer M,Hoffman RS

    更新日期:2001-02-01 00:00:00

  • Laser in situ keratomileusis for -6.00 to -18.00 diopters of myopia and up to -5.00 diopters of astigmatism: 15-year follow-up.

    abstract:PURPOSE:To evaluate the long-term outcomes of laser in situ keratomileusis (LASIK) for high myopia with or without astigmatism. SETTING:Vissum Instituto Oftalmologico de Alicante and Miguel Hernandez University, Alicante, Spain. DESIGN:Retrospective-prospective case series. METHODS:Laser in situ keratomileusis was p...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2014.08.029

    authors: Alió JL,Soria F,Abbouda A,Peña-García P

    更新日期:2015-01-01 00:00:00

  • Endocapsular hyphema.

    abstract::A 67-year-old female developed an endocapsular hyphema after uncomplicated extracapsular cataract surgery. With a neodymium:YAG laser capsulotomy, we drained the blood into the vitreous and restored excellent visual acuity. We hypothesize that endocapsular hyphemas may fail to resorb because of sequestration of the cl...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(13)80316-1

    authors: Zagelbaum BM,Hersh PS

    更新日期:1993-05-01 00:00:00

  • Effect of incision size and site on corneal endothelial changes in cataract surgery.

    abstract:PURPOSE:To compare endothelial damage induced by different cataract incision sites and sizes using specular microscopy. SETTING:Department of Ophthalmology, Hospital of San Donà di Piave, Venice, Italy. METHODS:Eighty-one eyes having phacoemulsification were randomly assigned to 1 of 3 groups of 27 eyes each: 3.5 mm ...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1016/s0886-3350(01)00983-x

    authors: Beltrame G,Salvetat ML,Driussi G,Chizzolini M

    更新日期:2002-01-01 00:00:00

  • Anterior chamber depth measurements in phakic and pseudophakic eyes: Pentacam versus ultrasound device.

    abstract:PURPOSE:To compare anterior chamber depth (ACD) measurements with a new optical device with those taken with a standard ultrasound (US) device in emmetropic phakic and pseudophakic eyes. SETTING:Department of Ophthalmology, Medical Health and Science Center, University of Debrecen, Debrecen, Hungary. METHODS:Forty-tw...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2006.02.057

    authors: Nemeth G,Vajas A,Kolozsvari B,Berta A,Modis L Jr

    更新日期:2006-08-01 00:00:00

  • Clinical analysis of the factors contributing to pupillary optic capture after transscleral fixation of posterior chamber intraocular lens for dislocated intraocular lens.

    abstract:PURPOSE:To study the incidence of and risk factors for pupillary capture after transscleral fixation of a posterior chamber intraocular lens (PC IOL) for dislocated IOLs. SETTING:Department of Ophthalmology, Kyungpook National University Hospital, Daegu, South Korea. DESIGN:Retrospective case series. METHODS:Charts ...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2016.05.006

    authors: Kang DJ,Kim HK

    更新日期:2016-08-01 00:00:00