Gastric mucosal surface in cirrhosis evaluated by magnifying endoscopy and scanning electronic microscopy.

Abstract:

BACKGROUND AND STUDY AIMS:Gastric mucosa may have several tiny patterns in portal hypertension. In this prospective study, we used magnifying endoscopy and scanning electron microscopy (SEM) to better characterize the morphology of gastric mucosa in patients with cirrhosis, and we evaluated the diagnostic accuracy of magnifying endoscopy. PATIENTS AND METHODS:Videotapes of gastric mucosal patterns from 39 cirrhotic patients and 20 control patients were blindly evaluated by the same observer using magnifying endoscopy (magnification x 25) and conventional endoscopy. SEM was performed in 12 other patients. The basic anatomical entities of the gastric architecture on conventional endoscopy were the gastric area in control patients and the mosaic pattern in patients with cirrhosis. RESULTS:With regard to the prevalence of endoscopic patterns in the antrum, the mosaic pattern was more frequent in cirrhotic patients. In the body, the mosaic pattern, white spots, and red marks were significantly more frequent in cirrhotic patients, whereas gastric areas were more frequent in control patients. Concerning the contributions of the techniques, significantly more gastric areas were identified by magnifying endoscopy than by conventional endoscopy. However, in multivariate analysis, only conventional endoscopy with esophageal varices had significant independent diagnostic accuracy for cirrhosis, and magnifying endoscopy of mucosal signs did not add any significant information. SEM did not improve discrimination between control and cirrhotic patients. CONCLUSIONS:Magnifying endoscopy provides more details of the mucosa, thus improving the delineation of gastric mucosal morphology. However, magnifying endoscopy has little clinical value in cirrhosis since it does not improve on the accuracy of conventional endoscopy for the diagnosis of cirrhosis.

journal_name

Endoscopy

journal_title

Endoscopy

authors

Calès P,Oberti F,Delmotte JS,Baslé M,Casa C,Arnaud JP

doi

10.1055/s-2000-9019

subject

Has Abstract

pub_date

2000-08-01 00:00:00

pages

614-23

issue

8

eissn

0013-726X

issn

1438-8812

journal_volume

32

pub_type

杂志文章
  • Flexible sigmoidoscopy performed by nurses.

    abstract::Flexible sigmoidoscopy by nurses has rapidly become a widely accepted technique for distal colonic investigation. This review explores the issues of training and application of nurse performed flexible sigmoidoscopy, including the limitations, complications and cost issues. ...

    journal_title:Endoscopy

    pub_type: 杂志文章,评审

    doi:10.1055/s-2006-924986

    authors: Goodfellow PB

    更新日期:2006-06-01 00:00:00

  • Endoscopic ultrasonography: a promising method for assessing the prospects of endoscopic mucosal resection in early gastric cancer.

    abstract:BACKGROUND AND STUDY AIMS:A recent challenge that is increasingly being faced in endoscopy is the use of endoscopic mucosal resection (EMR) to treat differentiated intramucosal gastric cancers smaller than 2 cm. The usefulness of pretherapeutic endoscopic ultrasonography (EUS) in assessing whether this form of treatmen...

    journal_title:Endoscopy

    pub_type: 杂志文章

    doi:10.1055/s-2007-1004266

    authors: Akahoshi K,Chijiiwa Y,Hamada S,Sasaki I,Maruoka A,Kabemura T,Nawata H

    更新日期:1997-09-01 00:00:00

  • Do endoscopy capsules interfere with implantable cardioverter-defibrillators?

    abstract:BACKGROUND AND STUDY AIMS:Capsule endoscopy is already an established diagnostic tool, and the newly introduced capsule PillCam COLON is now entering clinical studies. Because of the very limited clinical experience in patients with implantable cardioverter-defibrillators (ICDs), it is generally recommended that capsul...

    journal_title:Endoscopy

    pub_type: 杂志文章

    doi:10.1055/s-0029-1214610

    authors: Bandorski D,Irnich W,Brück M,Kramer W,Jakobs R

    更新日期:2009-05-01 00:00:00

  • Chromoendoscopy using indigo carmine dye spraying with magnifying observation is the most reliable method for differential diagnosis between non-neoplastic and neoplastic colorectal lesions: a prospective study.

    abstract:BACKGROUND AND AIMS:Differential diagnosis between non-neoplastic and neoplastic lesions is very important at colonoscopy, since removal or biopsy of non-neoplastic polyps wastes time and resources. We therefore conducted a prospective study to examine whether indigo carmine dye spraying with and without magnification ...

    journal_title:Endoscopy

    pub_type: 临床试验,杂志文章

    doi:10.1055/s-2004-826039

    authors: Fu KI,Sano Y,Kato S,Fujii T,Nagashima F,Yoshino T,Okuno T,Yoshida S,Fujimori T

    更新日期:2004-12-01 00:00:00

  • Improved endoscopic stenting for malignant dysphagia using Tygon plastic prostheses.

    abstract:BACKGROUND AND STUDY AIMS:Endoscopic palliative treatment of malignant esophageal stenosis using conventional plastic stents has been reported to be associated with a considerable risk of perforation. Stenoses with a distance of less than 2cm from the upper esophageal sphincter (UES) have generally been excluded from t...

    journal_title:Endoscopy

    pub_type: 杂志文章

    doi:10.1055/s-2007-1001338

    authors: Bohnacker S,Thonke F,Hinner M,Seitz U,Binmoeller KF,Brand B,Rathod VD,Soehendra N

    更新日期:1998-08-01 00:00:00

  • Endoscopic injection therapy of Forrest II and III gastroduodenal ulcers guided by endoscopic Doppler ultrasound.

    abstract::Endoscopic Doppler ultrasound enables the reliable identification of vessels in the base of gastroduodenal ulcers. In a prospective study including 114 patients with acute ulcer bleeding, pulsed Doppler ultrasound was able to demonstrate superficial blood vessels in the ulcer base in 62% of 106 cases where complete Do...

    journal_title:Endoscopy

    pub_type: 杂志文章

    doi:10.1055/s-2007-1010296

    authors: Kohler B,Riemann JF

    更新日期:1993-03-01 00:00:00

  • The diagnostic value of transendoscopic miniature ultrasonic probe for esophageal diseases.

    abstract:BACKGROUND AND STUDY AIMS:To investigate the value of a transendoscopic miniature ultrasonic probe (USP) in the diagnosis of esophageal diseases. PATIENTS AND METHODS:Endoscopic ultrasonography was performed by means of USP in 53 patients with esophageal diseases, including 16 with esophageal leiomyoma, 14 with esopha...

    journal_title:Endoscopy

    pub_type: 杂志文章

    doi:

    authors: Xu GM,Niu YL,Zou XP,Jin ZD,Li ZS

    更新日期:1998-08-01 00:00:00

  • Endoscopic submucosal dissection in a European setting. A multi-institutional report of a technique in development.

    abstract:BACKGROUND AND STUDY AIMS:Endoscopic submucosal dissection (ESD) is a technique for "en bloc" resection of superficial tumors of the gastrointestinal tract. In France, experience with this technique is still limited. We wanted to assess the development of ESD in France, with special attention to short term outcomes. P...

    journal_title:Endoscopy

    pub_type: 杂志文章,多中心研究

    doi:10.1055/s-0030-1256413

    authors: Farhat S,Chaussade S,Ponchon T,Coumaros D,Charachon A,Barrioz T,Koch S,Houcke P,Cellier C,Heresbach D,Lepilliez V,Napoleon B,Bauret P,Coron E,Le Rhun M,Bichard P,Vaillant E,Calazel A,Bensoussan E,Bellon S,Mangiala

    更新日期:2011-08-01 00:00:00

  • DDW Report 2004 New Orleans: Capsule Endoscopy.

    abstract::Capsule endoscopy (CE) is still of considerable interest and, as in recent years, a large number of abstracts have been devoted to CE in various possible indications. As with the other reports, only the most relevant studies and those covering special and new aspects are discussed in detail here. The remaining abstrac...

    journal_title:Endoscopy

    pub_type: 杂志文章

    doi:10.1055/s-2004-825815

    authors: Rösch T

    更新日期:2004-09-01 00:00:00

  • Treatment algorithm for postoperative upper gastrointestinal fistulas and leaks using combined vicryl plug and fibrin glue.

    abstract::The incidence of clinically significant anastomotic leaks after upper gastrointestinal surgery is approximately 4 % - 20 %, and the associated mortality can be as high as 80 %. Depending on the clinical presentation, the treatment options are surgery, conservative treatment with external drainage, or endoscopic treatm...

    journal_title:Endoscopy

    pub_type: 杂志文章

    doi:10.1055/s-0029-1244165

    authors: Böhm G,Mossdorf A,Klink C,Klinge U,Jansen M,Schumpelick V,Truong S

    更新日期:2010-07-01 00:00:00

  • Endoscopic vs. laparoscopic gastrojejunostomy for duodenal obstruction: a randomized study in a porcine model.

    abstract:BACKGROUND AND STUDY AIMS:Open or laparoscopic gastrojejunostomy is an established treatment for malignant duodenal obstruction but may be associated with significant morbidity and mortality. The purpose of this study was to develop a model for an entirely endoscopic gastrojejunostomy to treat duodenal obstruction, and...

    journal_title:Endoscopy

    pub_type: 杂志文章

    doi:10.1055/s-0031-1291447

    authors: von Renteln D,Vassiliou MC,McKenna D,Suriawinata AA,Swain CP,Rothstein RI

    更新日期:2012-02-01 00:00:00

  • Confocal laser scanning fluorescence microscopy for in vivo determination of microvessel density in Barrett's esophagus.

    abstract:BACKGROUND AND STUDY AIMS:Angiogenesis has been reported to be an essential step in the progression of cancers arising from Barrett's esophagus. Confocal laser scanning microscopy (CLM) has the potential to perform in vivo microscopy to detect angiogenesis and determine microvessel density (MVD). We aimed therefore to ...

    journal_title:Endoscopy

    pub_type: 杂志文章

    doi:10.1055/s-2008-1077718

    authors: Becker V,Vieth M,Bajbouj M,Schmid RM,Meining A

    更新日期:2008-11-01 00:00:00

  • Exploring the clinical potential of an automatic colonic polyp detection method based on the creation of energy maps.

    abstract:BACKGROUND AND AIMS:Polyp miss-rate is a drawback of colonoscopy that increases significantly for small polyps. We explored the efficacy of an automatic computer-vision method for polyp detection. METHODS:Our method relies on a model that defines polyp boundaries as valleys of image intensity. Valley information is in...

    journal_title:Endoscopy

    pub_type: 杂志文章

    doi:10.1055/s-0042-108434

    authors: Fernández-Esparrach G,Bernal J,López-Cerón M,Córdova H,Sánchez-Montes C,Rodríguez de Miguel C,Sánchez FJ

    更新日期:2016-09-01 00:00:00

  • The diagnostic accuracy of high-resolution endoscopy, autofluorescence imaging and narrow-band imaging for differentially diagnosing colon adenoma.

    abstract:BACKGROUND AND STUDY AIMS:Conventional colonoscopy can result in unnecessary biopsy or endoscopic resection due to its inability to distinguish adenomas from hyperplastic polyps. This study therefore evaluated the efficacy of high-resolution endoscopy (HRE), autofluorescence imaging (AFI), and narrow-band imaging (NBI)...

    journal_title:Endoscopy

    pub_type: 杂志文章,多中心研究,随机对照试验

    doi:10.1055/s-0030-1256510

    authors: Sato R,Fujiya M,Watari J,Ueno N,Moriichi K,Kashima S,Maeda S,Ando K,Kawabata H,Sugiyama R,Nomura Y,Nata T,Itabashi K,Inaba Y,Okamoto K,Mizukami Y,Saitoh Y,Kohgo Y

    更新日期:2011-10-01 00:00:00

  • Endoscopic retrograde cholangiopancreatography after a liquid fatty meal: effect on deep common bile duct cannulation time.

    abstract:BACKGROUND AND STUDY AIM:Endoscopic retrograde cholangiopancreatography (ERCP) is an important gastrointestinal endoscopic procedure in the study and treatment of pancreaticobiliary diseases. The critical step of the procedure is cannulation of the common bile duct (CBD) and/or the pancreatic duct. Cannulation can be a...

    journal_title:Endoscopy

    pub_type: 杂志文章,随机对照试验

    doi:10.1055/s-2005-921116

    authors: Barrie M,Klein SD,Brown CA,Edge MD,Affronti JA,Cai Q

    更新日期:2006-03-01 00:00:00

  • Two liters of polyethylene glycol-electrolyte lavage solution versus sodium phosphate as bowel cleansing regimen for colonoscopy: a prospective randomized controlled trial.

    abstract:BACKGROUND AND STUDY AIMS:As a bowel cleansing agent for colonoscopy, sodium phosphate (NaP) has been reported to have equal effectiveness and better patient tolerance in comparison with 4 l polyethylene glycol-electrolyte lavage (PEG-EL) solution. Poor patient tolerance is frequently associated with a large amount of ...

    journal_title:Endoscopy

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1055/s-2002-33207

    authors: Poon CM,Lee DW,Mak SK,Ko CW,Chan KC,Chan KW,Sin KS,Chan AC

    更新日期:2002-07-01 00:00:00

  • Investigation of the sphincter of Oddi before, immediately after and six weeks after endoscopic papillotomy.

    abstract::The sphincter of Oddi was investigated before, immediately after and 6 weeks after endoscopic sphincterotomy by endoscopic inspection, ERCP manometry, and by X-ray following retrograde cholangiography in 14 patients presenting with bile duct stones. The sphincter motility was normal before sphincterotomy. Following el...

    journal_title:Endoscopy

    pub_type: 杂志文章

    doi:10.1055/s-2007-1018313

    authors: Staritz M,Ewe K,Meyer zum Büschenfelde KH

    更新日期:1986-01-01 00:00:00

  • Remote contrast injector in ERCP for protection from X-ray exposure.

    abstract::To protect the assistants from radiation during ERCP, a remote contrast injector employing a lever mechanism (push lever type) was developed. Using this remote injector, safe, finely controlled and easy injection of the contrast material was achieved without X-ray exposure to the assistants in ERCP. ...

    journal_title:Endoscopy

    pub_type: 杂志文章

    doi:10.1055/s-2007-1021616

    authors: Oi I

    更新日期:1982-09-01 00:00:00

  • A variant of an accessory common bile duct.

    abstract::While variations of the common bile duct are relatively common, true duplication of the common bile duct is very rare. Such deviation from normal anatomy, if unrecognized, may cause problems during surgical intervention. Here we present a case of a unique variant of an accessory bile duct which arises from the conflue...

    journal_title:Endoscopy

    pub_type: 杂志文章

    doi:10.1055/s-2000-7033

    authors: Leung B,Lai P,Chan A,Chan YL,Lau WY

    更新日期:2000-09-01 00:00:00

  • Small prophylactic pancreatic duct stents: an assessment of spontaneous passage and stent-induced ductal abnormalities.

    abstract:BACKGROUND AND STUDY AIMS:Placing small stents in the pancreatic duct at endoscopic retrograde cholangiopancreatography reduces the risk of pancreatitis. However, this practice means that a second procedure might be required to remove the stent, and stents can also damage the duct. The aims of this study were to determ...

    journal_title:Endoscopy

    pub_type: 杂志文章

    doi:10.1055/s-2007-966815

    authors: Lawrence C,Cotton PB,Romagnuolo J,Payne KM,Rawls E,Hawes RH

    更新日期:2007-12-01 00:00:00

  • A new system for rapid large-caliber percutaneous transhepatic drainage in patients with obstructive jaundice: a prospective randomized trial.

    abstract:UNLABELLED:BACKGROUND AND STUDY, AIMS: Percutaneous access to the biliary tract is an important diagnostic and therapeutic tool in the management of biliary diseases. It is usually chosen when the endoscopic approach via endoscopic retrograde cholangiopancreatography (ERCP) fails, or is not possible. Once established, ...

    journal_title:Endoscopy

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1055/s-2001-12814

    authors: Frimberger E,Vente T,Wagenpfeil S,Gerein P,Born P,Fritz N,Allescher HD,Ott R,Weigert N,Classen M,Rösch T

    更新日期:2001-03-01 00:00:00

  • Laparoscopy-assisted endoscopic full-thickness resection of gastric subepithelial tumors using a nonexposure technique.

    abstract::Background and study aims: To avoid bacterial contamination and tumor seeding during gastrectomy surgery, we developed a nonexposure technique for endoscopic full-thickness resection with laparoscopic assistance. The feasibility and safety of nonexposed endoscopic wall-inversion surgery (NEWS) for gastric subepithelia...

    journal_title:Endoscopy

    pub_type: 杂志文章

    doi:10.1055/s-0042-111000

    authors: Goto O,Takeuchi H,Sasaki M,Kawakubo H,Akimoto T,Fujimoto A,Ochiai Y,Maehata T,Nishizawa T,Kitagawa Y,Yahagi N

    更新日期:2016-11-01 00:00:00

  • A novel magnetic countertraction device for endoscopic submucosal dissection significantly reduces procedure time and minimizes technical difficulty.

    abstract:BACKGROUND AND STUDY AIMS:In endoscopic submucosal dissection (ESD), effective countertraction may overcome the current drawbacks of longer procedure times and increased technical demands. The objective of this study was to compare the efficacy of ESD using a novel magnetic countertraction device with that of the tradi...

    journal_title:Endoscopy

    pub_type: 杂志文章

    doi:10.1055/s-0034-1364940

    authors: Aihara H,Ryou M,Kumar N,Ryan MB,Thompson CC

    更新日期:2014-05-01 00:00:00

  • Prospective comparison between double-balloon enteroscopy and spiral enteroscopy.

    abstract:BACKGROUND AND STUDY AIMS:Push enteroscopy, balloon-guided, and single- and double-balloon enteroscopy (DBE) are now well established techniques in gastrointestinal endoscopy for small-bowel imaging and therapy. There are no published prospective studies comparing DBE with spiral enteroscopy and so the aim of the curre...

    journal_title:Endoscopy

    pub_type: 杂志文章

    doi:10.1055/s-0030-1255714

    authors: Frieling T,Heise J,Sassenrath W,Hülsdonk A,Kreysel C

    更新日期:2010-11-01 00:00:00

  • Partially covered self-expandable metallic stents for benign biliary strictures due to chronic pancreatitis.

    abstract:BACKGROUND AND STUDY AIMS:Benign biliary strictures (BBS) may occur in patients with chronic pancreatitis and may lead to secondary biliary cirrhosis or recurrent cholangitis. Although surgical diversion may provide definitive therapy, it can be associated with significant morbidity. Endoscopic therapy with plastic ste...

    journal_title:Endoscopy

    pub_type: 杂志文章

    doi:10.1055/s-0029-1214708

    authors: Behm B,Brock A,Clarke BW,Ellen K,Northup PG,Dumonceau JM,Kahaleh M

    更新日期:2009-06-01 00:00:00

  • Development, standardization, and evaluation of NOTES cholecystectomy using a transsigmoid approach in the porcine model: an acute feasibility study.

    abstract:BACKGROUND:Transluminal cholecystectomy is feasible. However, the procedure is time consuming, difficult, and poorly standardized so far. In the present study we therefore aimed to further evaluate and optimize a transsigmoid approach for cholecystectomy with minimal transabdominal assistance in the porcine model. MET...

    journal_title:Endoscopy

    pub_type: 杂志文章

    doi:10.1055/s-2007-966904

    authors: Meining A,Wilhelm D,Burian M,Dundoulakis M,Schneider A,von Delius S,Feussner H

    更新日期:2007-10-01 00:00:00

  • Evaluation of endoscopic-ultrasound-guided celiac ganglion irradiation with iodine-125 seeds: a pilot study in a porcine model.

    abstract:BACKGROUND AND STUDY AIMS:Implantation of iodine-125 ( (125)I) seeds under the guidance of endoscopic ultrasonography (EUS) has been proved to be a safe alternative treatment option for advanced pancreatic cancer. The main purpose of this study was to evaluate the feasibility and safety of EUS-guided radiation of the c...

    journal_title:Endoscopy

    pub_type: 杂志文章

    doi:10.1055/s-0028-1119588

    authors: Wang K,Jin Z,Du Y,Chen J,Zhan X,Wang L,Li Z,Zou D,Liu Y

    更新日期:2009-04-01 00:00:00

  • Bleeding after endoscopic sphincterotomy or papillary balloon dilation among users of antithrombotic agents.

    abstract:BACKGROUND AND STUDY AIMS:Severe bleeding is a potentially lethal complication after endoscopic sphincterotomy (EST) and endoscopic papillary balloon dilation (EPBD) for choledocholithiasis. This study aimed to evaluate the impact of antiplatelet agents and anticoagulants on this complication. PATIENTS AND METHODS:Pat...

    journal_title:Endoscopy

    pub_type: 杂志文章

    doi:10.1055/s-0034-1392408

    authors: Hamada T,Yasunaga H,Nakai Y,Isayama H,Matsui H,Horiguchi H,Fushimi K,Koike K

    更新日期:2015-11-01 00:00:00

  • Clinical features and time trends associated with an endoscopically normal esophagus in active eosinophilic esophagitis.

    abstract:BACKGROUND:A proportion of patients with active eosinophilic esophagitis (EoE) have a normal-appearing esophagus on esophagogastroduodenoscopy (EGD). We aimed to determine the associations between the baseline clinical features and the endoscopically normal esophagus in EoE, as well as time trends in reporting. METHOD...

    journal_title:Endoscopy

    pub_type: 杂志文章

    doi:10.1055/a-1284-5891

    authors: Eluri S,Corder SR,Kim E,Tappata M,Reed CC,Shaheen NJ,Dellon ES

    更新日期:2020-10-06 00:00:00

  • Single- vs. double-balloon enteroscopy in small-bowel diagnostics: a randomized multicenter trial.

    abstract:BACKGROUND AND STUDY AIMS:Double-balloon enteroscopy (DBE) is the first choice endoscopic technique for small-bowel visualization. However, preparation and handling of the double-balloon enteroscope is complex. Recently, a single-balloon enteroscopy (SBE) system has been introduced as being a simplified, less-complex b...

    journal_title:Endoscopy

    pub_type: 杂志文章,多中心研究,随机对照试验

    doi:10.1055/s-0030-1256247

    authors: Domagk D,Mensink P,Aktas H,Lenz P,Meister T,Luegering A,Ullerich H,Aabakken L,Heinecke A,Domschke W,Kuipers E,Bretthauer M

    更新日期:2011-06-01 00:00:00