Abstract:
:Implantable wireless neural recording from a large ensemble of simultaneously acting neurons is a critical component to thoroughly investigate neural interactions and brain dynamics from freely moving animals. Recent researches have shown the feasibility of simultaneously recording from hundreds of neurons and suggested that the ability of recording a larger number of neurons results in better signal quality. This massive recording inevitably demands a large amount of data transfer. For example, recording 2000 neurons while keeping the signal fidelity ( > 12 bit, > 40 KS/s per neuron) needs approximately a 1-Gb/s data link. Designing a wireless data telemetry system to support such (or higher) data rate while aiming to lower the power consumption of an implantable device imposes a grand challenge on neuroscience community. In this paper, we present a wireless gigabit data telemetry for future large-scale neural recording interface. This telemetry comprises of a pair of low-power gigabit transmitter and receiver operating at 60 GHz, and establishes a short-distance wireless link to transfer the massive amount of neural signals outward from the implanted device. The transmission distance of the received neural signal can be further extended by an externally rendezvous wireless transceiver, which is less power/heat-constraint since it is not at the immediate proximity of the cortex and its radiated signal is not seriously attenuated by the lossy tissue. The gigabit data link has been demonstrated to achieve a high data rate of 6 Gb/s with a bit-error-rate of 10(-12) at a transmission distance of 6 mm, an applicable separation between transmitter and receiver. This high data rate is able to support thousands of recording channels while ensuring a low energy cost per bit of 2.08 pJ/b.
journal_name
IEEE J Biomed Health Informjournal_title
IEEE journal of biomedical and health informaticsauthors
Kuan YC,Lo YK,Kim Y,Chang MC,Liu Wdoi
10.1109/JBHI.2015.2416202subject
Has Abstractpub_date
2015-05-01 00:00:00pages
949-57issue
3eissn
2168-2194issn
2168-2208journal_volume
19pub_type
杂志文章abstract::Fall detection is an important public healthcare problem. Timely detection could enable instant delivery of medical service to the injured. A popular nonintrusive solution for fall detection is based on videos obtained through ambient camera, and the corresponding methods usually require a large dataset to train a cla...
journal_title:IEEE journal of biomedical and health informatics
pub_type: 杂志文章
doi:10.1109/JBHI.2018.2808281
更新日期:2019-01-01 00:00:00
abstract::Diabetic retinopathy (DR) is a complication of diabetes that severely affects eyes. It can be graded into five levels of severity according to international protocol. However, optimizing a grading model to have strong generalizability requires a large amount of balanced training data, which is difficult to collect, pa...
journal_title:IEEE journal of biomedical and health informatics
pub_type: 杂志文章
doi:10.1109/JBHI.2020.3045475
更新日期:2020-12-17 00:00:00
abstract::The knee flexion-extension angle is an important variable to be monitored in various clinical scenarios, for example, during physical rehabilitation assessment. The purpose of this work is to develop and validate a sensor fusion system based on a knee sleeve for monitoring of physical therapy. The system consists of m...
journal_title:IEEE journal of biomedical and health informatics
pub_type: 杂志文章
doi:10.1109/JBHI.2020.2988360
更新日期:2020-04-20 00:00:00
abstract::The structure of the cumulative food intake (CFI) curve has been associated with obesity and eating disorders. Scales that record the weight loss of a plate from which a subject eats food are used for capturing this curve; however, their measurements are contaminated by additive noise and are distorted by certain type...
journal_title:IEEE journal of biomedical and health informatics
pub_type: 杂志文章
doi:10.1109/JBHI.2018.2812243
更新日期:2019-03-01 00:00:00
abstract::Effective vein visualization is clinically important for various point-of-care applications, such as needle insertion. It can be achieved by utilizing ultrasound imaging or by applying infrared laser excitation and monitoring its absorption. However, while these approaches can be used for vein visualization, they are ...
journal_title:IEEE journal of biomedical and health informatics
pub_type: 杂志文章
doi:10.1109/JBHI.2014.2313145
更新日期:2015-03-01 00:00:00
abstract::The fast evolving and deadly outbreak of coronavirus disease (COVID-19) has posed grand challenges to human society. To slow the spread of virus infections and better respond for community mitigation, by advancing capabilities of artificial intelligence (AI) and leveraging the large-scale and up-to-date data generated...
journal_title:IEEE journal of biomedical and health informatics
pub_type: 杂志文章
doi:10.1109/JBHI.2020.3009314
更新日期:2020-10-01 00:00:00
abstract::In the last decade, data mining techniques have been applied to sensor data in a wide range of application domains, such as healthcare monitoring systems, manufacturing processes, intrusion detection, database management, and others. Many data mining techniques are based on computing the similarity between two sensor ...
journal_title:IEEE journal of biomedical and health informatics
pub_type: 杂志文章
doi:10.1109/JBHI.2015.2424711
更新日期:2016-05-01 00:00:00
abstract::The quality of experience and quality of service provided in the healthcare sector are critical in evaluating the reliable delivery of the healthcare services provided. Medical images and videos play a major role in modern e-health services and have become an integral part of medical data communication systems. The qu...
journal_title:IEEE journal of biomedical and health informatics
pub_type: 杂志文章
doi:10.1109/JBHI.2014.2326891
更新日期:2014-09-01 00:00:00
abstract::In heart-beat-based security, a security key is derived from the time difference between consecutive heart beats (the inter-pulse interval, IPI), which may, subsequently, be used to enable secure communication. While heart-beat-based security holds promise in mobile health (mHealth) applications, there currently exist...
journal_title:IEEE journal of biomedical and health informatics
pub_type: 杂志文章
doi:10.1109/JBHI.2015.2496151
更新日期:2017-01-01 00:00:00
abstract::We present our efforts toward enabling a wearable sensor system that allows for the correlation of individual environmental exposures with physiologic and subsequent adverse health responses. This system will permit a better understanding of the impact of increased ozone levels and other pollutants on chronic asthma c...
journal_title:IEEE journal of biomedical and health informatics
pub_type: 杂志文章
doi:10.1109/JBHI.2016.2573286
更新日期:2016-09-01 00:00:00
abstract::The aim of this study was to evaluate the inertial measures of the 30-s chair stand test using modern body-fixed motion sensors. Polynomial data fitting was used to correct the drift effect in the position estimation. Thereafter, the three most important test cycles phases ("impulse," "stand up," and "sit down") were ...
journal_title:IEEE journal of biomedical and health informatics
pub_type: 杂志文章
doi:10.1109/JBHI.2013.2238243
更新日期:2013-07-01 00:00:00
abstract::This paper presents a novel three-stage blood vessel segmentation algorithm using fundus photographs. In the first stage, the green plane of a fundus image is preprocessed to extract a binary image after high-pass filtering, and another binary image from the morphologically reconstructed enhanced image for the vessel ...
journal_title:IEEE journal of biomedical and health informatics
pub_type: 杂志文章
doi:10.1109/JBHI.2014.2335617
更新日期:2015-05-01 00:00:00
abstract::This paper proposes a new blind end-member and abundance extraction (BEAE) method for multispectral fluorescence lifetime imaging microscopy (m-FLIM) data. The chemometrical analysis relies on an iterative estimation of the fluorescence decay end-members and their abundances. The proposed method is based on a linear m...
journal_title:IEEE journal of biomedical and health informatics
pub_type: 杂志文章
doi:10.1109/JBHI.2013.2279335
更新日期:2014-03-01 00:00:00
abstract::This paper presents a QuadTree-based melanoma detection system inspired by dermatologists' color perception. Clinical color assessment in dermoscopy images is challenging because of subtle differences in shades, location-dependent color information, poor color contrast, and wide variation among images of the same clas...
journal_title:IEEE journal of biomedical and health informatics
pub_type: 杂志文章
doi:10.1109/JBHI.2018.2841428
更新日期:2019-03-01 00:00:00
abstract::Dry eye syndrome is one of the most frequently reported eye diseases in ophthalmological practice. The diagnosis of this disease is a challenging task due to its multifactorial etiology. One of the most applied tests is the manual classification of tear film images captured with the Doane interferometer. The interfere...
journal_title:IEEE journal of biomedical and health informatics
pub_type: 杂志文章
doi:10.1109/JBHI.2020.3026940
更新日期:2020-12-01 00:00:00
abstract::Wireless medical sensor networks (MSNs) are a key enabling technology in e-healthcare that allows the data of a patient's vital body parameters to be collected by the wearable or implantable biosensors. However, the security and privacy protection of the collected data is a major unsolved issue, with challenges coming...
journal_title:IEEE journal of biomedical and health informatics
pub_type: 杂志文章
doi:10.1109/JBHI.2013.2268897
更新日期:2014-01-01 00:00:00
abstract::In this paper, we propose an automated method to reconstruct the three-dimensional (3-D) needle shape during needle insertion procedures using only 2-D transverse ultrasound (US) images. Using a set of transverse US images, image processing and random sample consensus are used to locate the needle within each image an...
journal_title:IEEE journal of biomedical and health informatics
pub_type: 杂志文章
doi:10.1109/JBHI.2015.2477829
更新日期:2016-11-01 00:00:00
abstract::This paper presents an innovative wearable kinesthetic glove realized with knitted piezoresistive fabric (KPF) sensor technology. The glove is conceived to capture hand movement and gesture by using KPF in a double-layer configuration working as angular sensors (electrogoniometers). The sensing glove prototype is endo...
journal_title:IEEE journal of biomedical and health informatics
pub_type: 杂志文章
doi:10.1109/JBHI.2014.2324293
更新日期:2014-11-01 00:00:00
abstract::Sensor systems can be deployed in the homes of older adults living alone for functional health assessments. Their information is very useful for health care specialists. The problem lies in developing person independent models while facing a large variability in behavior. We address this problem by, first, proposing a...
journal_title:IEEE journal of biomedical and health informatics
pub_type: 杂志文章
doi:10.1109/JBHI.2016.2593980
更新日期:2017-07-01 00:00:00
abstract:PURPOSE:Women with BRCA1/2 mutations have higher risk for breast and ovarian cancers. Available intervention actions include prophylactic surgeries and breast screening, which vary significantly in cost, cancer prevention, and in resulting death from other causes. We present a model designed to yield optimal interventi...
journal_title:IEEE journal of biomedical and health informatics
pub_type: 杂志文章
doi:10.1109/JBHI.2014.2319246
更新日期:2015-03-01 00:00:00
abstract::This paper proposes an anaesthesia monitoring system that accurately measures the depth of anaesthesia through 40-Hz auditory steady-state response. With accurate and fast depth of anaesthesia measuring, the monitor can reduce the incidence of awareness during surgical operation. The proposed denoising method for extr...
journal_title:IEEE journal of biomedical and health informatics
pub_type: 杂志文章
doi:10.1109/JBHI.2017.2778140
更新日期:2018-11-01 00:00:00
abstract::The development of the narrow-band imaging (NBI) has been increasing the interest of medical specialists in the study of laryngeal microvascular network to establish diagnosis without biopsy and pathological examination. A possible solution to this challenging problem is presented in this paper, which proposes an auto...
journal_title:IEEE journal of biomedical and health informatics
pub_type: 杂志文章
doi:10.1109/JBHI.2014.2374975
更新日期:2016-01-01 00:00:00
abstract::The continuing interest in unobtrusive electrocardiography requires the development of algorithms, compensating for an increased number of artifacts. In previous work, we proposed a framework for robust parameter estimation of signals following a piecewise Gaussian derivative model, well suited for describing all wave...
journal_title:IEEE journal of biomedical and health informatics
pub_type: 杂志文章
doi:10.1109/JBHI.2019.2963786
更新日期:2020-08-01 00:00:00
abstract::The study of cell morphology is an important aspect of the diagnosis of some diseases, such as sickle cell disease, because red blood cell deformation is caused by these diseases. Due to the elongated shape of the erythrocyte, ellipse adjustment and concave point detection are applied widely to images of peripheral bl...
journal_title:IEEE journal of biomedical and health informatics
pub_type: 杂志文章
doi:10.1109/JBHI.2014.2356402
更新日期:2015-07-01 00:00:00
abstract::Precise skin lesion classification is still challenging due to two problems, i.e., (1) inter-class similarity and intra-class variation of skin lesion images, and (2) the weak generalization ability of single Deep Convolutional Neural Network trained with limited data. Therefore, we propose a Global-Part Convolutional...
journal_title:IEEE journal of biomedical and health informatics
pub_type: 杂志文章
doi:10.1109/JBHI.2020.2977013
更新日期:2020-10-01 00:00:00
abstract::Opioid misuse and overdose have become a public health hazard and caused drug addiction and death in the United States due to rapid increase in prescribed and non-prescribed opioid usage. The misuse and overdose are highly related to opioid over-prescription for chronic and acute pain treatment, where a one-size-fits-...
journal_title:IEEE journal of biomedical and health informatics
pub_type: 杂志文章
doi:10.1109/JBHI.2020.2992973
更新日期:2021-01-01 00:00:00
abstract::Exergaming is expanding as an option for sedentary behavior in childhood/adult obesity and for extra exercise for gamers. This paper presents the development process for a mobile active sports exergame with near-realistic motions through the usage of body-wearable sensors. The process begins by collecting a dataset sp...
journal_title:IEEE journal of biomedical and health informatics
pub_type: 杂志文章
doi:10.1109/JBHI.2013.2293674
更新日期:2014-03-01 00:00:00
abstract::With the passage of recent federal legislation, many medical institutions are now responsible for reaching target hospital readmission rates. Chronic diseases account for many hospital readmissions and chronic obstructive pulmonary disease has been recently added to the list of diseases for which the United States gov...
journal_title:IEEE journal of biomedical and health informatics
pub_type: 杂志文章
doi:10.1109/JBHI.2017.2684121
更新日期:2018-03-01 00:00:00
abstract::Adverse drug-drug interaction (ADDI) becomes a significant threat to public health. Despite the detection of ADDIs is experimentally implemented in the early development phase of drug design, many potential ADDIs are still clinically explored by accidents, leading to a large number of morbidity and mortality. Several ...
journal_title:IEEE journal of biomedical and health informatics
pub_type: 杂志文章
doi:10.1109/JBHI.2020.3048059
更新日期:2020-12-29 00:00:00
abstract::Artificial intelligence and decision support systems offer a plethora of health monitoring capabilities in ambient assisted living environment. Continuous assessment of health indicators for elderly people living on their own is of utmost importance, so as to prolong their independence and quality of life. Slow varyin...
journal_title:IEEE journal of biomedical and health informatics
pub_type: 杂志文章
doi:10.1109/JBHI.2014.2336757
更新日期:2015-01-01 00:00:00