Abstract:
BACKGROUND:The human respiratory airway undergoes dramatic growth during infancy and childhood, which induces substantial variability in air flow pattern and particle deposition. However, deposition studies have typically focused on adult subjects, the results of which cannot be readily extrapolated to children. We developed models to quantify the growth of human nasal-laryngeal airways at early ages, and to evaluate the impact of that growth on breathing resistance and aerosol deposition. METHODS:Four image-based nasal-laryngeal models were developed from 4 children, ages 10 days, 7 months, 3 years, and 5 years, and were compared to a nasal-laryngeal model of a 53-year-old adult. The airway dimensions were quantified in terms of different parameters (volume, cross-section area, and hydraulic diameter) and of different anatomies (nose, pharynx, and larynx). Breathing resistance and aerosol deposition were computed using a high-fidelity fluid-particle transport model, and were validated against the measurements made with the 3-dimensional models fabricated from the same airway computed tomography images. RESULTS:Significant differences in nasal morphology were observed among the 5 subjects, in both morphology and dimension. The turbinate region appeared to experience the most noticeable growth during the first 5 years of life. The nasal airway volume ratios of the 10-day, 7-month, 3-year, and 5-year-old subjects were 6.4%, 18.8%, 24.2%, and 40.3% that of the adult, respectively. Remarkable inter-group variability was observed in air flow, pressure drop, deposition fraction, and particle accumulation. The computational fluid dynamics predicted pressure drops and deposition fractions were in close agreement with in vitro measurements. CONCLUSIONS:Age effects are significant in both breathing resistance and micrometer particle deposition. The image/computational-fluid-dynamics coupled method provides an efficient and effective approach in understanding patient-specific air flows and particle deposition, which have important implications in pediatric inhalation drug delivery and respiratory disorder diagnosis.
journal_name
Respir Carejournal_title
Respiratory careauthors
Xi J,Si X,Zhou Y,Kim J,Berlinski Adoi
10.4187/respcare.02568subject
Has Abstractpub_date
2014-02-01 00:00:00pages
263-73issue
2eissn
0020-1324issn
1943-3654pii
respcare.02568journal_volume
59pub_type
杂志文章相关文献
Respiratory Care文献大全abstract:BACKGROUND:During high-flow oxygen therapy, heated humidified gas is delivered at high flow. Although the warmth and humidity of this gas facilitates mucociliary function in the lower airway, warm and humid conditions also promote bacterial growth. Bacterial contamination of high-flow oxygen therapy circuits has not be...
journal_title:Respiratory care
pub_type: 杂志文章
doi:10.4187/respcare.06299
更新日期:2019-05-01 00:00:00
abstract::Chronic obstructive pulmonary disease is easily detected in its preclinical phase, using office spirometry. Successful smoking cessation prevents further disease progression in most patients. Spirometry measures the ratio of the forced expiratory volume in the first second to the forced vital capacity (FEV(1)/FVC), wh...
journal_title:Respiratory care
pub_type: 杂志文章,评审
doi:
更新日期:2003-12-01 00:00:00
abstract:BACKGROUND:Obstructive lung disease is diagnosed by a decreased ratio of FEV1 to the vital capacity (VC). Although the most commonly used VC is FVC, American Thoracic Society guidelines suggest alternative VCs, for example, slow VC (SVC), may offer a more-accurate evaluation of breathing capacity. There is recent evide...
journal_title:Respiratory care
pub_type: 杂志文章
doi:10.4187/respcare.06419
更新日期:2019-07-01 00:00:00
abstract:UNLABELLED:Lectures and demonstrations have been the teaching and testing strategies most often employed by the American Heart Association in Advanced Cardiac Life Support (ACLS) training. I compared the abilities of interactive videodisc (IVD) courseware and ACLS instructors to evaluate airway management skills. METH...
journal_title:Respiratory care
pub_type: 杂志文章
doi:
更新日期:1991-08-01 00:00:00
abstract:BACKGROUND:In this study, we aimed to validate the agreement between pulmonary function measurements obtained with a portable spirometer and measurements obtained with conventional spirometry in Chinese pediatric and adult populations. METHODS:Pulmonary function testing was performed to evaluate subjects enrolled at S...
journal_title:Respiratory care
pub_type: 杂志文章
doi:10.4187/respcare.07116
更新日期:2020-05-01 00:00:00
abstract:BACKGROUND:High-flow nasal cannula (HFNC) is commonly being used to provide noninvasive respiratory support in newborn infants. Continuous distending pressure generated by these devices in preterm infants has not been elucidated. The aim of this work was to determine the association between HFNC flow in L/min and end-e...
journal_title:Respiratory care
pub_type: 杂志文章
doi:10.4187/respcare.04317
更新日期:2016-03-01 00:00:00
abstract::The problem of patients in isolation becoming disconnected from their ventilator systems is a serious one, as the closed doors of an isolation room usually prevent hospital personnel outside the room from hearing or seeing standard ventilator alarms To overcome this potentially life-threatening problem, we modified a ...
journal_title:Respiratory care
pub_type: 杂志文章
doi:
更新日期:1986-05-01 00:00:00
abstract:BACKGROUND:For early detection of respiratory and hemodynamic changes during anesthesia, continuous end-tidal carbon dioxide concentration (PETCO2) is monitored by capnometry. However, the accuracy of CO2 monitoring during spontaneous breathing in extubated patients remains undetermined. Therefore, we aimed to compare ...
journal_title:Respiratory care
pub_type: 杂志文章
doi:10.4187/respcare.03557
更新日期:2015-05-01 00:00:00
abstract::Numerous ventilation modes and ventilation options have become available as new mechanical ventilators have reached the market. Ventilator manufacturers have no standardized terminology for ventilator modes and ventilation options, and ventilator operator's manuals do not help the clinician compare the modes of ventil...
journal_title:Respiratory care
pub_type: 杂志文章,评审
doi:
更新日期:2001-06-01 00:00:00
abstract:BACKGROUND:The reduction of instrumental dead space is a recognized approach to preventing ventilation-induced lung injury in premature infants. However, there are no published data regarding the effectiveness of instrumental dead-space reduction in endotracheal tube (ETT) connectors. We tested the impact of the Y-piec...
journal_title:Respiratory care
pub_type: 杂志文章
doi:10.4187/respcare.04076
更新日期:2016-02-01 00:00:00
abstract:BACKGROUND:The frequency of combined obstruction and restriction identified in pulmonary function tests has not been well described. Moreover, although the causes of combined-obstruction-and-restriction patterns are known, the frequency of the various etiologies has received little attention. METHODS:We retrospectivel...
journal_title:Respiratory care
pub_type: 杂志文章
doi:
更新日期:2010-03-01 00:00:00
abstract::Sleep-disordered breathing (mainly obstructive sleep apnea [OSA]) and COPD are among the most common pulmonary diseases, so a great number of patients have both disorders; this "overlap syndrome" causes more severe nocturnal hypoxemia than either disease alone. This common combination of OSA and COPD has important imp...
journal_title:Respiratory care
pub_type: 杂志文章,评审
doi:
更新日期:2010-10-01 00:00:00
abstract::Inhaled aerosol drugs commonly used by patients with chronic obstructive pulmonary disease include short-acting and long-acting bronchodilators, as well as corticosteroids. These agents are available in a variety of inhaler devices, which include metered-dose inhalers (MDI), breath-actuated MDIs, nebulizers, and, curr...
journal_title:Respiratory care
pub_type: 杂志文章,评审
doi:
更新日期:2006-02-01 00:00:00
abstract:BACKGROUND:Inhaled sedation is efficient and easily controllable; in low concentrations it causes minimal changes in the patient and very little interference with hemodynamics. Awakening after inhaled sedation is quick and predictable. The major reason inhaled sedation has not become widely used in intensive care is th...
journal_title:Respiratory care
pub_type: 杂志文章
doi:
更新日期:2008-10-01 00:00:00
abstract::Aerosolized medications have been used for centuries to treat respiratory diseases. Until recently, inhalation therapy focused primarily on the treatment of asthma and chronic obstructive pulmonary disease, and the pressurized metered-dose inhaler was the delivery device of choice. However, the role of aerosol therapy...
journal_title:Respiratory care
pub_type: 杂志文章,评审
doi:
更新日期:2005-09-01 00:00:00
abstract::Ventilator circuits should not be changed routinely for infection control purposes. The maximum duration of time that circuits can be used safely is unknown. Evidence is lacking related to ventilator-associated pneumonia (VAP) and issues of heated versus unheated circuits, type of heated humidifier, method for filling...
journal_title:Respiratory care
pub_type: 指南,杂志文章,实务指引
doi:
更新日期:2003-09-01 00:00:00
abstract:BACKGROUND:Patterns of pulmonary function tests (PFTs) and flow-volume loops among patients with clinically important tracheobronchomalacia (TBM) are not well described. Small studies suggest 4 main flow-volume loop morphologies: low maximum forced expiratory flow, biphasic expiratory curve, flow oscillations, and notc...
journal_title:Respiratory care
pub_type: 杂志文章
doi:10.4187/respcare.02277
更新日期:2013-09-01 00:00:00
abstract::Extracorporeal life support (ECLS), or extracorporeal membrane oxygenation (ECMO) as it is also known, has been used to support over 45,000 patients to date. Overall survival is 62%. After many years of no change in equipment and technology, there has been a recent flurry of new pumps, cannulas, and oxygenators avail...
journal_title:Respiratory care
pub_type: 杂志文章,评审
doi:10.4187/respcare.01369
更新日期:2011-09-01 00:00:00
abstract::A computerized clinical information system (CIS) is potentially a very important information tool for research and improving health care processes as well as for optimizing data management and thereby minimizing health care costs. The newest CISs automatically collect patient data from various sources, including monit...
journal_title:Respiratory care
pub_type: 杂志文章
doi:
更新日期:2004-05-01 00:00:00
abstract:BACKGROUND:Patient work of breathing (WOB) during assisted ventilation is reduced when inspiratory flow (V(I)) from the ventilator exceeds patient flow demand. Patients in acute respiratory failure often have unstable breathing patterns and their requirements for V(I) may change from breath to breath. Volume control ve...
journal_title:Respiratory care
pub_type: 临床试验,杂志文章
doi:
更新日期:2000-09-01 00:00:00
abstract::Assisted (interactive) breathing is generally preferred to controlled breaths in patients on mechanical ventilators. Assisted breaths allow the patient's respiratory muscles to be used, and ventilatory muscle atrophy can be prevented. Moreover, the respiratory drive of the patient does not have to be aggressively blun...
journal_title:Respiratory care
pub_type: 杂志文章
doi:10.4187/respcare.00953
更新日期:2011-01-01 00:00:00
abstract::Increases in the utilization of respiratory therapy and the need to avoid its misuse have placed increasing management responsibilities on medical and technical supervisors of respiratory care services. To improve our managerial capabilities we designed a computerized respiratory care record system. Respiratory therap...
journal_title:Respiratory care
pub_type: 杂志文章
doi:
更新日期:1983-03-01 00:00:00
abstract::In blood gas laboratory quality-assurance programs, which are routinely included with materials sold for quality control, raw data are sent to a data processing center for reduction to statistics meaningful to the laboratory's quality-control effort. This data reduction service usually requires a turn-around time of 2...
journal_title:Respiratory care
pub_type: 杂志文章
doi:
更新日期:1984-04-01 00:00:00
abstract::Tracheostomy is one of the most commonly performed procedures in the ICU. Despite the frequency of the procedure, there remains controversy regarding selection of patients who should undergo tracheostomy, the optimal technique, timing of placement and decannulation, as well as impact on outcome associated with the pr...
journal_title:Respiratory care
pub_type: 杂志文章,评审
doi:10.4187/respcare.01914
更新日期:2012-10-01 00:00:00
abstract:BACKGROUND:The contribution of the central respiratory drive in the hypercapnic respiratory failure of neuromuscular diseases (NMD) is controversial. OBJECTIVE:To compare the CO2 response and the duration of weaning of mechanical ventilation between a group of NMD patients and a group of quadriplegic patients due to I...
journal_title:Respiratory care
pub_type: 杂志文章,多中心研究
doi:10.4187/respcare.01873
更新日期:2013-03-01 00:00:00
abstract::In light of today's tight hospital financial picture caused by Medicare's prospective payment system and local constraints, capital expenditures must be made with great care and forethought. The process for purchase decision making should assess the need for the device; specifically identify what is required; carefull...
journal_title:Respiratory care
pub_type: 杂志文章
doi:
更新日期:1985-08-01 00:00:00
abstract:BACKGROUND:Most heat-and-moisture exchangers (HMEs) for patients with tracheostomy and spontaneously breathing are small and have suction ports that allow some expiratory gas to escape, which loses water vapor held in the expired gas. Recently, a heated-and-humidified high-flow system for spontaneously breathing patien...
journal_title:Respiratory care
pub_type: 杂志文章
doi:10.4187/respcare.06294
更新日期:2019-02-01 00:00:00
abstract::Extracorporeal membrane oxygenation (ECMO) is a form of cardiopulmonary bypass adapted for long-term use. Blood is drained from the patient, pumped through an artificial lung or membrane where gas exchange is augmented, and then re-infused back to the patient. ECMO provides support for the neonate with severe respirat...
journal_title:Respiratory care
pub_type: 杂志文章
doi:
更新日期:2009-09-01 00:00:00
abstract:BACKGROUND:Portable oxygen devices simplify and facilitate patient therapy. This study was designed to compare S(pO2) and patient satisfaction with a portable oxygen concentrator or a combined system consisting of a fixed device with continuous-flow oxygen dispensation and a portable device with pulse dispensation for ...
journal_title:Respiratory care
pub_type: 杂志文章,多中心研究,随机对照试验
doi:10.4187/respcare.03470
更新日期:2015-03-01 00:00:00
abstract::Although oral and injectable drug formulations still dominate the market, interest in pulmonary delivery has been rising steadily. Given patients' desire for an alternative to injections, and recent advances in aerosol science and pulmonary medicine, the potential for improved disease management outcomes by using aero...
journal_title:Respiratory care
pub_type: 杂志文章,评审
doi:
更新日期:2000-07-01 00:00:00