Detecting ICRS grade 1 cartilage lesions in anterior cruciate ligament injury using T1ρ and T2 mapping.

Abstract:

OBJECTIVE:The purpose of this study was to clarify the detectability of the International Cartilage Repair Society (ICRS) grade 1 cartilage lesions in anterior cruciate ligament (ACL)-injured knees using T1ρ and T2 mapping. MATERIALS AND METHODS:We performed preoperative T1ρ and T2 mapping and 3D gradient-echo with water-selective excitation (WATS) sequences on 37 subjects with ACL injuries. We determined the detectability on 3D WATS based on arthroscopic findings. The T1ρ and T2 values (ms) were measured in the regions of interest that were placed on the weight-bearing cartilage of the femoral condyle. The receiver operating characteristic (ROC) curve based on these values was constructed using the arthroscopic findings as a reference standard. The evaluation of cartilage was carried out only in the weight-bearing cartilage. The cut-off values for determining the presence of a cartilage injury were determined using each ROC curve, and the detectability was calculated for the T1ρ and T2 mapping. RESULTS:The cut-off values for the T1ρ and T2 were 41.6 and 41.2, respectively. The sensitivity and specificity of T1ρ were 91.2% and 89.5%, respectively, while those of T2 were 76.5% and 81.6%, respectively. For the 3D WATS images, the same values were 58.8% and 78.9%, respectively. CONCLUSIONS:Our study demonstrated that the T1ρ and T2 values were significantly higher for ICRS grade 1 cartilage lesions than for normal cartilage and that the two mappings were able to non-invasively detect ICRS grade 1 cartilage lesions in the ACL-injured knee with a higher detectability than were 3D WATS images.

journal_name

Eur J Radiol

authors

Nishioka H,Hirose J,Nakamura E,Okamoto N,Karasugi T,Taniwaki T,Okada T,Yamashita Y,Mizuta H

doi

10.1016/j.ejrad.2013.04.038

subject

Has Abstract

pub_date

2013-09-01 00:00:00

pages

1499-505

issue

9

eissn

0720-048X

issn

1872-7727

pii

S0720-048X(13)00235-0

journal_volume

82

pub_type

杂志文章
  • MR imaging of acute pancreatitis: correlation of abdominal wall edema with severity scores.

    abstract:OBJECTIVE:To study MRI findings of abdominal wall edema (AWE) in acute pancreatitis as well as correlations between AWE and the severity of acute pancreatitis according to the MR severity index (MRSI) and the Acute Physiology And Chronic Healthy Evaluation III (APACHE III) scoring system. MATERIALS AND METHODS:A total...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2012.04.005

    authors: Yang R,Jing ZL,Zhang XM,Tang W,Xiao B,Huang XH,Yang L,Feng ZS

    更新日期:2012-11-01 00:00:00

  • Effect of digital edge-enhancement on the visibility of normal parenchymal lung markings.

    abstract::Digital 'conventional-like' (C-L) and edge-enhanced (E-E) posteroanterior chest roentgenograms of 42 healthy individuals were ranked twice (interval of at least 5 days) in the order of increasing lung parenchymal markings (a total of four rankings). This was done by three radiologists, two residents, one medical stude...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/0720-048x(94)90275-5

    authors: Vehmas T,Korhola O,Pölönen P,Knuutila T,Kivisaari A,Holmberg J,Bondestam S,Tikkanen H

    更新日期:1994-05-01 00:00:00

  • Thermography in suspected deep venous thrombosis of lower leg.

    abstract::Phlebography has proved to be the most reliable method to diagnose a deep venous thrombosis of a lower leg. In this study it is attempted to evaluate the accuracy of thermography in diagnosing a deep venous thrombosis. The series comprises 125 patients which were investigated with thermography and phlebography. A diag...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:

    authors: Soini IH

    更新日期:1985-11-01 00:00:00

  • Dense bone around the sacroiliac joint: a radiological review of the differential diagnosis.

    abstract::Solitary osteosclerotic bone lesions around the sacroiliac (SI) joints are described as seen on plain radiographs or conventional tomography, with the descriptive attributes ranging from round to ovoid over square and triangular to multiform. The etiology of the solitary osteosclerotic lesions around the SI joint can ...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/s0720-048x(97)00175-7

    authors: Dihlmann W,Hering L

    更新日期:1998-07-01 00:00:00

  • MRI quantifies lumbosacral nerve root and sciatic nerve hypertrophy in chronic inflammatory demyelinating polyradiculoneuropathy.

    abstract:PURPOSE:Chronic inflammatory demyelinating polyradiculoneuropathy (CIDP) is a treatable, immune-mediated condition characterised by progressive or relapsing motor and sensory neurological deficits. The diagnosis is based on a combination of clinical, neurophysiological and supportive criteria, but can be challenging. I...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2020.109164

    authors: Shah S,Morrow JM,Sinclair CDJ,Reilly MM,Thornton JS,Lunn MP,Yousry TA

    更新日期:2020-09-01 00:00:00

  • Imaging-therapy computed tomography with quasi-monochromatic X-rays.

    abstract:INTRODUCTION:Computed tomography (CT) is a widespread and highly precise technique working in the energy range around 50-100 keV. For radiotherapy, however, the MeV energy range enables a better dose distribution. This gap between diagnosis and therapy can be overcome by the use of a modified CT machine in combination ...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2008.04.040

    authors: Jost G,Golfier S,Lawaczeck R,Weinmann HJ,Gerlach M,Cibik L,Krumrey M,Fratzscher D,Rabe J,Arkadiev V,Haschke M,Langhoff N,Wedell R,Luedemann L,Wust P,Pietsch H

    更新日期:2008-12-01 00:00:00

  • Worsening respiratory function in mechanically ventilated intensive care patients: feasibility and value of xenon-enhanced dual energy CT.

    abstract:OBJECTIVES:To evaluate the feasibility and incremental diagnostic value of xenon-enhanced dual-energy CT in mechanically ventilated intensive care patients with worsening respiratory function. METHODS:The study was performed in 13 mechanically ventilated patients with severe pulmonary conditions (acute respiratory dis...

    journal_title:European journal of radiology

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.ejrad.2012.10.029

    authors: Hoegl S,Meinel FG,Thieme SF,Johnson TR,Eickelberg O,Zwissler B,Nikolaou K

    更新日期:2013-03-01 00:00:00

  • Optimization of window settings for virtual monoenergetic imaging in dual-energy CT of the liver: A multi-reader evaluation of standard monoenergetic and advanced imaged-based monoenergetic datasets.

    abstract:OBJECTIVES:To evaluate optimal window settings for display of virtual monoenergetic reconstructions in third-generation dual-source, dual-energy computed tomography (DECT) of the liver. METHODS:Twenty-nine subjects were prospectively evaluated with DECT in arterial (AP) and portal venous (PVP) phases. Three reconstruc...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2016.01.007

    authors: De Cecco CN,Caruso D,Schoepf UJ,Wichmann JL,Ter Louw JR,Perry JD,Picard MM,Schaefer AR,Parker LW,Hardie AD

    更新日期:2016-04-01 00:00:00

  • Comparison between ultrasonography and MR imaging for discriminating squamous cell carcinoma nodes with extranodal spread in the neck.

    abstract:OBJECTIVE:To compare the diagnostic ability of ultrasonography (US) and MR imaging for discriminating squamous cell carcinoma (SCC) nodes with extranodal spread (ENS) in the neck. METHODS:US and MR imaging was retrospectively evaluated for differentiating ENS-positive (n=28) from ENS-negative (n=26) SCC nodes (>10mm s...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2012.06.018

    authors: Katayama I,Sasaki M,Kimura Y,Hotokezaka Y,Eida S,Tashiro S,Sumi M,Nakamura T

    更新日期:2012-11-01 00:00:00

  • Age-related changes of the diffusion tensor imaging parameters of the normal cervical spinal cord.

    abstract:BACKGROUND:The diffusion tensor imaging (DTI) parameters of the cervical spinal cord (CSC) changes with age. However, previous studies only examined specific CSC areas. OBJECTIVES:To analyze the DTI parameters in all intervertebral space levels of the whole normal CSC and to study the impact of age on these parameters...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2014.09.010

    authors: Wang K,Song Q,Zhang F,Chen Z,Hou C,Tang Y,Chen S,Hao Q,Shen H

    更新日期:2014-12-01 00:00:00

  • Modified RECIST to assess tumor response after transarterial chemoembolization of hepatocellular carcinoma: CT-pathologic correlation in 178 liver explants.

    abstract:PURPOSE:To retrospectively evaluate agreement between modified RECIST (mRECIST) assessed at Computed Tomography (CT) and pathology in a large series of patients with hepatocellular carcinoma (HCC) who were transplanted after transarterial chemoembolization (TACE). MATERIALS AND METHODS:IRB approval was obtained. The s...

    journal_title:European journal of radiology

    pub_type: 杂志文章,随机对照试验

    doi:10.1016/j.ejrad.2012.12.009

    authors: Bargellini I,Bozzi E,Campani D,Carrai P,De Simone P,Pollina L,Cioni R,Filipponi F,Bartolozzi C

    更新日期:2013-05-01 00:00:00

  • Image quality of early postoperative CT angiography with reduced contrast material and radiation dose using model-based iterative reconstruction for screening of renal pseudoaneurysms after partial nephrectomy.

    abstract:PURPOSE:To evaluate the image quality of early postoperative CT angiography with low contrast material and radiation dose using model-based iterative reconstruction (FIRST) for screening pseudoaneurysms after partial nephrectomy. METHODS:CT angiography was obtained before surgery using conventional iterative dose redu...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2020.108853

    authors: Morita S,Ogawa Y,Yamamoto T,Kamoshida K,Yamazaki H,Suzuki K,Sakai S,Kunihara M,Takagi T,Tanabe K

    更新日期:2020-03-01 00:00:00

  • MRI evaluation of patellar tendon defect after harvesting its central third.

    abstract:PURPOSE:the purpose of this study was to evaluate defect width of patellar tendon after harvest for anterior cruciate ligament reconstruction. MATERIALS AND METHODS:we performed MRI at various time interval after graft harvest (2-96 months) on 28 patients who had had reconstruction of the anterior cruciate ligament us...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2003.08.006

    authors: Koseoglu K,Memis A,Argin M,Arkun R

    更新日期:2004-06-01 00:00:00

  • Humeral hydatid cyst complicated with extraosseous involvement: a case of unusual location of echinococcosis.

    abstract::Hydatid disease is a parasitic disease most commonly caused by Echinococcus granulosus that seldom involves the skeleton and is still common in the countries of the temperate zones. We present an extremely rare case report of a young patient with humeral hydatid disease complicated with extraosseous involvement. Plain...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/s0720-048x(00)00219-9

    authors: Markonis A,Tavernaraki A,Papaevangelou M

    更新日期:2001-02-01 00:00:00

  • T1 mapping for detection of left ventricular myocardial fibrosis in hypertrophic cardiomyopathy: a preliminary study.

    abstract:PURPOSE:To investigate the diagnostic value of T1 mapping imaging of evaluating fibrosis in patients with hypertrophic cardiomyopathy (HCM). MATERIALS AND METHODS:21 subjects with HCM and 18 healthy volunteers underwent conventional late gadolinium enhancement (LGE) imaging and T1 mapping imaging. The region of myocar...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2012.12.014

    authors: Lu M,Zhao S,Yin G,Jiang S,Zhao T,Chen X,Tian L,Zhang Y,Wei Y,Liu Q,He Z,Xue H,An J,Shah S

    更新日期:2013-05-01 00:00:00

  • The use of coronary stent in hepatic artery stenosis after orthotopic liver transplantation.

    abstract:PURPOSE:This retrospective study was undertaken to evaluate the effectiveness of coronary stent placement in hepatic artery stenosis after orthotopic liver transplantation (OLT). MATERIALS AND METHODS:Of 430 consecutive adult orthotopic liver transplant recipients between November 2003 and September 2005, 17 had hepat...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2006.06.008

    authors: Huang M,Shan H,Jiang Z,Li Z,Zhu K,Guan S,Qian J,Chen G,Lu M,Yang Y

    更新日期:2006-12-01 00:00:00

  • Clinical evaluation of a computer simulated prediction model of contrast enhancement of the liver in spiral CT.

    abstract:OBJECTIVE:A software program was developed simulating a compartmental model of blood circulation based on differential equations. The aim of this study was to compare software-simulated levels of hepatic enhancement with the true values in patients and to test how many patients reach the simulated hepatic enhancement l...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/S0720-048X(03)00217-1

    authors: Schöber W,Kopp A,Scherf C,Mehnert F,Heuschmid M,Duda SH,Claussen CD,Pereira P

    更新日期:2004-07-01 00:00:00

  • Are Modic changes related to outcomes in lumbar disc herniation patients treated with imaging-guided lumbar nerve root blocks?

    abstract:OBJECTIVE:To compare outcomes after imaging-guided transforaminal lumbar nerve root blocks in MRI confirmed symptomatic disc herniation patients with and without Modic changes (MC). METHODS:Consecutive adult patients with MRI confirmed symptomatic lumbar disc herniations and an imaging-guided lumbar nerve root block i...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2014.06.008

    authors: Peterson CK,Pfirrmann CW,Hodler J

    更新日期:2014-10-01 00:00:00

  • Non-mass-like enhancement on contrast-enhanced breast MR imaging: lesion characterization using combination of dynamic contrast-enhanced and diffusion-weighted MR images.

    abstract:PURPOSE:To evaluate the diagnostic accuracy of a combination of dynamic contrast-enhanced MR imaging (DCE-MRI) and diffusion-weighted MR imaging (DWI) in characterization of lesions showing non-mass-like enhancement on breast MR imaging and to find the strongest discriminators between carcinoma and benignancy. MATERIA...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2009.09.013

    authors: Yabuuchi H,Matsuo Y,Kamitani T,Setoguchi T,Okafuji T,Soeda H,Sakai S,Hatakenaka M,Kubo M,Tokunaga E,Yamamoto H,Honda H

    更新日期:2010-07-01 00:00:00

  • Evaluation of the most optimal multiparametric magnetic resonance imaging sequence for determining pathological length of capsular contact.

    abstract:OBJECTIVES:To assess the most optimal multi-parametric magnetic resonance imaging sequence (Mp-MRI) in determining pathological length of capsular contact (LCC) for the diagnosis of prostate cancer extraprostatic extension (EPE). METHODS:105 patients with prostate cancer who underwent Mp-MRI of prostate prior to radic...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2019.01.020

    authors: Onay A,Vural M,Armutlu A,Ozel Yıldız S,Kiremit MC,Esen T,Bakır B

    更新日期:2019-03-01 00:00:00

  • Clinical validation of a pressure-standardized compression mammography system.

    abstract:OBJECTIVES:Validation of a pressure-standardized compression mammography (PSCM) system, which aims to reduce discomfort and pain by applying the same pressure to every breast, independent of breast size. METHODS:We retrospectively studied mammograms of 39 patients acquired with a conventional force-standardized compre...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2018.06.021

    authors: den Boer D,Dam-Vervloet LAJ,Boomsma MF,de Boer E,van Dalen JA,Poot L

    更新日期:2018-08-01 00:00:00

  • Ultrafine needle CO2 splenoportography: a comparative investigation with transarterial portography and MR portography.

    abstract:PURPOSE:To evaluate the safety and quality of CO2 splenoportography (CO2-SP) by comparison to 3-dimensional dynamic contrast-enhanced magnetic resonance portography (3D-DCE-MRP) and transarterial portography (TAP). MATERIALS AND METHODS:CO2-SP, 3D-DCE-MRP and TAP were performed within 3 days in 35 patients. CO2-SP was...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2006.03.006

    authors: Teng GJ,Deng G,Liu ZS,Fang W,Zhu GY,Li GZ,Guo JH,He SC,Dong YH

    更新日期:2006-09-01 00:00:00

  • Depiction of normal gastrointestinal anatomy with MDCT: comparison of low- and high-attenuation oral contrast media.

    abstract:PURPOSE:To compare low- and high-attenuation oral contrast media for depiction of normal gastrointestinal anatomy with multidetector-row computed tomography (MDCT). MATERIALS AND METHODS:A prospective, randomized study of 90 consecutive patients without known or suspected gastrointestinal disease was conducted after t...

    journal_title:European journal of radiology

    pub_type: 杂志文章,随机对照试验

    doi:10.1016/j.ejrad.2007.05.015

    authors: Erturk SM,Mortelé KJ,Oliva MR,Ichikawa T,Silverman SG,Cantisani V,Pagliara E,Ros PR

    更新日期:2008-04-01 00:00:00

  • MR appearance of normal and abnormal bile: correlation with imaging and endoscopic finding.

    abstract::Identification of abnormal bile related to various pathological processes in the pancreaticobiliary tract can be important in the diagnosis of disease and the determination of appropriate treatment. Magnetic resonance (MR) imaging can allow comprehensive evaluation of abnormal bile because MR usually provides better t...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2009.05.050

    authors: Lee NK,Kim S,Lee JW,Lee SH,Kang DH,Kim DU,Kim GH,Seo HI

    更新日期:2010-11-01 00:00:00

  • Coronary calcium scoring with MDCT: the radiation dose to the breast and the effectiveness of bismuth breast shield.

    abstract:OBJECTIVE:The purpose of our study was to determine the breast radiation dose during coronary calcium scoring with multidetector computerized tomography (MDCT). We also evaluated the degree of dose reduction by using a bismuth breast shield when performing coronary calcium scoring with MDCT. MATERIALS AND METHODS:The ...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2006.08.012

    authors: Yilmaz MH,Yaşar D,Albayram S,Adaletli I,Ozer H,Ozbayrak M,Mihmanli I,Akman C

    更新日期:2007-01-01 00:00:00

  • Assessment of glioma response to radiotherapy using 3D pulsed-continuous arterial spin labeling and 3D segmented volume.

    abstract:BACKGROUND:Gliomas are the most common primary brain tumors in adults, in some cases, radiotherapy may be the preferred treatment option especially for elderly people who cannot endure surgery. Therefore, it is necessary to evaluate the effects of radiotherapy on glioma. Arterial spin labeling (ASL) is an MR imaging te...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2016.08.009

    authors: Wang P,Li J,Diao Q,Lin Y,Zhang J,Li L,Yang G,Fang X,Li X,Chen Y,Zheng L,Lu G

    更新日期:2016-11-01 00:00:00

  • US and MR imaging of the postoperative knee.

    abstract::Constantly increasing number of surgical procedures on the soft tissues of and around the knee generates the need for postoperative soft tissue assessment. Sports medicine is constantly seeking new--faster, better, more efficient--ways to help patients, especially competitive athletes to come back to their full activi...

    journal_title:European journal of radiology

    pub_type: 杂志文章,评审

    doi:10.1016/j.ejrad.2007.01.018

    authors: Czyrny Z

    更新日期:2007-04-01 00:00:00

  • Higher precontrast CT density of the carotid plaque in the symptomatic patients.

    abstract:PURPOSE:The purpose of this study was to determine if there is a significant difference in the CT Hounsfield Unit (CTHU) of the carotid atherosclerotic plaque (CAP) on CTpre and CTartery depending on the presence of symptomatology. METHODS:Quantitative analysis of the CTHUs for the CAP was performed in 43 arteries (11...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2011.06.029

    authors: Park JK,Sung YH,Jeong SY,Lee JH

    更新日期:2012-09-01 00:00:00

  • Comparing the clinical utility of single-shot echo-planar imaging and readout-segmented echo-planar imaging in diffusion-weighted imaging of the liver at 3 tesla.

    abstract:PURPOSE:To compare the clinical utility of single-shot echo-planar imaging (SS-EPI) using different breathing schemes and readout-segmented EPI (RS-EPI) in the repeatability of apparent diffusion coefficient (ADC) measurements, signal-to-noise ratio (SNR) and image quality. METHODS:In this institutional review board-a...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2020.109472

    authors: Xie S,Masokano IB,Liu W,Long X,Li G,Pei Y,Li W

    更新日期:2021-02-01 00:00:00

  • Evaluation of traumatic spinal canal stenosis in thoracolumbar burst fractures. A comparison of three methods for measuring the percent canal occlusion.

    abstract:OBJECTIVES:Various percent canal occlusion measurement methods have been used to assess the spinal canal stenosis following a thoracolumbar burst fracture. However, there are no studies performed comparing these techniques. The objective of this study was to determine the reliability of three techniques used to measure...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2007.08.020

    authors: Dai LY,Wang XY,Jiang LS

    更新日期:2008-09-01 00:00:00