The type of surgical approach influences the risk of revision in total hip arthroplasty: a study from the Swedish Hip Arthroplasty Register of 90,662 total hipreplacements with 3 different cemented prostheses.

Abstract:

BACKGROUND AND PURPOSE:The most common surgical approaches in total hip arthroplasty in Sweden are the posterior and the anterolateral transgluteal approach. Currently, however, there is insufficient evidence to prefer one over the other regarding risk of subsequent surgery. PATIENTS AND METHODS:We searched the Swedish Hip Arthroplasty Register between the years 1992 and 2009 to compare the posterior and anterolateral transgluteal approach regarding risk of revision in the 3 most common all-cemented hip prosthesis designs in Sweden. 90,662 total hip replacements met the inclusion criteria. We used Cox regression analysis for estimation of prosthesis survival and relative risk of revision due to dislocation, infection, or aseptic loosening. RESULTS:Our results show that for the Lubinus SPII prosthesis and the Spectron EF Primary prosthesis, the anterolateral transgluteal approach gave an increased risk of revision due to aseptic loosening (relative risk (RR) = 1.3, 95% CI: 1.0-1.6 and RR = 1.6, CI: 1.0-2.5) but a reduced risk of revision due to dislocation (RR = 0.7, CI: 0.5-0.8 and RR = 0.3, CI: 0.1-0.4). For the Exeter Polished prosthesis, the surgical approach did not affect the outcome for dislocation or aseptic loosening. The surgical approach had no influence on the risk of revision due to infection in any of these designs. INTERPRETATION:This observational study shows that the surgical approach affected the risk of revision due to aseptic loosening and dislocation for 2 of the most commonly used cemented implants in Sweden. Further studies are needed to determine whether these results are generalizable to other implants and to uncemented fixation.

journal_name

Acta Orthop

journal_title

Acta orthopaedica

authors

Lindgren V,Garellick G,Kärrholm J,Wretenberg P

doi

10.3109/17453674.2012.742394

subject

Has Abstract

pub_date

2012-12-01 00:00:00

pages

559-65

issue

6

eissn

1745-3674

issn

1745-3682

journal_volume

83

pub_type

杂志文章
  • Estimation of the optimum loading of an antibiotic powder in an acrylic bone cement: gentamicin sulfate in SmartSet HV.

    abstract:BACKGROUND:In some countries, commercially available antibiotic powder-loaded acrylic bone cement is routinely used in joint replacement, while, in others, "off-label" formulations are used in selected procedures (where the antibiotic powder is blended manually with the powder of a plain cement in the operating room/th...

    journal_title:Acta orthopaedica

    pub_type: 杂志文章

    doi:10.1080/17453670610012700

    authors: Lewis G,Janna S

    更新日期:2006-08-01 00:00:00

  • Revision in previously satisfied knee arthroplasty patients is the result of their call on the physician, not on pre-planned follow-up: a retrospective study of 181 patients who underwent revision within 2 years.

    abstract:BACKGROUND:Degree of satisfaction with a knee arthroplasty is said to be correlated to reduced pain and better function. During a validation of the Swedish Knee Arthroplasty Register in 1997, previously operated patients were asked how satisfied they were with their knee. A subgroup of "satisfied" patients was identifi...

    journal_title:Acta orthopaedica

    pub_type: 杂志文章

    doi:10.1080/17453670510045372

    authors: Bremander AB,Dunbar M,Knutson K,Petersson IF,Robertsson O

    更新日期:2005-12-01 00:00:00

  • Preoperative psychosocial risk factors for poor outcomes at 1 and 5 years after total knee replacement.

    abstract::Background and purpose - Psychosocial factors are important risk factors for poor outcomes in the first year after total knee replacement (TKR), however their impact on long-term outcomes is unclear. We aimed to identify preoperative psychosocial risk factors for poor outcomes at 1 year and 5 years after TKR. Patients...

    journal_title:Acta orthopaedica

    pub_type: 杂志文章

    doi:10.1080/17453674.2017.1334180

    authors: Wylde V,Trela-Larsen L,Whitehouse MR,Blom AW

    更新日期:2017-10-01 00:00:00

  • Cemented total hip replacement in patients under 55 years.

    abstract::Background and purpose - About 86,000 total hip replacements (THR) have been registered in patients under 55 years in the National Joint Registry of England and Wales (NJR). The use of uncemented implants has increased, despite their outcomes not having been proven to be significantly better than cemented implants in ...

    journal_title:Acta orthopaedica

    pub_type: 杂志文章

    doi:10.1080/17453674.2018.1427320

    authors: Kiran M,Johnston LR,Sripada S,Mcleod GG,Jariwala AC

    更新日期:2018-04-01 00:00:00

  • Registration rate in the Norwegian Cruciate Ligament Register: large-volume hospitals perform better.

    abstract:BACKGROUND AND PURPOSE:The Norwegian Cruciate Ligament Register (NCLR) was founded in 2004. The purpose of the NCLR is to provide representative and reliable data for future research. In this study we evaluated the development of the registration rate in the NCLR. METHODS:The Norwegian Patient Register (NPR) and the e...

    journal_title:Acta orthopaedica

    pub_type: 杂志文章

    doi:10.3109/17453674.2012.678800

    authors: Ytterstad K,Granan LP,Ytterstad B,Steindal K,Fjeldsgaard KA,Furnes O,Engebretsen L

    更新日期:2012-04-01 00:00:00

  • The effect of hospital volume on length of stay, re-admissions, and complications of total hip arthroplasty.

    abstract:BACKGROUND AND PURPOSE:Hospital volume has been suggested to be one of the best indicators of adverse orthopedic events in patients undergoing THR surgery. We therefore evaluated the effect of hospital volume on the length of stay, re-admissions, and complications of THR at the population level in Finland. METHODS:30,...

    journal_title:Acta orthopaedica

    pub_type: 杂志文章

    doi:10.3109/17453674.2010.533930

    authors: Mäkelä KT,Häkkinen U,Peltola M,Linna M,Kröger H,Remes V

    更新日期:2011-02-01 00:00:00

  • In vitro comparison of frictional torque and torsional resistance of aged conventional gamma-in-nitrogen sterilized polyethylene versus aged highly crosslinked polyethylene articulating against head sizes larger than 32 mm.

    abstract:BACKGROUND:The advent of highly crosslinked polyethylene has allowed the re-evaluation of the use of femoral heads larger than 32 mm for metal-on-polyethylene total hip arthroplasties. However, the effect of larger heads on the frictional torque of highly crosslinked polyethylene is unknown. METHODS:We performed an in...

    journal_title:Acta orthopaedica

    pub_type: 杂志文章

    doi:10.1080/17453670610012881

    authors: Burroughs BR,Muratoglu OK,Bragdon CR,Wannomae KK,Christensen S,Lozynsky AJ,Harris WH

    更新日期:2006-10-01 00:00:00

  • Patient-reported history of leg ulceration 12-16 years after total primary knee or hip replacement.

    abstract:BACKGROUND AND PURPOSE:Deep vein thrombosis is common after total joint replacement. It is frequently asymptomatic, and it is unclear whether this leads to longer-term problems such as post-thrombotic syndrome and leg ulceration. We investigated whether the postoperative prevalence of ulceration in patients who had und...

    journal_title:Acta orthopaedica

    pub_type: 杂志文章

    doi:10.3109/17453674.2011.596064

    authors: Gould VC,Wylde V,Smith AJ,Blom AW

    更新日期:2011-08-01 00:00:00

  • Coronal alignment of the lower limb.

    abstract:BACKGROUND:The coronal alignment of the lower limb is important for knee reconstruction procedures. However, normal alignment is hard to define because of its wide variation among normal individuals. Our hypothesis was that the variation in the normal anatomy as assessed by radiography is greater than commonly accepted...

    journal_title:Acta orthopaedica

    pub_type: 杂志文章

    doi:

    authors: Jenny JY,Boeri C,Ballonzoli L

    更新日期:2005-06-01 00:00:00

  • HipSim - hip fracture surgery simulation utilizing the Learning Curve-Cumulative Summation test (LC-CUSUM).

    abstract::Background and purpose - Virtual reality simulation of hip fracture surgery is available for orthopedic residents nationwide in Denmark. Summative assessment of learning applying the learning curve cumulative summation test (LC-CUSUM) has not been utilized in orthopedic simulation training. The strength of the LC-CUSU...

    journal_title:Acta orthopaedica

    pub_type: 杂志文章

    doi:10.1080/17453674.2020.1777511

    authors: Rölfing JD,Jensen RD,Paltved C

    更新日期:2020-12-01 00:00:00

  • Increased mortality after anterior shoulder dislocation: 255 patients aged 12-40 years followed for 25 years.

    abstract:BACKGROUND:No data exist regarding mortality rate in young patients with a first-time anterior shoulder dislocation. A cohort of 255 patients aged 12-40 years had a primary anterior shoulder dislocation during the years 1978 and 1979. After 10 years, 9 of the patients had died--which is a high figure for this cohort of...

    journal_title:Acta orthopaedica

    pub_type: 杂志文章

    doi:10.1080/17453670710014617

    authors: Hovelius L,Nilsson JA,Nordqvist A

    更新日期:2007-12-01 00:00:00

  • The effect of smoking on outcomes following primary total hip and knee arthroplasty: a population-based cohort study of 117,024 patients.

    abstract::Background and purpose - Smoking is a modifiable risk factor that may adversely affect postoperative outcomes. Healthcare providers are increasingly denying smokers access to total hip and knee arthroplasty (THA and TKA) until they stop smoking. Evidence supporting this is unclear. We assessed the effect of smoking on...

    journal_title:Acta orthopaedica

    pub_type: 杂志文章

    doi:10.1080/17453674.2019.1649510

    authors: Matharu GS,Mouchti S,Twigg S,Delmestri A,Murray DW,Judge A,Pandit HG

    更新日期:2019-12-01 00:00:00

  • Different osteosyntheses for Colles' fracture: a mechanical study in 42 cadaver bones.

    abstract:BACKGROUND AND PURPOSE:In recent years several different plate designs for internal fixation of fractures of the distal radius have been developed. However, few biomechanical studies have been performed to compare these new implants. The purpose of this study was to compare the mechanical properties of 5 different comm...

    journal_title:Acta orthopaedica

    pub_type: 杂志文章

    doi:10.3109/17453670902947440

    authors: Krukhaug Y,Gjerdet NR,Lundberg OJ,Lilleng PK,Hove LM

    更新日期:2009-04-01 00:00:00

  • Transient expression of myofibroblast-like cells in rat rib fracture callus.

    abstract:BACKGROUND AND PURPOSE:We have previously shown that early fracture callus of rat rib has viscoelastic and contractile properties resembling those of smooth muscle. The cells responsible for this contractility have been hypothesized to be myofibroblast-like in nature. In soft-tissue healing, force generated by contract...

    journal_title:Acta orthopaedica

    pub_type: 杂志文章

    doi:10.3109/17453674.2011.652891

    authors: McDonald SJ,Dooley PC,McDonald AC,Schuijers JA,Ward AR,Grills BL

    更新日期:2012-02-01 00:00:00

  • Poor results from the isoelastic total hip replacement: 14-17-year follow-up of 149 cementless prostheses.

    abstract:BACKGROUND:To overcome the mismatch between a stiff stem and the more elastic bone, the concept of isoelasticity was introduced in the 1970s. This concept was based on the assumption that the implant and the bone should deform as one unit to avoid stress shielding. The Robert Mathys (RM) cementless total hip replacemen...

    journal_title:Acta orthopaedica

    pub_type: 杂志文章

    doi:10.1080/00016470510030535

    authors: Trebse R,Milosev I,Kovac S,Mikek M,Pisot V

    更新日期:2005-04-01 00:00:00

  • How do EQ-5D-3L and EQ-5D-5L compare in a Swedish total hip replacement population?

    abstract::Background and purpose - To better detect small changes in postoperative outcome following total hip replacement (THR), the Swedish Hip Arthroplasty Register (SHAR) has decided to change from the EQ-5D-3L (3L) to the EQ-5D-5L (5L). To enable comparison of results obtained with use of the 2 versions of EQ-5D, transfera...

    journal_title:Acta orthopaedica

    pub_type: 杂志文章

    doi:10.1080/17453674.2020.1746124

    authors: Eneqvist T,Nemes S,Kärrholm J,Burström K,Rolfson O

    更新日期:2020-06-01 00:00:00

  • The Bankart repair versus the Putti-Platt procedure: a randomized study with WOSI score at 10-year follow-up in 62 patients.

    abstract:BACKGROUND AND PURPOSE:This randomized study compared clinical results after surgery for posttraumatic shoulder instability with either an anatomical repair or an older, less anatomical but commonly used method. The less anatomical procedure has been considered quicker and less demanding, but it has been questioned reg...

    journal_title:Acta orthopaedica

    pub_type: 杂志文章,随机对照试验

    doi:10.3109/17453670902988345

    authors: Salomonsson B,Abbaszadegan H,Revay S,Lillkrona U

    更新日期:2009-06-01 00:00:00

  • Lipid oxidation may reduce the quality of a fresh-frozen bone allograft. Is the approved storage temperature too high?

    abstract:BACKGROUND:International standards indicate that bone allografts for human use should be stored in a -40 degrees C or colder environment and the storage time should be up to 5 years. Bone allografts contain lipids which oxidate and become toxic with time. MATERIAL AND METHODS:We determined lipid oxidation in femoral h...

    journal_title:Acta orthopaedica

    pub_type: 杂志文章

    doi:10.1080/17453670610046343

    authors: Laitinen M,Kivikari R,Hirn M

    更新日期:2006-06-01 00:00:00

  • Treatment of 2- and 3-part fractures of the proximal humerus using external fixation: a retrospective evaluation of 62 patients.

    abstract:BACKGROUND:Treatment of fractures of the humeral head remains controversial. We reviewed the outcome of our treatment of 2- and 3-part fractures of the proximal humerus using external fixation as a way of preventing damage to the vascularity of the humeral head and of reducing the risk of infection associated with open...

    journal_title:Acta orthopaedica

    pub_type: 杂志文章

    doi:10.1080/17453670610046028

    authors: Martin C,Guillen M,Lopez G

    更新日期:2006-04-01 00:00:00

  • Knee extensor muscle weakness and radiographic knee osteoarthritis progression.

    abstract::Background and purpose - Knee extensor (KE) muscle weakness is a modifiable feature commonly observed in individuals with knee osteoarthritis (KOA) and constitutes a potential target for patient-specific interventions. Therefore, in this study, we explored whether KE weakness is associated with radiographic (medial an...

    journal_title:Acta orthopaedica

    pub_type: 杂志文章

    doi:10.1080/17453674.2018.1464314

    authors: Dell'isola A,Wirth W,Steultjens M,Eckstein F,Culvenor AG

    更新日期:2018-08-01 00:00:00

  • Gas chromatography-mass spectroscopy analysis of emissions from cement when using ultrasonically driven tools.

    abstract:BACKGROUND:Ultrasonically driven tools have been used to reduce the incidence of complications during cement removal at revision hip replacement operations. These have been shown to be safe and effective in various ways, but produce fumes. METHODS:Using gas chromatography-mass spectroscopy, we analyzed the fumes produ...

    journal_title:Acta orthopaedica

    pub_type: 杂志文章

    doi:10.1080/17453670510041718

    authors: Shewale SB,Briggs RD

    更新日期:2005-10-01 00:00:00

  • Survivorship and relative risk of revision in computer-navigated versus conventional total knee replacement at 8-year follow-up.

    abstract::Background and purpose - The long-term effects of computer-assisted surgery in total knee replacement (CAS) compared to conventionally operated knee replacement (CON) are still not clear. We compared survivorship and relative risk of revision in CAS and CON based on data from the Norwegian Arthroplasty Register. Patie...

    journal_title:Acta orthopaedica

    pub_type: 杂志文章,多中心研究

    doi:10.1080/17453674.2016.1244884

    authors: Dyrhovden GS,Fenstad AM,Furnes O,Gøthesen Ø

    更新日期:2016-12-01 00:00:00

  • Migration and clinical outcome of mobile-bearing versus fixed-bearing single-radius total knee arthroplasty.

    abstract::Background and purpose - Mobile-bearing total knee prostheses (TKPs) were developed in the 1970s in an attempt to increase function and improve implant longevity. However, modern fixed-bearing designs like the single-radius TKP may provide similar advantages. We compared tibial component migration measured with radios...

    journal_title:Acta orthopaedica

    pub_type: 杂志文章,随机对照试验

    doi:10.1080/17453674.2018.1429108

    authors: Van Hamersveld KT,Marang-Van De Mheen PJ,Van Der Heide HJL,Van Der Linden-Van Der Zwaag HMJ,Valstar ER,Nelissen RGHH

    更新日期:2018-04-01 00:00:00

  • Patient injuries in primary total hip replacement.

    abstract::Background and purpose - Although the results of primary total hip replacements (THRs) are generally excellent, sometimes serious complications arise. Some of these severe complications are considered to be patient injuries. We analyzed primary THR-related patient injuries in a nationwide setting. Patients and methods...

    journal_title:Acta orthopaedica

    pub_type: 评论,杂志文章

    doi:10.3109/17453674.2015.1135662

    authors: Helkamaa T,Hirvensalo E,Huhtala H,Remes V

    更新日期:2016-06-01 00:00:00

  • Denervation impairs bone regeneration during distraction osteogenesis in rabbit tibia lengthening.

    abstract:BACKGROUND AND PURPOSES:The nervous system plays an important role in bone metabolism. However, the effect of denervation on bone formation during distraction osteogenesis (DO) remains unclear. We studied neural influence on bone regeneration during DO in a rabbit model. METHODS:24 New Zealand male white rabbits under...

    journal_title:Acta orthopaedica

    pub_type: 杂志文章

    doi:10.3109/17453674.2012.702389

    authors: Song D,Jiang X,Zhu S,Li W,Khadka A,Hu J

    更新日期:2012-08-01 00:00:00

  • Revision of metal-on-metal hip arthroplasty in a tertiary center: a prospective study of 39 hips with between 1 and 4 years of follow-up.

    abstract:BACKGROUND AND PURPOSE:Operative findings during revision of metal-on-metal hip arthroplasty (MOMHA) vary widely and can involve massive soft tissue and bone disruption. As a result, planning of theater time and resources is difficult, surgery is challenging, and outcomes are often poor. We describe our experience with...

    journal_title:Acta orthopaedica

    pub_type: 杂志文章

    doi:10.3109/17453674.2013.797313

    authors: Liddle AD,Satchithananda K,Henckel J,Sabah SA,Vipulendran KV,Lewis A,Skinner JA,Mitchell AW,Hart AJ

    更新日期:2013-06-01 00:00:00

  • High failure rate after internal fixation and beneficial outcome after arthroplasty in treatment of displaced femoral neck fractures in patients between 55 and 70 years.

    abstract::Background and purpose - The treatment of patients between 55 and 70 years with displaced intracapsular femoral neck fracture remains controversial. We compared internal fixation (IF), bipolar hemiarthroplasty (HA) and total hip arthroplasty (THA) in terms of mortality, reoperations and patient-reported outcome by usi...

    journal_title:Acta orthopaedica

    pub_type: 杂志文章

    doi:10.1080/17453674.2017.1376514

    authors: Bartels S,Gjertsen JE,Frihagen F,Rogmark C,Utvåg SE

    更新日期:2018-02-01 00:00:00

  • The effect of impaction and a bioceramic coating on bone ingrowth in porous titanium particles.

    abstract:BACKGROUND AND PURPOSE:Porous titanium (Ti) particles can be impacted like cancellous allograft bone particles, and may therefore be used as bone substitute in impaction grafting. We evaluated the effect of impaction and of a thin silicated biphasic calcium phosphate coating on osteoconduction by Ti particles. METHODS...

    journal_title:Acta orthopaedica

    pub_type: 杂志文章

    doi:10.3109/17453674.2011.579515

    authors: Walschot LH,Schreurs BW,Verdonschot N,Buma P

    更新日期:2011-06-01 00:00:00

  • Uncemented metal-on-metal acetabular component: follow-up of 112 hips for a minimum of 5 years.

    abstract:BACKGROUND:Aseptic loosening is the major cause of implant failure. In cemented hip arthroplasty, failure of the acetabular side is mainly due to lysis caused by wear particles. By using an implant with low wear characteristics and by enhancing acetabular fixation using an uncemented implant, we aimed to reduce acetabu...

    journal_title:Acta orthopaedica

    pub_type: 杂志文章

    doi:10.1080/17453670710014103

    authors: Vassan UT,Sharma S,Chowdary KP,Bhamra MS

    更新日期:2007-08-01 00:00:00

  • Development of the Knee Injury and Osteoarthritis Outcome Score for children (KOOS-Child): comprehensibility and content validity.

    abstract:BACKGROUND AND PURPOSE:The Knee Injury and Osteoarthritis Outcome Score (KOOS) is distinguished from other knee-specific measures by the inclusion of separate scales for evaluation of activities of daily living, sports and recreation function, and knee-related quality of life, with presentation of separate subscale sco...

    journal_title:Acta orthopaedica

    pub_type: 杂志文章

    doi:10.3109/17453674.2012.747921

    authors: Örtqvist M,Roos EM,Broström EW,Janarv PM,Iversen MD

    更新日期:2012-12-01 00:00:00