Abstract:
BACKGROUND:Findings from animal studies and small series of patients support the greater safety of cryoenergy over radiofrequency in the ablation of arrhythmic substrates near the AV node. OBJECTIVES:The purpose of this study was to systematically evaluate the electrophysiologic effects of successive cryoenergy applications to the human AV node in order to better define the safety margin of cryothermal ablation. METHODS:In 15 patients referred for AV nodal ablation, 94 cryomapping and 105 cryoablation applications were delivered through a 6-mm-tip cryothermal ablation catheter (Freezor Xtra, CryoCath) at predefined sites of the triangle of Koch. RESULTS:Temporary effects on AV conduction were observed in 18 (19%) cryomapping and 38 (36%) cryoablation applications. Persistent effects were observed in 9 (9%) cryoablation applications. Persistent effects were associated with cryoablation at the superior third of the triangle of Koch (P = .05), nadir tip temperature < or = -79 degrees C (P = .007), and effect onset time < or =15 seconds (P = .03). Temperature and effect onset time remained statistically significant after multivariate adjustment (P = .01 and .02, respectively). Overall, persistent complete AV block was achieved with cryoenergy in only one patient. In two additional patients, AV conduction remained modified. In the remaining patients, persistent complete AV block was achieved with radiofrequency (median one application per patient). CONCLUSION:The low rate of persistent AV conduction impairment observed with attempts to cryoablate the AV node supports a great safety margin of perinodal cryothermal ablation.
journal_name
Heart Rhythmjournal_title
Heart rhythmauthors
Pérez-Castellano N,Villacastín J,Moreno J,Isa R,Ruiz E,Doblado M,Moreno M,Morales R,Macaya Cdoi
10.1016/j.hrthm.2006.06.002subject
Has Abstractpub_date
2006-10-01 00:00:00pages
1189-95issue
10eissn
1547-5271issn
1556-3871pii
S1547-5271(06)01605-5journal_volume
3pub_type
杂志文章相关文献
HEART RHYTHM文献大全abstract:BACKGROUND:The use of radiofrequency identification (RFID) systems is expanding and highlights the need to address electromagnetic interference (EMI) to implantable pacemakers and implantable cardioverter-defibrillators (ICDs). OBJECTIVE:This study sought to examine the electromagnetic compatibility (EMC) between RFID...
journal_title:Heart rhythm
pub_type: 杂志文章
doi:10.1016/j.hrthm.2009.09.071
更新日期:2010-01-01 00:00:00
abstract:BACKGROUND:Ablation of long-standing persistent atrial fibrillation (AF) is highly variable, with differing techniques and outcomes. OBJECTIVE:The purpose of this study was to undertake a systematic review of the literature with regard to the impact of ablation technique on the outcomes of long-standing persistent AF ...
journal_title:Heart rhythm
pub_type: 杂志文章,评审
doi:10.1016/j.hrthm.2010.01.017
更新日期:2010-06-01 00:00:00
abstract:BACKGROUND:The reported complication rate of catheter ablation of atrial fibrillation (AF) varies. OBJECTIVE:Our goal was to assess temporal trends and the effect of both institutional and individual operators' experience on the incidence of complications. METHODS:All patients undergoing AF ablation at Johns Hopkins ...
journal_title:Heart rhythm
pub_type: 杂志文章
doi:10.1016/j.hrthm.2011.07.025
更新日期:2011-12-01 00:00:00
abstract:BACKGROUND:Areas of conduction delay (CD) or conduction block (CB) are associated with higher recurrence rates after ablation therapy for atrial fibrillation (AF). OBJECTIVE:Thus far, there are no reports on the quantification of the extensiveness of CD and CB at the pulmonary vein area (PVA) and their clinical releva...
journal_title:Heart rhythm
pub_type: 杂志文章
doi:10.1016/j.hrthm.2018.10.027
更新日期:2019-04-01 00:00:00
abstract:BACKGROUND:Mortality caused by ventricular arrhythmias (VAs) remains a problem of epidemic proportions. Understanding current trends on admission of VA, patient characteristics, morbidity, mortality, and health care utilization could help us improve allocation of health care resources and risk prediction. OBJECTIVE:Th...
journal_title:Heart rhythm
pub_type: 杂志文章
doi:10.1016/j.hrthm.2018.09.007
更新日期:2019-03-01 00:00:00
abstract:BACKGROUND:Pulmonary delivery of antiarrhythmic agents has the potential to increase rapidly targeted drug concentrations in pulmonary veins and left atrium to terminate atrial fibrillation (AF). OBJECTIVE:We evaluated the efficacy of flecainide administered via intratracheal instillation in terminating AF in a reliab...
journal_title:Heart rhythm
pub_type: 杂志文章
doi:10.1016/j.hrthm.2018.06.036
更新日期:2018-12-01 00:00:00
abstract:BACKGROUND:Long QT syndrome (LQTS) genetic test reports commonly exclude potentially proarrhythmic common variants such as p.Asp85Asn-KCNE1. OBJECTIVE:The purpose of this study was to determine whether a discernible phenotype is associated with p.Asp85Asn-KCNE1 and whether relatively common KCNE1 variants underlie tra...
journal_title:Heart rhythm
pub_type: 杂志文章
doi:10.1016/j.hrthm.2018.03.038
更新日期:2018-08-01 00:00:00
abstract:BACKGROUND:Hyperthyroidism is a known reversible cause of atrial fibrillation (AF). However, some patients remain in AF despite restoration of euthyroid status. OBJECTIVE:The purpose of this study was to compare the electrophysiologic characteristics and long-term ablation outcome in AF patients with and without histo...
journal_title:Heart rhythm
pub_type: 杂志文章
doi:10.1016/j.hrthm.2015.06.004
更新日期:2015-09-01 00:00:00
abstract::The electrophysiologic substrate underlying the development of ventricular tachycardia (VT) in patients with prior infarction has been studied in depth. An increased understanding of its composition and role in the maintenance of reentrant VT has led to the development of substrate modification approaches to ablation ...
journal_title:Heart rhythm
pub_type: 杂志文章,评审
doi:10.1016/j.hrthm.2009.04.023
更新日期:2009-08-01 00:00:00
abstract:BACKGROUND:With the increasing use of implantable cardioverter-defibrillators (ICDs), device complications are becoming more common. Fungal-related ICD infections have rarely been reported, and little is known about the presentation, prevalence, and treatment options for these morbid infections. OBJECTIVES:The purpose...
journal_title:Heart rhythm
pub_type: 杂志文章
doi:10.1016/j.hrthm.2006.04.012
更新日期:2006-08-01 00:00:00
abstract:BACKGROUND:Magnetic resonance imaging (MRI) scanning of magnetic resonance (MR)-conditional cardiac implantable cardioverter-defibrillators (ICDs) can be performed safely following specific protocols. MRI safety with cardiac resynchronization therapy-defibrillators (CRT-Ds) incorporating quadripolar left ventricular (L...
journal_title:Heart rhythm
pub_type: 杂志文章
doi:10.1016/j.hrthm.2020.08.020
更新日期:2020-12-01 00:00:00
abstract:BACKGROUND:Sudden cardiac death is frequent in patients with lamin A/C gene (LMNA) mutations and may be related to ventricular arrhythmias (VA). OBJECTIVE:To evaluate a strategy of prophylactic implantable cardioverter-defibrillator (ICD) implantation in LMNA mutation carriers with significant cardiac conduction disor...
journal_title:Heart rhythm
pub_type: 杂志文章
doi:10.1016/j.hrthm.2013.06.020
更新日期:2013-10-01 00:00:00
abstract:BACKGROUND:Pulmonary vein (PV) stenosis is an important potential complication of PV isolation using thermal modalities such as radiofrequency ablation (RFA). Pulsed field ablation (PFA) is an alternative energy that causes nonthermal myocardial cell death. OBJECTIVE:The purpose of this study was to compare the effect...
journal_title:Heart rhythm
pub_type: 杂志文章
doi:10.1016/j.hrthm.2020.04.040
更新日期:2020-09-01 00:00:00
abstract:BACKGROUND:The AdaptivCRT algorithm (aCRT) automatically adjusts atrioventricular delays each minute to achieve ventricular fusion through left ventricular (LV) or biventricular (BiV) pacing. aCRT is associated with superior clinical outcomes compared to standard BiV pacing, but the association of aCRT and subsequent a...
journal_title:Heart rhythm
pub_type: 杂志文章
doi:10.1016/j.hrthm.2019.05.012
更新日期:2019-07-01 00:00:00
abstract:BACKGROUND:Cardiac arrest may result from seemingly innocuous medications that do not necessarily have cardiac indications. The best-known example is the drug-induced long QT syndrome. A less known but not necessarily less important form of drug-induced proarrhythmia is the drug-induced Brugada syndrome. OBJECTIVE:The...
journal_title:Heart rhythm
pub_type: 杂志文章
doi:10.1016/j.hrthm.2016.03.016
更新日期:2016-05-01 00:00:00
abstract:BACKGROUND:Outcomes for catheter ablation of accessory pathways in pediatric patients have steadily improved, with the exception of pathways located in the anteroseptal (AS) and midseptal (MS) regions, where success is limited by the close proximity of normal atrioventricular conduction. OBJECTIVE:The purpose of this ...
journal_title:Heart rhythm
pub_type: 杂志文章
doi:10.1016/j.hrthm.2019.12.008
更新日期:2020-05-01 00:00:00
abstract:BACKGROUND:There is a paucity of data regarding the complications and in-hospital mortality after catheter ablation for ventricular tachycardia (VT) in patients with ischemic heart disease. OBJECTIVE:The purpose of this study was to determine the temporal trends in utilization, in-hospital mortality, and complications...
journal_title:Heart rhythm
pub_type: 杂志文章
doi:10.1016/j.hrthm.2014.07.012
更新日期:2014-11-01 00:00:00
abstract:BACKGROUND:Genome-wide association studies (GWAS) have identified common genetic variants that predispose to atrial fibrillation (AF). It is unclear whether rare and low-frequency variants in genes implicated by such GWAS confer additional risk of AF. OBJECTIVE:To study the association of genetic variants with AF at G...
journal_title:Heart rhythm
pub_type: 杂志文章
doi:10.1016/j.hrthm.2013.11.012
更新日期:2014-03-01 00:00:00
abstract:BACKGROUND:The occurrence of congestive heart failure (CHF) hospitalization among patients with atrial fibrillation (AF) is a poor prognostic marker. OBJECTIVE:The purpose of this study was to assess whether insulin-like growth factor-binding protein 7 (IGFBP-7), a marker of myocardial damage, identifies AF patients a...
journal_title:Heart rhythm
pub_type: 杂志文章
doi:10.1016/j.hrthm.2020.11.028
更新日期:2020-12-03 00:00:00
abstract:BACKGROUND:Lead malfunction is an important cause of morbidity and mortality in patients with an implantable cardioverter-defibrillator (ICD). We have shown that the failure of recalled high-voltage leads significantly increases after ICD generator replacement. However, generator replacement has not been recognized as ...
journal_title:Heart rhythm
pub_type: 杂志文章,多中心研究
doi:10.1016/j.hrthm.2014.06.018
更新日期:2014-10-01 00:00:00
abstract:BACKGROUND:Genetic testing for long QT syndrome (LQTS) has been available in a research setting for the past decade, and a commercial test has recently become available. However, the costs and effectiveness of genetic testing have not been estimated. OBJECTIVES:The purpose of this study was to conduct a cost-effective...
journal_title:Heart rhythm
pub_type: 杂志文章
doi:10.1016/j.hrthm.2005.08.026
更新日期:2005-12-01 00:00:00
abstract:BACKGROUND:Because device-related thrombus (DRT) portends a poor prognosis after left atrial appendage closure with the Watchman device, surveillance transesophageal echocardiography (TEE) is recommended at 45 days and 1 year. However, oral anticoagulants are just discontinued at 45 days, rendering this early TEE unlik...
journal_title:Heart rhythm
pub_type: 杂志文章
doi:10.1016/j.hrthm.2020.06.024
更新日期:2020-11-01 00:00:00
abstract::Torsades de pointes (TdP) is a potentially lethal arrhythmia that develops as a consequence of amplification of electrical heterogeneities intrinsic to the ventricular myocardium. These heterogeneities exist because of differences in the time course of repolarization of the three predominant cell types that make up th...
journal_title:Heart rhythm
pub_type: 杂志文章,评审
doi:10.1016/j.hrthm.2004.09.011
更新日期:2005-11-01 00:00:00
abstract:BACKGROUND:Nontransvenous (NTV) implantable cardioverter-defibrillator (ICD) systems with pericardial and/or subcutaneous coils are used in select pediatric and congenital heart disease patients who are not candidates for transvenous ICD leads. Outcomes with these hybrid configurations are not well understood. OBJECTI...
journal_title:Heart rhythm
pub_type: 杂志文章
doi:10.1016/j.hrthm.2009.10.014
更新日期:2010-01-01 00:00:00
abstract:BACKGROUND:The incidence of atrial tachycardia following Fontan surgery is high, but access to the pulmonary venous atrium, a frequent site of arrhythmia origin, is limited. OBJECTIVES:The purpose of this study is to report our results with a novel transthoracic percutaneous technique that provides direct access to th...
journal_title:Heart rhythm
pub_type: 杂志文章
doi:10.1016/j.hrthm.2005.09.027
更新日期:2006-01-01 00:00:00
abstract:BACKGROUND:New approaches to ablation of atrial fibrillation (AF) include focal impulse and rotor modulation (FIRM). Studies of this technology with short-term follow-up have shown favorable outcomes. OBJECTIVE:The purpose of this study was to characterize the long-term results of FIRM ablation in a cohort of patients...
journal_title:Heart rhythm
pub_type: 杂志文章,多中心研究
doi:10.1016/j.hrthm.2015.10.031
更新日期:2016-03-01 00:00:00
abstract:BACKGROUND:The function of the Purkinje system (PS) is to ensure fast and uniform activation of the heart. Although this vital role during sinus rhythm is well understood, this is not the case when shocks are applied to the heart, especially in the case of failed defibrillation. The PS activates differently from the my...
journal_title:Heart rhythm
pub_type: 杂志文章
doi:10.1016/j.hrthm.2009.08.023
更新日期:2009-12-01 00:00:00
abstract:BACKGROUND:Marshall bundles (MBs) are the muscle bundles within the ligament of Marshall. OBJECTIVE:This trial sought to the electrophysiological characteristics of the MB and the anatomical connections between MB and left atrium (LA) in patients with persistent atrial fibrillation (AF). METHODS:We enrolled 72 patien...
journal_title:Heart rhythm
pub_type: 杂志文章
doi:10.1016/j.hrthm.2010.02.028
更新日期:2010-06-01 00:00:00
abstract:BACKGROUND:Prolongation of the PR interval has been associated with an increased risk of incident atrial fibrillation (AF). OBJECTIVE:To determine if there was a nonlinear relation between PR interval duration and the risk of AF. METHODS:We included 288,181 individuals, corresponding to one third of the population in...
journal_title:Heart rhythm
pub_type: 杂志文章
doi:10.1016/j.hrthm.2013.04.012
更新日期:2013-09-01 00:00:00
abstract:BACKGROUND:Nonrheumatic atrial fibrillation (AF) is a common cause of embolic stroke. Warfarin therapy can reduce stroke risk by two-thirds in patients with AF, but therapy may not always be used or always be used optimally. OBJECTIVES:This study sought to document the patterns of anticoagulant use and the determinant...
journal_title:Heart rhythm
pub_type: 杂志文章
doi:10.1016/j.hrthm.2008.07.014