Long-term outcome after surgical treatment of arterial lesions in Behçet disease.

Abstract:

OBJECTIVE:Surgical treatment of arterial lesions associated with Behçet disease (BD) is often complicated by graft occlusion and recurrence of aneurysms. The purpose of this study was to clarify the long-term outcome of surgical intervention for arterial involvement in BD. METHODS:Ten patients with BD (9 men, 1 woman) who underwent surgical treatment for arterial aneurysms between 1980 and 2004 were included in the study. The age of patients at the first operation ranged from 36 to 69 years (mean, 50.4 +/- 9.0 years). The mean period between the onset of BD and that of arterial manifestations was 8.0 +/- 5.0 years. We retrospectively reviewed their postoperative courses, including survival, graft occlusion, formation of anastomotic false aneurysms, and the development of aneurysms at different sites. The Kaplan-Meier method was used to calculate the chronologic incidence of complications after surgery. RESULTS:The mean follow-up period was 133 +/- 92 months, ranging from 5 to 285 months. One patient died of rupture of a dissecting aortic aneurysm after undergoing several surgical interventions for multiple aneurysms. There were five graft occlusions among 21 grafts. The cumulative primary graft patency rate in the infrainguinal region was 83.9% at 3 years. Five anastomotic false aneurysms formed among 49 anastomoses between grafts and host arteries. The overall cumulative incidence of formation of anastomotic pseudoaneurysm was 12.9% at 5 and 10 years. All of them formed within 18 months after surgery. Development of new aneurysms in different arteries was observed in two patients. CONCLUSIONS:Early occurrence of anastomotic false aneurysm is characteristic of BD. Further investigation is necessary to establish effective postoperative treatment.

journal_name

J Vasc Surg

authors

Hosaka A,Miyata T,Shigematsu H,Shigematsu K,Okamoto H,Ishii S,Miyahara T,Yamamoto K,Akagi D,Nagayoshi M,Nagawa H

doi

10.1016/j.jvs.2005.03.019

subject

Has Abstract

pub_date

2005-07-01 00:00:00

pages

116-21

issue

1

eissn

0741-5214

issn

1097-6809

pii

S074152140500457X

journal_volume

42

pub_type

杂志文章
  • Lateral venous ulcer and short saphenous vein insufficiency.

    abstract:PURPOSE:The objective of this report is to emphasize the importance of saphenopopliteal junction (SPJ) reflux in the genesis of lateral leg ulcers and to suggest a proper diagnostic and therapeutic approach. METHODS:Twenty legs with isolated lateral perimalleolar ulcers from the basis for this report. None had medial ...

    journal_title:Journal of vascular surgery

    pub_type: 杂志文章

    doi:10.1016/s0741-5214(97)70291-x

    authors: Bass A,Chayen D,Weinmann EE,Ziss M

    更新日期:1997-04-01 00:00:00

  • Hyperglycemia limits experimental aortic aneurysm progression.

    abstract:OBJECTIVE:Diabetes mellitus (DM) is associated with reduced progression of abdominal aortic aneurysm (AAA) disease. Mechanisms responsible for this negative association remain unknown. We created AAAs in hyperglycemic mice to examine the influence of serum glucose concentration on experimental aneurysm progression. ME...

    journal_title:Journal of vascular surgery

    pub_type: 杂志文章

    doi:10.1016/j.jvs.2010.05.086

    authors: Miyama N,Dua MM,Yeung JJ,Schultz GM,Asagami T,Sho E,Sho M,Dalman RL

    更新日期:2010-10-01 00:00:00

  • Transforming growth factor-beta1 antisense treatment of rat vein grafts reduces the accumulation of collagen and increases the accumulation of h-caldesmon.

    abstract:BACKGROUND:The main cause of occlusion and vein graft failure after peripheral and coronary arterial reconstruction is intimal hyperplasia. Transforming growth factor beta-1 (TGF-beta1) is a pleiotropic cytokine known to have powerful effects on cell growth, apoptosis, cell differentiation, and extracellular matrix syn...

    journal_title:Journal of vascular surgery

    pub_type: 杂志文章

    doi:10.1016/j.jvs.2006.01.016

    authors: Wolff RA,Malinowski RL,Heaton NS,Hullett DA,Hoch JR

    更新日期:2006-05-01 00:00:00

  • Duplex sonography accurately assesses portacaval shunt patency.

    abstract::Among 42 patients who had undergone portacaval shunt (PCS) to treat bleeding esophageal varices, shunt patency was assessed with duplex sonography 1 month to 5 years postoperatively. Patency was confirmed in all patients (100%). Correlative angiograms confirming the sonographic findings were obtained in 24 patients. D...

    journal_title:Journal of vascular surgery

    pub_type: 杂志文章

    doi:10.1067/mva.1988.avs0080657

    authors: Helton WS,Montana MA,Dwyer DC,Johansen K

    更新日期:1988-12-01 00:00:00

  • Anesthetic type and hospital outcomes after carotid endarterectomy from the Vascular Quality Initiative database.

    abstract:OBJECTIVE:Studies on the safety of carotid endarterectomy (CEA) under different anesthetic techniques are sometimes contradictory. The aim of this study was to compare real-world outcomes of CEA under general anesthesia (GA) vs regional or local anesthesia (RA/LA). METHODS:A retrospective analysis of the Vascular Qual...

    journal_title:Journal of vascular surgery

    pub_type: 杂志文章

    doi:10.1016/j.jvs.2017.09.028

    authors: Dakour Aridi H,Paracha N,Nejim B,Locham S,Malas MB

    更新日期:2018-05-01 00:00:00

  • Revised duplex criteria and outcomes for renal stents and stent grafts following endovascular repair of juxtarenal and thoracoabdominal aneurysms.

    abstract:OBJECTIVES:To assess outcomes and develop duplex scan criteria that will reliably determine the luminal status of covered and uncovered renal stents following fenestrated and branched endovascular repair. METHODS:A prospective database of patients treated with fenestrated and branched endografts between 2001 and 2006 ...

    journal_title:Journal of vascular surgery

    pub_type: 杂志文章

    doi:10.1016/j.jvs.2008.11.024

    authors: Mohabbat W,Greenberg RK,Mastracci TM,Cury M,Morales JP,Hernandez AV

    更新日期:2009-04-01 00:00:00

  • Oxidized LDL in human carotid plaques is related to symptomatic carotid disease and lesion instability.

    abstract:BACKGROUND:Oxidative stress is an important determinant in atherosclerosis development. Various markers of oxidative stress, such as oxidation of low-density lipoprotein (LDL), nitrosative stress, lipid peroxidation, and protein oxidation, have been implicated in the initiation and/or progression of atherosclerosis, bu...

    journal_title:Journal of vascular surgery

    pub_type: 杂志文章

    doi:10.1016/j.jvs.2010.03.047

    authors: Sigala F,Kotsinas A,Savari P,Filis K,Markantonis S,Iliodromitis EK,Gorgoulis VG,Andreadou I

    更新日期:2010-09-01 00:00:00

  • Infected infrarenal aortic aneurysms: when is in situ reconstruction safe?

    abstract::Twenty-five infected infrarenal aortic aneurysms operated on between 1968 and 1989 were reviewed. They were classified into post-embolic (mycotic) aneurysms (group I), infective aortitis (group II), and infected atherosclerotic aneurysms (group III). Aortoduodenal fistulas were found in eight patients and aortocaval i...

    journal_title:Journal of vascular surgery

    pub_type: 杂志文章,评审

    doi:10.1067/mva.1993.38670

    authors: Fichelle JM,Tabet G,Cormier P,Farkas JC,Laurian C,Gigou F,Marzelle J,Acar J,Cormier JM

    更新日期:1993-04-01 00:00:00

  • Accurate assessment of abdominal aortic aneurysm with intravascular ultrasound scanning: validation with computed tomographic angiography.

    abstract:PURPOSE:The purpose of this study was to assess the accuracy of intravascular ultrasound (IVUS) parameters of abdominal aortic aneurysm, used for endovascular grafting, in comparison with computed tomographic angiography (CTA). METHODS:This study was designed as a descriptive study. Between March 1997 and March 1998, ...

    journal_title:Journal of vascular surgery

    pub_type: 杂志文章

    doi:10.1016/s0741-5214(99)70308-3

    authors: van Essen JA,Gussenhoven EJ,van der Lugt A,Huijsman PC,van Muiswinkel JM,van Sambeek MR,van Dijk LC,van Urk H

    更新日期:1999-04-01 00:00:00

  • External iliac artery dissection secondary to endofibrosis in a cyclist.

    abstract::Endofibrosis of the external iliac artery is an uncommon disease affecting primarily young, otherwise healthy, endurance athletes. Thigh pain during maximal exercise with quick resolution postexercise is characteristic of the so-called cyclist's iliac syndrome. We report an unusual case in which the typical endofibrot...

    journal_title:Journal of vascular surgery

    pub_type: 杂志文章,评审

    doi:10.1016/j.jvs.2010.02.259

    authors: Willson TD,Revesz E,Podbielski FJ,Blecha MJ

    更新日期:2010-07-01 00:00:00

  • No major difference in outcomes for endovascular aneurysm repair stent grafts placed outside of instructions for use.

    abstract:OBJECTIVE:Studies have shown that a sizable percentage of endovascular aneurysm repair (EVAR) for abdominal aortic aneurysms (AAAs) is performed outside the instructions for use (IFU). We report our long-term outcomes after EVAR with respect to device-specific IFU. METHODS:Computed tomography angiography data from a c...

    journal_title:Journal of vascular surgery

    pub_type: 杂志文章

    doi:10.1016/j.jvs.2016.01.034

    authors: Beckerman WE,Tadros RO,Faries PL,Torres M,Wengerter SP,Vouyouka AG,Lookstein RA,Marin ML

    更新日期:2016-07-01 00:00:00

  • Acute reductions in mechanical wall strain precede the formation of intimal hyperplasia in a murine model of arterial occlusive disease.

    abstract:OBJECTIVE:Intimal hyperplasia (IH) continues to plague the durability of vascular interventions. Employing a validated murine model, ultrasound biomicroscopy, and speckle-tracking algorithms, we tested the hypothesis that reduced cyclic arterial wall strain results in accentuated arterial wall IH. METHODS:A 9-0 suture...

    journal_title:Journal of vascular surgery

    pub_type: 杂志文章

    doi:10.1016/j.jvs.2013.07.113

    authors: Favreau JT,Liu C,Yu P,Tao M,Mauro C,Gaudette GR,Ozaki CK

    更新日期:2014-11-01 00:00:00

  • Obtaining a superficial femoral artery graft in adolescents and children with the deep femoral artery transposition.

    abstract::A new technique to obtain a segment of the superficial femoral artery as an arterial conduit in young patients while an unobstructed peripheral blood flow is maintained by superficial femoral artery-deep femoral artery transposition is illustrated with two clinical examples. The explanted arterial autograft requires n...

    journal_title:Journal of vascular surgery

    pub_type: 杂志文章

    doi:10.1067/mva.2001.109762

    authors: Bednarkiewicz M,Vala D,Khatchourian G,Kadry Z,Morel P,Christenson JT,Faidutti B

    更新日期:2001-02-01 00:00:00

  • The efficacy of a new portable sequential compression device (SCD Express) in preventing venous stasis.

    abstract:OBJECTIVE:It has been previously shown that the SCD Response Compression System, by sensing the postcompression refill time of the lower limbs, delivers more compression cycles over time, resulting in as much as a 76% increase in the total volume of blood expelled per hour. Extended indications for pneumatic compressio...

    journal_title:Journal of vascular surgery

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1016/j.jvs.2005.03.031

    authors: Kakkos SK,Griffin M,Geroulakos G,Nicolaides AN

    更新日期:2005-08-01 00:00:00

  • Multiple organ dysfunction after mesenteric artery revascularization.

    abstract:PURPOSE:Mesenteric arterial reconstruction in patients with acute or chronic intestinal ischemia is associated with significant morbidity and mortality rates. Reperfusion of ischemic bowel in animals leads to release of multiple factors that cause organ dysfunction. Similar phenomena potentially occur in human beings a...

    journal_title:Journal of vascular surgery

    pub_type: 杂志文章

    doi:10.1067/mva.1993.48586

    authors: Harward TR,Brooks DL,Flynn TC,Seeger JM

    更新日期:1993-09-01 00:00:00

  • Restenosis in gold-coated renal artery stents.

    abstract:BACKGROUND:Gold coating improves stent visibility under fluoroscopy. This is particularly valuable for precise stent placement during renal artery stenting (RAS). There is conflicting evidence regarding restenosis with gold-coated stents. To evaluate the effect of gold coating on restenosis after renal stenting, we rev...

    journal_title:Journal of vascular surgery

    pub_type: 杂志文章

    doi:10.1016/j.jvs.2005.03.038

    authors: Nolan BW,Schermerhorn ML,Powell RJ,Rowell E,Fillinger MF,Rzucidlo EM,Wyers MC,Whittaker D,Zwolak RM,Walsh DB,Cronenwett JL

    更新日期:2005-07-01 00:00:00

  • Comparison of posterior and medial approaches for popliteal artery aneurysms.

    abstract:BACKGROUND:Long-term results of the posterior approach (PA) for the treatment of popliteal artery aneurysms are lacking in the literature. We reviewed our experience during a 13-year period in patients with popliteal artery aneurysms, comparing those treated through a PA with those operated on through a standard medial...

    journal_title:Journal of vascular surgery

    pub_type: 杂志文章

    doi:10.1016/j.jvs.2015.06.227

    authors: Mazzaccaro D,Carmo M,Dallatana R,Settembrini AM,Barbetta I,Tassinari L,Roveri S,Settembrini PG

    更新日期:2015-12-01 00:00:00

  • Successful use of minimal incision superficialization technique for arteriovenous fistula maturation.

    abstract:BACKGROUND:Successful cannulation is an important prerequisite for a functional arteriovenous fistula (AVF). Reasons for unsuccessful cannulation of an AVF are multifactorial and poorly evaluated. In our experience, a needle access segment (NAS) with a length of 10 cm, <5 mm deep from the skin surface, and >6 mm diamet...

    journal_title:Journal of vascular surgery

    pub_type: 杂志文章

    doi:10.1016/j.jvs.2015.10.063

    authors: Inkollu S,Wellen J,Beller Z,Zhang T,Vachharajani N,Shenoy S

    更新日期:2016-04-01 00:00:00

  • Management of patients with acute aortic syndrome through a regional rapid transport system.

    abstract:OBJECTIVE:The objective of this study was to describe the outcomes of patients with acute aortic syndrome (AAS) during and after transfer to a regional aortic center by a rapid transport system. METHODS:Review of patients with AAS who were transferred by a rapid transport system to a regional aortic center was perform...

    journal_title:Journal of vascular surgery

    pub_type: 杂志文章

    doi:10.1016/j.jvs.2016.08.081

    authors: Manzur M,Han SM,Dunn J,Elsayed RS,Fleischman F,Casagrande Y,Weaver FA

    更新日期:2017-01-01 00:00:00

  • The impact of socioeconomic factors on outcome and hospital costs associated with femoropopliteal revascularization.

    abstract:INTRODUCTION:Within the context of healthcare system reform, the cost efficacy of lower extremity revascularization remains a timely topic. The impact of an individual patient's socioeconomic status represents an under-studied aspect of vascular care, especially with respect to longitudinal costs and outcomes. The purp...

    journal_title:Journal of vascular surgery

    pub_type: 杂志文章

    doi:10.1016/j.jvs.2010.04.011

    authors: Durham CA,Mohr MC,Parker FM,Bogey WM,Powell CS,Stoner MC

    更新日期:2010-09-01 00:00:00

  • Initial successful management of type I endoleak after endovascular aortic aneurysm repair with n-butyl cyanoacrylate adhesive.

    abstract:OBJECTIVE:Transcatheter embolization with coils and other agents has been described as a treatment method for type II endoleak after endovascular aortic aneurysm repair (EVAR). Type I endoleak has not been treated commonly with such therapies, although most investigators believe they warrant definitive intervention. Th...

    journal_title:Journal of vascular surgery

    pub_type: 杂志文章

    doi:10.1016/s0741-5214(03)00729-8

    authors: Maldonado TS,Rosen RJ,Rockman CB,Adelman MA,Bajakian D,Jacobowitz GR,Riles TS,Lamparello PJ

    更新日期:2003-10-01 00:00:00

  • Deep venous thrombosis after radiofrequency ablation of greater saphenous vein: a word of caution.

    abstract:PURPOSE:Radiofrequency ablation (RFA) of the greater saphenous vein (GSV; "closure") is a relatively new option for treatment of venous reflux. However, our initial enthusiasm for this minimally invasive technique has been tempered by our preliminary experience with its potentially lethal complication, deep venous thro...

    journal_title:Journal of vascular surgery

    pub_type: 杂志文章

    doi:10.1016/j.jvs.2004.04.032

    authors: Hingorani AP,Ascher E,Markevich N,Schutzer RW,Kallakuri S,Hou A,Nahata S,Yorkovich W,Jacob T

    更新日期:2004-09-01 00:00:00

  • Midline retroperitoneal versus midline transperitoneal approach for abdominal aortic aneurysm repair.

    abstract:PURPOSE:The purpose of this study was to compare the midline retroperitoneal approach with the midline transperitoneal approach for abdominal aortic aneurysm (AAA) repair with respect to operative details, gastrointestinal complications, and wound complications. METHODS:From January 1990 through January 1998, 128 pati...

    journal_title:Journal of vascular surgery

    pub_type: 临床试验,杂志文章

    doi:10.1067/mva.2000.106946

    authors: Nakajima T,Kawazoe K,Komoda K,Sasaki T,Ohsawa S,Kamada T

    更新日期:2000-08-01 00:00:00

  • Deterministic effects after fenestrated endovascular aortic aneurysm repair.

    abstract:BACKGROUND:Endovascular aortic aneurysm repairs (EVARs) with fenestrated (FEVAR) stent grafts are high radiation dose cases, yet no skin injuries were found retrospectively in our 61 cases with a mean peak skin dose (PSD) of 6.8 Gy. We hypothesize that skin injury is under-reported. This study examined deterministic ef...

    journal_title:Journal of vascular surgery

    pub_type: 杂志文章

    doi:10.1016/j.jvs.2014.11.044

    authors: Kirkwood ML,Arbique GM,Guild JB,Timaran C,Anderson JA,Valentine RJ

    更新日期:2015-04-01 00:00:00

  • Predictors of bleeding or anemia requiring transfusion in complex endovascular aortic repair and its impact on outcomes in health insurance claims.

    abstract:OBJECTIVE:This study aimed to determine predictors and outcomes associated with bleeding or anemia requiring transfusion (BAT) after fenestrated or branched endovascular aneurysm repair (FB-EVAR). METHODS:Health insurance claims data of Germany's third largest insurance provider, DAK-Gesundheit, were used to investiga...

    journal_title:Journal of vascular surgery

    pub_type: 杂志文章,多中心研究

    doi:10.1016/j.jvs.2019.02.059

    authors: Behrendt CA,Debus ES,Schwaneberg T,Rieß HC,Dankhoff M,Makaloski V,Sedrakyan A,Kölbel T

    更新日期:2020-02-01 00:00:00

  • Surgical treatment of visceral artery aneurysms: A 25-year experience.

    abstract:OBJECTIVE:The aim of this study was to analyze our 25-year experience with surgical treatment of visceral artery aneurysms (VAAs), with particular attention paid to early and long-term results. MATERIALS AND METHODS:From January 1982 to September 2007, 55 patients (32 males, 58%, and 23 females, 42%) underwent surgica...

    journal_title:Journal of vascular surgery

    pub_type: 杂志文章

    doi:10.1016/j.jvs.2008.03.043

    authors: Pulli R,Dorigo W,Troisi N,Pratesi G,Innocenti AA,Pratesi C

    更新日期:2008-08-01 00:00:00

  • New temporary internal introducer shunt for brain perfusion during total endovascular arch replacement with in situ fenestration technique.

    abstract::Complete endovascular arch replacement by in situ fenestration technique requires maintenance of cerebral perfusion during the fenestration procedure by an extracorporeal femoral-carotid bypass. The bypass has the disadvantages of being invasive, requiring a pump, and shunting blood extracorporeally. This report descr...

    journal_title:Journal of vascular surgery

    pub_type: 杂志文章

    doi:10.1016/j.jvs.2012.04.064

    authors: Sonesson B,Resch T,Dias N,Malina M

    更新日期:2012-10-01 00:00:00

  • Early report from an investigator-initiated investigational device exemption clinical trial on physician-modified endovascular grafts.

    abstract:OBJECTIVE:To determine whether a physician-modified endovascular graft (PMEG) is a safe and effective method for treating patients with juxtarenal aortic aneurysms who are deemed unsuitable for open repair. METHODS:A nonrandomized, prospective, consecutively enrolling investigational device exemption clinical trial wa...

    journal_title:Journal of vascular surgery

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jvs.2013.01.029

    authors: Starnes BW,Tatum B

    更新日期:2013-08-01 00:00:00

  • Anatomic characteristics and natural history of renal artery aneurysms during longitudinal imaging surveillance.

    abstract:OBJECTIVE:Renal artery aneurysms (RAAs) are uncommon, and rates of growth and rupture are unknown. Limited evidence therefore exists to guide clinical management of RAAs, particularly small aneurysms that are asymptomatic. To further characterize the natural history of RAAs, we studied anatomic characteristics and chan...

    journal_title:Journal of vascular surgery

    pub_type: 杂志文章

    doi:10.1016/j.jvs.2014.03.006

    authors: Wayne EJ,Edwards MS,Stafford JM,Hansen KJ,Corriere MA

    更新日期:2014-08-01 00:00:00

  • Long-term survival and secondary procedures after open or endovascular repair of abdominal aortic aneurysms.

    abstract:OBJECTIVE:Randomized trials have shown an initial survival benefit of endovascular over conventional open abdominal aortic aneurysm repair but no long-term difference up to 6 years after repair. Longer follow-up may be required to demonstrate the cumulative negative impact on survival of higher reintervention rates ass...

    journal_title:Journal of vascular surgery

    pub_type: 杂志文章,多中心研究,随机对照试验

    doi:10.1016/j.jvs.2017.05.122

    authors: van Schaik TG,Yeung KK,Verhagen HJ,de Bruin JL,van Sambeek MRHM,Balm R,Zeebregts CJ,van Herwaarden JA,Blankensteijn JD,DREAM trial participants.

    更新日期:2017-11-01 00:00:00