Effect of electromyogram biofeedback on daytime clenching behavior in subjects with masticatory muscle pain.

Abstract:

PURPOSE:Although daytime clenching is believed to be one of the oral parafunctions leading to dental problems, a treatment strategy has not yet been devised. Electromyogram (EMG) biofeedback training was performed to ascertain its effect on the regulation of daytime clenching behavior. MATERIALS AND METHODS:Twenty subjects (mean age, 30.9±5.6 years) who had mild to moderate masticatory muscle pain with daytime clenching behavior were randomly divided into either a biofeedback group (BF) or control group (CO). Subjects were fitted with a hearing-aid-shaped EMG recording and biofeedback apparatus which was used to record EMG data under natural conditions from the temporal muscle, continuously for five hours on four consecutive days. EMG data on Days 1 and 4 were recorded without biofeedback as pre-test and post-test, respectively, and on Days 2 and 3, subjects in the BF group noticed their clenching behaviors via an alert sound from the EMG biofeedback apparatus. No alert sound was given for the CO group throughout the recording sessions. RESULTS:There was no significant difference in the number of clenching events for five hours between the BF group (4.6±2.5) and CO group (4.6±0.9) on Day 1, however a significant decrease was found in the BF group between Day 1 (4.6±2.5) and Day 4 (2.4±1.7; P<0.05). CONCLUSION:Daytime clenching was reduced in the short-term with the help of an EMG biofeedback system under natural circumstances. Further research is needed to confirm a long-lasting effect.

journal_name

J Prosthodont Res

authors

Watanabe A,Kanemura K,Tanabe N,Fujisawa M

doi

10.1016/j.jpor.2010.09.003

subject

Has Abstract

pub_date

2011-04-01 00:00:00

pages

75-81

issue

2

eissn

1883-1958

issn

2212-4632

pii

S1883-1958(10)00113-1

journal_volume

55

pub_type

杂志文章,随机对照试验
  • Microstructural, mechanical, ionic release and tarnish resistance characterization of porcelain fused to metal Co-Cr alloys manufactured via casting and three different CAD/CAM techniques.

    abstract:PURPOSE:To perform a comparative analysis of the microstructure, porosity, mechanical properties, corrosion, and tarnish resistance of Co-Cr alloys prepared by casting and three different computer aided designed/computer aided manufacturing (CAD/CAM) techniques. METHODS:Four groups of metallic specimens were prepared,...

    journal_title:Journal of prosthodontic research

    pub_type: 杂志文章

    doi:10.1016/j.jpor.2018.10.008

    authors: Al Jabbari YS,Barmpagadaki X,Psarris I,Zinelis S

    更新日期:2019-04-01 00:00:00

  • Three-dimensional trueness and margin quality of monolithic zirconia restorations fabricated by additive 3D gel deposition.

    abstract:PURPOSE:The aim of this in vitro study was to evaluate the three-dimensional trueness and margin quality of monolithic zirconia restorations fabricated by additive 3D gel deposition, compared with those by subtractive milling. METHODS:Ten single crowns and ten 4-unit FPDs of different occlusal geometries and margin th...

    journal_title:Journal of prosthodontic research

    pub_type: 杂志文章

    doi:10.1016/j.jpor.2020.01.002

    authors: Li R,Chen H,Wang Y,Zhou Y,Shen Z,Sun Y

    更新日期:2020-10-01 00:00:00

  • Investigation of accuracy and reproducibility of abutment position by intraoral scanners.

    abstract:PURPOSE:We examined the accuracy, including trueness and precision, of the intraoral scanners comparing with laboratory scanner to reveal the error level of intraoral scanners. METHODS:Measurements were performed using a computer numerical control coordinate measuring machine (CNCCMM) of the reference models as a cont...

    journal_title:Journal of prosthodontic research

    pub_type: 杂志文章

    doi:10.1016/j.jpor.2017.01.005

    authors: Fukazawa S,Odaira C,Kondo H

    更新日期:2017-10-01 00:00:00

  • Fabrication of crown restoration retrofitting to existing clasps using CAD/CAM: fitness accuracy and retentive force.

    abstract:PURPOSE:A crown restoration engaged by a clasp as an abutment tooth for a removable partial denture (RPD) occasionally might be removed and eliminated due to secondary caries or apical lesions. However, if the RPD is clinically acceptable without any problems and refabricating the RPD is not recommended, the new crown ...

    journal_title:Journal of prosthodontic research

    pub_type: 杂志文章

    doi:10.1016/j.jpor.2015.01.002

    authors: Ozawa D,Suzuki Y,Kawamura N,Ohkubo C

    更新日期:2015-04-01 00:00:00

  • Full arch digital scanning systems performances for implant-supported fixed dental prostheses: a comparative study of 8 intraoral scanners.

    abstract:PURPOSE:Compare the accuracy of intraoral digital impression in full-arch implant-supported fixed dental prosthesis acquired with eight different intraoral scanner (Ios). METHODS:A polymethyl methacrylate acrylic model of an edentulous mandible with six scan-abutment was used as a master model and its dimensions measu...

    journal_title:Journal of prosthodontic research

    pub_type: 杂志文章

    doi:10.1016/j.jpor.2019.04.002

    authors: Di Fiore A,Meneghello R,Graiff L,Savio G,Vigolo P,Monaco C,Stellini E

    更新日期:2019-10-01 00:00:00

  • Sensory trick splint as a multimodal therapy for oromandibular dystonia.

    abstract:PURPOSE:Many patients with oromandibular dystonia, which is characterized by involuntary masticatory, lower facial, and/or tongue muscle contractions, experience relief of symptoms through sensory tricks such as eating chewing gum or candy. The aim of this study was to identify the factors influencing the effects of sp...

    journal_title:Journal of prosthodontic research

    pub_type: 杂志文章

    doi:10.1016/j.jpor.2017.09.004

    authors: Yoshida K

    更新日期:2018-04-01 00:00:00

  • Association of fixed partial denture and gingival prosthesis as alternative approach to recover esthetics and function in anterior maxillary region.

    abstract::Tooth replacement in the maxillary anterior region is especially difficult when the loss includes significant amounts of the residual ridge and the soft tissue. Several techniques are available, such as dental implants or fixed partial denture, and bone and gingival grafts or gingival prostheses, respectively. This ar...

    journal_title:Journal of prosthodontic research

    pub_type: 杂志文章

    doi:10.1016/j.jpor.2012.02.003

    authors: Ajita CO,Anchieta RB,Martin M Jr,Archangelo CM,Gil NR,Bertoncelo CA,Nesello DG

    更新日期:2012-07-01 00:00:00

  • Evaluation of the Candida albicans removal and mechanical properties of denture acrylics cleaned by a low-cost powered toothbrush.

    abstract:PURPOSE:To investigate the effects of using a low-cost powered toothbrush for cleaning on dental prostheses made of heat polymerized poly(methyl methacrylate), PMMA. METHODS:Heat cured PMMA specimens beam with the dimensions of 45.0 mm×6.5 mm×4.5mm were fabricated. The specimens were kept in water storage at 37 °C con...

    journal_title:Journal of prosthodontic research

    pub_type: 杂志文章

    doi:10.1016/j.jpor.2014.06.002

    authors: Tan CM,Tsoi JK,Seneviratne CJ,Matinlinna JP

    更新日期:2014-10-01 00:00:00

  • Influence of atmospheric pressure low-temperature plasma treatment on the shear bond strength between zirconia and resin cement.

    abstract:PURPOSE:Zirconia exhibits excellent strength and high biocompatibility in technological applications and it is has therefore been investigated for clinical applications and research. Before setting prostheses, a crown prosthesis inner surface is sandblasted with alumina to remove contaminants and form small cavities. T...

    journal_title:Journal of prosthodontic research

    pub_type: 杂志文章

    doi:10.1016/j.jpor.2016.02.001

    authors: Ito Y,Okawa T,Fukumoto T,Tsurumi A,Tatsuta M,Fujii T,Tanaka J,Tanaka M

    更新日期:2016-10-01 00:00:00

  • Mechanical properties of new denture base material modified with gold  nanoparticles.

    abstract:PURPOSE:Poly(methyl methacrylate) (PMMA) is the most commonly used material in the production of dental prostheses, and its application is often accompanied by the formation of biofilm. The aim of this work was the preparation of a PMMA/gold nanoparticles (AuNps) composite to improve the antimicrobial properties of hea...

    journal_title:Journal of prosthodontic research

    pub_type: 杂志文章

    doi:10.2186/jpr.JPOR_2019_581

    authors: Tijana A,Valentina V,Nataša T,Miloš HM,Atlagić Suzana G,Milica B,Yoshiyuki H,Hironori S,Ivanič A,Rebeka R

    更新日期:2020-09-09 00:00:00

  • The number of implants required to support a maxillary overdenture: a systematic review and meta-analysis.

    abstract:PURPOSE:The number of implants needed to support a maxillary overdenture is still a controversial issue. The aim of this systematic review was to investigate the number of implants required to support a maxillary overdenture in order to obtain optimal treatment outcomes in terms of implant survival, overdenture longevi...

    journal_title:Journal of prosthodontic research

    pub_type: 杂志文章,meta分析

    doi:10.1016/j.jpor.2018.08.006

    authors: Di Francesco F,De Marco G,Gironi Carnevale UA,Lanza M,Lanza A

    更新日期:2019-01-01 00:00:00

  • Mandibular movement during sleep bruxism associated with current tooth attrition.

    abstract:PATIENT:Observation of attrition patterns suggests that mandibular movement in sleep bruxism (SB) may be associated with current tooth attrition. The aim of this study was to confirm this phenomenon by investigating mandibular movement and masseter muscle activity. The subject was a healthy 21-year-old Japanese male. W...

    journal_title:Journal of prosthodontic research

    pub_type: 杂志文章

    doi:10.1016/j.jpor.2016.06.003

    authors: Okura K,Shigemoto S,Suzuki Y,Noguchi N,Omoto K,Abe S,Matsuka Y

    更新日期:2017-01-01 00:00:00

  • Influence of block-out on retentive force of thermoplastic resin clasps: an in vitro experimental and finite element analysis.

    abstract:PURPOSE:The purpose of this study was to determine the effect of block-out preparation, used to eliminate the undercut area, on the retentive force and stress distribution of resin clasps. METHODS:A total of 72 polyester and polyamide resin clasps were fabricated on a premolar abutment crown following six block-out pr...

    journal_title:Journal of prosthodontic research

    pub_type: 杂志文章

    doi:10.1016/j.jpor.2019.01.002

    authors: Yamazaki T,Murakami N,Suzuki S,Handa K,Yatabe M,Takahashi H,Wakabayashi N

    更新日期:2019-07-01 00:00:00

  • Comparison of fracture resistance between cast, CAD/CAM milling, and direct metal laser sintering metal post systems.

    abstract:PURPOSE:The purpose of this study was to compare the fracture resistance of Co-Cr post-cores fabricated with 3 different techniques: traditional casting (TC), computer-aided design and manufacturing (CAD/CAM) milling (CCM) and direct metal laser sintering (DMLS). METHODS:Forty intact human mandibular premolar were end...

    journal_title:Journal of prosthodontic research

    pub_type: 杂志文章

    doi:10.1016/j.jpor.2015.08.001

    authors: Bilgin MS,Erdem A,Dilber E,Ersoy İ

    更新日期:2016-01-01 00:00:00

  • One step polymerizing technique for fabricating a hollow obturator.

    abstract:PURPOSE:Although a closed hollow obturator is often applied to post maxillectomy patients, it has a few problems such as complexity of fabrication and water leakage to inside. A one step curing technique to fabricate a closed hollow obturator by constructing a small hollow bulb made by two thermoplastic resin sheets is...

    journal_title:Journal of prosthodontic research

    pub_type: 杂志文章

    doi:10.1016/j.jpor.2013.08.003

    authors: Hori K,Miyamoto T,Ono T,Yamamoto M,Shiroshita N,Maeda Y,Inoue M

    更新日期:2013-10-01 00:00:00

  • Effect of adding silver nanoparticle on physical and mechanical properties of maxillofacial silicone elastomer material-an in-vitro study.

    abstract:PURPOSE:The purpose of this study was to evaluate the impact of silver nanoparticle incorporation into maxillofacial silicone material on its hardness, tear strength and color stability. METHODS:A total of 180 silicone specimens were fabricated according to the specification of American society for material and testin...

    journal_title:Journal of prosthodontic research

    pub_type: 杂志文章

    doi:10.1016/j.jpor.2019.12.001

    authors: Sonnahalli NK,Chowdhary R

    更新日期:2020-10-01 00:00:00

  • Comparison of patient-reported outcomes between immediately and conventionally loaded mandibular two-implant overdentures: A preliminary study.

    abstract:PURPOSE:The aim of this preliminary study is to compare patient-reported outcomes between immediately and conventionally loaded mandibular two-implant overdentures retained by magnetic attachments. METHODS:Nineteen participants with edentulous mandibles were randomly assigned into either an immediate loading group (im...

    journal_title:Journal of prosthodontic research

    pub_type: 杂志文章

    doi:10.1016/j.jpor.2015.12.010

    authors: Omura Y,Kanazawa M,Sato D,Kasugai S,Minakuchi S

    更新日期:2016-07-01 00:00:00

  • Pressure transmission area and maximum pressure transmission of different thermoplastic resin denture base materials under impact load.

    abstract:PURPOSES:The purposes of the present study were to examine the pressure transmission area and maximum pressure transmission of thermoplastic resin denture base materials under an impact load, and to evaluate the modulus of elasticity and nanohardness of thermoplastic resin denture base. METHODS:Three injection-molded ...

    journal_title:Journal of prosthodontic research

    pub_type: 杂志文章

    doi:10.1016/j.jpor.2017.05.001

    authors: Nasution H,Kamonkhantikul K,Arksornnukit M,Takahashi H

    更新日期:2018-01-01 00:00:00

  • The effect of TiO2 and SiO2 nanoparticles on flexural strength of poly (methyl methacrylate) acrylic resins.

    abstract:PURPOSE:TiO(2) and SiO(2) nanoparticles are products of nanotechnology which have been incorporated to acrylic resins (AR) in order to induce antimicrobial properties. However, as additives they can affect the mechanical properties of the final product. The aim of this study was to survey the effects of TiO(2) and SiO(...

    journal_title:Journal of prosthodontic research

    pub_type: 杂志文章

    doi:10.1016/j.jpor.2012.05.001

    authors: Sodagar A,Bahador A,Khalil S,Shahroudi AS,Kassaee MZ

    更新日期:2013-01-01 00:00:00

  • Receptivity of the mandible versus the maxilla to external stimuli in patients with complete dentures.

    abstract:PURPOSE:This study aimed to investigate whether the mandible is more receptive to external stimuli than the maxilla in patients with complete dentures by comparing regional current perception thresholds (CPTs) and pain threshold (PTs). METHODS:A single operator obtained measurements from maxillae at the incisor forame...

    journal_title:Journal of prosthodontic research

    pub_type: 杂志文章

    doi:10.1016/j.jpor.2019.01.001

    authors: Kimoto S,Furuse N,Ogawa T,Nakashima Y,Furokawa S,Okubo M,Yamaguchi H,Kawai Y

    更新日期:2019-07-01 00:00:00

  • Fracture strength testing of crowns made of CAD/CAM composite resins.

    abstract:PURPOSE:The purpose of this study was to ascertain whether computer aided design/computer aided manufacturing (CAD/CAM) composite resin crowns have sufficient strength to withstand the bite force of the molar teeth. The null hypothesis was that the fracture strength of CAD/CAM composite resin crowns is lower than the a...

    journal_title:Journal of prosthodontic research

    pub_type: 杂志文章

    doi:10.1016/j.jpor.2017.10.003

    authors: Okada R,Asakura M,Ando A,Kumano H,Ban S,Kawai T,Takebe J

    更新日期:2018-07-01 00:00:00

  • Marginal and internal fit of three-unit zirconia fixed dental prostheses: Effects of prosthesis design, cement space, and zirconia type.

    abstract:PURPOSE:The purpose of this study was to compare the marginal and internal fit of three-unit fixed dental prostheses (FDPs) fabricated using CAD/CAM with two designs, two cement space (CS), and two zirconia types. METHODS:A master model with two zirconia abutments and a missing tooth was scanned with an intraoral scan...

    journal_title:Journal of prosthodontic research

    pub_type: 杂志文章

    doi:10.1016/j.jpor.2019.12.005

    authors: Suzuki S,Katsuta Y,Ueda K,Watanabe F

    更新日期:2020-10-01 00:00:00

  • DNA amplification using phi29 DNA polymerase validates gene polymorphism analysis from buccal mucosa samples.

    abstract::Venous blood is currently the most common source of DNA for gene polymorphism screening; however, blood sampling is invasive and difficult to perform in general dental treatment. Buccal mucosa samples provide an alternative source of DNA, but it is frequently difficult to effectively amplify the DNA owing to the small...

    journal_title:Journal of prosthodontic research

    pub_type: 杂志文章

    doi:10.1016/j.jpor.2010.12.001

    authors: Taniguchi R,Masaki C,Murashima Y,Makino M,Kojo T,Nakamoto T,Hosokawa R

    更新日期:2011-07-01 00:00:00

  • The impact of a newly constructed removable denture on the objective and subjective masticatory function.

    abstract:PURPOSE:This study investigated the impact of the renewal of a removable prosthesis on the masticatory function by subjective and objective measures and its variation among the types of occlusal support. METHODS:Seventy-eight patients who received newly fabricated removable denture patients participated in this study....

    journal_title:Journal of prosthodontic research

    pub_type: 杂志文章

    doi:10.2186/jpr.JPR_D_20_00045

    authors: Salazar S,Hasegawa Y,Kikuchi S,Kaneda K,Yoneda H,Nokubi T,Hori K,Ono T

    更新日期:2020-10-06 00:00:00

  • Is zirconia a viable alternative to titanium for oral implant? A critical review.

    abstract:PURPOSE:Titanium based implant systems, though considered as the gold standard for rehabilitation of edentulous spaces, have been criticized for many inherent flaws. The onset of hypersensitivity reactions, biocompatibility issues, and an unaesthetic gray hue have raised demands for more aesthetic and tissue compatible...

    journal_title:Journal of prosthodontic research

    pub_type: 杂志文章,meta分析,评审

    doi:10.1016/j.jpor.2017.07.003

    authors: Sivaraman K,Chopra A,Narayan AI,Balakrishnan D

    更新日期:2018-04-01 00:00:00

  • Effect of different investments and mold temperatures on titanium mechanical properties.

    abstract:PURPOSE:The aim of the present study was to evaluate commercially pure titanium (CP Ti) casting quality when a specific to titanium and a conventional phosphate bonded investments were used under different mold temperatures. For this, the evaluated parameters were surface roughness, bending strength, Vickers microhardn...

    journal_title:Journal of prosthodontic research

    pub_type: 杂志文章

    doi:10.1016/j.jpor.2011.01.002

    authors: Rodrigues RC,Almeida EP,Faria AC,Macedo AP,de Mattos Mda G,Ribeiro RF

    更新日期:2012-01-01 00:00:00

  • Clinical and radiographic performance of one-piece and two-piece implant:a systematic review and meta-analysis.

    abstract:PURPOSE:The aim of this system review was to evaluate clinical and radiographic performance of one-piece implant (OPI) and two-piece implant (TPI). METHODS:Electronic database searches were performed in MEDLINE, EMBASE, Cochrane Central Register of Controlled Trials and OpenGrey databases up to May 2019. Two authors i...

    journal_title:Journal of prosthodontic research

    pub_type: 杂志文章

    doi:10.2186/jpr.JPOR_2019_436

    authors: Liu M,He L,Wang H

    更新日期:2020-09-09 00:00:00

  • Effects of different abutment material and surgical insertion torque on the marginal adaptation of an internal conical interface: an in vitro study.

    abstract:PURPOSE:To evaluate the marginal adaptation at implant-abutment connection of an implant featuring a conical (45° taper) internal hexagonal abutment with a connection depth of 2.5mm, comparing the performance of two identical abutments of different material (titanium grade-4 and Co-Cr-alloy). METHODS:Twenty implants (...

    journal_title:Journal of prosthodontic research

    pub_type: 杂志文章

    doi:10.1016/j.jpor.2014.05.004

    authors: Farronato D,Pieroni S,Mangano FG,Briguglio F,Re D

    更新日期:2014-10-01 00:00:00

  • The impact of complete denture making instructional videos on self-directed learning of clinical skills.

    abstract:PURPOSE:The aim of this research was to evaluate the effectiveness of a clinical instructional video with a structured worksheet for independent self-study in a complete denture program. METHODS:47 multilingual dental students completed a task by watching an instructional video with subtitles regarding clinical comple...

    journal_title:Journal of prosthodontic research

    pub_type: 杂志文章

    doi:10.1016/j.jpor.2015.01.004

    authors: Kon H,Botelho MG,Bridges S,Leung KC

    更新日期:2015-04-01 00:00:00

  • Custom ocular prosthesis: comparison of two different techniques.

    abstract:BACKGROUND:Loss of tissue, whether congenital or traumatic or resulting from malignancy or radical surgery, is accompanied by esthetic and psychological effects. Fabrication of an ocular prosthesis is a challenging and time-consuming procedure. PATIENTS AND TECHNIQUES:This article describes two different techniques of...

    journal_title:Journal of prosthodontic research

    pub_type: 杂志文章

    doi:10.1016/j.jpor.2012.08.006

    authors: Prithviraj DR,Gupta V,Muley N,Suresh P

    更新日期:2013-04-01 00:00:00