Abstract:
PURPOSE:Although daytime clenching is believed to be one of the oral parafunctions leading to dental problems, a treatment strategy has not yet been devised. Electromyogram (EMG) biofeedback training was performed to ascertain its effect on the regulation of daytime clenching behavior. MATERIALS AND METHODS:Twenty subjects (mean age, 30.9±5.6 years) who had mild to moderate masticatory muscle pain with daytime clenching behavior were randomly divided into either a biofeedback group (BF) or control group (CO). Subjects were fitted with a hearing-aid-shaped EMG recording and biofeedback apparatus which was used to record EMG data under natural conditions from the temporal muscle, continuously for five hours on four consecutive days. EMG data on Days 1 and 4 were recorded without biofeedback as pre-test and post-test, respectively, and on Days 2 and 3, subjects in the BF group noticed their clenching behaviors via an alert sound from the EMG biofeedback apparatus. No alert sound was given for the CO group throughout the recording sessions. RESULTS:There was no significant difference in the number of clenching events for five hours between the BF group (4.6±2.5) and CO group (4.6±0.9) on Day 1, however a significant decrease was found in the BF group between Day 1 (4.6±2.5) and Day 4 (2.4±1.7; P<0.05). CONCLUSION:Daytime clenching was reduced in the short-term with the help of an EMG biofeedback system under natural circumstances. Further research is needed to confirm a long-lasting effect.
journal_name
J Prosthodont Resjournal_title
Journal of prosthodontic researchauthors
Watanabe A,Kanemura K,Tanabe N,Fujisawa Mdoi
10.1016/j.jpor.2010.09.003subject
Has Abstractpub_date
2011-04-01 00:00:00pages
75-81issue
2eissn
1883-1958issn
2212-4632pii
S1883-1958(10)00113-1journal_volume
55pub_type
杂志文章,随机对照试验abstract:PURPOSE:To perform a comparative analysis of the microstructure, porosity, mechanical properties, corrosion, and tarnish resistance of Co-Cr alloys prepared by casting and three different computer aided designed/computer aided manufacturing (CAD/CAM) techniques. METHODS:Four groups of metallic specimens were prepared,...
journal_title:Journal of prosthodontic research
pub_type: 杂志文章
doi:10.1016/j.jpor.2018.10.008
更新日期:2019-04-01 00:00:00
abstract:PURPOSE:The aim of this in vitro study was to evaluate the three-dimensional trueness and margin quality of monolithic zirconia restorations fabricated by additive 3D gel deposition, compared with those by subtractive milling. METHODS:Ten single crowns and ten 4-unit FPDs of different occlusal geometries and margin th...
journal_title:Journal of prosthodontic research
pub_type: 杂志文章
doi:10.1016/j.jpor.2020.01.002
更新日期:2020-10-01 00:00:00
abstract:PURPOSE:We examined the accuracy, including trueness and precision, of the intraoral scanners comparing with laboratory scanner to reveal the error level of intraoral scanners. METHODS:Measurements were performed using a computer numerical control coordinate measuring machine (CNCCMM) of the reference models as a cont...
journal_title:Journal of prosthodontic research
pub_type: 杂志文章
doi:10.1016/j.jpor.2017.01.005
更新日期:2017-10-01 00:00:00
abstract:PURPOSE:A crown restoration engaged by a clasp as an abutment tooth for a removable partial denture (RPD) occasionally might be removed and eliminated due to secondary caries or apical lesions. However, if the RPD is clinically acceptable without any problems and refabricating the RPD is not recommended, the new crown ...
journal_title:Journal of prosthodontic research
pub_type: 杂志文章
doi:10.1016/j.jpor.2015.01.002
更新日期:2015-04-01 00:00:00
abstract:PURPOSE:Compare the accuracy of intraoral digital impression in full-arch implant-supported fixed dental prosthesis acquired with eight different intraoral scanner (Ios). METHODS:A polymethyl methacrylate acrylic model of an edentulous mandible with six scan-abutment was used as a master model and its dimensions measu...
journal_title:Journal of prosthodontic research
pub_type: 杂志文章
doi:10.1016/j.jpor.2019.04.002
更新日期:2019-10-01 00:00:00
abstract:PURPOSE:Many patients with oromandibular dystonia, which is characterized by involuntary masticatory, lower facial, and/or tongue muscle contractions, experience relief of symptoms through sensory tricks such as eating chewing gum or candy. The aim of this study was to identify the factors influencing the effects of sp...
journal_title:Journal of prosthodontic research
pub_type: 杂志文章
doi:10.1016/j.jpor.2017.09.004
更新日期:2018-04-01 00:00:00
abstract::Tooth replacement in the maxillary anterior region is especially difficult when the loss includes significant amounts of the residual ridge and the soft tissue. Several techniques are available, such as dental implants or fixed partial denture, and bone and gingival grafts or gingival prostheses, respectively. This ar...
journal_title:Journal of prosthodontic research
pub_type: 杂志文章
doi:10.1016/j.jpor.2012.02.003
更新日期:2012-07-01 00:00:00
abstract:PURPOSE:To investigate the effects of using a low-cost powered toothbrush for cleaning on dental prostheses made of heat polymerized poly(methyl methacrylate), PMMA. METHODS:Heat cured PMMA specimens beam with the dimensions of 45.0 mm×6.5 mm×4.5mm were fabricated. The specimens were kept in water storage at 37 °C con...
journal_title:Journal of prosthodontic research
pub_type: 杂志文章
doi:10.1016/j.jpor.2014.06.002
更新日期:2014-10-01 00:00:00
abstract:PURPOSE:Zirconia exhibits excellent strength and high biocompatibility in technological applications and it is has therefore been investigated for clinical applications and research. Before setting prostheses, a crown prosthesis inner surface is sandblasted with alumina to remove contaminants and form small cavities. T...
journal_title:Journal of prosthodontic research
pub_type: 杂志文章
doi:10.1016/j.jpor.2016.02.001
更新日期:2016-10-01 00:00:00
abstract:PURPOSE:Poly(methyl methacrylate) (PMMA) is the most commonly used material in the production of dental prostheses, and its application is often accompanied by the formation of biofilm. The aim of this work was the preparation of a PMMA/gold nanoparticles (AuNps) composite to improve the antimicrobial properties of hea...
journal_title:Journal of prosthodontic research
pub_type: 杂志文章
doi:10.2186/jpr.JPOR_2019_581
更新日期:2020-09-09 00:00:00
abstract:PURPOSE:The number of implants needed to support a maxillary overdenture is still a controversial issue. The aim of this systematic review was to investigate the number of implants required to support a maxillary overdenture in order to obtain optimal treatment outcomes in terms of implant survival, overdenture longevi...
journal_title:Journal of prosthodontic research
pub_type: 杂志文章,meta分析
doi:10.1016/j.jpor.2018.08.006
更新日期:2019-01-01 00:00:00
abstract:PATIENT:Observation of attrition patterns suggests that mandibular movement in sleep bruxism (SB) may be associated with current tooth attrition. The aim of this study was to confirm this phenomenon by investigating mandibular movement and masseter muscle activity. The subject was a healthy 21-year-old Japanese male. W...
journal_title:Journal of prosthodontic research
pub_type: 杂志文章
doi:10.1016/j.jpor.2016.06.003
更新日期:2017-01-01 00:00:00
abstract:PURPOSE:The purpose of this study was to determine the effect of block-out preparation, used to eliminate the undercut area, on the retentive force and stress distribution of resin clasps. METHODS:A total of 72 polyester and polyamide resin clasps were fabricated on a premolar abutment crown following six block-out pr...
journal_title:Journal of prosthodontic research
pub_type: 杂志文章
doi:10.1016/j.jpor.2019.01.002
更新日期:2019-07-01 00:00:00
abstract:PURPOSE:The purpose of this study was to compare the fracture resistance of Co-Cr post-cores fabricated with 3 different techniques: traditional casting (TC), computer-aided design and manufacturing (CAD/CAM) milling (CCM) and direct metal laser sintering (DMLS). METHODS:Forty intact human mandibular premolar were end...
journal_title:Journal of prosthodontic research
pub_type: 杂志文章
doi:10.1016/j.jpor.2015.08.001
更新日期:2016-01-01 00:00:00
abstract:PURPOSE:Although a closed hollow obturator is often applied to post maxillectomy patients, it has a few problems such as complexity of fabrication and water leakage to inside. A one step curing technique to fabricate a closed hollow obturator by constructing a small hollow bulb made by two thermoplastic resin sheets is...
journal_title:Journal of prosthodontic research
pub_type: 杂志文章
doi:10.1016/j.jpor.2013.08.003
更新日期:2013-10-01 00:00:00
abstract:PURPOSE:The purpose of this study was to evaluate the impact of silver nanoparticle incorporation into maxillofacial silicone material on its hardness, tear strength and color stability. METHODS:A total of 180 silicone specimens were fabricated according to the specification of American society for material and testin...
journal_title:Journal of prosthodontic research
pub_type: 杂志文章
doi:10.1016/j.jpor.2019.12.001
更新日期:2020-10-01 00:00:00
abstract:PURPOSE:The aim of this preliminary study is to compare patient-reported outcomes between immediately and conventionally loaded mandibular two-implant overdentures retained by magnetic attachments. METHODS:Nineteen participants with edentulous mandibles were randomly assigned into either an immediate loading group (im...
journal_title:Journal of prosthodontic research
pub_type: 杂志文章
doi:10.1016/j.jpor.2015.12.010
更新日期:2016-07-01 00:00:00
abstract:PURPOSES:The purposes of the present study were to examine the pressure transmission area and maximum pressure transmission of thermoplastic resin denture base materials under an impact load, and to evaluate the modulus of elasticity and nanohardness of thermoplastic resin denture base. METHODS:Three injection-molded ...
journal_title:Journal of prosthodontic research
pub_type: 杂志文章
doi:10.1016/j.jpor.2017.05.001
更新日期:2018-01-01 00:00:00
abstract:PURPOSE:TiO(2) and SiO(2) nanoparticles are products of nanotechnology which have been incorporated to acrylic resins (AR) in order to induce antimicrobial properties. However, as additives they can affect the mechanical properties of the final product. The aim of this study was to survey the effects of TiO(2) and SiO(...
journal_title:Journal of prosthodontic research
pub_type: 杂志文章
doi:10.1016/j.jpor.2012.05.001
更新日期:2013-01-01 00:00:00
abstract:PURPOSE:This study aimed to investigate whether the mandible is more receptive to external stimuli than the maxilla in patients with complete dentures by comparing regional current perception thresholds (CPTs) and pain threshold (PTs). METHODS:A single operator obtained measurements from maxillae at the incisor forame...
journal_title:Journal of prosthodontic research
pub_type: 杂志文章
doi:10.1016/j.jpor.2019.01.001
更新日期:2019-07-01 00:00:00
abstract:PURPOSE:The purpose of this study was to ascertain whether computer aided design/computer aided manufacturing (CAD/CAM) composite resin crowns have sufficient strength to withstand the bite force of the molar teeth. The null hypothesis was that the fracture strength of CAD/CAM composite resin crowns is lower than the a...
journal_title:Journal of prosthodontic research
pub_type: 杂志文章
doi:10.1016/j.jpor.2017.10.003
更新日期:2018-07-01 00:00:00
abstract:PURPOSE:The purpose of this study was to compare the marginal and internal fit of three-unit fixed dental prostheses (FDPs) fabricated using CAD/CAM with two designs, two cement space (CS), and two zirconia types. METHODS:A master model with two zirconia abutments and a missing tooth was scanned with an intraoral scan...
journal_title:Journal of prosthodontic research
pub_type: 杂志文章
doi:10.1016/j.jpor.2019.12.005
更新日期:2020-10-01 00:00:00
abstract::Venous blood is currently the most common source of DNA for gene polymorphism screening; however, blood sampling is invasive and difficult to perform in general dental treatment. Buccal mucosa samples provide an alternative source of DNA, but it is frequently difficult to effectively amplify the DNA owing to the small...
journal_title:Journal of prosthodontic research
pub_type: 杂志文章
doi:10.1016/j.jpor.2010.12.001
更新日期:2011-07-01 00:00:00
abstract:PURPOSE:This study investigated the impact of the renewal of a removable prosthesis on the masticatory function by subjective and objective measures and its variation among the types of occlusal support. METHODS:Seventy-eight patients who received newly fabricated removable denture patients participated in this study....
journal_title:Journal of prosthodontic research
pub_type: 杂志文章
doi:10.2186/jpr.JPR_D_20_00045
更新日期:2020-10-06 00:00:00
abstract:PURPOSE:Titanium based implant systems, though considered as the gold standard for rehabilitation of edentulous spaces, have been criticized for many inherent flaws. The onset of hypersensitivity reactions, biocompatibility issues, and an unaesthetic gray hue have raised demands for more aesthetic and tissue compatible...
journal_title:Journal of prosthodontic research
pub_type: 杂志文章,meta分析,评审
doi:10.1016/j.jpor.2017.07.003
更新日期:2018-04-01 00:00:00
abstract:PURPOSE:The aim of the present study was to evaluate commercially pure titanium (CP Ti) casting quality when a specific to titanium and a conventional phosphate bonded investments were used under different mold temperatures. For this, the evaluated parameters were surface roughness, bending strength, Vickers microhardn...
journal_title:Journal of prosthodontic research
pub_type: 杂志文章
doi:10.1016/j.jpor.2011.01.002
更新日期:2012-01-01 00:00:00
abstract:PURPOSE:The aim of this system review was to evaluate clinical and radiographic performance of one-piece implant (OPI) and two-piece implant (TPI). METHODS:Electronic database searches were performed in MEDLINE, EMBASE, Cochrane Central Register of Controlled Trials and OpenGrey databases up to May 2019. Two authors i...
journal_title:Journal of prosthodontic research
pub_type: 杂志文章
doi:10.2186/jpr.JPOR_2019_436
更新日期:2020-09-09 00:00:00
abstract:PURPOSE:To evaluate the marginal adaptation at implant-abutment connection of an implant featuring a conical (45° taper) internal hexagonal abutment with a connection depth of 2.5mm, comparing the performance of two identical abutments of different material (titanium grade-4 and Co-Cr-alloy). METHODS:Twenty implants (...
journal_title:Journal of prosthodontic research
pub_type: 杂志文章
doi:10.1016/j.jpor.2014.05.004
更新日期:2014-10-01 00:00:00
abstract:PURPOSE:The aim of this research was to evaluate the effectiveness of a clinical instructional video with a structured worksheet for independent self-study in a complete denture program. METHODS:47 multilingual dental students completed a task by watching an instructional video with subtitles regarding clinical comple...
journal_title:Journal of prosthodontic research
pub_type: 杂志文章
doi:10.1016/j.jpor.2015.01.004
更新日期:2015-04-01 00:00:00
abstract:BACKGROUND:Loss of tissue, whether congenital or traumatic or resulting from malignancy or radical surgery, is accompanied by esthetic and psychological effects. Fabrication of an ocular prosthesis is a challenging and time-consuming procedure. PATIENTS AND TECHNIQUES:This article describes two different techniques of...
journal_title:Journal of prosthodontic research
pub_type: 杂志文章
doi:10.1016/j.jpor.2012.08.006
更新日期:2013-04-01 00:00:00