Use of the less invasive stabilization system (LISS) in patients with distal femoral (AO33) fractures: a prospective multicenter study.

Abstract:

INTRODUCTION:The Less Invasive Stabilization System (LISS) is an internal fixator that can be inserted percutaneously by means of a minimally invasive surgical approach. This paper presents the use of this system exclusively in patients with AO33 distal femoral fractures, a group in which fracture management is often complicated by multiple trauma and soft-tissue damage. MATERIALS AND METHODS:A series of 62 patients (mean age 52 years) with 66 AO33A or C fractures received the LISS implant and were followed prospectively for 12 months. Assessments included the radiographic evaluation of implant placement and healing, measurement of valgus/varus and sagittal joint malalignment, and the assessment of weight-bearing capacity and range of motion. RESULTS:The mean duration of surgery was 85 min (range 40-135 min) for 33A fractures and 149 min (range 50-300 min) for 33C fractures. Postoperative radiographic assessments showed that the LISS implant was positioned correctly in 59 cases (89%). Assessment of valgus/varus alignment showed correct axial alignment in 49 cases (74%), a deviation of 5-10 degrees in 13 cases, and a 10-20 degrees deviation in 1 case. Correct sagittal alignment was observed in 56 cases (85%), 5-10 degrees malalignment in 5 cases, and 10-20 degrees in 2 cases. During the course of the 1-year follow-up, 8 patients (9 fractures) died; 2 other patients were not available for follow-up. Complete fracture healing was achieved in 85% of the followed-up patients. Forty-eight patients were capable of full weight-bearing. After fracture healing, maximum flexion of the injured limb was on average 80% of the range of the uninjured limb. An extension deficit of more than 5 degrees was measured in 3 cases. Of the 62 patients, 14 underwent further operations during the course of follow-up. Of these, 6 required bone grafting and 3 refixation of the implant due to implant loosening. Deep infections requiring several debridements occurred in 2 patients. No complications relating solely to the implant were observed. CONCLUSION:The LISS showed good overall results in the treatment of these difficult fractures. It is a good alternative to conventional extramedullary and intramedullary stabilizing techniques, especially in more complex fracture situations.

authors

Schütz M,Müller M,Regazzoni P,Höntzsch D,Krettek C,Van der Werken C,Haas N

doi

10.1007/s00402-004-0779-x

subject

Has Abstract

pub_date

2005-03-01 00:00:00

pages

102-8

issue

2

eissn

0936-8051

issn

1434-3916

journal_volume

125

pub_type

临床试验,杂志文章,多中心研究
  • Low-profile double plating versus dorsal LCP in stabilization of the olecranon fractures.

    abstract:INTRODUCTION:Proximal ulna fractures are common in orthopaedic surgery. Comminuted fractures require a high primary stability by the osteosynthesis, to allow an early functional rehabilitation as fast as possible, to reduce long-term limitations of range of motion. Classical dorsal plating is related to wound healing p...

    journal_title:Archives of orthopaedic and trauma surgery

    pub_type: 杂志文章

    doi:10.1007/s00402-020-03473-9

    authors: Hoelscher-Doht S,Kladny AM,Paul MM,Eden L,Buesse M,Meffert RH

    更新日期:2020-05-16 00:00:00

  • A case of old trapezoid fracture.

    abstract::We studied a rare case of old dorsal displacement fracture of the trapezoid. Favorable results were obtained with sugical reduction, despite the fracture being old. ...

    journal_title:Archives of orthopaedic and trauma surgery

    pub_type: 杂志文章

    doi:10.1007/s004020050427

    authors: Watanabe H,Hamada Y,Yamamoto Y

    更新日期:1999-01-01 00:00:00

  • Clinical and user-friendly classification of traumatic digital nerve injuries of hand.

    abstract:INTRODUCTION:Surgical findings of traumatic neurapraxia and neurotmesis in digital nerve injuries of hand have significantly different prognosis and surgeons managing such injuries must be able to provide the expected incidence of these injuries along with decision on surgical exploration. There is a paucity of data in...

    journal_title:Archives of orthopaedic and trauma surgery

    pub_type: 杂志文章

    doi:10.1007/s00402-007-0299-6

    authors: Kumar S,Hassouna H,Penematsa S

    更新日期:2007-09-01 00:00:00

  • Autogenous iliac crest bone grafting for tibial nonunions revisited: does approach matter?

    abstract:BACKGROUND:Tibial nonunion remains a considerable burden for patients and the surgeons who treat them. In recent years, alternatives to autogenous grafts for the treatment of tibial nonunions have been sought. The purpose of this study was to evaluate the efficacy of autogenous iliac crest bone graft (ICBG) in the trea...

    journal_title:Archives of orthopaedic and trauma surgery

    pub_type: 杂志文章

    doi:10.1007/s00402-020-03735-6

    authors: Konda SR,Littlefield CP,Carlock KD,Ganta A,Leucht P,Egol KA

    更新日期:2021-01-08 00:00:00

  • Evaluation of biomechanical properties: are porcine flexor tendons and bovine extensor tendons eligible surrogates for human tendons in in vitro studies?

    abstract:INTRODUCTION:Porcine flexor tendons, bovine extensor tendons, and human (semitendinosus) tendons are frequently used as substitutes for human ACL grafts in biomechanical in vitro studies. This study compares the biomechanical properties and structural differences of these tendons. MATERIALS AND METHODS:In this biomech...

    journal_title:Archives of orthopaedic and trauma surgery

    pub_type: 杂志文章

    doi:10.1007/s00402-016-2529-2

    authors: Domnick C,Wieskötter B,Raschke MJ,Schulze M,Kronenberg D,Wefelmeier M,Langer MF,Herbort M

    更新日期:2016-10-01 00:00:00

  • Sternoclavicular joint septic arthritis and mediastinitis. A case report and review of the literature.

    abstract::Septic arthritis of the sternoclavicular joint is rare. Its causes have been reported to include immuno-compromizing diseases, intravenous drug abuse, fractures of the clavicle or catheterization of the subclavian vein. We report a case of septic arthritis of the SCJ in a diabetic patient following periarticular injec...

    journal_title:Archives of orthopaedic and trauma surgery

    pub_type: 杂志文章,评审

    doi:10.1007/s00402-006-0273-8

    authors: Mikroulis DA,Verettas DA,Xarchas KC,Lawal LA,Kazakos KJ,Bougioukas GJ

    更新日期:2008-02-01 00:00:00

  • Practicability of a locking plate for difficult pathologies of the scaphoid.

    abstract:INTRODUCTION:Headless compressions screws are the most implanted devices for scaphoid fractures and nonunions. For cases when screw osteosynthesis is not possible, a special locking plate for scaphoid reconstruction has been developed. The purpose of this study was to evaluate the safety and practicability of this devi...

    journal_title:Archives of orthopaedic and trauma surgery

    pub_type: 杂志文章

    doi:10.1007/s00402-019-03196-6

    authors: Mehling IM,Arsalan-Werner A,Wingenbach V,Seegmüller J,Schlageter M,Sauerbier M

    更新日期:2019-08-01 00:00:00

  • High incidence of tunnel widening after anterior cruciate ligament reconstruction with transtibial femoral tunnel placement.

    abstract:BACKGROUND:This study evaluated the incidence, amount, morphology and clinical significance of bone tunnel widening (TW) at a mean 5-year period after anterior cruciate ligament reconstruction (ACLR) with a transtibial drilling technique. METHODS:Fifty-nine patients undergoing primary ACLR using quadrupled hamstring a...

    journal_title:Archives of orthopaedic and trauma surgery

    pub_type: 杂志文章

    doi:10.1007/s00402-012-1596-2

    authors: Nebelung S,Deitmer G,Gebing R,Reichwein F,Nebelung W

    更新日期:2012-11-01 00:00:00

  • Inter- and intraobserver reliability of non-weight-bearing foot radiographs compared with CT in Lisfranc injuries.

    abstract:BACKGROUND:Injury of the tarsometatarsal (TMT) joint complex, known as Lisfranc injury, covers a wide range of injuries from subtle ligamentous injuries to severely displaced crush injuries. Although it is known that these injuries are commonly missed, the literature on the accuracy of the diagnostics is limited. The d...

    journal_title:Archives of orthopaedic and trauma surgery

    pub_type: 杂志文章

    doi:10.1007/s00402-020-03391-w

    authors: Ponkilainen VT,Partio N,Salonen EE,Riuttanen A,Luoma EL,Kask G,Laine HJ,Mäenpää H,Päiväniemi O,Mattila VM,Haapasalo HH

    更新日期:2020-10-01 00:00:00

  • Initial promising results of the dynamic locking blade plate, a new implant for the fixation of intracapsular hip fractures: results of a pilot study.

    abstract:INTRODUCTION:The osteosynthesis of intracapsular hip fractures results in a 19-48% failure rate. Only when the anatomical reduction is secured by stable fixation, revascularisation of the femoral head can take place and the fracture can heal by primary osteonal reconstruction. The common implants lack rotational and/or...

    journal_title:Archives of orthopaedic and trauma surgery

    pub_type: 杂志文章

    doi:10.1007/s00402-010-1195-z

    authors: Roerdink WH,Aalsma AM,Nijenbanning G,van Walsum AD

    更新日期:2011-04-01 00:00:00

  • Tibia valga after fracture: documentation of mechanism.

    abstract::Tibia valga following fracture in the proximal metaphysis of the tibia in children was previously attributed to various mechanisms. This case report offers an additional explanation based on bone scintigraphy 10 months after injury. Decreased radionuclide uptake at the lateral proximal tibial physis without evidence o...

    journal_title:Archives of orthopaedic and trauma surgery

    pub_type: 杂志文章

    doi:10.1007/BF00571065

    authors: Keret D,Harcke HT,Bowen JR

    更新日期:1991-01-01 00:00:00

  • Lumbar spine stability after combined application of interspinous fastener and modified posterior lumbar interbody fusion: a biomechanical study.

    abstract:INTRODUCTION:Posterior lumbar interbody fusion (PLIF) and internal fixation are commonly performed for the treatment of lower back pain due to lumbar spinal degeneration. We have developed a novel interspinous fixation device, the interspinous fastener (ISF) for potential use in the surgical management of degenerative ...

    journal_title:Archives of orthopaedic and trauma surgery

    pub_type: 杂志文章

    doi:10.1007/s00402-014-1977-9

    authors: Yu X,Zhu L,Su Q

    更新日期:2014-05-01 00:00:00

  • Use of arthroscopy and interporous hydroxyapatite as a bone graft substitute in tibial plateau fractures.

    abstract::Tibial plateau fractures in 17 patients were managed arthroscopically, using interporous hydroxypatite (HA) as a bone graft substitute. Soft-tissue repair and intra-articular lavages were carried out arthroscopically, and depression of the articular surface was done by elevation of the subchondral plate by the bone co...

    journal_title:Archives of orthopaedic and trauma surgery

    pub_type: 杂志文章

    doi:10.1007/BF00453217

    authors: Itokazu M,Matsunaga T,Ishii M,Kusakabe H,Wyni Y

    更新日期:1996-01-01 00:00:00

  • Effect of continuous versus dichotomous outcome variables on study power when sample sizes of orthopaedic randomized trials are small.

    abstract::It is often not feasible to conduct large trials in orthopaedic surgery. Therefore, surgeons must identify strategies to optimize the statistical power of their smaller studies. The aim of this study was to compare study power in randomized trials with continuous versus dichotomous outcome variables. We performed a sy...

    journal_title:Archives of orthopaedic and trauma surgery

    pub_type: 杂志文章

    doi:10.1007/s004020100347

    authors: Bhandari M,Lochner H,Tornetta P 3rd

    更新日期:2002-03-01 00:00:00

  • A lateral retinacular release during total knee arthroplasty changes femorotibial kinematics: an in vitro study.

    abstract:INTRODUCTION:Lateral retinacular release (LRR) is a common procedure during total knee arthroplasty (TKA), especially if patellar maltracking is observed intraoperatively. The impact of LRR on patellofemoral kinematics is well-examined, but the influence on femorotibial kinematics requires more elucidation. Therefore, ...

    journal_title:Archives of orthopaedic and trauma surgery

    pub_type: 杂志文章

    doi:10.1007/s00402-017-2843-3

    authors: Steinbrück A,Schröder C,Woiczinski M,Glogaza A,Müller PE,Jansson V,Fottner A

    更新日期:2018-03-01 00:00:00

  • Stability of supramalleolar osteotomies using different implants in a sawbone model.

    abstract:BACKGROUND:With ankle arthritis often affecting young patients, joint-sparing treatments instead of total joint replacement should be considered. Only a few implants were specially developed for supramalleolar osteotomies (SMOT). This study was performed to analyse the stability of different implants and their appropri...

    journal_title:Archives of orthopaedic and trauma surgery

    pub_type: 杂志文章

    doi:10.1007/s00402-018-2981-2

    authors: Ettinger S,Schwarze M,Yao D,Ettinger M,Claassen L,Stukenborg-Colsman C,Thermann H,Plaass C

    更新日期:2018-10-01 00:00:00

  • Reconstruction techniques in comparison for reverse shoulder trauma prosthesis in the elderly: a follow-up between 2 and 4 years.

    abstract:INTRODUCTION:The aim of this study was to evaluate the clinical outcome of a bone graft technique called bCAT (bone Collar And Tie), in which the fractured humeral head is modelled into a collar shape versus puzzle piece reconstruction (PPR) in elderly patients with complex proximal humeral fractures. MATERIALS AND ME...

    journal_title:Archives of orthopaedic and trauma surgery

    pub_type: 杂志文章

    doi:10.1007/s00402-015-2221-y

    authors: Russo R,Cautiero F,Fontanarosa A,della Rotonda G,Valerio G

    更新日期:2015-07-01 00:00:00

  • Evaluation of radiological instability signs in the distal radioulnar joint in children and adolescents with arthroscopically-verified TFCC tears.

    abstract:INTRODUCTION:Recent reports in the adult literature reported the use of standardized radiographic measurement techniques to determine distal radioulnar joint (DRUJ) instability. The aim of this study was to evaluate the efficacy and accuracy of (1) the MRI-based modified radioulnar ratio technique and (2) the pisoscaph...

    journal_title:Archives of orthopaedic and trauma surgery

    pub_type: 杂志文章

    doi:10.1007/s00402-020-03470-y

    authors: Schachinger F,Wiener S,Carvalho MF,Weber M,Ganger R,Farr S

    更新日期:2020-07-01 00:00:00

  • Early detection of avascular necrosis of the femoral head following renal transplantation.

    abstract::This prospective study included 43 patients undergoing renal transplantations. Magnetic resonance imaging (MRI) and X-rays of the hip joints were produced 3 and 12 months after transplantation. In 6 hip joints of 4 patients (9.3%), we discovered femoral head necroses just 3 months after transplantation. Three of the h...

    journal_title:Archives of orthopaedic and trauma surgery

    pub_type: 临床试验,杂志文章

    doi:10.1007/BF00426064

    authors: Fink B,Degenhardt S,Paselk C,Schneider T,Mödder U,Rüther W

    更新日期:1997-01-01 00:00:00

  • Dislocation of the shoulder joint with ipsilateral humeral shaft fracture: two case reports.

    abstract:INTRODUCTION:A combination of the shaft fracture of the humerus with shoulder dislocation is a rarely documented injury. Moreover, few reports describe a long-term outcome after a follow-up period over 10 years. The present article is the first report of long-term clinical results obtained with this combined injury. M...

    journal_title:Archives of orthopaedic and trauma surgery

    pub_type: 杂志文章

    doi:10.1007/s00402-005-0090-5

    authors: Sasashige Y,Kurata T,Masuda Y,Shimono K,Nagata Y

    更新日期:2006-10-01 00:00:00

  • Tissue response to bioabsorbable self-reinforced polylevolactide and polyglycolide pins implanted intra-articularly and directly into the bone on different levels. An experimental study on rats.

    abstract::Self-reinforced poly-L-lactide (SR-PLLA) and self-reinforced polyglycolide (SR-PGA) pins were implanted intra-articularly and directly into the bone of the distal femur of rats at three levels: above, on the same level, and under the surface. For the controls only channels were drilled, or the controls were not operat...

    journal_title:Archives of orthopaedic and trauma surgery

    pub_type: 杂志文章

    doi:10.1007/s004020050336

    authors: Koskikare K,Toivonen T,Rokkanen P

    更新日期:1998-01-01 00:00:00

  • Complications of implant removal after healed hip fractures.

    abstract:INTRODUCTION:Osteosynthesis of pertrochanteric fractures is one of the most frequently performed procedures in orthopaedic trauma care. Auto-dynamization during fracture healing can lead to lateralization of the screw or blade. This can cause debilitating complaints, which sometimes necessitate the removal of the screw...

    journal_title:Archives of orthopaedic and trauma surgery

    pub_type: 杂志文章

    doi:10.1007/s00402-020-03435-1

    authors: Driessen MLS,Goessens MLMJ

    更新日期:2020-11-01 00:00:00

  • Weight-bearing restrictions reduce postoperative mobility in elderly hip fracture patients.

    abstract:BACKGROUND AND PURPOSE:Reduced mobility is a severe threat to the clinical outcomes and survival of elderly hip fracture patients. These patients generally struggle to comply with partial weight bearing, yet postoperative weight-bearing restrictions are still recommended by nearly 25% of surgeons. Therefore, we hypothe...

    journal_title:Archives of orthopaedic and trauma surgery

    pub_type: 杂志文章

    doi:10.1007/s00402-019-03193-9

    authors: Pfeufer D,Zeller A,Mehaffey S,Böcker W,Kammerlander C,Neuerburg C

    更新日期:2019-09-01 00:00:00

  • Selective thigh muscle atrophy in trans-tibial amputees: an ultrasonographic study.

    abstract::In trans-tibial amputees, PTB (patellar tendon bearing) prostheses provide almost physiological mobility of the knee joint in the sagittal plane. Nevertheless, there are characteristic adaptations of the knee joint muscles. Myosonography is a suitable method for depicting muscle atrophy and hypertrophy due to muscle d...

    journal_title:Archives of orthopaedic and trauma surgery

    pub_type: 杂志文章

    doi:10.1007/s004020000227

    authors: Schmalz T,Blumentritt S,Reimers CD

    更新日期:2001-06-01 00:00:00

  • Metal-on-metal hip resurfacing: a critical review.

    abstract::In this article, a concise review of the current literature on metal-on-metal hip resurfacing (MoMHR) is given. In contrast to conventional total hip arthroplasty, older age, female sex and small femoral head sizes predispose to failure. Neck fracture and metal wear-related complications account for the most frequent ...

    journal_title:Archives of orthopaedic and trauma surgery

    pub_type: 杂志文章,评审

    doi:10.1007/s00402-010-1153-9

    authors: Macpherson GJ,Breusch SJ

    更新日期:2011-01-01 00:00:00

  • Static progressive versus dynamic splinting for posttraumatic elbow stiffness: a systematic review of 232 patients.

    abstract:INTRODUCTION:The elbow is prone to stiffness after trauma. To regain functional elbow motion, several conservative and surgical treatment options are available. Nonoperative treatment includes physical therapy, intra-articular injections with corticosteroids, and a static progressive or dynamic splinting program. The o...

    journal_title:Archives of orthopaedic and trauma surgery

    pub_type: 杂志文章,评审

    doi:10.1007/s00402-015-2199-5

    authors: Veltman ES,Doornberg JN,Eygendaal D,van den Bekerom MP

    更新日期:2015-05-01 00:00:00

  • Orthopaedic residents' autonomy in hip fracture surgery: what is the effect on patient outcomes?

    abstract:BACKGROUND:In the context of growing prevalence of hip fractures and hip fracture surgery in the elderly, it is unknown if surgical trainee autonomy in the operating room conflicts with optimal health care provision and safety of patients. We hypothesized that surgery performed solely by residents, without supervision ...

    journal_title:Archives of orthopaedic and trauma surgery

    pub_type: 杂志文章

    doi:10.1007/s00402-020-03734-7

    authors: Prat D,Maoz O,Myerson CL,Zabtani A,Afek A,Tenenbaum S

    更新日期:2021-01-23 00:00:00

  • Compound osteosynthesis of pathological fractures of the proximal femoral shaft. Experimental studies on the biomechanical effects of additional intramedullary splinting.

    abstract::The biomechanical stability of two compound osteosynthesis techniques with and without intramedullary splinting were compared in 20 paired cadaver femora. Group A was stabilised using a contoured 12-hole DC plate and polymethylmethacrylate cement. In group B an additional intramedullary semi-diameter osteosynthesis pl...

    journal_title:Archives of orthopaedic and trauma surgery

    pub_type: 杂志文章

    doi:10.1007/BF00573454

    authors: Heller KD,Zilkens KW,Cohen B,Hammer J

    更新日期:1996-01-01 00:00:00

  • Salvage of proximal tibial malunion or nonunion with the use of angled blade plate.

    abstract:INTRODUCTION:Single buttress plating laterally was sometimes performed by a few orthopedists to treat complex tibial plateau fractures with medial compartment involvement. However, we might encounter cases with medial compartment collapse due to such treatment. The causes of failure, the technique of the revision surge...

    journal_title:Archives of orthopaedic and trauma surgery

    pub_type: 杂志文章

    doi:10.1007/s00402-006-0106-9

    authors: Wu CC

    更新日期:2006-03-01 00:00:00

  • Disseminated hydatid disease causing paraplegia and destruction of the hip.

    abstract::A patient who had had been treated by surgery for spinal echinococcosis in a Mediterranean country emigrated to northern Europe. After surgery, the echinococcosis disseminated and he developed chronic lytic and sinus-draining hydatid disease of the left hip and neuromuscular weakness of the left lower extremity. Seven...

    journal_title:Archives of orthopaedic and trauma surgery

    pub_type: 杂志文章

    doi:10.1007/pl00021231

    authors: Santavirta S,Valtonen M,Pätiälä H,Saarinen O,Konttinen YT

    更新日期:2000-01-01 00:00:00