Abstract:
INTRODUCTION:The critical question for technological advancement of catheter ablation of atrial fibrillation (AF) is whether a creative new concept can combine and even improve the options of single-tip catheters with the simplicity of the use of balloon catheters. Herein are described the results from the first clinical study of a new multielectrode contact-mapping plus ablation array (Globe) offering such a complete solution. METHODS AND RESULTS:The multielectrode Globe array consists of 16 flat ribs with 122 gold-plated electrodes. Each electrode can record electrograms, ablate, pace, and can measure tissue contact and temperature. Single-shot pulmonary vein isolation (PVI) is possible with temperature-guided ablation of up to 24 electrodes simultaneously with automatic, individual power control of every electrode. Sixty patients with symptomatic AF underwent PVI using the Globe. In all sixty patients, acute PVI was achieved in 232 of 234 attempted PVs (99.1%). In 34 patients treated with "single-hot-shot" ablation, PVI was achieved in 136 of 136 PVs (100%). Single-procedure 12-month freedom from AF off antiarrhythmic drugs in the "single-hot-shot" group was 75.5% and freedom from AF/atrial tachycardia 72.3%. In two patients, pericardial tamponade was observed, one after a transseptal puncture, and one during array insertion with an over-advanced sheath. There were no other device-related serious adverse events, including stroke, PV stenosis, esophageal perforation, or phrenic nerve palsy. CONCLUSIONS:In this first clinical series, the Globe catheter was found to be an easy-to-use system for single-shot PVI. The continuously updated multielectrode voltage and activation mapping data indicate future options for mapping and ablation beyond PVI.
journal_name
J Cardiovasc Electrophysioljournal_title
Journal of cardiovascular electrophysiologyauthors
Kottkamp H,Hindricks G,Pönisch C,Bertagnolli L,Moser F,Hilbert S,Rieger A,Sommer Pdoi
10.1111/jce.14172subject
Has Abstractpub_date
2019-11-01 00:00:00pages
2248-2255issue
11eissn
1045-3873issn
1540-8167journal_volume
30pub_type
杂志文章abstract:INTRODUCTION:ATP-sensitive K+ channels (K(ATP)) are expressed abundantly in cardiovascular tissues. Blocking this channel in experimental models of ischemia can reduce arrhythmias. We investigated the acute effects of amiodarone on the activity of cardiac sarcolemmal K(ATP) channels and their sensitivity to ATP. METHO...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 杂志文章
doi:10.1111/j.1540-8167.2000.tb01762.x
更新日期:2000-10-01 00:00:00
abstract:INTRODUCTION:Both isoproterenol (Iso) and adenosine (Ado) are used to induce atrial fibrillation (AF) in the electrophysiology lab. However, the utility of Ado has not been systematically established. OBJECTIVE:The purpose of this study was to compare Ado to Iso for the induction of paroxysmal AF. METHODS:Forty patie...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 杂志文章,随机对照试验
doi:10.1111/jce.13779
更新日期:2019-02-01 00:00:00
abstract:INTRODUCTION:Deaths secondary to low-energy impacts to the precordium in young individuals (commotio cordis) have been reported with increasing frequency. In a swine model, baseball impacts induce ventricular fibrillation when directed at the center of the left ventricle during the vulnerable portion of repolarization ...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 杂志文章
doi:10.1046/j.1540-8167.2005.40664.x
更新日期:2005-04-01 00:00:00
abstract:BACKGROUND:Neurally mediated syncope (NMS) is a common disorder that is triggered by orthostatic stress. The circulatory adjustments to orthostatic stress occur just prior to a sudden loss of consciousness. NMS prediction would protect patients from falls or accidents. METHODS AND RESULTS:Based on simultaneously recor...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 杂志文章
doi:10.1111/j.1540-8167.2011.02030.x
更新日期:2011-09-01 00:00:00
abstract:INTRODUCTION:The application of high-frequency current to the AV junctional area results in a temperature rise in the myocardium and may cause accelerated junctional rhythm (AJR). The aim of the study was to characterize heat-induced AJR in an in vitro animal model. METHODS AND RESULTS:Studies were performed in isolat...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 杂志文章
doi:10.1111/j.1540-8167.1998.tb00946.x
更新日期:1998-06-01 00:00:00
abstract::Three patients in whom Class IC sodium channel blockers induced ST segment elevation in leads V1 through V3 are described. The underlying electrophysiologic mechanism, implications for drug-induced proarrhythmia, and the relationship of the finding to the Brugada syndrome type of idiopathic ventricular fibrillation ar...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 杂志文章
doi:10.1111/j.1540-8167.1998.tb00088.x
更新日期:1998-11-01 00:00:00
abstract:BACKGROUND:Esophageal injury during left atrial ablation is associated with a significant risk of mortality and morbidity. There are no validated approaches to reduce injury outside of avoidance, a strategy critically dependent on a precise understanding of the esophageal anatomy and location. Intracardiac ultrasound (...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 杂志文章
doi:10.1111/j.1540-8167.2012.02441.x
更新日期:2013-01-01 00:00:00
abstract:INTRODUCTION:Lead dysfunction can lead to serious consequences including failure to treat ventricular tachycardia or fibrillation (VT/VF). The incidence and mechanisms of lead dysfunction following left ventricular assist device (LVAD) implantation are not well-described. We sought to determine the incidence, mechanism...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 杂志文章
doi:10.1111/jce.14487
更新日期:2020-06-01 00:00:00
abstract:BACKGROUND:Symptom recurrence following sinus node modification (SNM) for inappropriate sinus tachycardia (IST) remains significant despite achieving acute procedural success. The impact of non-IST tachyarrhythmias on symptom recurrence remains poorly characterized. OBJECTIVES:The objective was to determine the preval...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 杂志文章
doi:10.1111/j.1540-8167.2012.02297.x
更新日期:2012-08-01 00:00:00
abstract:INTRODUCTION:Anatomic and electrical connections between the left atrium and right atrium (RA) have been described. The relationship between coronary sinus (CS) pacing site and RA activation has not been examined. METHODS AND RESULTS:Fifteen anesthetized swine underwent high-density noncontact mapping of the RA during...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 杂志文章
doi:10.1046/j.1540-8167.2002.00794.x
更新日期:2002-08-01 00:00:00
abstract::A novel application of the Biosense CARTO System anatomic electromagnetic voltage mapping is presented, utilized as a guide for permanent pacemaker placement. The technique is illustrated in the successful implantation of an atrial lead in a patient with Ebstein's anomaly characterized by a severely dilated right atri...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 杂志文章
doi:10.1111/j.1540-8167.2000.tb00744.x
更新日期:2000-01-01 00:00:00
abstract:INTRODUCTION:The right inferior pulmonary vein (RIPV) accounts as the most frequently reconnected vein after pulmonary vein isolation using second-generation cryoballoon ablation (CB-A). Our objective was to assess anatomic predictors of late RIPV reconnection based on preprocedural computed tomography scan. METHODS:P...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 杂志文章
doi:10.1111/jce.14186
更新日期:2019-11-01 00:00:00
abstract:INTRODUCTION:Little data exists on the electrophysiological differences between sustained atrial fibrillation (sAF; >5 minutes) vs self-terminating nonsustained AF (nsAF; <5 minutes). We sought to investigate the electrophysiological characteristics of coronary sinus (CS) activity during postpulmonary vein isolation (P...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 杂志文章
doi:10.1111/jce.14296
更新日期:2020-01-01 00:00:00
abstract:INTRODUCTION:We conducted this study to examine the effect of the ICD on the outcomes of patients with prior coronary revascularization enrolled in the Sudden Cardiac Death in Heart Failure Trial (SCD-HeFT) and to assess the association of time from coronary revascularization to enrollment with death and sudden cardiac...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 杂志文章
doi:10.1111/j.1540-8167.2008.01191.x
更新日期:2008-10-01 00:00:00
abstract:INTRODUCTION:Cerebral embolism and stroke are feared complications of left atrial catheter ablation such as pulmonary vein (PV) ablation. In order to assess the thrombogenicity of left atrial catheter ablation, knowledge of both clinically evident as well as silent cerebral embolism is important. The aim of the current...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 杂志文章
doi:10.1111/j.1540-8167.2005.00279.x
更新日期:2006-01-01 00:00:00
abstract::We describe the case of 2-year-old baby with compound heterozygosity for paternal and maternal alleles mutation of α-subunit of the cardiac sodium channel (SCN5A), sinus node dysfunction, atrial flutter recurrences, and drug induced long-QT syndrome. In this setting, we chose at first to perform linear ablation of cav...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 杂志文章
doi:10.1111/jce.12570
更新日期:2015-03-01 00:00:00
abstract:INTRODUCTION:In vitro studies and ambulatory ECG recordings from the MERLIN TIMI-36 clinical trial suggest that the novel antianginal agent ranolazine may have the potential to suppress atrial arrhythmias. However, there are no reports of effects of ranolazine on atrial electrophysiologic properties in large intact ani...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 杂志文章
doi:10.1111/j.1540-8167.2009.01437.x
更新日期:2009-07-01 00:00:00
abstract:INTRODUCTION:Complex fractionated atrial electrograms (CFAEs) are a substrate modification target in patients with atrial fibrillation (AF). However, whether CFAEs can be also arrhythmogenic grounds of atrial tachycardia (AT) presenting after AF ablation remains to be determined. We investigated the relationship betwee...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 临床试验,杂志文章
doi:10.1111/jce.12300
更新日期:2014-02-01 00:00:00
abstract:BACKGROUND:Reentry utilizing cavotricuspid isthmus (CTI) is accepted as the mechanism underlying typical atrial flutter (AFLT). However, it is unclear how the right atrial (RA) posterior wall (PW) participates in AFLT circuit. We sought to investigate this by using noncontact electroanatomic mapping. METHODS:Fifteen p...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 杂志文章
doi:10.1111/j.1540-8167.2010.01917.x
更新日期:2011-04-01 00:00:00
abstract:INTRODUCTION:accurate selection of patients for vasovagal syncope studies requires strong risk stratification and knowledge of the natural history of syncope. We aimed to test the hypothesis that recent history of vasovagal syncope compared to distant history better predicts subsequent recurrence of syncope. METHODS A...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 杂志文章,随机对照试验
doi:10.1111/j.1540-8167.2010.01848.x
更新日期:2010-12-01 00:00:00
abstract::Phrenic nerve stimulation (PNS) caused by a right ventricular (RV) lead is an uncommon complication of pacemaker implantations. We demonstrated a case of left PNS caused by an RV lead placed in the RV outflow tract (RVOT). The PNS was dependent on ventricular capture. This case highlighted a risk of PNS even during RV...
journal_title:Journal of cardiovascular electrophysiology
pub_type:
doi:10.1111/jce.14760
更新日期:2020-12-01 00:00:00
abstract::Ischemic preconditioning is a phenomenon whereby exposure of the myocardium to a brief episode of ischemia and reperfusion markedly reduces tissue necrosis induced by a subsequent prolonged ischemia. Therefore, it is hoped that elucidation of the mechanism of preconditioning will yield therapeutic strategies capable o...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 杂志文章,评审
doi:10.1111/j.1540-8167.1999.tb00251.x
更新日期:1999-05-01 00:00:00
abstract:INTRODUCTION:EnSite NavX (NavX) is a novel mapping and navigation system that allows visualization of conventional catheters for diagnostic and ablative purposes and uses them to create a three-dimensional (3D) geometry of the heart. NavX is particularly suitable for ablation procedures utilizing an anatomic approach, ...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 临床试验,杂志文章,随机对照试验
doi:10.1046/j.1540-8167.2004.04064.x
更新日期:2004-10-01 00:00:00
abstract::We describe a case of symptomatic pseudo-AV block due to His-bundle parasystole masquerading as exercise-induced 2:1 AV block. Electrophysiologic study revealed the presence of His-bundle parasystole, and the fluctuation of parasystolic cycle length could be explained by the concept of modulated parasystole. Modulated...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 杂志文章
doi:10.1046/j.1540-8167.2001.00965.x
更新日期:2001-08-01 00:00:00
abstract:INTRODUCTION:It has been speculated that pacemaker current (I(f)) in human atria could play a role in causing ectopic atrial automaticity. Ivabradine is a novel selective and specific I(f) inhibitor in the sinus node that reduces heart rate without any negative inotropic effect. The aim of the study was to explore poss...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 杂志文章
doi:10.1111/j.1540-8167.2007.00955.x
更新日期:2007-11-01 00:00:00
abstract:INTRODUCTION:Isoproterenol is used to assess and facilitate AV nodal conduction, and thus potentiate the induction of supraventricular arrhythmias. It is commonly administered in increasing doses until a predetermined decrease in sinus cycle length, usually 20% to 30%, occurs. This regimen may result in undesirable sid...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 杂志文章
doi:10.1111/j.1540-8167.1997.tb00845.x
更新日期:1997-08-01 00:00:00
abstract:INTRODUCTION:Accurate analysis of the arrhythmia substrate is important for successful radiofrequency ablation of sustained ventricular tachycardia (VT) after myocardial infarction (MI). METHODS AND RESULTS:A multielectrode "basket" catheter capable of endocardial recording and pacing was inserted percutaneously into ...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 杂志文章
doi:10.1111/j.1540-8167.1999.tb00209.x
更新日期:1999-11-01 00:00:00
abstract:BACKGROUND:The vein of Marshall (VOM), which exists along the left lateral isthmus (LLI), constitutes a muscular connection between the coronary sinus (CS) and the left atrium (LA). We hypothesized that anatomical variation of the VOM affects the bidirectional block of LLI and the clinical outcome in patients with nonp...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 杂志文章
doi:10.1111/j.1540-8167.2008.01408.x
更新日期:2009-06-01 00:00:00
abstract:INTRODUCTION:It is the hypothesis of this article that the onset of fibrillation following a coronary artery occlusion is a direct consequence of the spatial inhomogeneity of chemical processes that occur following the occlusion. In particular, the localized increase of extracellular potassium and decrease of ATP avail...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 杂志文章
doi:10.1046/j.1540-8167.2003.03045.x
更新日期:2003-11-01 00:00:00
abstract:BACKGROUND:Ventricular desynchronization caused by right ventricular pacing may impair ventricular function and increase risk of heart failure (CHF), atrial fibrillation (AF), and death. Conventional DDD/R mode often results in high cumulative percentage ventricular pacing (Cum%VP). We hypothesized that a new managed v...
journal_title:Journal of cardiovascular electrophysiology
pub_type: 临床试验,杂志文章,多中心研究,随机对照试验
doi:10.1111/j.1540-8167.2005.40766.x
更新日期:2005-08-01 00:00:00