Analysis of measurements from the first Swedish universal neonatal hearing screening program.

Abstract:

:This study analyses results from the first Swedish UNHS program. It includes over 33 000 measurement files from 14 287 children at two maternity wards. The screening program uses a two-stage TEOAE test procedure. A database was created in MedLog after data transformation in Word and Excel. The coverage rate was 99.1%. Bilateral pass rate after retesting was 97.0%. A unilateral pass criterion would have resulted in 1268 fewer children (9.0% of target group) for retesting and 231 fewer children (1.6% of target group) for diagnostic evaluation. When the first test was performed on the day the child was born, the pass rate was 64.8%; the pass rate increased to 89.2% when testing> or =3 days after birth. High coverage rates and pass rates were found to be possible, independent of the number of children born at the maternity ward. Learning curves were observed in the program with improvements distributed over time. Test performance was clearly better when the children were tested day two after birth or later.

journal_name

Int J Audiol

authors

Hergils L

doi

10.1080/14992020701459868

subject

Has Abstract

pub_date

2007-11-01 00:00:00

pages

680-5

issue

11

eissn

1499-2027

issn

1708-8186

pii

783702043

journal_volume

46

pub_type

杂志文章
  • The role of catastrophizing in recent onset tinnitus: its nature and association with tinnitus distress and medical utilization.

    abstract:OBJECTIVE:Persistent tinnitus affects 10 to 15% of adults. Little is understood about why only a small percentage of patients become severely affected. Catastrophic thinking has been suggested as one potentially relevant factor that might influence a patient's coping behavior, and thus tinnitus habituation. The current...

    journal_title:International journal of audiology

    pub_type: 杂志文章

    doi:10.3109/14992027.2012.752111

    authors: Weise C,Hesser H,Andersson G,Nyenhuis N,Zastrutzki S,Kröner-Herwig B,Jäger B

    更新日期:2013-03-01 00:00:00

  • Development of a new method for deriving initial fittings for hearing aids with multi-channel compression: CAMEQ2-HF.

    abstract::Moore et al (1999b) described a procedure, CAMEQ, for the initial fitting of multi-channel compression hearing aids. The procedure was derived using a model of loudness perception for impaired hearing. We describe here the development of a new fitting method, CAMEQ2-HF, which differs from CAMEQ in the following ways: ...

    journal_title:International journal of audiology

    pub_type: 杂志文章

    doi:10.3109/14992020903296746

    authors: Moore BC,Glasberg BR,Stone MA

    更新日期:2010-03-01 00:00:00

  • Validity and reliability of in-situ air conduction thresholds measured through hearing aids coupled to closed and open instant-fit tips.

    abstract::Audiometric measurements through a hearing aid ('in-situ') may facilitate provision of hearing services where these are limited. This study investigated the validity and reliability of in-situ air conduction hearing thresholds measured with closed and open domes relative to thresholds measured with insert earphones, a...

    journal_title:International journal of audiology

    pub_type: 杂志文章

    doi:10.3109/14992027.2010.503664

    authors: O'Brien A,Keidser G,Yeend I,Hartley L,Dillon H

    更新日期:2010-12-01 00:00:00

  • Implications in disclosing auditory genetic mutation to a family: a case study.

    abstract::The aim of the study is to understand the implications of disclosing the results of connexin26 (Cx26) gene testing to the concerned family with hearing impaired individuals. The department of biotechnology is funding a multicentric multidisciplinary team from Jawaharlal Nehru Center for Advanced Scientific Research (B...

    journal_title:International journal of audiology

    pub_type: 杂志文章

    doi:10.1080/14992020701297805

    authors: Shekhawat GS,RamShankar M,Jalvi RR,Rangasayee R,Anand A

    更新日期:2007-07-01 00:00:00

  • A randomized control trial of interventions in school-aged children with auditory processing disorders.

    abstract:OBJECTIVE:The primary purpose of the study was to compare intervention approaches for children with auditory processing disorder (APD): bottom-up training including activities focused on auditory perception, discrimination, and phonological awareness, and top-down training including a range of language activities. Anot...

    journal_title:International journal of audiology

    pub_type: 杂志文章,随机对照试验

    doi:10.3109/14992027.2012.670272

    authors: Sharma M,Purdy SC,Kelly AS

    更新日期:2012-07-01 00:00:00

  • Long term hearing degeneration after platinum-based chemotherapy in childhood.

    abstract::The aim of this study was to investigate long-term development of hearing in subjects who had received platinum-based chemotherapy in childhood or adolescence. Another aim was to assess the self-reported hearing loss handicap and compare it to audiometric measurements. Medical records from individuals diagnosed with c...

    journal_title:International journal of audiology

    pub_type: 杂志文章

    doi:10.3109/14992027.2010.485595

    authors: Einarsson EJ,Petersen H,Wiebe T,Fransson PA,Grenner J,Magnusson M,Moëll C

    更新日期:2010-10-01 00:00:00

  • Effectiveness of computer-based auditory training for adult users of cochlear implants.

    abstract::Cochlear implantation is effective at restoring partial hearing to profoundly deaf adults, but not all patients receive equal benefit. The present study evaluated the effectiveness of a computer-based self-administered training package that was designed to improve speech perception among adults who had used cochlear i...

    journal_title:International journal of audiology

    pub_type: 杂志文章

    doi:10.3109/14992020903397838

    authors: Stacey PC,Raine CH,O'Donoghue GM,Tapper L,Twomey T,Summerfield AQ

    更新日期:2010-05-01 00:00:00

  • Comparison of two frequency-to-electrode maps for acoustic-electric stimulation.

    abstract::The fitting of a cochlear implant together with aided residual hearing was evaluated by means of matching frequency and/or perceived pitch between acoustic and electric modalities. Five cochlear implant users with the Nucleus Freedom electrode array with residual acoustic hearing participated. Psychophysical procedure...

    journal_title:International journal of audiology

    pub_type: 杂志文章

    doi:10.1080/14992020802452184

    authors: Simpson A,McDermott HJ,Dowell RC,Sucher C,Briggs RJ

    更新日期:2009-02-01 00:00:00

  • Total leisure noise exposure and its association with hearing loss among adolescents.

    abstract:OBJECTIVE:To investigate total leisure noise exposure among adolescents and to assess its association with hearing. DESIGN:Based on self-reported time spent on 19 leisure activities and associated mean sound pressure levels reported in the literature, total leisure noise exposure was evaluated and compared to noise at...

    journal_title:International journal of audiology

    pub_type: 杂志文章

    doi:10.3109/14992027.2015.1030510

    authors: Dehnert K,Raab U,Perez-Alvarez C,Steffens T,Bolte G,Fromme H,Twardella D

    更新日期:2015-01-01 00:00:00

  • College students' personal listening device usage and knowledge.

    abstract:OBJECTIVE:To determine the usage and knowledge of safe limits on personal listening devices (PLD) among college students. DESIGN:First, information on health history was collected. Second, microphone in real ear techniques determined eardrum to free-field correction factors. Third, hearing levels were evaluated and in...

    journal_title:International journal of audiology

    pub_type: 杂志文章

    doi:10.3109/14992027.2014.986691

    authors: Hutchinson Marron K,Marchiondo K,Stephenson S,Wagner S,Cramer I,Wharton T,Hughes M,Sproat B,Alessio H

    更新日期:2015-06-01 00:00:00

  • Predisposing factors for inner ear hearing loss association with chronic otitis media.

    abstract::The aim of the present study was to investigate the consequences of chronic otitis media on inner ear function. Retrospective analysis of conventional pure-tone audiometry tests was carried out on 344 patients who were scheduled for surgical treatment of unilateral chronic otitis media without other risk factors for s...

    journal_title:International journal of audiology

    pub_type: 杂志文章

    doi:10.1080/14992020500243737

    authors: Redaelli de Zinis LO,Campovecchi C,Parrinello G,Antonelli AR

    更新日期:2005-10-01 00:00:00

  • Neonatal hearing screening in Albania: results from an ongoing universal screening program.

    abstract::The paper describes the outcomes of an ongoing universal hearing screening program in Tirana, Albania. The main objectives of the project were the evaluation of the feasibility of a neonatal hearing screening program in Albania, and an evaluation of the prevalence of risk factors in the NICU environment. One thousand ...

    journal_title:International journal of audiology

    pub_type: 杂志文章

    doi:10.1080/14992020601145310

    authors: Hatzopoulos S,Qirjazi B,Martini A

    更新日期:2007-04-01 00:00:00

  • Analysis of counted behaviors in a single-subject design: modeling of hearing-aid intervention in hearing-impaired patients with Alzheimer's disease.

    abstract::Clinical procedures related to patients with Alzheimer's Disease (AD) largely fail to address the patient's hearing. Given the challenges of this population, unconventional indicators of treatment efficacy may be required. Palmer et al (1999) reported on caregiver-tracked behaviors as outcome measures for hearing aid ...

    journal_title:International journal of audiology

    pub_type: 杂志文章

    doi:10.1080/14992020400022637

    authors: Durrant JD,Palmer CV,Lunner T

    更新日期:2005-01-01 00:00:00

  • Investigation into the verification of the Synapsys videonystagmography (VNG) Ulmer calibration system.

    abstract:OBJECTIVE:To assess the accuracy and stability of the Synapsys VNG Ulmer calibration system when the goggles and infrared camera are repositioned, and the accuracy of the equipment's geometric calibration system. DESIGN:Prospective data collection involved participants conducting the system's horizontal calibration te...

    journal_title:International journal of audiology

    pub_type: 杂志文章

    doi:10.3109/14992027.2014.900195

    authors: Corless N,Goggins S

    更新日期:2014-09-01 00:00:00

  • Mandarin lexical tone recognition in bimodal cochlear implant users.

    abstract::Objective: To assess the recognition of lexical tones in Mandarin-speaking bimodal cochlear implant (CI) subjects.Design: Lexical tone recognition in quiet and noise (SNR= +5 dB) was measured with electric stimulation (CI alone) or bimodal stimulation (CI + hearing aid (HA)). The recognition and confusion rates of the...

    journal_title:International journal of audiology

    pub_type: 杂志文章

    doi:10.1080/14992027.2020.1719437

    authors: Zhou Q,Bi J,Song H,Gu X,Liu B

    更新日期:2020-07-01 00:00:00

  • Gaps-in-noise (GIN©) test results in children with and without reading disabilities and phonological processing deficits.

    abstract:OBJECTIVE:To determine if the gaps-in-noise (GIN(©)) test could differentiate children with dyslexia and significant phonological awareness deficits from a group of children with normal reading skills. DESIGN:A prospective study of GIN test performance in two groups of children. Participants were administered routine ...

    journal_title:International journal of audiology

    pub_type: 杂志文章

    doi:10.3109/14992027.2012.733421

    authors: Zaidan E,Baran JA

    更新日期:2013-02-01 00:00:00

  • The efficacy of a structured group therapy intervention in improving communication and coping skills for adult cochlear implant recipients.

    abstract::This paper reports on an evaluation of a structured group therapy intervention for adult cochlear implant (CI) recipients designed to improve overall communication and coping skills. 33 adult CI recipients (14 males, 19 females; mean age 61; 1-14 years since Cl) participated in a 2-day structured group therapy interve...

    journal_title:International journal of audiology

    pub_type: 杂志文章

    doi:10.1080/14992020500060404

    authors: Heydebrand G,Mauze E,Tye-Murray N,Binzer S,Skinner M

    更新日期:2005-05-01 00:00:00

  • The ICF Core Sets for hearing loss: researcher perspective, Part II: Linking outcome measures to the International Classification of Functioning, Disability and Health (ICF).

    abstract:OBJECTIVE:To link outcome measures used in audiological research to the ICF classification and thereby describe audiological research from the ICF perspective. DESIGN:Through a peer-reviewed or a joint linking procedure, link outcome measures to the ICF classification system using standardized ICF linking rules. Addit...

    journal_title:International journal of audiology

    pub_type: 杂志文章,评审

    doi:10.3109/14992027.2013.858279

    authors: Granberg S,Möller K,Skagerstrand A,Möller C,Danermark B

    更新日期:2014-02-01 00:00:00

  • Diagnosis of amblyaudia in children referred for auditory processing assessment.

    abstract::Children (n = 141) referred to 5 clinical sites for auditory processing disorder assessment were tested with two dichotic listening tests, one with word pairs and the other with pairs of digits, as part of a comprehensive diagnostic battery. Scores from the Randomized Dichotic Digits Test and the Dichotic Words Test w...

    journal_title:International journal of audiology

    pub_type: 杂志文章,多中心研究

    doi:10.3109/14992027.2015.1128003

    authors: Moncrieff D,Keith W,Abramson M,Swann A

    更新日期:2016-01-01 00:00:00

  • Functional hearing quality in prelingually deaf school-age children and adolescents with cochlear implants.

    abstract:OBJECTIVE:This study investigated differences in functional hearing quality between youth with cochlear implants (CIs) and normal hearing (NH) peers, as well as associations between functional hearing quality and audiological measures, speech perception, language and executive functioning (EF). DESIGN:Youth with CIs a...

    journal_title:International journal of audiology

    pub_type: 杂志文章

    doi:10.1080/14992027.2020.1826586

    authors: Kronenberger WG,Bozell H,Henning SC,Montgomery CJ,Ditmars AM,Pisoni DB

    更新日期:2020-10-01 00:00:00

  • Prevalence of hearing loss and associated factors in subjects with normal otoscopy: a national cross-sectional study.

    abstract:OBJECTIVE:To report the prevalence of hearing loss (HL) and associated factors in a nationwide study. DESIGN:Cross-sectional study. STUDY SAMPLE:We investigated the prevalence of HL in 10,845 participants ≥12 years of age and analysed the associated factors with HL from 7434 participants ≥40 years of age. RESULTS:Th...

    journal_title:International journal of audiology

    pub_type: 杂志文章

    doi:10.1080/14992027.2017.1373866

    authors: Park HJ,Yoo MH,Woo SY,Kim SW,Cho YS

    更新日期:2017-12-01 00:00:00

  • Acquired profound hearing loss: mental health and other characteristics of a large sample.

    abstract::The study investigated the mental health and other characteristics of people with acquired profound hearing loss (APHL) and contrasted this group with acquired hearing loss (AHL) in general. A survey was completed over the internet by 95 adults and by 27 people who had attended a one-week course of rehabilitation. The...

    journal_title:International journal of audiology

    pub_type: 杂志文章

    doi:10.1080/14992020600957335

    authors: Hallam R,Ashton P,Sherbourne K,Gailey L

    更新日期:2006-12-01 00:00:00

  • Detection and reaction thresholds for reverse alarms in noise with and without passive hearing protection.

    abstract:OBJECTIVE:To measure masked detection and reaction thresholds for two reverse alarms (tonal and broadband) and compare results to available standards and psychoacoustic criteria for setting alarm levels. DESIGN:Alarm detection and reaction thresholds were adaptively measured in 80-dBA background noises without hearing...

    journal_title:International journal of audiology

    pub_type: 杂志文章

    doi:10.1080/14992027.2017.1400188

    authors: Laroche C,Giguère C,Vaillancourt V,Roy K,Pageot LP,Nélisse H,Ellaham N,Nassrallah F

    更新日期:2018-02-01 00:00:00

  • A convergent validity study: Listening in Spatialized Noise-Sentences (LiSN-S) test and the Hearing in Noise Test (HINT).

    abstract:OBJECTIVES:The primary purpose of this study was to compare Listening in Spatialized Noise - Sentence (LiSN-S) test and the Hearing in Noise Test (HINT) thresholds in order to determine if the two tests measure the same construct (convergent validity). The secondary purpose was to determine performance differences betw...

    journal_title:International journal of audiology

    pub_type: 杂志文章

    doi:10.1080/14992027.2020.1791367

    authors: Vermiglio AJ,Bulla E,Skinner J,Heeke P,Fang X,Velappan K,Bonilla E,Garner E

    更新日期:2021-01-01 00:00:00

  • Effects of consecutive trials and test-retest reliability of 1000-Hz tympanometry in adults.

    abstract:OBJECTIVE:To investigate the effect of consecutive 1000-Hz tympanometry testing on admittance measures, and examine test-retest reliability. DESIGN:Repeated measures with eight trials of 1000-Hz Y(a) and B(a)/G(a) tympanometry, respectively, in two ears of each subject, followed by repeated 226-Hz tympanometry. STUDY...

    journal_title:International journal of audiology

    pub_type: 杂志文章

    doi:10.3109/14992027.2014.955888

    authors: Carazo CD,Sun XM

    更新日期:2015-04-01 00:00:00

  • Hearing among 75-year-old people in three Nordic localities: a comparative study.

    abstract::The aim of this study was to compare auditory functions and to analyse the prevalence of hearing impairment and the relationship of self-reported hearing disability with audiometric test results among 75-year-old people in three Nordic localities. The representative samples came from Glostrup, Denmark (n = 571), Göteb...

    journal_title:International journal of audiology

    pub_type: 杂志文章

    doi:10.1080/14992020500189112

    authors: Hietanen A,Era P,Henrichsen J,Rosenhall U,Sorri M,Heikkinen E

    更新日期:2005-09-01 00:00:00

  • Effect of inverting electrode on mismatch negativity presence for perceptible/imperceptible tonal frequency contrasts.

    abstract::The effect of inverting electrode location and stimulus perceptibility on the presence of the mismatch negativity (MMN) evoked response was investigated in 20 normal-hearing adult females. Perceptible and imperceptible frequency contrasts were employed in an oddball paradigm. The perceptible contrast consisted of an 1...

    journal_title:International journal of audiology

    pub_type: 杂志文章

    doi:10.1080/14992020802283241

    authors: Walker-Black L,Stuart A

    更新日期:2008-11-01 00:00:00

  • Demands on hearing aid features--special signal processing for elderly users?

    abstract::Age-related effects on several parameters of hearing aid provision, comprising the importance of various hearing aid attributes, the main reason for dissatisfaction, and a measure for aided performance, were examined. When comparing two subgroups of younger and elderly hearing aid users, a significant difference occur...

    journal_title:International journal of audiology

    pub_type: 杂志文章,多中心研究

    doi:

    authors: Meister H,von Wedel H

    更新日期:2003-07-01 00:00:00

  • On differentiating auditory processing disorder (APD) from attention deficit disorder (ADD): an illustrative example using the Cattell-Horn-Carroll (CHC) model of cognitive abilities.

    abstract::Objective: To clarify the distinction between Auditory Processing Disorder (APD) and Attention Deficit Disorder (ADD) using the CHC Model.Design: A cross-sectional study compared responses of caregivers about their children's behaviour to identify characteristics of APD (CHC Model) and ADD (DSM-5).Study Sample: Caregi...

    journal_title:International journal of audiology

    pub_type: 杂志文章

    doi:10.1080/14992027.2019.1682199

    authors: Bench J,Jacobs K,Furlonger B

    更新日期:2020-03-01 00:00:00

  • The next generation of Nucleus(®) fitting: a multiplatform approach towards universal cochlear implant management.

    abstract:OBJECTIVE:This article provides a detailed description and evaluation of the next Nucleus(®) cochlear implant fitting suite. A new fitting methodology is presented that, at its simplest level, requires a single volume adjustment, and at its advanced level, provides access to 22-channel fitting. It is implemented on mul...

    journal_title:International journal of audiology

    pub_type: 杂志文章,随机对照试验

    doi:10.3109/14992027.2013.781277

    authors: Botros A,Banna R,Maruthurkkara S

    更新日期:2013-07-01 00:00:00