A robust method to extract the anterior pelvic plane from CT volume independent of pelvic pose.

Abstract:

PURPOSE:The anterior pelvic plane (APP) is commonly used as a reference plane to assess acetabular orientation. However, conventional methods for determining the APP may not be accurate and are prone to user variability. To overcome these issues, we developed a robust method to accurately extract the APP independent of pelvic pose using three-dimensional pelvic computed tomography (CT). MATERIALS AND METHODS:Twenty-eight studies for suspected nonmusculoskeletal conditions were obtained. The APP was determined by four landmarks that were automatically extracted from user-defined regions of interest (ROIs) with compensation of pelvic pose. The APP defined from these landmarks was quantitatively compared to the APPs determined by an expert and an unskilled. Intraobserver reliability was measured to evaluate the time-interval variability. Finally, we evaluate the robustness of this method to patient posture using an arbitrarily rotated volume. The intraclass correlation coefficients (ICCs) were calculated to determine the interobserver and intraobserver reliabilities. RESULTS:The ICC values for the four landmarks and the APP were similar between the semiautomated method and expert determination (ICC >0.937). The ICC values for intraobserver reliability over time for our method were all 1, demonstrating high reliability. Furthermore, agreement between the parameters determined from the original volume and the rotated volume was nearly perfect. CONCLUSIONS:Our method is a useful measurement tool for the APP as it is robust, and the results were similar to an experienced surgeon's determination. Furthermore, it was independent to the direction of the CT slice and more robust than a measurement by an unskilled.

authors

Lee C,Kim Y,Kim HW,Kim YS,Jang J

doi

10.1080/24699322.2017.1293737

keywords:

["Anterior pelvic plane","acetabular hip orientation","anatomical landmark","pelvic coordinate"]

subject

Has Abstract

pub_date

2017-12-01 00:00:00

pages

20-26

issue

1

issn

2469-9322

journal_volume

22

pub_type

杂志文章

相关文献

文献大全
  • How does adding anatomical landmarks as fiducial points in the point-matching registration of neuronavigation influence registration accuracy?

    abstract::Skin markers (SMs) are usually used as fiducial points in registration of neuronavigation, but the areas in which they can be adhered to are restricted, which usually results in poor distribution of the SMs and a large registration error. In this research, we studied whether the registration accuracy can be improved b...

    journal_title:Computer assisted surgery (Abingdon, England)

    pub_type: 杂志文章

    doi:10.1080/24699322.2016.1180429

    authors: Wang M,Song Z

    更新日期:2016-12-01 00:00:00

  • Tracking multiple surgical instruments in a near-infrared optical system.

    abstract::Surgical navigation systems can assist doctors in performing more precise and more efficient surgical procedures to avoid various accidents. The near-infrared optical system (NOS) is an important component of surgical navigation systems. However, several surgical instruments are used during surgery, and effectively tr...

    journal_title:Computer assisted surgery (Abingdon, England)

    pub_type: 杂志文章

    doi:10.1080/24699322.2016.1184312

    authors: Cai K,Yang R,Lin Q,Wang Z

    更新日期:2016-12-01 00:00:00

  • Computer aided diagnosis sensor integrated outdoor shirts for real time heart disease monitoring.

    abstract::The typical method of monitoring arrhythmia is to use a body patch type sensor with a wet electrode. It has several problems caused by wet electrodes for long-term monitoring. Thus, a monitoring sensor integrated into clothes with a dry electrode is proposed. In this study, we develop a smart outdoor shirt equipped wi...

    journal_title:Computer assisted surgery (Abingdon, England)

    pub_type: 杂志文章

    doi:10.1080/24699322.2017.1389396

    authors: Park JA,Han HJ,Heo JC,Lee JH

    更新日期:2017-12-01 00:00:00

  • Optimal distance of multi-plane sensor in three-dimensional electrical impedance tomography.

    abstract::Electrical impedance tomography (EIT) is a visual imaging technique for obtaining the conductivity and permittivity distributions in the domain of interest. As an advanced technique, EIT has the potential to be a valuable tool for continuously bedside monitoring of pulmonary function. The EIT applications in any three...

    journal_title:Computer assisted surgery (Abingdon, England)

    pub_type: 杂志文章

    doi:10.1080/24699322.2017.1389412

    authors: Hao Z,Yue S,Sun B,Wang H

    更新日期:2017-12-01 00:00:00

  • Accuracy analysis of line-based registration for image guided neurosurgery at different operating areas - a phantom study.

    abstract::Space registration is the primary function of neuronavigation systems. According to the stage of the operation, the registration could be classified as rigid and non-rigid methods. Scientists have proposed three types of rigid registration methods: point-based registration (PBR), line-based registration (LBR), and sur...

    journal_title:Computer assisted surgery (Abingdon, England)

    pub_type: 杂志文章

    doi:10.1080/24699322.2017.1389392

    authors: Ji D,Dong Y,Wang M,Song Z

    更新日期:2017-12-01 00:00:00

  • A new robust markerless method for automatic image-to-patient registration in image-guided neurosurgery system.

    abstract:BACKGROUND:Compared with the traditional point-based registration in the image-guided neurosurgery system, surface-based registration is preferable because it does not use fiducial markers before image scanning and does not require image acquisition dedicated for navigation purposes. However, most existing surface-base...

    journal_title:Computer assisted surgery (Abingdon, England)

    pub_type: 杂志文章

    doi:10.1080/24699322.2017.1389411

    authors: Liu Y,Song Z,Wang M

    更新日期:2017-12-01 00:00:00

  • A study on quality assessment of the surface EEG signal based on fuzzy comprehensive evaluation method.

    abstract::Surface EEG (Electroencephalography) signal is vulnerable to interference due to its characteristics and sampling methods. So it is of great importance to evaluate the collected EEG signal prior to use. Traditional methods usually use the impedance between skin and electrode to estimate the quality of the EEG signal, ...

    journal_title:Computer assisted surgery (Abingdon, England)

    pub_type: 杂志文章

    doi:10.1080/24699322.2018.1557888

    authors: Liu D,Wang Q,Zhang Y,Liu X,Lu J,Sun J

    更新日期:2019-10-01 00:00:00

  • A sensorless force-feedback system for robot-assisted laparoscopic surgery.

    abstract::The existing surgical robots for laparoscopic surgery offer no or limited force feedback, and there are many problems for the traditional sensor-based solutions. This paper builds a teleoperation surgical system and validates the effectiveness of sensorless force feedback. The tool-tissue interaction force at the surg...

    journal_title:Computer assisted surgery (Abingdon, England)

    pub_type: 杂志文章

    doi:10.1080/24699322.2018.1557887

    authors: Zhao B,Nelson CA

    更新日期:2019-10-01 00:00:00

  • A targeting method for robot-assisted percutaneous needle placement under fluoroscopy guidance.

    abstract::Minimally invasive procedures are rapidly growing in popularity thanks to advancements in medical robots, visual navigation and space registration techniques. This paper presents a precise and efficient targeting method for robot-assisted percutaneous needle placement under C-arm fluoroscopy. In this method, a special...

    journal_title:Computer assisted surgery (Abingdon, England)

    pub_type: 杂志文章

    doi:10.1080/24699322.2018.1557907

    authors: Han Z,Yu K,Hu L,Li W,Yang H,Gan M,Guo N,Yang B,Liu H,Wang Y

    更新日期:2019-10-01 00:00:00

  • The process of 3D printed skull models for anatomy education.

    abstract::In general, the 3 D printed medical models are made based on virtual digital models obtained from machines such as the computed tomography scanner. However, due to the limited accuracy of CT scanning technology, which is usually 1 millimeter, there are differences between scanned results and the real structure. Beside...

    journal_title:Computer assisted surgery (Abingdon, England)

    pub_type: 杂志文章

    doi:10.1080/24699322.2018.1560101

    authors: Shen Z,Yao Y,Xie Y,Guo C,Shang X,Dong X,Li Y,Pan Z,Chen S,Xiong G,Wang FY,Pan H

    更新日期:2019-10-01 00:00:00

  • Modeling of soft tissue thermal damage based on GPU acceleration.

    abstract::Hyperthermia treatments require precise control of thermal energy to form the coagulation zones which sufficiently cover the tumor without affecting surrounding healthy tissues. This has led modeling of soft tissue thermal damage to become important in hyperthermia treatments to completely eradicate tumors without ind...

    journal_title:Computer assisted surgery (Abingdon, England)

    pub_type: 杂志文章

    doi:10.1080/24699322.2018.1557891

    authors: Zhang J,Hills J,Zhong Y,Shirinzadeh B,Smith J,Gu C

    更新日期:2019-10-01 00:00:00

  • Three-dimension correction of Charcot ankle deformity with a titanium implant.

    abstract:BACKGROUND:Charcot neuroarthropathy of the ankle is an extremely challenging clinical dilemma, and its surgical management can be highly complicated. The goal of Charcot ankle treatment is to to restore a plantigrade and stable foot, and thus to avoid ulceration with subsequent infection. This report aims to introduce ...

    journal_title:Computer assisted surgery (Abingdon, England)

    pub_type: 杂志文章

    doi:10.1080/24699322.2021.1887356

    authors: Wang G,Lin J,Zhang H,Pei Y,Zhu L,Xu Q

    更新日期:2021-12-01 00:00:00