A robust VMAT delivery solution for single-fraction lung SABR utilizing FFF beams minimizing dosimetric compromise.

Abstract:

:Peripheral lung lesions treated with a single fraction of stereotactic ablative body radiotherapy (SABR) utilizing volumetric modulated arc therapy (VMAT) delivery and flattening filter-free (FFF) beams represent a potentially high-risk scenario for clinically significant dose blurring effects due to interplay between the respiratory motion of the lesion and dynamic multi-leaf collimators (MLCs). The aim of this study was to determine an efficient means of developing low-modulation VMAT plans in the Eclipse treatment planning system (v15.5, Varian Medical Systems, Palo Alto, USA) in order to minimize this risk, while maintaining dosimetric quality. The study involved 19 patients where an internal target volume (ITV) was contoured to encompass the entire range of tumor motion, and a planning target volume (PTV) created using a 5-mm isotropic expansion of this contour. Each patient had seven plan variations created, with each rescaled to achieve the clinical planning goal for PTV coverage. All plan variations used the same field arrangement, and consisted of one dynamic conformal arc therapy (DCAT) plan, and six VMAT plans with varying degrees of modulation restriction, achieved through utilizing different combinations of the aperture shape controller (ASC) in the calculation parameters, and monitor unit (MU) objective during optimization. The dosimetric quality was assessed based on RTOG conformity indices (CI100/CI50), as well as adherence to dose-volume metrics used clinically at our institution. Plan complexity was assessed based on the modulation factor (MU/cGy) and the field edge metric. While VMAT plans with the least modulation restriction achieved the best dosimetry, it was found that there was no clinically significant trade-off in terms of dose to organs at risk and conformity by reducing complexity. Furthermore, it was found that utilizing the ASC and MU objective could reduce plan complexity to near-DCAT levels with improved dosimetry, which may be sufficiently robust to overcome the interplay effect.

journal_name

J Appl Clin Med Phys

authors

Burton A,Offer K,Hardcastle N

doi

10.1002/acm2.12919

subject

Has Abstract

pub_date

2020-08-01 00:00:00

pages

299-304

issue

8

issn

1526-9914

journal_volume

21

pub_type

杂志文章
  • Improving a scissor-action couch for conformal arc radiotherapy and radiosurgery.

    abstract::We have developed a method to improve the setup accuracy of a Varian Clinac 6/100 couch for delivering conformal arc therapy using a tertiary micro multileaf collimator (MLC) system. Several immobilization devices have been developed to improve the mechanical stability and isocenter alignment of the couch: turn-knob h...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v5i3.2026

    authors: Li K,Yu CX,Ma L

    更新日期:2004-07-01 00:00:00

  • Translucent poly(vinyl alcohol) cryogel dosimeters for simultaneous dose buildup and monitoring during chest wall radiation therapy.

    abstract::Chest wall radiation therapy treatment delivery was monitored using a 5 mm thick radiochromic poly(vinyl alcohol) cryogel that also provided buildup material. The cryogels were used to detect positioning errors and measure the impact of shifts for a chest wall treatment that was delivered to a RANDO phantom. The phant...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v17i5.6148

    authors: Eyadeh MM,Weston MA,Juhasz J,Diamond KR

    更新日期:2016-09-08 00:00:00

  • Amplitude gating for a coached breathing approach in respiratory gated 10 MV flattening filter-free VMAT delivery.

    abstract::The purpose of this study was to investigate amplitude gating combined with a coached breathing strategy for 10 MV flattening filter-free (FFF) volumetric-modulated arc therapy (VMAT) on the Varian TrueBeam linac. Ten patient plans for VMAT SABR liver were created using the Eclipse treatment planning system (TPS). The...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v16i4.5350

    authors: Viel F,Lee R,Gete E,Duzenli C

    更新日期:2015-07-08 00:00:00

  • Shielding assessment of a mobile electron accelerator for intra-operative radiotherapy.

    abstract::The purpose of this investigation is to measure, characterize and report stray photon leakage and scatter radiation measurements from the Mobetron, an intraoperative electron linear accelerator designed for use in an operating room environment. The study is needed due to recent changes to the shielding design of the M...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v11i4.3151

    authors: Krechetov AS,Goer D,Dikeman K,Daves JL,Mills MD

    更新日期:2010-09-07 00:00:00

  • Assessment and management of radiotherapy beam intersections with the treatment couch.

    abstract::The impact of the treatment couch on a radiotherapy plan is rarely fully assessed during the treatment planning process. Incorporating a couch model into the treatment planning system (TPS) enables the planner to avoid or dosimetrically evaluate beam-couch intersections. In this work, we demonstrate how existing TPS t...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v11i2.3171

    authors: Van Prooijen M,Kanesalingam T,Islam MK,Heaton RK

    更新日期:2010-04-19 00:00:00

  • A new frontier of image guidance: Organs at risk avoidance with MRI-guided respiratory-gated intensity modulated radiotherapy: Technical note and report of a case.

    abstract::The case of a 50-year-old man affected by a rhabdomiosarcoma metastatic lesion in the left flank Is reported. The patient was addressed to 50.4 Gy radiotherapy with concomitant chemotherapy in order to locally control the lesion. A Tri-60-Co magnetic resonance hybrid radiotherapy unit was used for treatment delivery a...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12575

    authors: Massaccesi M,Cusumano D,Boldrini L,Dinapoli N,Fionda B,Teodoli S,Azario L,Mattiucci GC,Balducci M,Cellini F,Valentini V

    更新日期:2019-06-01 00:00:00

  • Standardized flattening filter free volumetric modulated arc therapy plans based on anteroposterior width for total body irradiation.

    abstract::In this work, the feasibility of using flattening filter free (FFF) beams in volumetric modulated arc therapy (VMAT) total body irradiation (TBI) treatment planning to decrease protracted beam-on times for these treatments was investigated. In addition, a methodology was developed to generate standardized VMAT TBI tre...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12827

    authors: Frederick R,Hudson A,Balogh A,Cao JQ,Pierce G

    更新日期:2020-03-01 00:00:00

  • A clinical 3D/4D CBCT-based treatment dose monitoring system.

    abstract::To monitor delivered dose and trigger plan adaptation when deviation becomes unacceptable, a clinical treatment dose (Tx-Dose) reconstruction system based on three-dimensional (3D)/four-dimensional (4D)-cone beam computed tomograpy (CBCT) images was developed and evaluated on various treatment sites, particularly for ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12474

    authors: Qin A,Gersten D,Liang J,Liu Q,Grill I,Guerrero T,Stevens C,Yan D

    更新日期:2018-11-01 00:00:00

  • On the use of bolus for pacemaker dose measurement and reduction in radiation therapy.

    abstract::Special attention is required in planning and administering radiation therapy to patients with cardiac implantable electronic devices (CIEDs), such as pacemaker and defibrillator. The range of dose to CIEDs that can induce malfunction is large among CIEDs. Clinically significant defects have been reported at dose as l...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12229

    authors: Yan H,Guo F,Zhu D,Stryker S,Trumpore S,Roberts K,Higgins S,Nath R,Chen Z,Liu W

    更新日期:2018-01-01 00:00:00

  • Electrocardiogram-gated coronary CT angiography dose estimates using ImPACT.

    abstract::The primary study objective was to assess radiation doses using a modified form of the Imaging Performance Assessment of Computed Tomography (CT) scanner (ImPACT) patient dosimetry for cardiac applications on an Aquilion ONE ViSION Edition scanner, including the Ca score, target computed tomography angiography (CTA), ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v17i4.6218

    authors: Kobayashi M,Asada Y,Matsubara K,Suzuki S,Koshida K,Matsunaga Y,Haba T,Kawaguchi A,Toyama H,Kato R

    更新日期:2016-07-08 00:00:00

  • Measurement of gantry rotation time in modern ct.

    abstract::The purpose of this study was to develop and evaluate a noninvasive method to assess rotation time in modern commercial computed tomography (CT) systems. The rotation time was measured at a selected nominal rotation time (400 ms) utilizing two types of solid-state detectors: the RTI's CT Dose Profiler (CTDP) and Unfor...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v15i1.4517

    authors: Fukuda A,Lin PJ,Matsubara K,Miyati T

    更新日期:2014-01-06 00:00:00

  • Introduction to passive electron intensity modulation.

    abstract::This work introduces a new technology for electron intensity modulation, which uses small area island blocks within the collimating aperture and small area island apertures in the collimating insert. Due to multiple Coulomb scattering, electrons contribute dose under island blocks and lateral to island apertures. By s...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12163

    authors: Hogstrom KR,Carver RL,Chambers EL,Erhart K

    更新日期:2017-11-01 00:00:00

  • Using C-Arm X-ray images from marker insertion to confirm the gold fiducial marker identification in an MRI-only prostate radiotherapy workflow.

    abstract::Prostate cancer radiotherapy workflows, solely based on magnetic resonance imaging (MRI), are now in clinical use. In these workflows, intraprostatic gold fiducial markers (GFM) show similar signal behavior as calcifications and bleeding in T2-weighted MRI-images. Accurate GFM identification in MRI-only radiotherapy w...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12478

    authors: Gustafsson C,Persson E,Gunnlaugsson A,Olsson LE

    更新日期:2018-11-01 00:00:00

  • Fluoroscopic evaluation of diaphragmatic motion reduction with a respiratory gated radiotherapy system.

    abstract::We report on initial patient studies to evaluate the performance of a commercial respiratory gating radiotherapy system. The system uses a breathing monitor, consisting of a video camera and passive infrared reflective markers placed on the patient's thorax, to synchronize radiation from a linear accelerator with the ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v2i4.2596

    authors: Mageras GS,Yorke E,Rosenzweig K,Braban L,Keatley E,Ford E,Leibel SA,Ling CC

    更新日期:2001-10-01 00:00:00

  • A novel and clinically useful dynamic conformal arc (DCA)-based VMAT planning technique for lung SBRT.

    abstract:PURPOSE:Volumetric modulated arc therapy (VMAT) is gaining popularity for stereotactic treatment of lung lesions for medically inoperable patients. Due to multiple beamlets in delivery of highly modulated VMAT plans, there are dose delivery uncertainties associated with small-field dosimetry error and interplay effects...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12878

    authors: Pokhrel D,Visak J,Sanford L

    更新日期:2020-07-01 00:00:00

  • Gantry angle determination during arc IMRT: evaluation of a simple EPID-based technique and two commercial inclinometers.

    abstract::The increasing popularity of intensity-modulated arc therapy (IMAT) treatments requires specifically designed linac quality assurance (QA) programs. Gantry angle is one of the parameters that has a major effect on the outcome of IMAT treatments since dose reconstruction for patient-specific QA relies on the gantry ang...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v13i6.3981

    authors: Rowshanfarzad P,Sabet M,O'Connor DJ,McCowan PM,McCurdy BM,Greer PB

    更新日期:2012-11-08 00:00:00

  • The performance of the progressive resolution optimizer (PRO) for RapidArc planning in targets with low-density media.

    abstract::A new version of progressive resolution optimizer (PRO) with an option of air cavity correction has been implemented for RapidArc volumetric-modulated arc therapy (RA). The purpose of this study was to compare the performance of this new PRO with the use of air cavity correction option (PRO10_air) against the one with...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v14i6.4382

    authors: Kan MW,Leung LH,Yu PK

    更新日期:2013-11-04 00:00:00

  • Superficial and peripheral dose in compensator-based FFF beam IMRT.

    abstract::Flattening filter-free (FFF) beams produce higher dose rates. Combined with compensator-based intensity modulated radiotherapy (IMRT) techniques, the dose delivery for each beam can be much shorter compared to the flattened beam MLC-based or flattened beam compensator-based IMRT. This 'snap shot' IMRT delivery is bene...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12018

    authors: Zhang DG,Feygelman V,Moros EG,Latifi K,Hoffe S,Frakes J,Zhang GG

    更新日期:2017-01-01 00:00:00

  • Commissioning of the Mobius3D independent dose verification system for TomoTherapy.

    abstract::In radiation therapy, a secondary independent dose verification is an important component of a quality control system. Mobius3D calculates three-dimensional (3D) patient dose using reference beam data and a collapsed cone convolution algorithm and analyzes dose-volume histogram automatically. There are currently no pu...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12572

    authors: Kodama T,Saito Y,Hatanaka S,Hariu M,Shimbo M,Takahashi T

    更新日期:2019-05-01 00:00:00

  • Strategies to optimize stereotactic radiosurgery plans for brain tumors with volumetric-modulated arc therapy.

    abstract:PURPOSE:Prescription practice in SRS plans for brain tumors differs significantly for different modalities. In this retrospective study, the strategies to optimize SRS plans for brain tumors with volumetric arc therapy (VMAT) were presented. METHODS:Fifty clinically treated cases were stratified by the maximum target ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12818

    authors: Wang D,DeNittis A,Hu Y

    更新日期:2020-03-01 00:00:00

  • Detector system dose verification comparisons for arc therapy: couch vs. gantry mount.

    abstract::The aim of this study was to assess the performance of a gantry-mounted detector system and a couch set detector system using a systematic multileaf collimator positional error manually introduced for volumetric-modulated arc therapy. Four head and neck and esophagus VMAT plans were evaluated by measurement using an e...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v15i3.4495

    authors: Manikandan A,Sarkar B,Nandy M,Sureka CS,Gossman MS,Sujatha N,Rajendran VT

    更新日期:2014-05-08 00:00:00

  • Can Hyperpolarized Helium MRI add to radiation planning and follow-up in lung cancer?

    abstract::Locally advanced non-small-cell lung cancer (NSCLC) is a common disease with a low overall survival even with aggressive treatments. Standard imaging (CT and PET/CT) provide no information about normal lung function. We therefore, sought to pilot HeMRI in patients with non-small-cell lung cancer before and after defin...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v12i2.3357

    authors: Allen AM,Albert M,Caglar HB,Zygmanski P,Soto R,Killoran J,Sun Y

    更新日期:2011-01-31 00:00:00

  • Defining internal target volume using positron emission tomography for radiation therapy planning of moving lung tumors.

    abstract::Substantial disagreement exists over appropriate PET segmentation techniques for non-small cell lung cancer. Currently, no segmentation algorithm explicitly considers tumor motion in determining tumor borders. We developed an automatic PET segmentation model as a function of target volume, motion extent, and source-to...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v15i1.4600

    authors: Riegel AC,Bucci MK,Mawlawi OR,Ahmad M,Luo D,Chandler A,Pan T

    更新日期:2014-01-06 00:00:00

  • Interfraction positional variation in pancreatic tumors using daily breath-hold cone-beam computed tomography with visual feedback.

    abstract::We assessed interfraction positional variation in pancreatic tumors using daily breath-hold cone-beam computed tomography at end-exhalation (EE) with visual feedback (BH-CBCT). Eleven consecutive patients with pancreatic cancer who underwent BH intensity-modulated radiation therapy with visual feedback were enrolled. ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v16i2.5123

    authors: Nakamura M,Akimoto M,Ono T,Nakamura A,Yano S,Nakata M,Itasaka S,Mizowaki T,Shibuya K,Hiraoka M

    更新日期:2015-03-08 00:00:00

  • Quantification and reduction of peripheral dose from leakage radiation on Siemens Primus accelerators in electron therapy mode.

    abstract::In this work, leakage radiation from EA200 series electron applicators on Siemens Primus accelerators is quantified, and its penetration ability in water and/or the shielding material Xenolite-NL established. Initially, measurement of leakage from 10 x 10 - 25 x 25 cm2 applicators was performed as a function of height...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v11i3.3105

    authors: Yeboah C,Karotki A,Hunt D,Holly R

    更新日期:2010-06-15 00:00:00

  • Monte Carlo investigation of collapsed versus rotated IMRT plan verification.

    abstract::IMRT QA requires, among other tests, a time-consuming process of measuring the absorbed dose, at least to a point, in a high-dose, low-dose-gradient region. Some clinics use a technique of measuring this dose with all beams delivered at a single gantry angle (collapsed delivery), as opposed to the beams delivered at t...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v15i3.4681

    authors: Conneely E,Alexander A,Ruo R,Chung E,Seuntjens J,Foley MJ

    更新日期:2014-05-08 00:00:00

  • Role of adaptive radiation therapy for pediatric patients with diffuse pontine glioma.

    abstract::We investigate the role of adaptive radiation therapy in pediatric patients with diffuse pontine glioma and the impact of steroid-related weight gain on treatment parameters utilizing cone-beam CT. Fifteen patients with diffuse pontine glioma were treated with three-dimensional conformal radiation therapy and enrolled...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:

    authors: Beltran C,Sharma S,Merchant TE

    更新日期:2011-01-30 00:00:00

  • Utilization of cone beam CT for reconstruction of dose distribution delivered in image-guided radiotherapy of prostate carcinoma - bony landmark setup compared to fiducial markers setup.

    abstract::The purpose of this study was to compare two different styles of prostate IGRT: bony landmark (BL) setup vs. fiducial markers (FM) setup. Twenty-nine prostate patients were treated with daily BL setup and 30 patients with daily FM setup. Delivered dose distribution was reconstructed on cone-beam CT (CBCT) acquired onc...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v14i3.4203

    authors: Paluska P,Hanus J,Sefrova J,Rouskova L,Grepl J,Jansa J,Kasaova L,Hodek M,Zouhar M,Vosmik M,Petera J

    更新日期:2013-05-06 00:00:00

  • Measurement of the interplay effect in lung IMRT treatment using EDR2 films.

    abstract::Intra-fraction organ motion during the dynamic delivery of IMRT treatment of lung tumors may cause unexpected hot/cold spots even within the target volume, due to the interplay effect between tumor motion and multi-leaf collimator (MLC) leaf motion. In the past, this has been investigated through theoretical analysis,...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v7i4.2222

    authors: Berbeco RI,Pope CJ,Jiang SB

    更新日期:2006-11-28 00:00:00

  • Photon and electron backscatter dose and energy spectrum analysis around Lipiodol using flattened and unflattened beams.

    abstract:PURPOSE:The aim of the current study was to evaluate the backscatter dose and energy spectrum from the Lipiodol with flattening filter (FF) and flattening filter-free (FFF) beams. Moreover, the backscatter range, that was defined as the backscatter distance (BD) are revealed. METHODS:6 MVX FF and FFF beams were delive...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12560

    authors: Kawahara D,Ozawa S,Kimura T,Saito A,Nakashima T,Ohno Y,Murakami Y,Nagata Y,Shiinoki T

    更新日期:2019-06-01 00:00:00