Two-year experience with the commercial Gamma Knife Check software.

Abstract:

:The Gamma Knife Check software is an FDA approved second check system for dose calculations in Gamma Knife radiosurgery. The purpose of this study was to evaluate the accuracy and the stability of the commercial software package as a tool for independent dose verification. The Gamma Knife Check software version 8.4 was commissioned for a Leksell Gamma Knife Perfexion and a 4C unit at the University of Pittsburgh Medical Center in May 2012. Independent dose verifications were performed using this software for 319 radiosurgery cases on the Perfexion and 283 radiosurgery cases on the 4C units. The cases on each machine were divided into groups according to their diagnoses, and an averaged absolute percent dose difference for each group was calculated. The percentage dose difference for each treatment target was obtained as the relative difference between the Gamma Knife Check dose and the dose from the tissue maximum ratio algorithm (TMR 10) from the GammaPlan software version 10 at the reference point. For treatment plans with imaging skull definition, results obtained from the Gamma Knife Check software using the measurement-based skull definition method are used for comparison. The collected dose difference data were also analyzed in terms of the distance from the treatment target to the skull, the number of treatment shots used for the target, and the gamma angles of the treatment shots. The averaged percent dose differences between the Gamma Knife Check software and the GammaPlan treatment planning system are 0.3%, 0.89%, 1.24%, 1.09%, 0.83%, 0.55%, 0.33%, and 1.49% for the trigeminal neuralgia, acoustic neuroma, arteriovenous malformation (AVM), meningioma, pituitary adenoma, glioma, functional disorders, and metastasis cases on the Perfexion unit. The corresponding averaged percent dose differences for the 4C unit are 0.33%, 1.2%, 2.78% 1.99%, 1.4%, 1.92%, 0.62%, and 1.51%, respectively. The dose difference is, in general, larger for treatment targets in the peripheral regions of the skull owing to the difference in the numerical methods used for skull shape simulation in the GammaPlan and the Gamma Knife Check software. Larger than 5% dose differences were observed on both machines for certain targets close to patient skull surface and for certain targets in the lower half of the brain on the Perfexion, especially when shots with 70 and/or 110 gamma angles are used. Out of the 1065 treatment targets studied, a 5% cutoff criterion cannot always be met for the dose differences between the studied versions of the Gamma Knife Check software and the planning system for 40 treatment targets.

journal_name

J Appl Clin Med Phys

authors

Xu AY,Bhatnagar J,Bednarz G,Novotny J Jr,Flickinger J,Lunsford LD,Huq MS

doi

10.1120/jacmp.v17i4.5547

subject

Has Abstract

pub_date

2016-07-08 00:00:00

pages

95-105

issue

4

issn

1526-9914

journal_volume

17

pub_type

杂志文章
  • A protocol to extend the longitudinal coverage of on-board cone-beam CT.

    abstract::The longitudinal coverage of a LINAC-mounted CBCT scan is limited to the corresponding dimensional limits of its flat panel detector, which is often shorter than the length of the treatment field. These limits become apparent when fields are designed to encompass wide regions, as when providing nodal coverage. Therefo...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v13i4.3796

    authors: Zheng D,Lu J,Jefferson A,Zhang C,Wu J,Sleeman W,Weiss E,Dogan N,Song S,Williamson J

    更新日期:2012-07-05 00:00:00

  • Design and dosimetry characteristics of a commercial applicator system for intra-operative electron beam therapy utilizing ELEKTA Precise accelerator.

    abstract::The design concept and dosimetric characteristics of a new applicator system for intraoperative radiation therapy (IORT) are presented in this work. A new hard-docking commercial system includes polymethylmethacrylate (PMMA) applicators with different diameters and applicator end angles and a set of secondary lead col...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v11i4.3244

    authors: Nevelsky A,Bernstein Z,Bar-Deroma R,Kuten A,Orion I

    更新日期:2010-07-19 00:00:00

  • Interfraction positional variation in pancreatic tumors using daily breath-hold cone-beam computed tomography with visual feedback.

    abstract::We assessed interfraction positional variation in pancreatic tumors using daily breath-hold cone-beam computed tomography at end-exhalation (EE) with visual feedback (BH-CBCT). Eleven consecutive patients with pancreatic cancer who underwent BH intensity-modulated radiation therapy with visual feedback were enrolled. ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v16i2.5123

    authors: Nakamura M,Akimoto M,Ono T,Nakamura A,Yano S,Nakata M,Itasaka S,Mizowaki T,Shibuya K,Hiraoka M

    更新日期:2015-03-08 00:00:00

  • On the use of bolus for pacemaker dose measurement and reduction in radiation therapy.

    abstract::Special attention is required in planning and administering radiation therapy to patients with cardiac implantable electronic devices (CIEDs), such as pacemaker and defibrillator. The range of dose to CIEDs that can induce malfunction is large among CIEDs. Clinically significant defects have been reported at dose as l...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12229

    authors: Yan H,Guo F,Zhu D,Stryker S,Trumpore S,Roberts K,Higgins S,Nath R,Chen Z,Liu W

    更新日期:2018-01-01 00:00:00

  • Dose perturbation in the radiotherapy of breast cancer patients implanted with the Magna-Site: a Monte Carlo study.

    abstract::External beam radiation therapy (RT) is often offered to breast cancer patients after surgical mastectomy followed by breast reconstruction with silicone implants. In some cases, the RT is administered while the patient is still implanted with a temporary tissue expander including a high-density metallic port, which i...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v12i2.3295

    authors: Chatzigiannis C,Lymperopoulou G,Sandilos P,Dardoufas C,Yakoumakis E,Georgiou E,Karaiskos P

    更新日期:2011-01-19 00:00:00

  • Preclinical assessment of comfort and secure fit of thermobrachytherapy surface applicator (TBSA) on volunteer subjects.

    abstract::A thermobrachytherapy surface applicator (TBSA) was developed for simultaneous heat and brachytherapy treatment of chest wall (CW) recurrence of breast cancer. The ability to comfortably secure the applicator over the upper torso relative to the CW target throughout treatment is assessed on volunteers. Male and postma...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v13i5.3845

    authors: Arunachalam K,Craciunescu OI,Markewitz EJ,Maccarini PF,Schlorff JL,Stauffer PR

    更新日期:2012-09-06 00:00:00

  • Implementation of full/half bowtie filter models in a commercial treatment planning system for kilovoltage cone-beam CT dose estimations.

    abstract::The purpose of this study was to implement full/half bowtie filter models in a com-mercial treatment planning system (TPS) to calculate kilovoltage (kV) cone-beam CT (CBCT) doses of Varian On-Board Imager (OBI) kV X-ray imaging system. The full/half bowtie filter models were created as compensators in Pinnacle TPS usi...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v17i2.5988

    authors: Kim S,Alaei P

    更新日期:2016-03-08 00:00:00

  • Investigating the feasibility of generating dual-energy CT from one 120-kVp CT scan: a phantom study.

    abstract:INTRODUCTION:This study aimed to investigate the feasibility of generating pseudo dual-energy CT (DECT) from one 120-kVp CT by using convolutional neural network (CNN) to derive additional information for quantitative image analysis through phantom study. METHODS:Dual-energy scans (80/140 kVp) and single-energy scans ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.13148

    authors: Huang WH,Jhan KJ,Yang CC

    更新日期:2020-10-14 00:00:00

  • The accuracy of dynamic wedge dose computation in the ADAC Pinnacle RTP system.

    abstract::The nonphysical wedge is a modality that uses computer-controlled jaw motion to generate wedge-shaped dose distributions. There are Varian enhanced dynamic wedges (EDWs) and Siemens virtual wedges (VWs). We recently commissioned dynamic wedges on both Varian and Siemens LINACs. The beam data, acquired with a Wellhofer...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v5i4.1964

    authors: Shao H,Wu X,Luo C,Crooks A,Bernstein A,Markoe A

    更新日期:2004-10-01 00:00:00

  • Measurement of gantry rotation time in modern ct.

    abstract::The purpose of this study was to develop and evaluate a noninvasive method to assess rotation time in modern commercial computed tomography (CT) systems. The rotation time was measured at a selected nominal rotation time (400 ms) utilizing two types of solid-state detectors: the RTI's CT Dose Profiler (CTDP) and Unfor...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v15i1.4517

    authors: Fukuda A,Lin PJ,Matsubara K,Miyati T

    更新日期:2014-01-06 00:00:00

  • Case study of radiation therapy treatment of a patient with a cardiac ventricular assist device.

    abstract::A patient with a cardiac ventricular assist device (VAD) with computer-controlled driver presented to our department for radiation therapy. The treatment plan was 4500 cGy to the rectum over 25 fractions with 15MV photon beams. All beams avoided the pump and leads. The response to electromagnetic interference (EMI) wa...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v9i4.2851

    authors: Lasher DE,Wojcicka JB,Malcom R,Shears LL

    更新日期:2008-10-29 00:00:00

  • Voxel-based supervised machine learning of peripheral zone prostate cancer using noncontrast multiparametric MRI.

    abstract:PURPOSE:The aim of this study was to develop and assess the performance of supervised machine learning technique to classify magnetic resonance imaging (MRI) voxels as cancerous or noncancerous using noncontrast multiparametric MRI (mp-MRI), comprised of T2-weighted imaging (T2WI), diffusion-weighted imaging (DWI), and...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12992

    authors: Gholizadeh N,Simpson J,Ramadan S,Denham J,Lau P,Siddique S,Dowling J,Welsh J,Chalup S,Greer PB

    更新日期:2020-10-01 00:00:00

  • New adaptive statistical iterative reconstruction ASiR-V: Assessment of noise performance in comparison to ASiR.

    abstract:PURPOSE:To assess the noise characteristics of the new adaptive statistical iterative reconstruction (ASiR-V) in comparison to ASiR. METHODS:A water phantom was acquired with common clinical scanning parameters, at five different levels of CTDIvol . Images were reconstructed with different kernels (STD, SOFT, and BONE...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12253

    authors: De Marco P,Origgi D

    更新日期:2018-03-01 00:00:00

  • Generation and verification of QFix kVue Calypso-compatible couch top model for a dedicated stereotactic linear accelerator with FFF beams.

    abstract::This study details the generation, verification, and implementation of a treatment planning system (TPS) couch top model for patient support system used in conjunction with a dedicated stereotactic linear accelerator. Couch top model was created within the TPS using CT simulation images of the kVue Calpyso-compatible ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v16i4.5441

    authors: Gardner SJ,Gulam M,Song K,Li H,Huang Y,Zhao B,Qin Y,Snyder K,Kim J,Gordon J,Chetty IJ,Wen N

    更新日期:2015-07-08 00:00:00

  • Peer support: A needs assessment for social support from trained peers in response to stress among medical physicists.

    abstract:PURPOSE:Previous studies suggest that within radiation oncology, medical physicists (MP) experience high workloads. Little is known about how MPs use social support (SS) in times of stress. METHODS:In collaboration with the Workgroup on Prevention of Medical Error, the American Association of Physicists in Medicine ad...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12675

    authors: Johnson J,Ford E,Yu J,Buckey C,Fogh S,Evans SB

    更新日期:2019-09-01 00:00:00

  • Method and phantom to study combined effects of in-plane (x,y) and z-axis resolution for 3D CT imaging.

    abstract::Increasingly, the advent of multislice CT scanners, volume CT scanners, and total body spiral acquisition modes has led to the use of Multi Planar Reconstruction and 3D datasets. In considering 3D resolution properties of a CT system it is important to note that both the in-plane (x,y) and z-axis (slice thickness) inf...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v17i5.6294

    authors: Goodenough D,Levy J,Kristinsson S,Fredriksson J,Olafsdottir H,Healy A

    更新日期:2016-09-08 00:00:00

  • Peripheral dose distributions for a linear accelerator equipped with a secondary multileaf collimator and universal wedge.

    abstract::The American Association of Physicists in Medicine Task Group 36 (AAPM TG-36) data can be used to estimate peripheral dose (PD) distributions outside the primary radiation field. However, the report data does not apply to linear accelerators equipped with a multileaf collimator (MLC) and universal wedge (UW). Tertiary...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v3i4.2554

    authors: Mutic S,Esthappan J,Klein EE

    更新日期:2002-10-01 00:00:00

  • A dosimetric comparison of stereotactic body radiation therapy techniques for lung cancer: robotic versus conventional linac-based systems.

    abstract::The aim of this study is to compare the dosimetric characteristics of robotic and conventional linac-based SBRT techniques for lung cancer, and to provide planning guidance for each modality. Eight patients who received linac-based SBRT were retrospectively included in this study. A dose of 60 Gy given in three fracti...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v11i3.3223

    authors: Ding C,Chang CH,Haslam J,Timmerman R,Solberg T

    更新日期:2010-06-29 00:00:00

  • On the sensitivity of TG-119 and IROC credentialing to TPS commissioning errors.

    abstract::We investigate the sensitivity of IMRT commissioning using the TG-119 C-shape phantom and credentialing with the IROC head and neck phantom to treatment planning system commissioning errors. We introduced errors into the various aspects of the commissioning process for a 6X photon energy modeled using the analytical a...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v17i1.5452

    authors: McVicker D,Yin FF,Adamson JD

    更新日期:2016-01-08 00:00:00

  • Understanding the impact of RapidArc therapy delivery errors for prostate cancer.

    abstract::The purpose of this study is to simulate random and systematic RapidArc delivery errors for external beam prostate radiotherapy plans in order to determine the dose sensitivity for each error type. Ten prostate plans were created with a single 360° arc. The DICOM files for these treatment plans were then imported into...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v12i3.3409

    authors: Oliver M,Bush K,Zavgorodni S,Ansbacher W,Beckham WA

    更新日期:2011-05-20 00:00:00

  • Optimal slice thickness for object detection with longitudinal partial volume effects in computed tomography.

    abstract::Longitudinal partial volume effects (z-axial PVE), which occur when an object partly occupies a slice, degrade image resolution and contrast in computed tomography (CT). Z-axial PVE is unavoidable for subslice objects and reduces their contrast according to their fraction contained within the slice. This effect can be...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12005

    authors: Monnin P,Sfameni N,Gianoli A,Ding S

    更新日期:2017-01-01 00:00:00

  • On the selection of gantry and collimator angles for isocenter localization using Winston-Lutz tests.

    abstract::In Winston-Lutz (WL) tests, the isocenter of a linear accelerator (linac) is determined as the intersection of radiation central axes (CAX) from multiple gantry, collimator, and couch angles. It is well known that the CAX can wobble due to mechanical imperfections of the linac. Previous studies suggested that the wobb...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v17i1.5792

    authors: Du W,Johnson JL,Jiang W,Kudchadker RJ

    更新日期:2016-01-08 00:00:00

  • Design and production of 3D printed bolus for electron radiation therapy.

    abstract::This is a proof-of-concept study demonstrating the capacity for modulated electron radiation therapy (MERT) dose distributions using 3D printed bolus. Previous reports have involved bolus design using an electron pencil beam model and fabrication using a milling machine. In this study, an in-house algorithm is present...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v15i4.4831

    authors: Su S,Moran K,Robar JL

    更新日期:2014-07-08 00:00:00

  • Radiation therapy plan checks in a paperless clinic.

    abstract::Traditional quality assurance checks of a patient's radiation therapy plan involve printing out treatment parameters from the treatment planning system and the "record and verify" (R&V) system and visually checking the information for one-to-one correspondence. In a paperless environment, one can automate this process...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v10i1.2905

    authors: Siochi RA,Pennington EC,Waldron TJ,Bayouth JE

    更新日期:2009-01-27 00:00:00

  • Validation of the preconfigured Varian Ethos Acuros XB Beam Model for treatment planning dose calculations: A dosimetric study.

    abstract::Varian (Palo Alto, California, United States) recently released an online adaptation treatment platform, Ethos, which has introduced a new Dose Preview and Automated Plan Generation module despite sharing identical beam data with the existing Halcyon linac. The module incorporates a preconfigured beam model and the Ac...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.13056

    authors: Hu Y,Byrne M,Archibald-Heeren B,Collett N,Liu G,Aland T

    更新日期:2020-12-01 00:00:00

  • In vivo dosimetry and shielding disk alignment verification by EBT3 GAFCHROMIC film in breast IOERT treatment.

    abstract::Intraoperative electron radiation therapy (IOERT) cannot usually benefit, as conventional external radiotherapy, from software systems of treatment planning based on computed tomography and from common dose verify procedures. For this reason, in vivo film dosimetry (IVFD) proves to be an effective methodology to evalu...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v16i1.5065

    authors: Severgnini M,de Denaro M,Bortul M,Vidali C,Beorchia A

    更新日期:2014-01-08 00:00:00

  • Dosimetric verification of inverse planned step and shoot multileaf collimator fields from a commercial treatment planning system.

    abstract::An inverse treatment planning (ITP) module on a commercial treatment planning system (TPS) (Helax AB, Uppsala, Sweden) is being used for an in-house clinical trial for treatment of nasopharyngeal cancer with contralateral parotid sparing. Intensity modulated radiation therapy (IMRT) fields are delivered by step and sh...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v3i2.2580

    authors: MacKenzie MA,Lachaine M,Murray B,Fallone BG,Robinson D,Field GC

    更新日期:2002-04-01 00:00:00

  • Cross verification of independent dose recalculation, log files based, and phantom measurement-based pretreatment quality assurance for volumetric modulated arc therapy.

    abstract::Independent treatment planning system (TPS) check with Mobius3D software, log files based quality assurance (QA) with MobiusFX, and phantom measurement-based QA with ArcCHECK were performed and cross verified for head-and-neck (17 patients), chest (16 patients), and abdominal (19 patients) cancer patients who underwen...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.13036

    authors: Han C,Yi J,Zhu K,Zhou Y,Ai Y,Zheng X,Xie C,Jin X

    更新日期:2020-10-01 00:00:00

  • Development of a treatment planning protocol for prostate treatments using intensity modulated radiotherapy.

    abstract::We have developed a treatment planning protocol for intensity-modulated radiation therapy of the prostate using commercially available inverse planning software. Treatment plans were developed for ten patients using the Corvus version 3.8 planning system, testing various prescription options, including tissue types, d...

    journal_title:Journal of applied clinical medical physics

    pub_type: 临床试验,杂志文章

    doi:10.1120/jacmp.v2i2.2614

    authors: Ezzell GA,Schild SE,Wong WW

    更新日期:2001-04-01 00:00:00

  • Amplitude gating for a coached breathing approach in respiratory gated 10 MV flattening filter-free VMAT delivery.

    abstract::The purpose of this study was to investigate amplitude gating combined with a coached breathing strategy for 10 MV flattening filter-free (FFF) volumetric-modulated arc therapy (VMAT) on the Varian TrueBeam linac. Ten patient plans for VMAT SABR liver were created using the Eclipse treatment planning system (TPS). The...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v16i4.5350

    authors: Viel F,Lee R,Gete E,Duzenli C

    更新日期:2015-07-08 00:00:00