Initial clinical experience with a radiation oncology dedicated open 1.0T MR-simulation.

Abstract:

:The purpose of this study was to describe our experience with 1.0T MR-SIM including characterization, quality assurance (QA) program, and features necessary for treatment planning. Staffing, safety, and patient screening procedures were developed. Utilization of an external laser positioning system (ELPS) and MR-compatible couchtop were illustrated. Spatial and volumetric analyses were conducted between CT-SIM and MR-SIM using a stereotactic QA phantom with known landmarks and volumes. Magnetic field inhomogeneity was determined using phase difference analysis. System-related, in-plane distortion was evaluated and temporal changes were assessed. 3D distortion was characterized for regions of interest (ROIs) 5-20 cm away from isocenter. American College of Radiology (ACR) recommended tests and impact of ELPS on image quality were analyzed. Combined ultrashort echotime Dixon (UTE/Dixon) sequence was evaluated. Amplitude-triggered 4D MRI was implemented using a motion phantom (2-10 phases, ~ 2 cm excursion, 3-5 s periods) and a liver cancer patient. Duty cycle, acquisition time, and excursion were evaluated between maximum intensity projection (MIP) datasets. Less than 2% difference from expected was obtained between CT-SIM and MR-SIM volumes, with a mean distance of < 0.2 mm between landmarks. Magnetic field inhomogeneity was < 2 ppm. 2D distortion was < 2 mm over 28.6-33.6 mm of isocenter. Within 5 cm radius of isocenter, mean 3D geometric distortion was 0.59 ± 0.32 mm (maximum = 1.65 mm) and increased 10-15 cm from isocenter (mean = 1.57 ± 1.06 mm, maximum = 6.26 mm). ELPS interference was within the operating frequency of the scanner and was characterized by line patterns and a reduction in signal-to-noise ratio (4.6-12.6% for TE = 50-150 ms). Image quality checks were within ACR recommendations. UTE/Dixon sequences yielded detectability between bone and air. For 4D MRI, faster breathing periods had higher duty cycles than slow (50.4% (3 s) and 39.4% (5 s), p < 0.001) and ~fourfold acquisition time increase was measured for ten-phase versus two-phase. Superior-inferior object extent was underestimated 8% (6 mm) for two-phase as compared to ten-phase MIPs, although < 2% difference was obtained for ≥ 4 phases. 4D MRI for a patient demonstrated acceptable image quality in ~ 7 min. MR-SIM was integrated into our workflow and QA procedures were developed. Clinical applicability was demonstrated for 4D MRI and UTE imaging to support MR-SIM for single modality treatment planning.

journal_name

J Appl Clin Med Phys

authors

Glide-Hurst CK,Wen N,Hearshen D,Kim J,Pantelic M,Zhao B,Mancell T,Levin K,Movsas B,Chetty IJ,Siddiqui MS

doi

10.1120/jacmp.v16i2.5201

subject

Has Abstract

pub_date

2015-03-08 00:00:00

pages

5201

issue

2

issn

1526-9914

journal_volume

16

pub_type

杂志文章
  • Gamma Knife® icon CBCT offers improved localization workflow for frame-based treatment.

    abstract:OBJECT:The purpose of this study was to compare two methods of stereotactic localization in Gamma Knife treatment planning: cone beam computed tomography (CBCT) or fiducial. While the fiducial method is the traditional method of localization, CBCT is now available for use with the Gamma Knife Icon. This study seeks to ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12745

    authors: Duggar WN,Morris B,Fatemi A,Bonds J,He R,Kanakamedala M,Rey-Dios R,Vijayakumar S,Yang C

    更新日期:2019-11-01 00:00:00

  • Using mean dose rate to compare relative dosimetric efficiency with respect to source type and source change schedules for HDR brachytherapy.

    abstract::Remote afterloading devices used for high-dose-rate (HDR) brachytherapy may be supplied with different sources, and these sources typically have differing initial source strengths. In addition, the proposed frequency for source changes may also vary, depending upon the source type. Dosimetric parameters unique to each...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v14i6.4239

    authors: Davis SD,Parker W,Evans MD

    更新日期:2013-11-04 00:00:00

  • Effect of RTOG breast/chest wall guidelines on dose-volume histogram parameters.

    abstract::Treatment planning for breast cancer has been traditionally based on clinical landmarks. The Radiation Therapy Oncology Group (RTOG) published consensus guidelines on contouring target volumes (TV) for the breast/chest wall and draining lymphatics. The effect of these guidelines on dosimetric parameters in surrounding...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v15i2.4547

    authors: Rudra S,Al-Hallaq HA,Feng C,Chmura SJ,Hasan Y

    更新日期:2014-03-06 00:00:00

  • Impact of grid size on uniform scanning and IMPT plans in XiO treatment planning system for brain cancer.

    abstract::The main purposes of this study are to: 1) evaluate the accuracy of XiO treatment planning system (TPS) for different dose calculation grid size based on head phan-tom measurements in uniform scanning proton therapy (USPT); and 2) compare the dosimetric results for various dose calculation grid sizes based on real com...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v16i5.5510

    authors: Rana S,Zheng Y

    更新日期:2015-09-08 00:00:00

  • Validation of the preconfigured Varian Ethos Acuros XB Beam Model for treatment planning dose calculations: A dosimetric study.

    abstract::Varian (Palo Alto, California, United States) recently released an online adaptation treatment platform, Ethos, which has introduced a new Dose Preview and Automated Plan Generation module despite sharing identical beam data with the existing Halcyon linac. The module incorporates a preconfigured beam model and the Ac...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.13056

    authors: Hu Y,Byrne M,Archibald-Heeren B,Collett N,Liu G,Aland T

    更新日期:2020-12-01 00:00:00

  • Standardized flattening filter free volumetric modulated arc therapy plans based on anteroposterior width for total body irradiation.

    abstract::In this work, the feasibility of using flattening filter free (FFF) beams in volumetric modulated arc therapy (VMAT) total body irradiation (TBI) treatment planning to decrease protracted beam-on times for these treatments was investigated. In addition, a methodology was developed to generate standardized VMAT TBI tre...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12827

    authors: Frederick R,Hudson A,Balogh A,Cao JQ,Pierce G

    更新日期:2020-03-01 00:00:00

  • Mathematical modeling of the optimum pulse structure for safe and effective photo epilation using broadband pulsed light.

    abstract::The objective of this work is the investigation of intense pulsed light (IPL) photoepilation using Monte Carlo simulation to model the effect of the output dosimetry with millisecond exposure used by typical commercial IPL systems. The temporal pulse shape is an important parameter, which may affect the biological tis...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v13i5.3702

    authors: Ash C,Donne K,Daniel G,Town G,Clement M,Valentine R

    更新日期:2012-09-06 00:00:00

  • Dose calculation differences between Monte Carlo and pencil beam depend on the tumor locations and volumes for lung stereotactic body radiation therapy.

    abstract::Stereotactic body radiation therapy (SBRT) has been increasingly used as an efficacious treatment modality for early-stage non-small cell lung cancer. The accuracy of dose calculations is compromised due to the presence of inhomogeneity. For the purpose of a consistent prescription, radiation doses were calculated wit...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v14i2.4011

    authors: Zhuang T,Djemil T,Qi P,Magnelli A,Stephans K,Videtic G,Xia P

    更新日期:2013-03-04 00:00:00

  • Effectiveness of a novel gas-release endorectal balloon in the removal of rectal gas for prostate proton radiation therapy.

    abstract::Endorectal balloons (ERBs) are routinely used in prostate proton radiation therapy to immobilize the prostate and spare the rectal wall. Rectal gas can distend the rectum and displace the prostate even in the presence of ERBs. The purpose of this work was to quantify the effects an ERB with a passive gas release condu...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v13i5.3945

    authors: Wootton LS,Kudchadker RJ,Beddar AS,Lee AK

    更新日期:2012-09-06 00:00:00

  • Evaluation of an electron Monte Carlo dose calculation algorithm for treatment planning.

    abstract::The purpose of this study is to evaluate the accuracy of the electron Monte Carlo (eMC) dose calculation algorithm included in a commercial treatment planning system and compare its performance against an electron pencil beam algorithm. Several tests were performed to explore the system's behavior in simple geometries...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v16i3.4636

    authors: Chamberland E,Beaulieu L,Lachance B

    更新日期:2015-05-08 00:00:00

  • Monte Carlo calculation based on hydrogen composition of the tissue for MV photon radiotherapy.

    abstract::The purpose of this study was to demonstrate that Monte Carlo treatment planning systems require tissue characterization (density and composition) as a function of CT number. A discrete set of tissue classes with a specific composition is introduced. In the current work we demonstrate that, for megavoltage photon radi...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v16i5.5586

    authors: Demol B,Viard R,Reynaert N

    更新日期:2015-09-08 00:00:00

  • Evaluation of offline adaptive planning techniques in image-guided brachytherapy of cervical cancer.

    abstract::Modern three-dimensional image-guided intracavitary high dose rate (HDR) brachytherapy is often used in combination with external beam radiotherapy (EBRT) to manage cervical cancer. Intrafraction motion of critical organs relative to the HDR applicator in the time between the planning CT and treatment delivery can cau...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12462

    authors: Liu H,Kinard J,Maurer J,Shang Q,Vanderstraeten C,Hayes L,Sintay B,Wiant D

    更新日期:2018-11-01 00:00:00

  • Radiation treatment planning and delivery strategies for a pregnant brain tumor patient.

    abstract::The management of a pregnant patient in radiation oncology is an infrequent event requiring careful consideration by both the physician and physicist. The aim of this manuscript was to highlight treatment planning techniques and detail measurements of fetal dose for a pregnant patient recently requiring treatment for ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12262

    authors: Labby ZE,Barraclough B,Bayliss RA,Besemer AE,Dunkerley DAP,Howard SP

    更新日期:2018-09-01 00:00:00

  • Gantry angle determination during arc IMRT: evaluation of a simple EPID-based technique and two commercial inclinometers.

    abstract::The increasing popularity of intensity-modulated arc therapy (IMAT) treatments requires specifically designed linac quality assurance (QA) programs. Gantry angle is one of the parameters that has a major effect on the outcome of IMAT treatments since dose reconstruction for patient-specific QA relies on the gantry ang...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v13i6.3981

    authors: Rowshanfarzad P,Sabet M,O'Connor DJ,McCowan PM,McCurdy BM,Greer PB

    更新日期:2012-11-08 00:00:00

  • Optimization of intra-voxel incoherent motion measurement in diffusion-weighted imaging of breast cancer.

    abstract:PURPOSE:The purpose of this study was to optimize intra-voxel incoherent motion (IVIM) measurement in diffusion-weighted imaging (DWI) of breast cancer by separating perfusion and diffusion effects through the determination of an optimal threshold b-value, thus benign and cancerous breast tissues can be accurately diff...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12065

    authors: Chen W,Zhang J,Long D,Wang Z,Zhu JM

    更新日期:2017-05-01 00:00:00

  • Free-breathing conformal irradiation of pancreatic cancer.

    abstract::The purpose of this study was to assess treatment margins in free-breathing irradiation of pancreatic cancer after bone alignment, and evaluate their impact on conformal radiotherapy. Fifteen patients with adenocarcinoma of the head of the pancreas underwent implantation of single fiducial marker. Intrafraction uncert...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v14i4.4152

    authors: Solla I,Zucca S,Possanzini M,Piras S,Pusceddu C,Porru S,Meleddu G,Farace P

    更新日期:2013-07-08 00:00:00

  • Contour-based lung dose prediction for breast proton therapy.

    abstract:PURPOSE:This study evaluates the feasibility of lung dose prediction based on target contour and patient anatomy for breast patients treated with proton therapy. METHODS:Fifty-two randomly selected patients were included in the cohort, who were treated to 50.4-66.4 Gy(RBE) to the left (36), right (15), or bilateral (1...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章,随机对照试验

    doi:10.1002/acm2.12436

    authors: Zeng C,Sine K,Mah D

    更新日期:2018-11-01 00:00:00

  • Comparison of the KonRad IMRT and XiO treatment planning systems.

    abstract::Reducing the treatment time for IMRT patients is highly desirable. The objective of this work was to evaluate the new clinical Siemens KonRad inverse treatment planning system (TPS) and compare it to the CMS XiO TPS with special emphasis on the segmentation efficiency. For head and neck, liver and prostate cancer pati...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v9i3.2770

    authors: Reitz B,Miften M

    更新日期:2008-07-14 00:00:00

  • An open-source software for monitoring intrafraction motion during external beam radiation therapy based on superimposition of contours of projected ROIs on cine-MV images.

    abstract:PURPOSE:To present an open-source software (https://github.com/CHUSRadOncPhys/FluoMV) for monitoring intrafraction motion that is based on the visualization of superimposed contours of projected region-of-interests from DICOM RTSTRUCT files on cine-MV images acquired and displayed in real-time during radiation therapy ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12940

    authors: Lessard R,Tremblay NM,Plourde MÉ,Guillot M

    更新日期:2020-08-01 00:00:00

  • Distributive quality assurance and delivery of stereotactic ablative radiotherapy treatments amongst beam matched linear accelerators: A feasibility study.

    abstract:PURPOSE:Beam matching occurs on all linacs to some degree and when two are more are matched to each other, patients are able to be transferred between machines. Quality assurance of plans can also be performed "distributively" on any of the matched linacs. The degree to which machines are matched and how this translate...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12567

    authors: Rijken J,Schachenmayr H,Crowe S,Kairn T,Trapp J

    更新日期:2019-04-01 00:00:00

  • Hepatic encephalopathy: a neurochemical, neuroanatomical, and neuropsychological study.

    abstract::Hepatic encephalopathy (HE) is normally diagnosed by neuropsychological (NP) tests, which are not very specific and do not reveal the underlying pathology. Magnetic resonance imaging (MRI) and spectroscopy (MRS) of the brain offer alternative and possibly more specific markers for HE. These methods were applied in con...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v7i1.2151

    authors: Binesh N,Huda A,Thomas MA,Wyckoff N,Bugbee M,Han S,Rasgon N,Davanzo P,Sayre J,Guze B,Martin P,Fawzy F

    更新日期:2006-01-01 00:00:00

  • Electrocardiogram-gated coronary CT angiography dose estimates using ImPACT.

    abstract::The primary study objective was to assess radiation doses using a modified form of the Imaging Performance Assessment of Computed Tomography (CT) scanner (ImPACT) patient dosimetry for cardiac applications on an Aquilion ONE ViSION Edition scanner, including the Ca score, target computed tomography angiography (CTA), ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v17i4.6218

    authors: Kobayashi M,Asada Y,Matsubara K,Suzuki S,Koshida K,Matsunaga Y,Haba T,Kawaguchi A,Toyama H,Kato R

    更新日期:2016-07-08 00:00:00

  • Electrometer offset current due to scattered radiation.

    abstract::Relative dose measurements with small ionization chambers in combination with an electrometer placed in the treatment room ("internal electrometer") show a large dependence on the polarity used. While this was observed previously for percent depth dose curves (PDDs), the effect has not been understood or preventable. ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12458

    authors: Wegener S,Sauer OA

    更新日期:2018-11-01 00:00:00

  • Dose differences between the three dose calculation algorithms in Leksell GammaPlan.

    abstract::The purpose of this study was to evaluate the dose differences introduced by the TMR 10 and the convolution dose calculation algorithms in GammaPlan version 10, as compared to the TMR classic algorithm in the previous versions of GammaPlan. Computed axial tomographic images of a polystyrene phantom and a human head we...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v15i5.4844

    authors: Xu AY,Bhatnagar J,Bednarz G,Niranjan A,Flickinger J,Lunsford LD,Huq MS

    更新日期:2014-09-08 00:00:00

  • Linac-based stereotactic radiosurgery (SRS) in the treatment of refractory trigeminal neuralgia: Detailed description of SRS procedure and reported clinical outcomes.

    abstract:PURPOSE/OBJECTIVES:To present our linac-based SRS procedural technique for medically and/or surgically refractory trigeminal neuralgia (TN) treatment and simultaneously report our clinical outcomes. MATERIALS AND METHODS:Twenty-seven refractory TN patients who were treated with a single fraction of 80 Gy to TN. Treatm...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12057

    authors: Pokhrel D,Sood S,McClinton C,Saleh H,Badkul R,Jiang H,Stepp T,Camarata P,Wang F

    更新日期:2017-03-01 00:00:00

  • Can Hyperpolarized Helium MRI add to radiation planning and follow-up in lung cancer?

    abstract::Locally advanced non-small-cell lung cancer (NSCLC) is a common disease with a low overall survival even with aggressive treatments. Standard imaging (CT and PET/CT) provide no information about normal lung function. We therefore, sought to pilot HeMRI in patients with non-small-cell lung cancer before and after defin...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v12i2.3357

    authors: Allen AM,Albert M,Caglar HB,Zygmanski P,Soto R,Killoran J,Sun Y

    更新日期:2011-01-31 00:00:00

  • Dose deviations induced by respiratory motion for radiotherapy of lung tumors: Impact of CT reconstruction, plan complexity, and fraction size.

    abstract::A thorax phantom was used to assess radiotherapy dose deviations induced by respiratory motion of the target volume. Both intensity modulated and static, non-modulated treatment plans were planned on CT scans of the phantom. The plans were optimized using various CT reconstructions, to investigate whether they had an ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12847

    authors: Sande EPS,Acosta Roa AM,Hellebust TP

    更新日期:2020-04-01 00:00:00

  • A novel method for radiotherapy patient identification using surface imaging.

    abstract::Performing a procedure on the wrong patient or site is one of the greatest errors that can occur in medicine. The addition of automation has been shown to reduce errors in many processes. In this work we explore the use of an automated patient identification process using optical surface imaging for radiotherapy treat...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v17i2.6066

    authors: Wiant DB,Verchick Q,Gates P,Vanderstraeten CL,Maurer JM,Hayes TL,Liu H,Sintay BJ

    更新日期:2016-03-08 00:00:00

  • Automatic calculation of patient size metrics in computed tomography: What level of computational accuracy do we need?

    abstract:OBJECTIVES:To compare the effectiveness of two different patient size metrics based on water equivalent diameter (Dw ), the mid-scan water equivalent diameter Dw_c , and the mean (average) water equivalent diameter in the imaged region, Dw_ave , for automatic detection of accidental changes in computed tomography (CT) ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12240

    authors: Sarmento S,Mendes B,Gouvêa M

    更新日期:2018-01-01 00:00:00

  • Clinical commissioning and use of the Novalis Tx linear accelerator for SRS and SBRT.

    abstract::The purpose of this study was to perform comprehensive measurements and testing of a Novalis Tx linear accelerator, and to develop technical guidelines for com-missioning from the time of acceptance testing to the first clinical treatment. The Novalis Tx (NTX) linear accelerator is equipped with, among other features,...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v13i3.3729

    authors: Kim J,Wen N,Jin JY,Walls N,Kim S,Li H,Ren L,Huang Y,Doemer A,Faber K,Kunkel T,Balawi A,Garbarino K,Levin K,Patel S,Ajlouni M,Miller B,Nurushev T,Huntzinger C,Schulz R,Chetty IJ,Movsas B,Ryu S

    更新日期:2012-05-10 00:00:00