Abstract:
:We investigate the role of adaptive radiation therapy in pediatric patients with diffuse pontine glioma and the impact of steroid-related weight gain on treatment parameters utilizing cone-beam CT. Fifteen patients with diffuse pontine glioma were treated with three-dimensional conformal radiation therapy and enrolled on a daily localization protocol. The median age was 6 years (range: 2-13 years). Patient charts were examined to obtain the prescribed daily dose of dexamethasone and weight. The original treatment plan was recalculated based on the data obtained from the daily cone-beam CT. The changes in target and critical structure doses were calculated using gEUD. Correlations between prescribed dexamethasone, weight gain, source-to-skin distance (SSD) changes and dosimetric changes were investigated. Eleven of the 15 patients gained weight during radiation therapy, with an average gain of 2.2 kg (8.0%). The mean gEUD decreased was 0.57 Gy (range: 0.24-1.4 Gy) for the PTV, and the mean gEUD increase for critical structures was 1.14%. No strong correlations between prescribed dexamethasone doses, weight gain and dosimetric changes were found. Change in SSD vs. dose to PTV was correlated (R² = 0.51). Weight gain and changes to the external surface are apparent in these patients; however, the dosimetric changes to the target and critical structures were small and in most cases did not warrant an adaptive plan. The potential exists for a decrease in target dose in these patients; therefore, they should be monitored to assess for replanning when necessary.
journal_name
J Appl Clin Med Physjournal_title
Journal of applied clinical medical physicsauthors
Beltran C,Sharma S,Merchant TEsubject
Has Abstractpub_date
2011-01-30 00:00:00pages
3421issue
2issn
1526-9914journal_volume
12pub_type
杂志文章abstract::In Winston-Lutz (WL) tests, the isocenter of a linear accelerator (linac) is determined as the intersection of radiation central axes (CAX) from multiple gantry, collimator, and couch angles. It is well known that the CAX can wobble due to mechanical imperfections of the linac. Previous studies suggested that the wobb...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v17i1.5792
更新日期:2016-01-08 00:00:00
abstract:PURPOSE:To investigate the differences between internal target volumes (ITVs) contoured on the simulation 4DCT and daily 4DCBCT images for lung cancer patients treated with stereotactic body radiotherapy (SBRT) and determine the dose delivered on 4D planning technique. METHODS:For nine patients, 4DCBCTs were acquired ...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1002/acm2.13041
更新日期:2020-10-12 00:00:00
abstract::A thorax phantom was used to assess radiotherapy dose deviations induced by respiratory motion of the target volume. Both intensity modulated and static, non-modulated treatment plans were planned on CT scans of the phantom. The plans were optimized using various CT reconstructions, to investigate whether they had an ...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1002/acm2.12847
更新日期:2020-04-01 00:00:00
abstract::This study utilizes process control techniques to identify action limits for TomoTherapy couch positioning quality assurance tests. A test was introduced to monitor accuracy of the applied couch offset detection in the TomoTherapy Hi-Art treatment system using the TQA "Step-Wedge Helical" module and MVCT detector. Ind...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1002/acm2.12136
更新日期:2017-09-01 00:00:00
abstract:PURPOSE:Targeting and tracking of central lung tumors may be feasible on the Elekta MRI-linac (MRL) due to the soft-tissue visualization capabilities of MRI. The purpose of this work is to develop a novel treatment planning methodology to simulate tracking of central lung tumors with the MRL and to quantify the benefit...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1002/acm2.12233
更新日期:2018-01-01 00:00:00
abstract::IMRT QA requires, among other tests, a time-consuming process of measuring the absorbed dose, at least to a point, in a high-dose, low-dose-gradient region. Some clinics use a technique of measuring this dose with all beams delivered at a single gantry angle (collapsed delivery), as opposed to the beams delivered at t...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v15i3.4681
更新日期:2014-05-08 00:00:00
abstract:INTRODUCTION:Aim of this study is to dosimetrically characterize a new inorganic scintillator designed for magnetic resonance-guided radiotherapy (MRgRT) in the presence of 0.35 tesla magnetic field (B). METHODS:The detector was characterized in terms of signal to noise ratio (SNR), reproducibility, dose linearity, an...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1002/acm2.13012
更新日期:2020-09-01 00:00:00
abstract:PURPOSE:Previous studies suggest that within radiation oncology, medical physicists (MP) experience high workloads. Little is known about how MPs use social support (SS) in times of stress. METHODS:In collaboration with the Workgroup on Prevention of Medical Error, the American Association of Physicists in Medicine ad...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1002/acm2.12675
更新日期:2019-09-01 00:00:00
abstract::The study purpose was to develop and validate a quality assurance test for CT automatic exposure control (AEC) systems based on a set of nested polymethylmethacrylate CTDI phantoms. The test phantom was created by offsetting the 16 cm head phantom within the 32 cm body annulus, thus creating a three part phantom. This...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v17i4.6165
更新日期:2016-07-08 00:00:00
abstract::Stereotactic body radiation therapy (SBRT) has been increasingly used as an efficacious treatment modality for early-stage non-small cell lung cancer. The accuracy of dose calculations is compromised due to the presence of inhomogeneity. For the purpose of a consistent prescription, radiation doses were calculated wit...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v14i2.4011
更新日期:2013-03-04 00:00:00
abstract::The purpose of this study was to develop and evaluate filmless quality assurance (QA) tools for helical tomotherapy by using the signals from the on-board megavoltage computed tomography (MVCT) detector and applying a dedicated step-wedge phantom. The step-wedge phantom is a 15 cm long step-like aluminum block positio...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v13i1.3585
更新日期:2012-01-05 00:00:00
abstract:PURPOSE:We conducted this dosimetric analysis to evaluate the feasibility of a multi-center stereotactic body radiation therapy (SBRT) trial for renal cell carcinoma (RCC) using different SBRT platforms. MATERIALS/METHODS:The computed tomography (CT) simulation images of 10 patients with unilateral RCC previously trea...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1002/acm2.12308
更新日期:2018-03-14 00:00:00
abstract::To monitor delivered dose and trigger plan adaptation when deviation becomes unacceptable, a clinical treatment dose (Tx-Dose) reconstruction system based on three-dimensional (3D)/four-dimensional (4D)-cone beam computed tomograpy (CBCT) images was developed and evaluated on various treatment sites, particularly for ...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1002/acm2.12474
更新日期:2018-11-01 00:00:00
abstract::The aim of this study was to compare image noise properties of GE Discovery HD 750 and Toshiba Aquilion ONE. The uniformity section of a Catphan 600 image quality assurance phantom was scanned with both scanners, at different dose levels and with extension rings simulating patients of different sizes. 36 datasets were...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v17i3.5900
更新日期:2016-05-08 00:00:00
abstract:INTRODUCTION:A previous pilot study has demonstrated the feasibility of a novel image-based approach for remote dosimetric auditing of clinical trials. The approach uses a model to convert in-air acquired intensity modulated radiotherapy (IMRT) images to delivered dose inside a virtual phantom. The model was developed ...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1002/acm2.12521
更新日期:2019-01-01 00:00:00
abstract::Recently, specific computed tomography (CT) scanners have been equipped with organ-based tube current modulation (TCM) technology. It is possible that organ-based TCM will replace the conventional dose-reduction technique of reducing the effective milliampere-second. The aim of this study was to determine if organ-bas...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v13i2.3731
更新日期:2012-03-08 00:00:00
abstract::The aim of this study was to assess the performance of a gantry-mounted detector system and a couch set detector system using a systematic multileaf collimator positional error manually introduced for volumetric-modulated arc therapy. Four head and neck and esophagus VMAT plans were evaluated by measurement using an e...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v15i3.4495
更新日期:2014-05-08 00:00:00
abstract::In this work, the feasibility of using flattening filter free (FFF) beams in volumetric modulated arc therapy (VMAT) total body irradiation (TBI) treatment planning to decrease protracted beam-on times for these treatments was investigated. In addition, a methodology was developed to generate standardized VMAT TBI tre...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1002/acm2.12827
更新日期:2020-03-01 00:00:00
abstract::In order to locate lung tumors on kV projection images without internal markers, digitally reconstructed radiographs (DRRs) are created and compared with projection images. However, lung tumors always move due to respiration and their locations change on projection images while they are static on DRRs. In addition, gl...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v16i3.5200
更新日期:2015-05-08 00:00:00
abstract::MIM Symphony is a recently introduced low-dose-rate prostate brachytherapy treatment planning system (TPS). We evaluated the dosimetric and planning accuracy of this new TPS compared to the universally used VariSeed TPS. For dosimetric evaluation of the MIM Symphony version 5.4 TPS, we compared dose calculations from ...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v16i5.5057
更新日期:2015-09-08 00:00:00
abstract::Shewhart control charts have previously been suggested as a process control tool for use in routine linear accelerator (linac) output verifications. However, a comprehensive approach to process control has not been investigated for linac output verifications. The purpose of this work is to investigate a comprehensive ...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v14i1.4032
更新日期:2013-01-07 00:00:00
abstract::The purpose of this study was to describe our experience with 1.0T MR-SIM including characterization, quality assurance (QA) program, and features necessary for treatment planning. Staffing, safety, and patient screening procedures were developed. Utilization of an external laser positioning system (ELPS) and MR-compa...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v16i2.5201
更新日期:2015-03-08 00:00:00
abstract:PURPOSE:The purpose of this study was to optimize intra-voxel incoherent motion (IVIM) measurement in diffusion-weighted imaging (DWI) of breast cancer by separating perfusion and diffusion effects through the determination of an optimal threshold b-value, thus benign and cancerous breast tissues can be accurately diff...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1002/acm2.12065
更新日期:2017-05-01 00:00:00
abstract::The purpose of this work is to prospectively assess the setup accuracy that can be achieved with a stereotactic body localizer (SBL) in immobilizing patients for stereotactic intensity-modulated radiotherapy (IMRT) for prostate cancer. By quantifying this important factor and target mobility in the SBL, we expect to p...
journal_title:Journal of applied clinical medical physics
pub_type: 临床试验,杂志文章
doi:10.1120/jacmp.v5i2.1947
更新日期:2004-04-01 00:00:00
abstract::The purpose of this study was to assess treatment margins in free-breathing irradiation of pancreatic cancer after bone alignment, and evaluate their impact on conformal radiotherapy. Fifteen patients with adenocarcinoma of the head of the pancreas underwent implantation of single fiducial marker. Intrafraction uncert...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v14i4.4152
更新日期:2013-07-08 00:00:00
abstract::The primary study objective was to assess radiation doses using a modified form of the Imaging Performance Assessment of Computed Tomography (CT) scanner (ImPACT) patient dosimetry for cardiac applications on an Aquilion ONE ViSION Edition scanner, including the Ca score, target computed tomography angiography (CTA), ...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v17i4.6218
更新日期:2016-07-08 00:00:00
abstract::We have investigated the combined effect of tissue heterogeneity and its variation associated with geometric error in stereotactic body radiotherapy (SBRT) for lung cancer. The treatment plans for eight lung cancer patients were calculated using effective path length (EPL) correction and Monte Carlo (MC) algorithms, w...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v16i5.5397
更新日期:2015-09-08 00:00:00
abstract::We conducted a metrological evaluation of the dosimetric impact due to the polysulfone cap used with the Fletcher-Williamson (FW) colpostat for 192Ir high-dose rate and pulsed-dose rate intracavitary brachytherapy using Monte Carlo simulations. Polysulfone caps with diameter of 30 mm, 25 mm, 20 mm, and 16 mm (mini-ovo...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v11i1.3146
更新日期:2010-01-28 00:00:00
abstract::Intraoperative electron radiation therapy (IOERT) cannot usually benefit, as conventional external radiotherapy, from software systems of treatment planning based on computed tomography and from common dose verify procedures. For this reason, in vivo film dosimetry (IVFD) proves to be an effective methodology to evalu...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v16i1.5065
更新日期:2014-01-08 00:00:00
abstract::Studies have shown that source dwells within Varian's HDR CT/MR compatible ring applicators can deviate from intended positions by several millimeters. Quantifying this offset is an important part of commissioning. The aims of this study were to: 1) determine the reproducibility of the offset, 2) study the interobserv...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v12i4.3447
更新日期:2011-11-15 00:00:00