Chaotic dynamics in circulation with Tohoku University vibrating flow pump.

Abstract:

:For the development of a totally implantable ventricular assist system (VAS), we have been developing the vibrating flow pump (VFP), which can generate oscillated blood flow with a relative high frequency (10-50 Hz) for a totally implantable system. In this study, the effects of left ventricular assistance with this unique oscillated blood flow were analyzed by the use of nonlinear mathematics for evaluation as the whole circulatory regulatory system, not as the decomposed parts of the system. Left heart bypasses using the VFP from the left atrium to the descending aorta were performed in chronic animal experiments using healthy adult goats. The ECG, arterial blood pressure, VFP pump flow, and the flow of the descending aorta were recorded in the data recorder during awake conditions and analyzed in a personal computer system through an A-D convertor. By the use of nonlinear mathematics, time series data were embedded into the phase space, the Lyapunov numerical method, fractal dimension analysis, and power spectrum analysis were performed to evaluate nonlinear dynamics. During left ventricular assistance with the VFP, Mayer wave fluctuations were decreased in the power spectrum, the fractal dimension of the hemodynamics was significantly decreased, and peripheral vascular resistance was significantly decreased. These results suggest that nonlinear dynamics, which mediate the cardiovascular dynamics, may be affected during left ventricular (LV) bypass with oscillated flow. The decreased power of the Mayer wave in the spectrum caused the limit cycle attractor of the hemodynamics and decreased peripheral resistance. Decreased sympathetic discharges may be the origin of the decreased Mayer wave and fractal dimension. These nonlinear dynamic analyses may be useful to design optimal VAS control.

journal_name

Artif Organs

journal_title

Artificial organs

authors

Nitta S,Yambe T,Kobayashi S,Hashimoto H,Yoshizawa M,Mastuki H,Tabayashi K,Takeda H

doi

10.1046/j.1525-1594.1999.06288.x

subject

Has Abstract

pub_date

1999-01-01 00:00:00

pages

119-23

issue

1

eissn

0160-564X

issn

1525-1594

journal_volume

23

pub_type

杂志文章
  • Combination of inhaled nitric oxide therapy and inverse ratio ventilation in patients with sepsis-associated acute respiratory distress syndrome.

    abstract::Inverse ratio ventilation (IRV) is a ventilatory technique that uses an inspiratory to expiratory ratio (I:E) greater than 1:1. We studied the effects of mechanical ventilation with an I:E of 1:3, 1:1, and 2:1 on arterial oxygenation in 10 patients with sepsis-associated acute respiratory distress syndrome (ARDS). At ...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:

    authors: Okamoto K,Kukita I,Hamaguchi M,Kikuta K,Matsuda K,Motoyama T

    更新日期:2000-11-01 00:00:00

  • Potential mechanisms for muscle-powered cardiac support.

    abstract::Biomechanical actuation of an implanted ventricular assist device (VAD) is an attractive means of providing long-term circulatory support. Studies show that energy from electrically stimulated skeletal muscle can, in principle, be used to provide tether-free cardiac assistance without the need for percutaneous driveli...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2010.01170.x

    authors: Trumble DR

    更新日期:2011-07-01 00:00:00

  • Transient rise in serum soluble Fas (APO-1/CD95) in patients undergoing cardiac surgery.

    abstract::The Fas molecule, also designated APO-1/CD95, belongs to the tumor necrosis factor (TNF) receptor family. It is a widely expressed membrane-anchored protein that induces apoptosis by Fas/Fas ligand (Fas-L) mediation. It was reported that Fas-mediated apoptosis plays an important role in regulation of the immune system...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2000.06591.x

    authors: Kawahito K,Misawa Y,Fuse K

    更新日期:2000-08-01 00:00:00

  • Assessment of total hip arthroplasty by means of computed tomography 3D models and fracture risk evaluation.

    abstract::Total hip arthroplasty (THA) can be achieved by using a cemented or noncemented prosthesis. Besides patient's age, weight, and other clinical signs, the evaluation of the quality of the bones is a crucial parameter on which orthopedic surgeons base the choice between cemented and noncemented THA. Although bone density...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12033

    authors: Gargiulo P,Pétursson T,Magnússon B,Bifulco P,Cesarelli M,Izzo GM,Magnúsdóttir G,Halldórsson G,Ludvigsdóttir GK,Tribel J,Jónsson H Jr

    更新日期:2013-06-01 00:00:00

  • Differences in intravenous and subcutaneous application of recombinant human erythropoietin: a multicenter trial.

    abstract::The aims of this clinical study were to compare the maintenance doses for intravenous (i.v.) and subcutaneous (SC) administration of recombinant human erythropoietin (rhEPO) and to investigate whether there is any difference in the increase of the packed cellular volume (PCV) per week under i.v. and SC administration ...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章,多中心研究,随机对照试验

    doi:10.1111/j.1525-1594.1994.tb03378.x

    authors: Schaller R,Sperschneider H,Thieler H,Dutz W,Hans S,Voigt D,Marx M,Engelmann J,Schöter KH,Scigalla P

    更新日期:1994-08-01 00:00:00

  • Elective decompression of the left ventricle in pediatric patients may reduce the duration of venoarterial extracorporeal membrane oxygenation.

    abstract::We aimed to determine the effect of elective left heart decompression at the time of initiation of central venoarterial extracorporeal membrane oxygenation (VA ECMO) on VA ECMO duration and clinical outcomes in children in a single tertiary ECMO referral center with a large pediatric population from a national referra...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12390

    authors: Hacking DF,Best D,d'Udekem Y,Brizard CP,Konstantinov IE,Millar J,Butt W

    更新日期:2015-04-01 00:00:00

  • Prediction of mechanical hemolysis in medical devices via a Lagrangian strain-based multiscale model.

    abstract::This work introduces a new Lagrangian strain-based model to predict the shear-induced hemolysis in biomedical devices. Current computational models for device-induced hemolysis usually utilize empirical fitting of the released free hemoglobin (Hb) in plasma from damaged red blood cells (RBCs). These empirical correlat...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13663

    authors: Nikfar M,Razizadeh M,Zhang J,Paul R,Wu ZJ,Liu Y

    更新日期:2020-08-01 00:00:00

  • Assessment of skeletal muscle ventricle tissue blood flow using positron emission tomography.

    abstract::In this pilot study, we assessed the feasibility of using positron emission tomography (PET) imaging for in vivo measurement of skeletal muscle ventricle (SMV) tissue blood flow. In 4 dogs, with SMVs prepared from their latissimus dorsi muscle, we quantified SMV tissue blood flow by PET and related it to the tissue fl...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:

    authors: Singh TP,Greer K,Muzik O,Hammond RL,Stephenson LW,Di Carli MF

    更新日期:2001-04-01 00:00:00

  • Is low-intensity anticoagulant therapy possible with an open pivot valve?: analysis of its development.

    abstract::In 1976, the authors became the codevelopers of the first successful bileaflet heart valve which has become the standard in valvular surgery. However, there still remains a significant rate of thromboembolism and thrombosis which can be attributed to the inherent design of cavities in the pivot area. These cavities co...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2002.06999.x

    authors: Nicoloff DM,Friedberg HD,Villafaña MA

    更新日期:2002-05-01 00:00:00

  • Engineering of vascular grafts with genetically modified bone marrow mesenchymal stem cells on poly (propylene carbonate) graft.

    abstract::Bone marrow mesenchymal stem cells (MSCs) have demonstrated their pluripotency to differentiate into different cell lineages and may be an alternative cell source for vascular tissue engineering. The objective of this study is to create small diameter vessels by seeding and culture of genetically modified MSCs onto a ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2006.00322.x

    authors: Zhang J,Qi H,Wang H,Hu P,Ou L,Guo S,Li J,Che Y,Yu Y,Kong D

    更新日期:2006-12-01 00:00:00

  • Paracorporeal artificial heart in postoperative heart failure.

    abstract::A pneumatically driven artificial heart with a tubular silicone rubber membrane and disc valves was used for functional heart replacement in the paracorporeal mode. A fluidic drive system allows adjustment of the heart rate, positive and negative pressures and systole/diastole ratio. Since August, 1977, the artificial...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1978.tb03465.x

    authors: Turina MT,Bosio R,Senning A

    更新日期:1978-08-01 00:00:00

  • The role of PI3K/Akt signaling pathway in non-physiological shear stress-induced platelet activation.

    abstract::The PI3K/Akt signaling pathway has been implicated in playing an important role in platelet activation during hemostasis and thrombosis involving platelet-matrix interaction and platelet aggregation. Its role in non-physiological shear stress (NPSS)-induced platelet activation relevant to high-shear blood contacting m...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13465

    authors: Chen Z,Li T,Kareem K,Tran D,Griffith BP,Wu ZJ

    更新日期:2019-09-01 00:00:00

  • Biological evaluation of liposome-encapsulated hemoglobin surface-modified with a novel PEGylated nonphospholipid amphiphile.

    abstract::Traumatic injury is often associated with hemorrhagic shock. Liposome-encapsulated hemoglobin (LEH) is being developed as an artificial oxygen carrier to address post-hemorrhage oxygen and volume deficit. Here, we report a new composition of LEH based on the use of polyethylene glycol (PEG2K ) conjugated with nonphosp...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12304

    authors: Yadav VR,Nag O,Awasthi V

    更新日期:2014-08-01 00:00:00

  • Hemodynamic Evaluation of a Biological and Mechanical Aortic Valve Prosthesis Using Patient-Specific MRI-Based CFD.

    abstract::Modeling different treatment options before a procedure is performed is a promising approach for surgical decision making and patient care in heart valve disease. This study investigated the hemodynamic impact of different prostheses through patient-specific MRI-based CFD simulations. Ten time-resolved MRI data sets w...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12955

    authors: Hellmeier F,Nordmeyer S,Yevtushenko P,Bruening J,Berger F,Kuehne T,Goubergrits L,Kelm M

    更新日期:2018-01-01 00:00:00

  • Cell exclusion in couette flow: evaluation through flow visualization and mechanical forces.

    abstract::Cell exclusion is the phenomenon whereby the hematocrit and viscosity of blood decrease in areas of high stress. While this is well known in naturally occurring Poiseuille flow in the human body, it has never previously been shown in Couette flow, which occurs in implantable devices including blood pumps. The high-she...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2012.01561.x

    authors: Leslie LJ,Marshall LJ,Devitt A,Hilton A,Tansley GD

    更新日期:2013-03-01 00:00:00

  • Miniaturization of a magnetically levitated axial flow blood pump.

    abstract::This article introduces a unique miniaturization process of a magnetically levitated axial flow blood pump from a functional prototype to a pump suitable for animal trials. Through COMSOL three-dimensional finite element analysis and experimental verification, the hybrid magnetic bearings of the pump have been miniatu...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2010.01077.x

    authors: Cheng S,Olles MW,Olsen DB,Joyce LD,Day SW

    更新日期:2010-10-01 00:00:00

  • Performance of baffled bubble blood oxygenators.

    abstract::Bubble blood oxygenators equipped with baffles of various types in the oxygenating column were studied. The rate of hemolysis, the volumetric coefficient for oxygen absorption into blood, and the fractional gas holdup were found to be affected mainly by the superficial gas velocity. When compared with the conventional...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1979.tb01032.x

    authors: Ohshima N,Yoshido F

    更新日期:1979-05-01 00:00:00

  • Effects of continuous-flow left ventricular assist devices on cerebral hemodynamics.

    abstract::Continuous-flow left ventricular assist devices (LVADs) reduce peak systolic flow, increase diastolic flow, and eliminate pulsatility of circulation. Altered blood flow may lead to a change in end-organ perfusion. Analysis of the flow dynamics of the arteries of end organs, such as the brain, may indicate whether an o...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13616

    authors: Karahan M,Kocabeyoglu SS,Kervan U,Sert DE,Aygun E,Tola M,Demirkan B,Mungan S,Kursun O,Catav Z,Pac M

    更新日期:2020-05-01 00:00:00

  • Vascular access for continuous arteriovenous hemofiltration in infants and young children.

    abstract::The blood flow through the hemofilter device is the key point for ultrafiltrate production during continuous arteriovenous hemofiltration. It mainly depends on arteriovenous pressure gradient and vascular access, which is the major problem for arteriovenous hemofiltration in infants and small children. In infants, we ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1988.tb01518.x

    authors: Zobel G,Trop M,Beitzke A,Ring E

    更新日期:1988-02-01 00:00:00

  • Usability and safety of ventricular assist devices: human factors and design aspects.

    abstract::The purpose of this study was the investigation of the usability and ergonomics of ventricular assist devices (VADs) in everyday usage. Patients with four different VAD types were observed. After implantation, instruction, and discharge from the hospital, the patients returned on a regular basis to the outpatient clin...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00844.x

    authors: Geidl L,Zrunek P,Deckert Z,Zimpfer D,Sandner S,Wieselthaler G,Schima H

    更新日期:2009-09-01 00:00:00

  • A reduced priming system.

    abstract::Cardiopulmonary bypass (CPB), an integral part of valve surgery, is known to cause hemodilution, which can lead to a need for blood transfusion as well as a systemic inflammatory reaction. Our aim was to evaluate a reduced priming (RP) system for CPB with regard to clinical outcomes in patients undergoing valve surger...

    journal_title:Artificial organs

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/j.1525-1594.2006.00275.x

    authors: Sato K,Namura O,Sogawa M,Shimada K,Tosaka Y,Hayashi J

    更新日期:2006-08-01 00:00:00

  • Improved retention of endothelial cells seeded on polyurethane small-diameter vascular grafts modified by a recombinant RGD-containing protein.

    abstract::Sponge-type small-diameter vascular grafts were fabricated from a medical-grade polyurethane, Pellethane 2363-80A, by utilization of a salt casting technique. The grafts were compliance matched with a storage modulus of 0.53 +/- 0.08 MPa. The luminal surface of grafts was modified with a thin layer ( approximately 40 ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2003.07141.x

    authors: Hsu SH,Sun SH,Chen DC

    更新日期:2003-12-01 00:00:00

  • Donkey pericardium compares favorably with commercial xenopericardia used in the manufacture of transcatheter heart valves.

    abstract::Transcatheter aortic valve implantation (TAVI) has gained considerable acceptance in the past decade due to its lower risks than conventional open-heart surgery. However, the deformation and delamination of the leaflets during the crimping procedure have raised questions about the durability and long-term serviceabili...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13503

    authors: Mao J,Rassoli A,Tong Y,Rouse EN,Le-Bel G,How D,Germain L,Fatouraee N,Zhang Z,Reed RR,Guidoin R

    更新日期:2019-10-01 00:00:00

  • Ripple reduction control of the undulation pump total artificial heart.

    abstract::An undulation pump total artificial heart (UPTAH) in which the revolutions of the motor are converted to undulation motion of a disk has been developed. In an experiment, a goat using the UPTAH survived for 54 days. However, a large ripple was observed in the device's output pressure and flow waveform. In calculating ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2002.06798.x

    authors: Saito I,Chinzei T,Mochizuki S,Abe Y,Isoyama T,Iwasaki K,Suzuki T,Karita T,Ono T,Kouno A,Ishimaru M,Baba A,Ozeki T,Tohyama T,Kobayashi Si S,Imachi K

    更新日期:2002-01-01 00:00:00

  • Pump power loss and heat generation in a pivot bearing-supported Gyro centrifugal pump (C1E3).

    abstract::Pump power loss is defined as input power that is not used for the output work of the pump. Less pump power loss means a higher pump efficiency. A common opinion is that the pump power loss is closely related to heat generation of the pump, which may affect not only the endurance of pump materials, but also blood dama...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1996.tb04542.x

    authors: Takami Y,Nakazawa T,Makinouchi K,Glueck J,Ohara Y,Benkowski RJ,Nosé Y

    更新日期:1996-07-01 00:00:00

  • Effects of customized bicarbonate buffered solutions for continuous renal replacement therapies on polymorphonuclear leukocytes function and viability.

    abstract::It has previously been shown that the mixture of bicarbonate and calcium in the solutions used for continuous renal replacement therapy led to crystallization and significant changes in calcium concentration and pH. The aim of this study was to investigate the impact of bicarbonate/calcium and lactate/calcium solution...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2004.07284.x

    authors: Maccariello E,Dalboni MA,Draibe SA,Rocha E,Pavão dos Santos OF,Santos B,Cendoroglo M

    更新日期:2004-06-01 00:00:00

  • From wooden limbs to biomaterial organs: the ethics of organ replacement and artificial organs.

    abstract::This paper discussed issues of ethical assessment and moral concern associated with organ replacement and physical enhancement: research, allocation, organ donation, artificial organs, xenografts, biomaterials, and neuromaterials. While emphasizing the medical and moral benefits over associated risks, it calls for a b...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1995.tb02362.x

    authors: Kielstein R,Sass HM

    更新日期:1995-05-01 00:00:00

  • Measurement of the closing behavior of the björk-shiley monoleaflet mechanical heart valve with an electrohydraulic total artificial heart.

    abstract::When cavitation occurs near a material surface of a mechanical heart valve (MHV), pits on the surface of the MHV and hemolysis are caused. Therefore, it is very important to investigate the possibility of the occurrence of cavitation in an MHV. To study the possibility of cavitation occurrence in a 25 mm Björk-Shiley ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2003.06981.x

    authors: Lee H,Tsukiya T,Homma A,Taenaka Y,Tatsumi E,Takano H

    更新日期:2003-08-01 00:00:00

  • Effect of a balanced biventricular bypass system on left ventricular energies.

    abstract::Left dominant biventricular failure is a common type of heart failure after cardiac surgery. We developed a biventricular bypass (BVB) system for treatment of postcardiotomy ventricular failure, and we previously reported that the clinical results of the BVB system were superior to those obtained with venoarterial byp...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1998.06015.x

    authors: Kodera K,Kitamura M,Shibuya M,Kurihara H,Koyanagi H

    更新日期:1998-09-01 00:00:00

  • Hemoperfusion and DNA synthesis in the rat liver. Part I: the effect of hemoperfusion on the rate of DNA synthesis.

    abstract::An investigation has been made into whether charcoal hemoperfusion stimulates a hyperplastic response in the liver of the normal rat. Animals underwent hemoperfusion over Norit RBX1 (Strathclyde, Glasgow, U.K.) charcoal granules using a technique which allowed perfusion in the unrestrained and conscious state. Control...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1982.tb04080.x

    authors: Ryan CJ,Courtney JM,Wood CB,Blumgart LH

    更新日期:1982-05-01 00:00:00