Abstract:
:In several applications, MRI is used to monitor the time behavior of the signal in an organ of interest; e.g., signal evolution because of physiological motion, activation, or contrast-agent accumulation. Dynamic applications involve acquiring data in a k-t space, which contains both temporal and spatial information. It is shown here that in some dynamic applications, the t axis of k-t space is not densely filled with information. A method is introduced that can transfer information from the k axes to the t axis, allowing a denser, smaller k-t space to be acquired, and leading to significant reductions in the acquisition time of the temporal frames. Results are presented for cardiac-triggered imaging and functional MRI (fMRI), and are compared with data obtained in a conventional way. The temporal resolution was increased by nearly a factor of two in the cardiac-triggered study, and by as much as a factor of eight in the fMRI study. This increase allowed the acquisition of fMRI activation maps, even when the acquisition time for a single full time frame was actually longer than the paradigm cycle period itself. The new method can be used to significantly reduce the acquisition time of the individual temporal frames in certain dynamic studies. This can be used, for example, to increase the temporal or spatial resolution, increase the spatial coverage, decrease the total imaging time, or alter sequence parameters e.g., repetition time (TR) and echo time (TE) and thereby alter contrast. Magn Reson Med 42:813-828, 1999.
journal_name
Magn Reson Medjournal_title
Magnetic resonance in medicineauthors
Madore B,Glover GH,Pelc NJdoi
10.1002/(sici)1522-2594(199911)42:5<813::aid-mrm1>subject
Has Abstractpub_date
1999-11-01 00:00:00pages
813-28issue
5eissn
0740-3194issn
1522-2594pii
10.1002/(SICI)1522-2594(199911)42:5<813::AID-MRM1>journal_volume
42pub_type
杂志文章abstract::Multiple-slice perfusion imaging by continuous arterial spin labeling (CASL) is made possible by amplitude modulation (AM) of the labeling RF pulse, but perfusion sensitivity is reduced relative to the single-slice technique. A computer model of the Bloch equations for velocity driven adiabatic fast passage was develo...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.20604
更新日期:2005-09-01 00:00:00
abstract::Frequency-modulated (FM) pulses have practical advantages for spin-echo experiments, such as the ability to produce a broadband pi rotation, with an inhomogeneous radiofrequency (RF) field. However, such use leads to a nonlinear phase of the transverse magnetization, which is why FM pulses like the hyperbolic secant (...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.21822
更新日期:2009-01-01 00:00:00
abstract::The prebolus technique allows one to quantify perfusion in the human heart with a low variability by means of MRI. In this study the prebolus technique was used to determine quantitative perfusion values in the human heart under adenosine stress and to measure the myocardial perfusion reserve (MPR). Twelve healthy vol...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.21020
更新日期:2006-10-01 00:00:00
abstract:PURPOSE:The aim of this work was to quantify the extent of lipid-rich necrotic core (LRNC) and intraplaque hemorrhage (IPH) in atherosclerotic plaques. METHODS:Patients scheduled for carotid endarterectomy underwent four-point Dixon and T1-weighted magnetic resonance imaging (MRI) at 3 Tesla. Fat and R2* maps were gen...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26359
更新日期:2017-07-01 00:00:00
abstract::Spin-echo images of 10 myocardial infarcts in nine mini-pigs were obtained at 30 h, 3 days, and approximately 10 days postinfarction. Infarcts were not detected at all at 30 h in five out of five cases examined. At 3 days postembolization (six cases) one infarct was certainly detected, whilst at 10 days (nine cases) a...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910050302
更新日期:1987-09-01 00:00:00
abstract::Breathing motion is one of the main sources of artifacts in MRI acquisitions that can severely impair diagnosis. In MRI with continuously moving table, the application of common motion compensation approaches such as breath holding or the synchronization of the measurement with the breathing motion can be problematic....
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.22162
更新日期:2010-03-01 00:00:00
abstract::A method for volume selective proton spectroscopy is presented based on a multiecho sequence with short refocusing interval tcp. It is demonstrated, that by appropriate choice of tcp on the order of 4-6 ms, signals from overlapping multiplets like the glutamine and glutamate (Glu/Gln) resonances in spectra of the huma...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910370603
更新日期:1997-06-01 00:00:00
abstract:PURPOSE:To investigate whether saturation using existing methods developed for 3T imaging is feasible for clinical perfusion imaging at 7T, and to propose a new design of saturation pulse train for first-pass myocardial perfusion imaging at 7T. METHODS:The new design of saturation pulse train consists of four hyperbol...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.25262
更新日期:2015-04-01 00:00:00
abstract:PURPOSE:Anesthesia is necessary for most animal studies requiring invasive procedures. It is well documented that various types of anesthesia modulate a wide variety of important metabolic and functional processes in the body, and as such, represent a potential limitation in the study design. In the present study, we a...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.27165
更新日期:2018-11-01 00:00:00
abstract::Fe(III)meso-tetra(4-sulfonatophenyl)porphine (Fe-TPPS4) has been investigated as a potential pH-sensitive nuclear magnetic resonance (NMR) proton image contrast agent. Relaxation rates (1/T1 and 1/T2) of water protons were measured as a function of pH and concentration of Fe-TPPS4 in phosphate-buffered isotonic saline...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910050313
更新日期:1987-09-01 00:00:00
abstract::The previously observed improvement in spectral resolution of tissue proton NMR with high-resolution magic angle spinning (HRMAS) was speculated to be due largely to freeze-thawing artifacts resulting from tissue storage. In this study, 12 human prostate samples were analyzed on a 14.1T spectrometer at 3 degrees C, wi...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.10645
更新日期:2003-12-01 00:00:00
abstract::The authors addressed the hypothesis that interactions with creatine kinase (CK) play a role in the off-resonance magnetization transfer (MT) effect of creatine in skeletal muscle. Toward that aim, (1)H MT studies were done on hindleg muscle in wild-type mice and in transgenic mice, lacking cytoplasmic CK and/or mitoc...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/(sici)1522-2594(200005)43:5<657::aid-mrm7>
更新日期:2000-05-01 00:00:00
abstract::In spin echo imaging, magnetization is assigned to a location defined by its frequency of rotation. In the presence of a static magnetic field inhomogeneity, however, this location does not correspond to the true location of the magnetization. This paper describes a magnetic resonance imaging technique called phase co...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910330407
更新日期:1995-04-01 00:00:00
abstract::When developing new techniques for NMR imaging and in vivo spectroscopy it is a major advantage to be able to calculate the magnetization slice profiles, at any point during a pulse sequence in the presence of a field gradient. While this has frequently been done by treating the problem as a number of discrete resonan...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910050511
更新日期:1987-11-01 00:00:00
abstract::Hyperpolarized gases ((129)Xe and (3)He) are being used increasingly in both MRI and NMR spectroscopy studies. However, it has been shown that carrier agents are required to preserve the long relaxation times of gases in biological fluids. Optimized gas transport can be achieved through controlled T(1) and T(2) measur...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.10476
更新日期:2003-06-01 00:00:00
abstract::MRI evaluations of intramyocardial hemorrhage in acute infarction have relied on T(2) and T(2)(*) shortening only. We propose a more comprehensive evaluation of hemorrhagic infarction based on the concept that fluctuations in T(2) and T(1) relaxation in acute reperfused infarction will reflect transient edema and hemo...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.21079
更新日期:2006-12-01 00:00:00
abstract:PURPOSE:To assess the use of image registration for correcting respiratory motion in free breathing lung T1 mapping acquisition in patients with idiopathic pulmonary fibrosis (IPF). THEORY AND METHODS:The method presented used image registration to synthetic images during postprocessing to remove respiratory motion. S...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.28342
更新日期:2020-12-01 00:00:00
abstract::Black blood MRI is an attractive tool for monitoring normal and pathological wall thickening; however, limited spatial resolutions can conspire with complex vascular geometries to distort the appearance of the wall in ways hitherto unclear. To elucidate this, a thin-walled cylinder model was developed to predict the c...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.21758
更新日期:2008-11-01 00:00:00
abstract::This study presents the detection of [2-(13)C]glucose metabolism in the carboxylic/amide region in the human brain, and demonstrates that the cerebral metabolism of [2-(13)C]glucose can be studied in human subjects in the presence of severe hardware constraints of widely available 3 T clinical scanners and with low-po...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.22044
更新日期:2009-09-01 00:00:00
abstract:PURPOSE:Phosphorus spectroscopy (31 P-MRS) is a proven method to probe cardiac energetics. Studies typically report the phosphocreatine (PCr) to adenosine triphosphate (ATP) ratio. We focus on another 31 P signal: inorganic phosphate (Pi), whose chemical shift allows computation of myocardial pH, with Pi/PCr providing ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.28494
更新日期:2021-03-01 00:00:00
abstract::Three-dimensional spatial-spectral radiofrequency pulses using a stack-of-spirals trajectory can achieve two-dimensional spatial localization and one-dimensional spectral selection simultaneously. These pulses are useful, for example, in reduced field-of-view applications that also require frequency specificity such a...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.22209
更新日期:2010-03-01 00:00:00
abstract:PURPOSE:To determine whether neurochemical concentrations obtained at two MRI sites using clinical 3T scanners can be pooled when a highly optimized, nonvendor short-echo, single-voxel proton MRS pulse sequence is used in conjunction with identical calibration and quantification procedures. METHODS:A modified semi-LAS...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.25295
更新日期:2015-05-01 00:00:00
abstract::MnCl(2) was injected intrathecally through the cisterna magna in rats, allowing infusion of divalent manganese ions (Mn(++)) into the CSF space and thence into the brain, without breaking the blood-brain barrier (BBB). Mn(++) uptake and washout dynamics in the brain were measured by serial T(1)-weighted MRI and EPI T(...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.20047
更新日期:2004-05-01 00:00:00
abstract::A multiple quantum filter strategy is presented for spectrally discriminating metabolites with strongly coupled spins from those whose spins are either uncoupled or weakly coupled. The strategy also includes a means for selectively suppressing the background multiplets of metabolites that also have strongly coupled sp...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.10697
更新日期:2004-02-01 00:00:00
abstract:PURPOSE:In contrast to conventional linear gradients, gradient coil arrays with arbitrary spatial dependency might experience strong mutual coupling. Although conventional gradient power amplifiers with feedback loop might compensate the effect of coupling, required voltages for the compensation are generally unknown a...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.27768
更新日期:2019-09-01 00:00:00
abstract::Experimental procedures for obtaining localized 31P NMR spectra of humans by means of the ISIS sequence are discussed in detail. The technique is optimized for use with volume coils and with surface coils in order to measure localized 31P NMR spectra of different tissues and organs. Selective frequency-modulated (FM) ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910110102
更新日期:1989-07-01 00:00:00
abstract::The myelin sheath, which is wrapped around the axons in the brain, can be affected by many diseases, resulting in cognitive and physical disability. Other work showed water in the myelin sheath has a T2 approximately 15 ms. The current standard technique to estimate the fraction of myelin water in vivo is to collect m...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.10713
更新日期:2004-03-01 00:00:00
abstract::Proton MR spectroscopy ((1)H-MRS) has been used for in vivo quantification of intracellular triglycerides within the sarcolemma. The purpose of this study was to assess whether breath-hold dual-echo in- and out-of-phase MRI at 3.0 T can quantify the fat content of the myocardium. Biases, including T(1), T*(2), and noi...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.22289
更新日期:2010-04-01 00:00:00
abstract::Dynamic contrast-enhanced MRI using gadolinium or manganese provides unique characterization of myocardium and its pathology. In this study, an electrocardiography (ECG) triggered saturation recovery Look-Locker method was developed and validated for fast cardiac T(1) mapping in small animal models. By sampling the in...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.22544
更新日期:2010-11-01 00:00:00
abstract::Functional MRI studies to date have been generally performed using the blood oxygenation level dependent (BOLD) contrast mechanism. Recently, it has been proposed that dynamic change in the apparent diffusion coefficient (ADC), measured using intravoxel incoherent motion (IVIM) weighting, can be used as a robust funct...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.20293
更新日期:2004-12-01 00:00:00