Direct MR arthrography of the shoulder: is exercise prior to imaging beneficial or detrimental?

Abstract:

PURPOSE:To define the beneficial and detrimental effects of adding exercise to direct magnetic resonance (MR) shoulder arthrography. MATERIALS AND METHODS:Direct, intraarticular, gadolinium arthrography of the shoulder was performed in 41 patients, who underwent 1.5-T MR imaging before and after 1 minute of arm swinging. Fourteen milliliters of dilute gadolinium solution was injected. Two readers blinded to exercise independently graded the randomly distributed images with a five-point scale for capsular contrast material resorption; extraarticular contrast material leakage; rotator cuff, glenoid labrum, and anterior capsule conspicuity; and partial-thickness or full-thickness rotator cuff tear and labral tear detectability. The sign test was performed to evaluate the significance of differences between preexercise and postexercise grading for each reader. A second review was performed, with direct side-by-side comparison of preexercise and postexercise images. RESULTS:There was evidence of increased capsular resorption after exercise but no alteration in the depiction of the rotator cuff tendons or glenoid labrum. There was no significant extraarticular contrast material leakage after exercise and no alteration in depiction of the anterior capsule. There was no difference in the detectability of rotator cuff or labral tears. CONCLUSION:Exercise with direct shoulder MR arthrography has no beneficial or detrimental effect on image quality or on the depiction of rotator cuff or labral tears.

journal_name

Radiology

journal_title

Radiology

authors

Brenner ML,Morrison WB,Carrino JA,Nusser CA,Sanders TG,Howard RF,Meier P

doi

10.1148/radiology.215.2.r00ma14491

subject

Has Abstract

pub_date

2000-05-01 00:00:00

pages

491-6

issue

2

eissn

0033-8419

issn

1527-1315

journal_volume

215

pub_type

杂志文章
  • The fascicles of the lateral meniscus: an anatomic-arthrographic correlation.

    abstract::A model of the normal anatomy of the capsular attachments of the posterior horn of the lateral meniscus is developed based upon anatomic dissections. The term "fascicles" is applied to the delicate bands of connective tissue which join the posterior lateral meniscus to the joint capsule around the popliteal synovial s...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/114.2.335

    authors: Jelaso DV

    更新日期:1975-02-01 00:00:00

  • Assessment of acute renal transplant rejection with blood oxygen level-dependent MR imaging: initial experience.

    abstract:PURPOSE:To prospectively assess the oxygenation state of renal transplants and determine the feasibility of using blood oxygen level-dependent (BOLD) magnetic resonance (MR) imaging to differentiate between acute tubular necrosis (ATN), acute rejection, and normal function. MATERIALS AND METHODS:This HIPAA-compliant s...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2363041080

    authors: Sadowski EA,Fain SB,Alford SK,Korosec FR,Fine J,Muehrer R,Djamali A,Hofmann RM,Becker BN,Grist TM

    更新日期:2005-09-01 00:00:00

  • Hepatocellular carcinoma: hepatocyte-selective enhancement at gadoxetic acid-enhanced MR imaging--correlation with expression of sinusoidal and canalicular transporters and bile accumulation.

    abstract:PURPOSE:To investigate the mechanism of enhancement of hepatocellular carcinoma (HCC) on gadoxetic acid-enhanced hepatobiliary phase magnetic resonance (MR) images and to characterize HCC thus enhanced. MATERIALS AND METHODS:This retrospective study was approved by the institutional review board, and patient informed ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.10091557

    authors: Tsuboyama T,Onishi H,Kim T,Akita H,Hori M,Tatsumi M,Nakamoto A,Nagano H,Matsuura N,Wakasa K,Tomoda K

    更新日期:2010-06-01 00:00:00

  • Atypical radiographic features in Pneumocystis carinii pneumonia.

    abstract::The chest films in 30 proved cases of Pneumocystis carinii pneumonia were reviewed to determine the incidence of atypical radiographic findings. Seventeen of 30 patients or 56% presented at least one atypical radiographic finding during the course of the disease. Unilateral distribution, lobar involvement, abscess for...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/114.1.39

    authors: Doppman JL,Geelhoed GW,De Vita VT

    更新日期:1975-01-01 00:00:00

  • Acute-phase response after stent implantation in the carotid artery: association with 6-month in-stent restenosis.

    abstract:PURPOSE:To determine the prognostic importance of periintervention serum levels of acute-phase reactants in 6-month restenosis after stent implantation in the carotid artery. MATERIALS AND METHODS:One hundred eight consecutive patients with 70% or greater stenosis of the internal carotid artery (ICA) according to the ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2272020183

    authors: Schillinger M,Exner M,Mlekusch W,Rumpold H,Ahmadi R,Sabeti S,Lang W,Wagner O,Minar E

    更新日期:2003-05-01 00:00:00

  • Pitfalls in mammography: demonstrating deep lesions.

    abstract::The difficulty of demonstrating lesions near the chest wall is one source of error in mammography. A mediolateral xeroradiograph of the breast which images the chest wall was added to the routine mediolateral and cephalocaudal film-screen projections to minimize this problem. In one case, a posterior breast lesion was...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.136.3.6250200

    authors: Bassett LW,Pagani JJ,Gold RH

    更新日期:1980-09-01 00:00:00

  • Degeneration of the ipsilateral substantia nigra after striatal infarction: evaluation with MR imaging.

    abstract:PURPOSE:To evaluate the degeneration of the ipsilateral substantia nigra after striatal infarction by using magnetic resonance (MR) imaging. MATERIALS AND METHODS:Twenty-five adult patients with embolic cerebral infarction of the middle cerebral artery distribution underwent MR imaging 0-4, 5-9, 12-15, and 27-29 days ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.204.3.9280270

    authors: Ogawa T,Okudera T,Inugami A,Noguchi K,Kado H,Yoshida Y,Uemura K

    更新日期:1997-09-01 00:00:00

  • Use of low-osmolar agents and premedication to reduce the frequency of adverse reactions to radiographic contrast media: a survey of the Society of Uroradiology.

    abstract:PURPOSE:To assess the decisions made by uroradiologists regarding choice of type of intravenous contrast material (low-osmolar contrast media [LOCM] vs conventional ionic agents) and frequency of use of corticosteroid prophylaxis. MATERIALS AND METHODS:A questionnaire was mailed to 158 members of the Society of Urorad...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.194.2.7824710

    authors: Cohan RH,Ellis JH,Dunnick NR

    更新日期:1995-02-01 00:00:00

  • MR imaging and scintigraphy of gene expression through melanin induction.

    abstract:PURPOSE:To determine whether an expression vector that encodes for human tyrosinase, the key enzyme in the melanin production pathway, can be used to image gene expression with magnetic resonance (MR) imaging and scintigraphy. MATERIALS AND METHODS:Mouse fibroblasts and human embryonal kidney cells were transfected wi...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.204.2.9240530

    authors: Weissleder R,Simonova M,Bogdanova A,Bredow S,Enochs WS,Bogdanov A Jr

    更新日期:1997-08-01 00:00:00

  • Concomitant boron-neutron capture therapy during fast-neutron irradiation of a rat glioma.

    abstract:PURPOSE:Fast-neutron irradiation and boron-neutron capture therapy (BNCT) have been independently investigated as treatments for malignant disease. This study tested the feasibility of enhancing fast-neutron irradiation with concomitant BNCT. MATERIALS AND METHODS:Seventeen male Fisher rats, each weighing 180-200 g an...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.191.3.8184080

    authors: Buchholz TA,Rasey JS,Laramore GE,Livesey JC,Chin L,Risler R,Hamlin DK,Spence AM,Griffin TW

    更新日期:1994-06-01 00:00:00

  • Epiphyseal growth plate: evaluation with modified coronal CT.

    abstract::A method of modified coronal computed tomography (CT) was developed for examination of epiphyseal growth plate arrest and neoplasms near the growth plate. Twenty-four patients were examined with this technique (26 examinations). In all cases, the growth plate and adjacent regions were well demonstrated. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.166.1.3336690

    authors: Murray K,Nixon GW

    更新日期:1988-01-01 00:00:00

  • Suspected anastomotic recurrence of Crohn disease after ileocolic resection: evaluation with CT enteroclysis.

    abstract:PURPOSE:To determine the utility of computed tomographic (CT) enteroclysis for characterization of the status of the anastomotic site in patients with Crohn disease who had previously undergone ileocolic resection. MATERIALS AND METHODS:Written informed consent was prospectively obtained from all patients, and the ins...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.09091165

    authors: Soyer P,Boudiaf M,Sirol M,Dray X,Aout M,Duchat F,Vahedi K,Fargeaudou Y,Martin-Grivaud S,Hamzi L,Vicaut E,Rymer R

    更新日期:2010-03-01 00:00:00

  • Aggressive Intrasegmental Recurrence of Hepatocellular Carcinoma after Radiofrequency Ablation: Risk Factors and Clinical Significance.

    abstract:PURPOSE:To evaluate the frequency, risk factors, and clinical significance of aggressive intrasegmental recurrence (AIR) found after radiofrequency (RF) ablation for hepatocellular carcinoma (HCC). MATERIALS AND METHODS:Institutional review board approval was obtained for this retrospective study. Between March 2005 a...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.15141215

    authors: Kang TW,Lim HK,Lee MW,Kim YS,Rhim H,Lee WJ,Gwak GY,Paik YH,Lim HY,Kim MJ

    更新日期:2015-07-01 00:00:00

  • Femoral MR angiography versus conventional angiography: preliminary results.

    abstract:PURPOSE:To develop a bilateral femoral magnetic resonance (MR) angiographic examination that would include the aortic bifurcation to the ankle. MATERIALS AND METHODS:Thirty-seven patients underwent conventional angiography and the bilateral femoral MR angiographic examination. Two-dimensional time-of-flight angiograph...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.189.1.8372190

    authors: Quinn SF,Demlow TA,Hallin RW,Eidemiller LR,Szumowski J

    更新日期:1993-10-01 00:00:00

  • Real-time computer verification for radiation therapy treatment machines.

    abstract::A computer based verification system which monitors the operation of a 4-MV linear accelerator is described. Fourteen parameters can be checked for proper alignment prior to irradiation. A training simulator was also built to minimize interference with treatment schedules and to provide technicians with experience in ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/131.1.258

    authors: Sternick ES,Berry JR,Curran B,Loomis SA

    更新日期:1979-04-01 00:00:00

  • Modification of a serial film changer for frontal magnification angiography.

    abstract::A movable carriage was designed and built for a Franklin film changer to facilitate routine serial 2 times magnification. This simple device permits magnification angiography without major equipment purchases or room alterations. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/117.2.481a

    authors: Spitzer RM,Olsson HE,Gibson BJ

    更新日期:1975-11-01 00:00:00

  • Kidney function: glomerular filtration rate measurement with MR renography in patients with cirrhosis.

    abstract:PURPOSE:To assess the accuracy of glomerular filtration rate (GFR) measurements obtained with low-contrast agent dose dynamic contrast material-enhanced magnetic resonance (MR) renography in patients with liver cirrhosis who underwent routine liver MR imaging, with urinary clearance of technetium 99m ((99m)Tc) pentetic...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.11101338

    authors: Vivier PH,Storey P,Rusinek H,Zhang JL,Yamamoto A,Tantillo K,Khan U,Lim RP,Babb JS,John D,Teperman LW,Chandarana H,Friedman K,Benstein JA,Skolnik EY,Lee VS

    更新日期:2011-05-01 00:00:00

  • Ethmoid sinus disease: CT evaluation in 400 cases. Part II. Postoperative findings.

    abstract::Clinical, pathologic, and computed tomographic (CT) findings were reviewed in 400 patients with ethmoid sinus disease, including 272 who had undergone surgery. The postoperative appearance of ethmoid sinuses on CT scans is a highly neglected subject in radiologic literature. The unique ethmoid anatomy permits a variet...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.159.3.3704140

    authors: Som PM,Lawson W,Biller HF,Lanzieri CF

    更新日期:1986-06-01 00:00:00

  • Steady-state free precession imaging in the presence of motion: application for improved visualization of the cerebrospinal fluid.

    abstract::The authors discuss the appropriate FISP (fast imaging with steady-state precession) sequence structure to maintain constant phase at the radio-frequency pulse in the presence of motion. They present preliminary results of its application to head and spine imaging in an effort to maintain contrast between the cerebros...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.175.2.2326480

    authors: Haacke EM,Wielopolski PA,Tkach JA,Modic MT

    更新日期:1990-05-01 00:00:00

  • Appraisal of the angiographic circulation time as an index of cerebral blood flow.

    abstract::The relationship of the brain angiographic mode circulation time (AVCT) to the mean transit time of the vascular indicator C15O-labeled hemoglobin (tc15o) and the regional cerebral blood flow (rCBF) as measured by the clearance of the diffusible tracer H2-15O was examined in 38 patients with selected cerebral diseases...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/115.1.107

    authors: Gado M,Eichling J,Grubb R,Phelps M,Raichie M,Ter-Pogossian MM

    更新日期:1975-04-01 00:00:00

  • Chronic obstructive pulmonary disease: quantitative and visual ventilation pattern analysis at xenon ventilation CT performed by using a dual-energy technique.

    abstract:PURPOSE:To evaluate the potential of xenon ventilation computed tomography (CT) in the quantitative and visual analysis of chronic obstructive pulmonary disease (COPD). MATERIALS AND METHODS:This study was approved by the institutional review board. After informed consent was obtained, 32 patients with COPD underwent ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.10091502

    authors: Park EA,Goo JM,Park SJ,Lee HJ,Lee CH,Park CM,Yoo CG,Kim JH

    更新日期:2010-09-01 00:00:00

  • Breast specimen radiography: evaluation of a compression device.

    abstract::The irregular shape and uneven tissue thickness of excised breast specimens makes radiographic evaluation difficult, especially when calcifications are not present. Xeroradiographs before and after compression of 20 separate excised breast specimens were compared, and 17 of the same specimens were compared after compr...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.168.2.3393660

    authors: Chilcote WA,Davis GA,Suchy P,Paushter DM

    更新日期:1988-08-01 00:00:00

  • Antiangiogenic tumor treatment: early noninvasive monitoring with USPIO-enhanced MR imaging in mice.

    abstract:PURPOSE:To prospectively investigate steady-state blood volume measurements for early quantitative monitoring of antiangiogenic treatment with ultrasmall superparamagnetic iron oxide (USPIO)-enhanced magnetic resonance (MR) imaging. MATERIALS AND METHODS:The institutional animal care committee approved all experiments...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2442060371

    authors: Persigehl T,Bieker R,Matuszewski L,Wall A,Kessler T,Kooijman H,Meier N,Ebert W,Berdel WE,Heindel W,Mesters RM,Bremer C

    更新日期:2007-08-01 00:00:00

  • Deep pelvic abscesses: transperineal US-guided drainage.

    abstract:PURPOSE:To examine the efficacy of transperineal sonographically guided drainage of deep pelvic abscesses. MATERIALS AND METHODS:Twelve drainage procedures were performed in 11 adults with symptoms of infection and cross-sectional images demonstrating a deep pelvic abscess. Eight patients had recently undergone abdomi...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.208.1.9646800

    authors: Sperling DC,Needleman L,Eschelman DJ,Hovsepian DM,Lev-Toaff AS

    更新日期:1998-07-01 00:00:00

  • Systemic hypocalcemia after clinical injections of radiographic contrast media: amelioration by omission of calcium chelating agents.

    abstract::Intravascular injection of some radiographic contrast media causes a fall in the concentration of unbound serum calcium (Ca++) and an increase in serum immunoreactive parathyroid hormone (iPTH). The decrease in Ca++ levels was attributed to the presence in the contrast media of calcium chelating agents (disodium edeta...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.147.3.6405450

    authors: Mallette LE,Gomez LS

    更新日期:1983-06-01 00:00:00

  • Nonsurgical treatment of arteriovenous malformations of the trunk and limb by transcatheter arterial embolization.

    abstract::Two patients with large arteriovenous malformations (AVM) were successfully treated by transcatheter selective arterial embolization with Gelfoam. An extensive lumbar retroperitoneal acquired AVM was markedly reduced, eliminating any clinical evidence of a persistent left-to-right shunt. A large localized congenital A...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/15.3.609

    authors: Stanley RJ,Cubillo E

    更新日期:1975-06-01 00:00:00

  • Focal Nodular Hyperplasia and Hepatocellular Adenoma: Accuracy of Gadoxetic Acid-enhanced MR Imaging--A Systematic Review.

    abstract:PURPOSE:To perform a systematic review to evaluate the diagnostic accuracy of hepatobiliary (HPB) phase gadoxetic acid-enhanced MR imaging of the liver in the diagnosis of focal nodular hyperplasia (FNH) versus hepatocellular adenoma (HCA) and to identify the rate of (a) reported HCAs that are iso- or hyperintense to l...

    journal_title:Radiology

    pub_type: 杂志文章,评审

    doi:10.1148/radiol.2015142986

    authors: McInnes MD,Hibbert RM,Inácio JR,Schieda N

    更新日期:2015-11-01 00:00:00

  • A pattern recognition method for the removal of streaking artifact in computed tomography.

    abstract::A new method is presented for the removal of streaking artifact in computed tomography. The method uses a nearest-neighbor pattern recognition technique to redetermine ray sums that intersect the foreign object responsible for the streaking. When the method is applied to the removal of streaking artifact caused by lea...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.141.1.7291530

    authors: Morin RL,Raeside DE

    更新日期:1981-10-01 00:00:00

  • Recurrent benign biliary strictures: management with self-expanding metallic stents.

    abstract::Self-expanding metallic stents of a modified Gianturco design were used to treat benign strictures of the biliary tree in 17 patients. Thirteen patients had undergone several unsuccessful surgical repairs, and four had not undergone surgery because of their clinical status. All patients had already undergone multiple ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.175.3.2343110

    authors: Rossi P,Bezzi M,Salvatori FM,Maccioni F,Porcaro ML

    更新日期:1990-06-01 00:00:00

  • Needle localization of occult breast lesions with a curved-end retractable wire: technique and pitfalls.

    abstract::A series of 100 consecutive occult mammographic abnormalities were localized with a curved-end retractable wire system. A true-positive rate of 24% and a failure rate of 4% for initial excision were found. The pitfalls and advantages of this new needle-wire breast localizer are presented. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.161.2.3763930

    authors: Homer MJ,Pile-Spellman ER

    更新日期:1986-11-01 00:00:00